L Thomas Alexion - QUESTIONS ON RESIDUAL STRESSES Paae 1 1 From:

Thomas Alexion To:

DAVANT, GUY H Date:

4/1/04 12:46PM

Subject:

QUESTIONS ON RESIDUAL STRESSES

Guy, See the attached.

Tom

"-,. 11

......1 I C:\\W1ND0WS\\TEMP\\GW100001.TMP Page 1 I C:\\WINDOWS\\TEMP\\GWIOOOOl.TMP Pane 1 I Mail Envelope Properties (406C557A.25C: 0: 20628)

Subject:

Creation Date:

From:

Created By:

QUESTIONS ON RESIDUAL STRESSES 4/1/04 12:46PM Thomas Alexion TWA@nrc.gov Recipients entergy.com GDAVANT (DAVANT, GUY H)

Action Date & Time Route entergy.com Post Office Files ResidualStresses.wpd MESSAGE Options Auto Delete:

Expiration Date:

Notify Recipients:

Priority:

Reply Requested:

Return Notification:

Concealed

Subject:

Security:

To Be Delivered:

Status Tracking:

Delivered Pending Size 2509 655 Date & Time 04/01/04 12:43PM 04/01/04 12:46PM No None Yes Standard No None No Standard Immediate Delivered & Opened

QUESTIONS RELATED TO RESIDUAL STRESSES RELIEF REQUEST R&R-006 ARKANSAS NUCLEAR ONE, UNIT 1

1.

In the ANO Calculation 86-E-0074-156, weld residual stresses were not considered.

The revised analysis considered the weld residual stresses. Discuss the technical basis for including the residual stresses in the revised analysis and excluding the residual stresses in the previous analysis.

2.

Clarify whether the J-groove weld and butter weld were heat treated to relieve residual stresses during ANO-1 reactor vessel head fabrication.

3.

How many plants has Framatome performed the same J-groove weld calculations, as performed for the ANO-1 plant?