Supplement to Relief Request ISI-06
ML041460280
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 05/17/2004
From: Devincentis J
Entergy Nuclear Operations, Entergy Nuclear Vermont Yankee
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
BVY 04-48, FOIA/PA-2004-0267
Download: ML041460280 (3)


Text

Entergy Nuclear Vermont Yankee, LLC Entergy

-- I Entergy Nuclear Operations, Inc.

185 Old Ferry Road Brattleboro, Vr 05302-0500 May 17, 2004 BVY 04-48 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Subject:

Vermont Yankee Nuclear Power Station License No. DPR-28 (Docket No. 50-271)

Supplement to Relief Reguest ISI-06 On September 25, 2003, Vermont Yankee Nuclear Power Station (VY) submitted to the NRC Inservice Inspection (ISI) Relief Request ISI-06.1 ISI-06 requested relief from the inspection requirements of ASME Section Xl, Class 1, Examination Category B-A, Code Item No. BI.1 1, for Circumferential Shell Welds.

During the NRC's review of Relief Request ISI-06, the reviewer inquired about a flaw indication contained within the circumferential weld E-F at approximately 72 that was last reviewed for acceptability by the NRC in April 19992. During a follow-up conference call, the NRC reviewer requested that VY commit to re-inspecting the flaw indication during one of the next two refueling outages.

Accordingly, during VY's recent refueling outage (RFO 24, April 2004), the subject indication was inspected. The inspection results indicate that the flaw dimensions have not enlarged and the flaw remains bounded by that previously categorized. Specifically, the PDI qualified ultrasonic sizing technique revealed the indication to be the same length but the thru-wall dimension was slightly smaller. The results of this examination will be reported along with our other ISI examination results per ASME Section Xi and 10 CFR 50.55a requirements.

The Attachment identifies that there are no commitments contained within this letter.

If you should have any questions please contact Mr. James M. DeVincentis at (802) 258-4236.

Sincerely, 1./~James M. DeVincentis Manager, Licensing Attachment cc: USNRC Region I Administrator USNRC Resident Inspector - VY USNRC Project Manager - VY Vermont Department of Public Service Reference VY Letter to USNRC, BVY 03-83, "Supplement to Fourth-Interval Inservice Inspection (ISI)

Program Plan - Submittal of Relief Request ISI-06," dated September 25, 2003.

2 Reference USNRC Letter to VY, NVY 99-40, "Reactor Pressure Vessel Circumferential Weld Examination Frequency at Vermont Yankee Nuclear Power Station (TAC No. MA4629)," dated April 7, 1999.

Docket No. 50-271 BVY 0448 Attachment Vermont Yankee Nuclear Power Station Supplement to Relief Request ISI-06 List of Commitments

SUMMARY

OF VERMONT YANKEE COMMITMENTS BVY NO.: 04-48 The following table identifies commitments made in this document by Vermont Yankee. Any other actions discussed in the submittal represent intended or planned actions by Vermont Yankee. They are described to the NRC for the NRC's information and are not regulatory commitments. Please notify the Licensing Manager of any questions regarding this document or any associated commitments.

COMMITMENT COMMITTED DATE

_ OR "OUTAGE" None I N/A 4