Emergency Response Data System (ERDS)
ML041560364
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 05/17/2004
From: Rosalyn Jones
Duke Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML041560364 (28)


Text

Duke R. A.

JONES

  • Power, Vice President A Duke Energy Company Duke Power 29672 / Oconee Nuclear Site 7800 Rochester Highway Seneca, SC 29672 864 885 3158 864 885 3564 fax May 17, 2004 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555

Subject:

Oconee Nuclear Station Docket Number 50-269, 50-270, 50-287 Emergency Response Data System (ERDS) 10CFR50, Appendix E, Section VI, 3a requires that any software change that affects the transmitted data points identified in the ERDS Data Point Library must be submitted to the NRC within 30 days after changes are completed.

Changes to the Data Point Library were due to plant modifications, consistencies with instrument calibration and data points and several editorial changes to make all unit data points consistent.

The correct pages of the effected Data Point Library are attached for your information.

Changes are indicated by a sidebar.

If there are any questions regarding the Emergency Response Data System, please contact Ray Waterman at (864) 885-3825.

Sincere R.

.oe VP, Oconee Nuclear Station cc:

Louis Reyes, NRC/Regional Administrator, Region II Tom Kardaras/Office of Analysis & Evaluation Mel Shannon/Oconee Resident Inspector Lynne Saul/Scientech At OW www. duke-energy. com

VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO EACH USE NSD 227 Nuclear Policy Manual - Volume 2 NRC CORRESPONDENCE REVIEW AND CONCURRENCE FORM Applicable Site(s) ONS Submittal Title/

Subject:

C MNS

[1 CNS a1 U. S. Nuclear Regulatory Commission Emergency Response Data System (ERDS)

Background Information:

Scheduled Submittal Date:

Mandatory Submittal Date? (Y/N)

PORC Approval Date Submittal Lead Name NSRB Approval Date Rodney Brown Commitment Review Y/N Phone 864-885-3301 Content Development (Attach additional Information as needed)

Contributor Name/Site Scope/extent of Contribution or Portion Contributed Individual Review (Attach additional Information as needed)

IReviewer Name/Site I

Signature I Portions or Subjects Reviewed and Nature of Review

]

I I _

_ I Regulatory Review Legal Dept. Review (Optional)

This completed form must be presented with the original submittal for signature. The form may be filled in with reference to e-mailed information in place of actual signatures and required information so long as the e-mailed Information is maintained with the copy of this form that is sent to Master file.

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OCI N/A CTMNT TEMP O1A0043 RB DOME TEMP CONTAINMENT TEMPERATURE A

DEG F N/A 0

400 N/A N/A S

1 NIA INSIDE CONTAINMENT ELEV. 945 FEET HIGH = 140.0 N/A N/A

        • or NNNN N

N/A ELEV. INSIDE TOP OF CONTAINMENT IS 983+5 FEET; Unit 1 Reactor Building Dome Air Temperature

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OCI N/A LP SI FLOW O0A1310 LPI HDR IA INJECTION FLOW LOW PRESSURE SAFETY INJECTION A

GPM N/A 0.00 4000.00 N/A N/A S

I N/A East Penetration Room LOW = 800 High = 3700 N/A N/A LOW N

N/A Value derived from d/p developed across flow orifice I

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

AnalogtDigital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OCI N/A LP SI FLOW OIA131 1 LPI HDR lB INJECTION FLOW LOW PRESSURE SAFETY INJECTION A

GPM N/A 0.00 4000.00 N/A N/A S

I N/A East Penetration Room LOW =800 High - 3700 N/A N/A LOW N

N/A Value derived from d/p developed across flow orifice I

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OC2 N/A CORE FLOW 02A1549 RPS CH A TOTAL RCS FLOW TOTAL REATOR COOLANT FLOW A

KLB/HR N/A 0

180000 N/A N/A P

2 Sum of Loop A + Loop B Uncompensated RC GENTILLI TUBE IN HOT LEG TO FLOW TRAN:

None j

N/A NIA LOW N

N/A TOTAL RC FLOW = LOOP A UNCOMPENSATED RC FLOW

+ LOOP B UNCOMPENSATED RC FLOW lo e mSrevT # L-tV 3 t5 AlAen4fp,'iA LOS5 t+v4e Mo46 CAL

+n -tC AleUs CdAA4dAi e45V ctg!fcfD.

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OC3 N/A CORE FLOW 03A1549 RPS CH A TOTAL RCS FLOW TOTAL REATOR COOLANT FLOW A

KLB/HR N/A 0

180000 N/A N/A p

2 Sum of Loop A + Loop B Uncompensated RC GENTILLI TUBE IN HOT LEG TO FLOW TRAN!

NONE N/A N/A LOW N

N/A TOTAL RC FLOW = LOOP A UNCOMPENSATED RC FLOW +

LOOP B UNCOMPENSATED RC FLOW

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OCI N/A CORE FLOW OA1549 RPS CH A TOTAL RCS FLOW TOTAL REATOR COOLANT FLOW A

KLB/HR N/A 0

180000 N/A N/A P

2 Sum of Loop A + Loop B Uncompensated RC GENTILLI TUBE IN HOT LEG TO FLOW TRAN:

NONE N/A N/A LOW N

N/A TOTAL RC FLOW = LOOP A UNCOMPENSATED RC FLOW +

LOOP B UNCOMPENSATED RC FLOW

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OC2 N/A CTMNT TEMP 02A0043 RB DOME TEMP CONTAINMENT TEMPERATURE A

DEG F N/A 0

400 N/A N/A S

I N/A INSIDE CONTAINMENT ELEV. 945 FEET HIGH = 140 N/A N/A

        • or NNNN N

N/A ELEV. INSIDE TOP OF CONTAINMENT IS 983+5 FEET; Unit 2 Reactor Building Dome Air Temperature

Oconee Emergency Response Data System Reactor Data FB NRC ERDS Parai Po Plant Spec Point Generic/Cond Analog/D Eng Units/Dig S Eng Units Conve Minimum Instr R Maximum Instr R Zero Point Refei Reference Point r Proc or Number of Sel How Proc(

Sensor Loca Alarm/Trip Set P NI Detector Cutoff Power I I Detector Cuton Power I Instrument Failure ?

Temperature Compens Level Reference Unique System Date:

05t18/2004 Unit:

OC2

'eder:

N/A neter:

LP SI FLOW int Id:

02A1310 Desc:

LPI HDR 2A INJECTION FLOW Desc:

LOW PRESSURE SAFETY INJECTION igital:

A States:

GPM rsion:

N/A

.ange:

0.00

.ange:

4000.00 rence:

N/A Notes:

N/A Sens:

S nsors:

I essed:

N/A

.tions:

East Penetration Room

'oints:

LOW = 800.0 HIGH =3700.00 Level:

N/A

.evel:

N/A Mode:

LOW ation:

N eLeg:

N/A Desc:

Value derived from d/p developed across flow orifice

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OC2 N/A LP SI FLOW 02A131 1 LPI HDR 2B INJECTION FLOW LOW PRESSURE SAFETY INJECTION A

GPM N/A 0.00 4000.00 N/A N/A S

I N/A East Penetration Room LOW = 800.00 HIGH =3700.0 N/A N/A LOW N

N/A Value derived from d/p developed across flow orifice I

Oconee Emergency Response Data System Reactor Data Fi NRC ERDS Parai Po Plant Spec Point Generic/Cond Analog/D Eng Units/Dig 5 Eng Units Conve Minimum lnstr R Maximum Instr lR Zero Point Refei Reference Point r Proc or Number of Sei How Proci Sensor Loca Alarm/Trip Set P NI Detector Cutoff Power I I Detector Cuton Power I Instrument Failure l\\

Temperature Compens Level Referenct Unique System Date:

05/18/2004 r Unit:

OC3 eeder:

N/A meter:

HL TEMP 1/A int Id:

03E2279 Desc:

RC HOT LEG A WR TEMP Desc:

STM GEN A INLET TEMPERATURE igital:

A States:

DEG F rsion:

N/A

ange:

50.00

ange:

700 rence:

N/A Notes:

N/A Sens:

S nsors:

1 essed:

N/A

.tions:

RC Hot Leg A oints:

HIGH = 618.00 Level:

N/A Level:

N/A Aode:

MEDIUM ation:

N zLeg:

N/A Desc:

Field signal processed by ICCM and displayed in Control Room

Oconee Emergency Response Data System Date:

05/18/2004 Reactor Unit:

OC3 Data Feeder:

N/A NRC ERDS Parameter:

HL TEMP 2/B Point Id:

03E2280 Plant Spec Point Desc:

RC HOT LEG B WR TEMP Generic/Cond Desc:

STM GEN B INLET TEMPERATURE Analog/Digital:

A Eng Units/Dig States:

DEG F Eng Units Conversion:

N/A Minimum Instr Range:

50.00 Maximum Instr Range:

700 Zero Point

Reference:

N/A Reference Point Notes:

N/A Proc or Sens:

S Number of Sensors:

I How Processed:

N/A Sensor Locations:

RC Hot Leg B Alarm/Trip Set Points:

HIGH = 618.00 NI Detector Cutoff Power Level:

N/A I Detector Cuton Power Level:

N/A Instrument Failure Mode:

MEDIUM Temperature Compensation:

N Level Reference Leg:

N/A Unique System Desc:

Field signal processed by ICCM and displayed in Control Room

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NT Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OCI N/A SG LEVEL 1/A OIE2002 SG IA FULL LEVEL STEAM GENERATOR A WATER LEVE A

INCHES N/A 0

650 COMPLE SEE PO/0/A11108/01, Encl. 3.19 S

I N/A RB Low =

N/A N/A LOW High - 630.00 N

N/A From FDWLT0007P Lo j

Tn t~A *

,'s3D Loua "LZ JA 6F

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OC2 N/A SG LEVEL I/A 02E2002 SG 2A FULL LEVEL STEAM GENERATOR A WATER LEVE A

INCHES N/A 0

650 COMPLE SEE PO0//A/1 108/01. Encl. 3.19 S

I N/A RB Low =

High =630 N/A N/A LOW N

N/A From FDWLT0007P

Oconee Emergency Response Data System Date:

05/18/2004 Reactor Unit:

OC2 Data Feeder:

N/A NRC ERDS Parameter:

SG LEVEL 2/B Point Id:

02E2007 Plant Spec Point Desc:

SG 2B FULL LEVEL Generic/Cond Desc:

STEAM GENERATOR B WATER LEVE Analog/Digital:

A Eng Units/Dig States:

INCHES Eng Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

650 Zero Point

Reference:

COMPLE Reference Point Notes:

SEE PO10/AII 108/01, Encl. 3.19 Proc or Sens:

S Number of Sensors:

I How Processed:

N/A Sensor Locations:

?

Alarm/Trip Set Points:

Low =

High = 630 NI Detector Cutoff Power Level:

N/A I Detector Cuton Power Level:

N/A Instrument Failure Mode:

LOW Temperature Compensation:

N Level Reference Leg:

NIA Unique System Desc:

From FDWLT0009P

Oconee Emergency Response Data System Date:

05/18/2004 Reactor Unit:

OC I Data Feeder:

N/A NRC ERDS Parameter:

WIND SPEED Point Id:

01P0163 Plant Spec Point Desc:

AVERAGE WIND SPEED 10 M Generic/Cond Desc:

WIND SPEED AT THE REATOR SITE Analog/Digital:

A Eng Units/Dig States:

MPH Eng Units Conversion:

N/A Minimum Instr Range:

-3 Maximum Instr Range:

63 Zero Point

Reference:

N/A Reference Point Notes:

N/A Proc or Sens:

S Number of Sensors:

I How Processed:

N/A Sensor Locations:

33 FT ABOVE GROUND Alarm/Trip Set Points:

NONE NJ Detector Cutoff Power Level:

N/A I Detector Cuton Power Level:

N/A Instrument Failure Mode:

LOW 0 Temperature Compensation:

N Level Reference Leg:

N/A Unique System Desc:

SEE ATTACHMENT

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OCI N/A STAB CLASS 01P0160 ENVIRONMENTAL AVERAGE DELTA TEMPEI AIR STABILITY AT THE REACTOR SI' A

DEG C N/A

-3.4 8.6 N/A NIA P

2 N/A NONE N/A N/A INDETERMINATE N

N/A SEE ATTACHMENT I

Oconee Emergency Response Data System Date:

05/18/2004 Reactor Unit:

OCI Data Feeder:

N/A NRC ERDS Parameter:

WIND SPEED Point Id:

01P0159 Plant Spec Point Desc:

AVERAGE WIND SPEED RV SITE Generic/Cond Desc:

WIND SPEED ST THE REATOR SITE Analog/Digital:

A Eng Units/Dig States:

MPH Eng Units Conversion:

N/A Minimum Instr Range:

-3 Maximum Instr Range:

63 Zero Point

Reference:

N/A Reference Point Notes:

N/A Proc or Sens:

S Number of Sensors:

I How Processed:

N/A Sensor Locations:

?

Alarm/Trip Set Points:

NONE NI Detector Cutoff Power Level:

N/A I Detector Cuton Power Level:

N/A Instrument Failure Mode:

LOW 0 Temperature Compensation:

N Level Reference Leg:

N/A Unique System Desc:

SEE ATTACHMENT

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OCI N/A WIND SPEED 01P0158 AVERAGE WIND SPEED 60 M WIND SPEED AT THE REATOR SITE A

MPH N/A

-3 63 N/A N/A S

l N/A 197 FT ABOVE GROUND NONE N/A N/A LOW 0 N

N/A SEE ATTACHMENT

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OC2 N/A WIND SPEED 02P0158 AVERAGE WIND SPEED 60 M WIND SPEED AT THE REATOR SITE A

MPH N/A

-3 63 N/A N/A S

I N/A 197 FT ABOVE GROUND NONE N/A N/A LOW 0 N

N/A SEE ATTACHMENT I

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OC2 N/A WIND SPEED 02P0159 AVERAGE WIND SPEED RV SITE WIND SPEED ST THE REATOR SITE A

MPH N/A

-3 63 N/A N/A S

I N/A NONE N/A N/A LOW 0 N

N/A SEE ATTACHMENT I

Oconee Emergency Response Data System Reactor Data F NRC ERDS Parai Po Plant Spec Point Generic/Cond Analog/D Eng Units/Dig 5 Eng Units Conve Minimum lnstr F Maximum Instr R Zero Point Refei Reference Point I Proc or Number of Se How Proc Sensor Loca Alarm/Trip Set P NI Detector Cutoff Power I I Detector Cuton Power I Instrument Failure I Temperature Compens Level Referenc Unique System Date:

05/18/2004 r Unit:

OC2 eeder:

N/A meter:

STAB CLASS int Id:

02P0160 Desc:

ENVIRONMENTAL AVERAGE DELTA TEMPEI Desc:

AIR STABILITY AT THE REACTOR SI'

)igital:

P States:

DEG C

rsion:

N/A Lange:

-3.4 lange:

8.6 rence

N/A Notes:

N/A Sens:

P nsors:

2 essed:

N/A ations:

?

'oints:

NONE Level:

N/A Level:

N/A M.ode:

INDETERMINATE gation:

N Leg:

N/A Desc:

SEE ATTACHMENT

r----

R Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OC2 N/A WIND SPEED 02P0163 AVERAGE WIND SPEED 10 M WIND SPEED AT THE REATOR SITE A

MPH N/A

-3 63 N/A N/A S

I N/A 33 FT ABOVE GROUND NONE N/A N/A LOW O N

N/A SEE ATTACHMENT

Oconee Emergency Response Data System Date:

05/18/2004 Reactor Unit:

OC3 Data Feeder:

N/A NRC ERDS Parameter:

WIND SPEED Point Id:

03P0158 Plant Spec Point Desc:

AVERAGE WIND SPEED 60 M Generic/Cond Desc:

WIND SPEED AT THE REATOR SITE Analog/Digital:

A Eng Units/Dig States:

MPH Eng Units Conversion:

N/A Minimum Instr Range:

-3 Maximum Instr Range:

63 Zero Point

Reference:

N/A Reference Point Notes:

N/A Proc or Sens:

S Number of Sensors:

I How Processed:

N/A Sensor Locations:

197 FT ABOVE GROUND Alarm/Trip Set Points:

NONE NI Detector Cutoff Power Level:

N/A I Detector Cuton Power Level:

N/A Instrument Failure Mode:

LOW 0 Temperature Compensation:

N Level Reference Leg:

N/A Unique System Desc:

SEE ATTACHMENT

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OC3 N/A WIND SPEED 03P0159 AVERAGE WIND SPEED RV SITE WIND SPEED ST THE REATOR SITE A

MPH N/A

-3 63 N/A N/A S

1 N/A

?

NONE N/A N/A LOW 0 N

N/A SEE ATTACHMENT I

Oconee Emergency Response Data System Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point Id:

Plant Spec Point Desc:

Generic/Cond Desc:

Analog/Digital:

Eng Units/Dig States:

Eng Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

Proc or Sens:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Cutoff Power Level:

I Detector Cuton Power Level:

Instrument Failure Mode:

Temperature Compensation:

Level Reference Leg:

Unique System Desc:

05/18/2004 OC3 N/A STAB CLASS 03P0160 ENVIRONMENTAL AVERAGE DELTA TEMPEI AIR STABILITY AT THE REACTOR sr P

DEG C N/A

-3.4 8.6 N/A N/A P

2 N/A NONE N/A N/A INDETERMINATE N

N/A SEE ATTACHMENT

Oconee Emergency Response Data System Date:

05/18/2004 Reactor Unit:

OC3 Data Feeder:

N/A NRC ERDS Parameter:

WIND SPEED Point Id:

03P0163 Plant Spec Point Desc:

AVERAGE WIND SPEED 10 M Generic/Cond Desc:

WIND SPEED AT THE REATOR SITE Analog/Digital:

A Eng Units/Dig States:

MPH Eng Units Conversion:

N/A Minimum Instr Range:

-3 Maximum Instr Range:

63 Zero Point

Reference:

N/A Reference Point Notes:

N/A Proc or Sens:

S Number of Sensors:

I How Processed:

N/A Sensor Locations:

33 FT ABOVE GROUND Alarm/Trip Set Points:

NONE NI Detector Cutoff Power Level:

N/A I Detector Cuton Power Level:

N/A Instrument Failure Mode:

LOW 0 Temperature Compensation:

N Level Reference Leg:

N/A Unique System Desc:

SEE ATTACHMENT