Prairie Island - Units 1& 2-LAR - 3/25/04 - Main Steam Line Mass & Energy release using BAW-10169-A In reference to the above submittal, NRC staff has following questions which they would like to discuss with you. Please indicate your availability to have a teleconference with the staff.
- 1. Page 5. Explain the choice of 0.6 ft2 for the lower bound break size for the sensitivity study.
Are split breaks considered?
- 2. Verify that both cases with and without loss of offsite power will be considered to determine the limiting case.
- 3. Describe or provide a reference for the treatment of entrainment in the break flow. Was this included in the core response calculations?
- 4. Page 5. The statement is made that liquid inventory is maximized. But this corresponds to zero power. How is this consistent with sensitivity study to select limiting power?
- 5. Page 5. Why isnt a single failure of the auxiliary feedwater automatic run-out protection analyzed?
- 6. Page 5. Is the description of the modeling of the steam system consistent with the current licensing basis?
CC:
Richard Lobel Mail Envelope Properties (40A38399.D8D : 15 : 21352)
Subject:
Prairie Island - Units 1& 2-LAR - 3/25/04 - Main Steam Line Mass &
Energy release using BAW-10169-A Creation Date:
5/13/04 10:18AM From:
Mahesh Chawla Created By:
MLC@nrc.gov Recipients Action Date & Time nmcco.com Transferred 05/13/04 10:18AM Dale.Vincent (Dale.Vincent@nmcco.com) nrc.gov owf2_po.OWFN_DO Delivered 05/13/04 10:18AM RML CC (Richard Lobel)
Post Office Delivered Route nmcco.com owf2_po.OWFN_DO 05/13/04 10:18AM nrc.gov Files Size Date & Time MESSAGE 1867 05/13/04 10:18AM Options Auto Delete:
No Expiration Date:
None Notify Recipients:
Yes Priority:
Standard Reply Requested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard To Be Delivered:
Immediate Status Tracking:
Delivered & Opened