AmerenUE Cal/away Plant PO Box 620 Fulton, MO 65251 May 21, 2004 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop P1-137 Washington, DC 20555-0001 ULNRC-5002 WAmermn UE Ladies and Gentlemen:

DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.

FACILITY OPERATING LICENSE NPF-30 1997 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Enclosed are revised sections of the 1997 Annual Radioactive Effluent Release Report (ARERR). This submittal includes revised Meteorological data tables and recalculated doses to the public from gaseous releases in 1997. These tables were revised due to intermittent electrical interferences that affected the Primary Meteorological Tower 10 and 60 meter wind speed transmitters. These errors resulted in a slight increase in the calculated dose to the public. However, the calculated dose is still only a small percentage of the regulatory limits.

Sincerely,

/1y69 04 Keith D.

g Manager, Regulatory Affairs DJW/hao Enclosure

,:t'eTB a subsidiary efAmervn Corporadon

ULNRC-5002 5/21/04 Page 2 cc:

U.S. Nuclear Regulatory Commission (Original and 1 copy)

Attn: Document Control Desk Mail Stop P1-137 Washington, DC 20555-0001 Mr. Bruce S. Mallett Regional Administrator U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-4005 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. Jack N. Donohew (2 copies)

Licensing Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop 7E1 Washington, DC 20555-2738 Missouri Public Service Commission Governor Office Building 200 Madison Street PO Box 360 Jefferson City, MO 65102-0360

f TABLE 5 DOSE AT THE SITE BOUNDARY AND TO THE NEAREST RESIDENT FROM GASEOUS EFFLUENTS SITE BOUNDARY NEAREST RESIDENT LOCATION: 1.40 km SSW l LOCATION: 3.04 km NNW AGE GROUP: CHILD AGE GROUP: CHILD ORGAN UNITS DOSE

% LIMIT(a)

DOSE

% LIMIT(b)

1. GAMMA AIR DOSE *MRAD 4.69E-03 0.05 2.59E-03 N/A
2. BETA AIR DOSE
  • MRAD 1.26E-02 0.06 6.96E-03 N/A
3. WHOLE BODY ***

MREM 4.00E-03 N/A 2.22E-03 N/A

4. SKIN ***

MREM 9.43E-03 N/A 5.22E-03 N/A

5. BONE **

MREM 8.63E-07 N/A 3.95E-06 0.00

6. LIVER
  • MREM 2.22E-03 N/A 1.05E-02 0.07
7. TOTAL BODY **

MREM 2.22E-03 N/A 1.05E-02 0.07

8. THYROID **

MREM 2.23E-03 N/A 1.16E-02 0.08

9. KIDNEY **

MREM 2.22E-03 N/A 1.05E-02 0.07

10. LUNG **

MREM 2.22E-03 N/A 1.05E-02 0.07

11. GI-LLI **

MREM 2.22E-03 N/A 1.05E-02 0.07

  • Dose from Noble Gases only
    • Dose from Tritium, Radioiodines, and Particulates only
      • Dose from Noble Gases plus Ground Plane dose (a) Annual dose limits of Offsite Dose Calculation Manual (APA-ZZ-01003) of 10 mrad gamma air dose and 20 mrad beta air dose.

(b) Annual dose limits of Offsite Dose Calculation Manual (APA-ZZ-01003) of 15 mrem to any organ from 1-131, I-133, H-3 and particulate radionuclides with halflives greater than 8 days.

Page 1 of 1

r TABLE 6 DOSE TO THE MEMBER OF THE PUBLIC FROM ACTIVITIES WiTHIN THE SITE BOUNDARY EFFLUENT DIRECT DIRECT TOTAL DOSE WITHIN RADIATION RADIATION DOSE THE SITE FROM THE FROM OUTSIDI FOR THE ORGAN UNITS BOUNDARY UNIT TANKS YEAR

1. SKIN MREM 2.24E-03 N/A N/A 2.24E-03
2. BONE MREM 2.49E-07 8.79E-03 9.59E-05 8.89E-03
3. LIVER MREM 6.75E-04 8.79E-03 9.59E-05 9.56E-03
4. TOTAL BODY MREM 1.63E-03 8.79E-03 9.59E-05 1.05E-02
5. THYROID MREM 6.76E-04 8.79E-03 9.59E-05 9.56E-03
6. KIDNEY M[REm 6.751-04 8.79E-03 9.59E-05 9.5 6E-03
7. LUNG MREM 6.75E-04 8.79E-03 9.59E-05 9.56E-03
8. GI-LLI MREM 6.75E-04 8.79E-03 9.59E-05 9.56E-03 Page 1 of 1

TABLE 7 TOTAL DOSE DUE TO THE URAIUM FUEL CYCLE (MEMBER OF THE PUBLIC)

DOSE FROM TOTAL DOSE DOSE AT THE ACTIVITIES TO THE RESIDENCE WITHIN SITE MEMBER OF ORGAN UNITS LOCATION BOUNDARY THE PUBLIC

% LIMITS *

1. SKIN MREM 3.04E-03 2.24E-03 5.29E-03 0.02
2. BONE MREM 9.31E-07 8.89E-03 8.89E-03 0.04
3. LIVER MREM 3.65E-03 9.56E-03 1.32E-02 0.05
4. TOTAL BODY MREM 4.94E-03 1.05E-02 1.55E-02 0.06
5. THYROID MREM 3.93E-03 9.56E-03 1.35E-02 0.02
6. KIDNEY MREM 3.65E-03 9.56E-03 1.32E-02 0.05
7. LUNG MREM 3.65E-03 9.56E-03 1.32E-02 0.05
8. GI-LLI MREM 3.65E-03 9.56E-03 1.32E-02 0.05
  • Annual dose limits from 40CFR190.10(a) of 25 mrem whole body, 75 mrem to the thyroid, and 25 mrem to any other organ.

Page 1 of 1

Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:52.95 Meteorological Data Averages Using Hourly Averaged Data 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00

% GOOD DATA UNITS VALUES Stability Class A-G E

98%

Total Precipitation CM.

1.01E+02 99%

10 Meter Level:

Wind Speed Meter/Sec 3.10E+00 100%

Wind Direction Degrees 2.51E+02 99%

Wind Direction Variability Degrees 1.30E+01 99%

Reference Temperature Degrees C 1.20E+01 100%

Dewpoint Degrees C 5.39E+00 99%

60 Meter Level:

Wind Speed Meter/Sec 5.17E+00 99%

Wind Direction Degrees 2.41E+02 97%

Wind Direction Variability Degrees 8.69E+00 98%

Dewpoint Degrees C NONE 0%

Temperature Difference 60 - 10 Degrees C 1.20E-01 98%

Page 1 of 1

Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:55.73 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: A Wind Speed at 10.00 Meter Level (MPH)

I T

I I

I 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 0

1 0

0 0

1 NNE 0

2 1

0 0

0 3

NE 0

3 1

0 0

0 4

ENE 0

3 0

0 0

0 3

E 0

4 3

0 0

0 7

ESE 0

6 5

0 0

0 11 SE 2

19 18 0

0 0

39 SSE 5

27 15 3

0 0

50 S

2 38 25 4

0 0

69 SSW 3

42 32 1

0 0

78 SW 3

37 27 8

0 0

75 WSW 1

12 4

3 0

0 20 W

2 11 3

0 0

0 16 WNW 0

10 17 8

0 0

35 NW 0

4 5

11 0

0 20 NNW 3

1 2

0 0

0 6

TOT 21 219 159 38 0

0 437 Hours of Calm Data:

Hours of Invalid Data:

0 10 Page 1 of 7

Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:55.73 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: B Wind Speed at 10.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

1 11 4

2 0

0 18 NNE 1

5 3

0 0

0 9

NE 0

5 7

0 0

0 12 ENE 1

4 5

0 0

0 10 E

1 5

1 0

0 0

7 ESE 1

4 7

3 0

0 15 SE 2

12 4

1 0

0 19 SSE 3

19 7

0 0

0 29 S

2 13 10 4

0 0

29 SSW 2

9 17 2

0 0

30 SW 2

14 13 2

0 0

31 WSW 0

14 7

1 0

0 22 W

2 16 6

4 1

0 29 WNW 3

21 11 3

0 0

38 NW 0

10 21 6

0 0

37 NNW 0

3 10 3

0 0

16 TOT 21 165 133 31 1

0 351 Hours of Calm Data:

Hours of Invalid Data:

0 14 Page 2 of 7

Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:55.73 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: C Wind Speed at 10.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

2 14 17 5

0 0

38 NNE 1

13 5

0 0

0 19 NE 5

6 14 0

0 0

25 ENE 2

5 8

0 0

0 15 E

0 6

2 0

0 0

8 ESE 0

5 6

2 0

0 13 SE 0

16 9

0 0

0 25 SSE 6

13 8

1 0

0 28 S

2 11 9

9 0

0 31 SSW 5

18 20 3

0 0

46 SW 3

15 10 3

0 0

31 WSW 6

10 8

1 2

0 27 W

3 20 5

3 2

0 33 WNW 4

15 16 5

0 0

40 NW 4

17 20 5

0 0

46 NNW 2

9 20 1

0 0

32 TOT 45 193 177 38 4

0 457 Hours of Calm Data:

Hours of Invalid Data:

1 5

Page 3 of 7

Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:55.73 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: D Wind Speed at 10.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

17 83 115 11 0

0 226 NNE 25 79 60 7

0 0

171 NE 18 74 37 1

0 0

130 ENE 8

56 50 4

0 0

118 E

8 63 66 2

0 0

139 ESE 14 60 43 5

0 0

122 SE 15 65 27 7

1 0

115 SSE 19 52 33 9

3 0

116 S

12 44 40 8

1 0

105 SSW 19 66 42 18 1

0 146 SW 22 55 25 8

1 0

111 WSW 16 50 36 4

2 3

111 W

21 87 86 42 4

0 240 WNW 21 94 153 59 1

0 328 NW 26 83 105 33 1

0 248 NNW 30 96 92 12 0

0 230 TOT 291 1107 1010 230 15 3

2656 Hours of Calm Data:

Hours of Invalid Data:

9 10 Page 4 of 7

Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:55.73 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: E Wind Speed at 10.00 Meter Level (MPH)

Y I

1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

29 111 28 4

0 0

172 NNE 39 91 16 0

0 0

146 NE 26 71 9

1 0

0 107 ENE 21 75 29 8

2 0

135 E

21 86 46 3

0 0

156 ESE 22 96 36 5

0 0

159 SE 23 140 93 3

1 0

260 SSE 27 136 69 17 0

0 249 S

31 99 90 27 0

0 247 SSW 26 82 69 9

0 0

186 SW 23 71 42 4

0 0

140 WSW 31 58 20 1

1 0

111 W

29 77 59 7

0 0

172 WNW 32 110 66 16 0

0 224 NW 46 112 62 15 1

0 236 NNW 39 149 65 8

1 0

262 TOT 465 1564 799 128 6

0 2962 Hours of Calm Data:

Hours of Invalid Data:

26 21 Page 5 of 7

Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:55.73 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: F Wind Speed at 10.00 Meter Level (MPH) u Y

I 1

1 T

1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

22 28 0

0 0

0 50 NNE 19 27 1

1 0

0 48 NE 16 13 0

0 0

0 29 ENE 28 12 2

0 0

0 42 E

17 9

3 0

0 0

29 ESE 37 19 0

0 0

0 56 SE 44 79 8

0 0

0 131 SSE 28 150 8

0 0

0 186 23 101 12 0

0 0

136 SSW 26 63 6

0 0

0 95 SW 35 59 5

0 0

0 99 WSW 20 16 0

0 0

0 36 W

14 39 7

0 0

0 60 WNW 33 34 0

0 0

0 67 NW 26 40 1

0 0

0 67 NNW 14 44 0

0 0

0 58 TOT 402 733 53 1

0 0

1189 Hours of Calm Data:

Hours of Invalid Data:

21 5

Page 6 of 7

Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:55.73 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: G Wind Speed at 10.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

20 14 0

0 0

0 34 NNE 25 10 0

0 0

0 35 NE 19 2

1 0

0 0

22 ENE 9

4 0

0 0

0 13 E

11 0

1 0

0 0

12 ESE 11 6

0 0

0 0

17 SE 16 26 3

0 0

0 45 SSE 26 89 8

0 0

0 123 S

35 27 3

0 0

0 65 SSW 23 16 0

0 0

0 39 SW 21 14 0

0 0

0 35 WSW 5

1 0

0 0

0 6

W 10 6

0 0

0 0

16 WNW 19 8

0 0

0 0

27 NW 9

38 0

0 0

0 47 NNW 6

9 0

0 0

0 15 TOT 265 270 16 0

0 0

551 Hours of Calm Data:

Hours of Invalid Data:

Hours of Good Data:

24 5

8684 = 99.1% of Total Hours Page 7 of 7

Ui Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:57.82 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: A Wind Speed at 60.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 1

0 0

0 01 NNE 1

3 1

1 0

0 6

NE 0

0 3

0 0

0 3

ENE 0

2 1

0 0

0 3

E 0

3 3

0 0

0 6

ESE 0

5 9

0 0

0 14 SE 1

10 24 2

0 0

37 SSE 1

20 24 9

0 0

54 S

0 17 31 17 1

0 66 SSW 0

30 30 21 0

1 82 SW 0

17 27 17 8

0 69 WSW 1

5 10 1

2 0

19 W

1 10 8

2 0

0 21 WNW 0

3 13 10 5

3 34 NW 1

3 3

4 8

0 19 NNW 0

0 2

0 0

0 2

TOT 6

129 189 84 24 4

436 Hours of Calm Data:

Hours of Invalid Data:

1 10 Page 1 of 7

Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:57.82 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: B Wind Speed at 60.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 4

6 4

0 0

14 NNE 0

11 1

2 0

0 14 NE 0

6 9

1 0

0 16 ENE 0

0 5

2 0

0 7

E 0

3 2

0 0

0 5

ESE 1

2 8

4 0

0 15 SE 2

13 5

1 0

0 21 SSE 1

15 9

1 0

0 26 S

1 9

7 8

3 0

28 SSW 1

4 19 9

1 2

36 SW 1

11 10 8

0 0

30 WSW 2

3 15 4

0 1

25 W

1 8

15 5

3 2

34 WNW_

2 9

17 6

3 2

39 NW 2

4 14 10 3

0 33 NNW 2

3 3

5 1

0 14 TOT 16 105 145 70 14 7

357 Hours of Calm Data:

Hours of Invalid Data:

0 8

Page 2 of 7

9' Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:57.82 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: C Wind Speed at 60.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

0 9

13 7

1 0

30 NNE 0

8 9

5 0

0 22 NE 0

4 16 4

0 0

24 ENE 3

5 11 0

0 0

19 E

0 1

5 0

0 0

6 ESE 0

3 10 2

1 0

16 SE 0

12 9

3 0

0 24 SSE 2

11 9

5 0

0 27 S

2 5

8 6

6 0

27 SSW 3

13 16 14 3

0 49 SW 2

7 8

9 1

0 27 WSW 2

9 10 6

3 3

33 W

0 12 10 4

3 1

30 WNW 1

11 19 10 6

0 47 NW 0

10 12 12 2

0 36 NNW 2

9 15 4

1 0

31 TOT 17 129 180 91 27 4

448 Hours of Calm Data:

Hours of Invalid Data:

2 13 Page 3 of 7

U Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:57.82 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: D Wind Speed at 60.00 Meter Level (MPH) 1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

10 48 78 64 5

0 205 NNE 14 51 69 27 3

0 164 NE 10 53 68 27 1

1 160 ENE 9

29 63 28 0

0 129 E

4 36 64 30 0

0 134 ESE 0

27 61 21 0

0 109 SE 5

47 42 9

4 0

107 SSE 5

26 42 26 7

3 109 S

6 25 39 31 4

3 108 SSW 7

40 53 30 23 3

156 SW 10 35 43 11 5

4 108 WSW 13 20 45 29 12 6

125 W

8 27 93 70 47 21 266 WNW 2

36 89 108 43 24 302 NW 12 38 75 76 16 8

225 NNW 13 39 98 38 8

2 198 TOT 128 577 1022 625 178 75 2605 Hours of Calm Data:

Hours of Invalid Data:

8 62 Page 4 of 7

Ui E

A Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:57.82 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN.1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: E Wind Speed at 60.00 Meter Level (MPH)

Y I

Y I

Y I

1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

4 34 110 45 5

0 198 NNE 3

23 105 9

0 0

140 NE 3

38 79 10 0

0 130 ENE 2

23 89 28 3

7 152 E

1 15 77 38 2

0 133 ESE 1

27 110 41 2

0 181 SE 5

17 111 84 4

0 221 SSE 4

24 93 86 13 3

223 S

6 30 59 114 24 5

238 SSW 7

21 57 119 32 2

238 SW 4

18 43 51 14 1

131 WSW 6

26 39 32 5

2 110 W

3 26 56 80 32 1

198 WNW 5

24 83 55 22 5

194 NW 1

24 102 75 13 4

219 NNW 4

41 99 63 7

0 214 TOT 59 411 1312 930 178 30 2920 Hours of Calm Data:

Hours of Invalid Data:

8 81 Page 5 of 7

v.

"I Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:57.82 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC-1997 23:00:00.00 Stability Class: F Wind Speed at 60.00 Meter Level (MPH)

I.

Y I

1-3 4-7 8-12 13-18 19-24

>24 TOTAL N

1 5

20 24 0

0 50 NNE 2

3 28 12 1

0 46 NE 0

7 27 4

0 0

38 ENE 2

6 24 13 0

0 45 E

1 3

27 5

0 0

36 ESE 4

9 37 7

0 0

57 SE 2

12 47 28 1

0 90 SSE 1

22 56 32 2

0 113 S

5 19 96 61 1

0 182 SSW 1

7 42 76 9

0 135 SW 1

11 31 45 5

0 93 WSW 3

16 21 26 2

0 68 W

1 7

9 29 4

0 50 WNW 1

6 24 28 3

0 62 NW 3

9 24 10 0

0 46 NNW 1

12 29 20 0

0 62 TOT 29 154 542 420 28 0

1173 Hours of Calm Data:

Hours of Invalid Data:

1 41 Page 6 of 7

or V

r i

Union Electric - Callaway Plant Report Date/Time: 19-MAY-2004 10:17:57.82 Meteorological Data Totals of Hours at Each Wind Speed & Direction 1-JAN-1997 00:00:00.00 to 31-DEC.1997 23:00:00.00 Stability Class: G Wind Speed at 60.00 Meter Level (MH)

Y I

Y I

1-3

.4-7 8-12 13-18 19-24

>24 TOTAL N

1 2

1 12 0

0 16 NNE 0

3 9

6 0

0 18 NE 1

4 18 4

0 0

27 ENE 1

2 22 7

0 0

32 E

0 6

15 5

0 0

26 ESE 0

1 7

5 0

0 13 SE 1

6 16 2

0 0

25 SSE 2

5 32 18 1

0 58 S

0 12 58 25 0

0 95 SSW 1

9 19 29 4

0 62 SW 2

6 25 23 8

0 64 WSW 2

6 5

2 0

0 15 W

1 3

4 2

2 0

12 WNW 1

3 6

4 2

0 16 NW 0

3 8

12 0

0 23 NNW 0

5 23 13 1

0 42 TOT 13 76 268 169 18 0

544 Hours of Calm Data:

Hours of Invalid Data:

Hours of Good Data:

1 35 8504 = 97.1% of Total Hours Page 7 of 7