An FDISON

.INTERNATIOVAL? Company A. Edward Schierer Manager of Nuclear Regulatory Affairs July 23, 2004 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

Subject:

San Onofre Nuclear Generating Station Units 2 and 3 Docket Nos. 50-361 and 50-362 Proposed Change Number (PCN) 545 Request To Revise Technical Specifications 3.3.1 and 3.3.5

References:

1)

Letter from D. E. Nunn (SCE) to the Document Control Desk (NRC) dated July 28, 2003;

Subject:

San Onofre Nuclear Generating Station Units 2 and 3, Docket Nos. 50-361 and 50-362, Proposed Change Number (PCN) 545, Request To Revise Technical Specifications 3.3.1 and 3.3.5

2)

Letter from B. M. Pham (NRC) to H. B. Ray (SCE) dated October 22, 2003;

Subject:

San Onofre Nuclear Generating Station, Units 2 And 3 - Request For Additional Information Regarding Steam Generator Pressure-Low Allowable Value (TAC NOS. MC0200 and MC0201)

Dear Sir or Madam:

Reference (1) was a request by Southern California Edison (SCE) to change the Technical Specification Steam Generator Pressure-Low allowable value from its current value of 729 psia to a revised value of 717 psia. The request was identified as Proposed Change Number (PCN) 545.

By Reference (2), NRC staff requested additional information regarding PCN-545 needed for the staff to continue its review of the proposed change.

SCE is preparing a response to Reference (2) and will be submitting it by December 31, 2004. The response will replace Reference (1) in its entirety, and SCE, therefore, requests that it be withdrawn.

P.O. Box 128 7°D)

San Clemente, CA 92674-0128 949-368-7501 Fax 949-368-7575

Document Control Desk July 23, 2004 If you have any questions or require any additional information, please contact Mr. Jack Rainsberry at (949) 368-7420.

Sincerely, cc: B. S. Mallett, NRC Region IV, Regional Administrator B. M. Pham, NRC Project Manager, San Onofre Units 2 and 3 C. C. Osterholtz, NRC Senior Resident Inspector, San Onofre Units 2 and 3 S. Y. Hsu, Department of Health Services, Radiologic Health Branch