Text
SAFEGUARDS INFORMATION SAFEGUARDS INFORMATION WARNING: Violation of Section 147 of the Atomic Energy Act, Safeguards Information is subject to Civil and Criminal Penalties June 21, 2004 Mr. Thomas J. Palmisano Site Vice President c/o Mr. Tim Gallagher Nuclear Management Company, LLC 2807 West County Road 75 Monticello, MN 55362-9637
SUBJECT:
MONTICELLO NUCLEAR GENERATING PLANT - REQUEST FOR ADDITIONAL INFORMATION RE: SECURITY PLAN SECTIONS 10-19 (TAC NO. MC2940)
Dear Mr. Palmisano:
In response to the April 29, 2003, Orders revising the design basis threat, you submitted revised physical security plans, safeguards contingency plans, and guard training and qualification plans, including an implementation schedule, for Monticello Nuclear Generating Plant. The Nuclear Regulatory Commission staff is reviewing your submission and has determined that a request for additional information (RAI) is necessary in order to complete its evaluation based on its review of Sections 10 through 19 of your physical security plan. We discussed the enclosed RAI with you and Mr. Ron Baumer of your staff during a telephone call on May 21, 2004. Please respond to the enclosed RAI within 10 days from the date of this NOTICE: The enclosed information contains Safeguards Information. Upon separation from the Enclosure, this letter is DECONTROLLED.
SAFEGUARDS INFORMATION SAFEGUARDS INFORMATION T. J. Palmisano letter. If circumstances result in the need to revise the target response date, please contact me at (301) 415-3498.
Sincerely,
/RA/
Bhalchandra K. Vaidya, Project Manager Security Plan Review Team Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-263
Enclosure:
As stated cc w/o encl: See next page
SAFEGUARDS INFORMATION SAFEGUARDS INFORMATION T. J. Palmisano letter. If circumstances result in the need to revise the target response date, please contact me at (301) 415-3498.
Sincerely,
/RA/
Bhalchandra K. Vaidya, Project Manager Security Plan Review Team Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-263
Enclosure:
As stated cc w/o encl: See next page DISTRIBUTION:
PUBLIC SPRT R/F J. Nakoski J. Peralta C. Hawes BVaidya OGC ACRS M. Padovan L. Raghavan B. Ruland S. Reynolds, RIII ADAMS Accession Number: ML041750537 OFFICE SPRT/NRR/PM SPRT/NRR/LA SPRT/NSIR SPRT/NRR/SC NAME BVaidya CHawes JPeralta JNakoski DATE 6/18/04 6/18/04 6/21/04 6/21/04 OFFICIAL RECORD COPY
Monticello Nuclear Generating Plant cc:
Jonathan Rogoff, Esquire Vice President, Counsel & Secretary Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 U.S. Nuclear Regulatory Commission Resident Inspectors Office 2807 W. County Road 75 Monticello, MN 55362 Manager, Regulatory Affairs Monticello Nuclear Generating Plant Nuclear Management Company, LLC 2807 West County Road 75 Monticello, MN 55362-9637 Robert Nelson, President Minnesota Environmental Control Citizens Association (MECCA) 1051 South McKnight Road St. Paul, MN 55119 Commissioner Minnesota Pollution Control Agency 520 Lafayette Road St. Paul, MN 55155-4194 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Commissioner Minnesota Department of Health 717 Delaware Street, S. E.
Minneapolis, MN 55440 Douglas M. Gruber, Auditor/Treasurer Wright County Government Center 10 NW Second Street Buffalo, MN 55313 Commissioner Minnesota Department of Commerce 121 Seventh Place East Suite 200 St. Paul, MN 55101-2145 Manager - Environmental Protection Division Minnesota Attorney Generals Office 445 Minnesota St., Suite 900 St. Paul, MN 55101-2127 John Paul Cowan Executive Vice President & Chief Nuclear Officer Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Nuclear Asset Manager Xcel Energy, Inc.
414 Nicollet Mall, R.S. 8 Minneapolis, MN 55401 Mr. Thomas J. Palmisano Site Vice President Monticello Nuclear Generating Plant Nuclear Management Company, LLC 2807 West County Road 75 Monticello, MN 55362-9637