CNRO-2004-00028, Request for Alternatives ANO1-R&R-005 - Proposed Alternative to ASME Weld Repair Requirements for Repairs Performed on Reactor Vessel Head Penetration Nozzles

From kanterella
(Redirected from ML041330262)
Jump to navigation Jump to search

Request for Alternatives ANO1-R&R-005 - Proposed Alternative to ASME Weld Repair Requirements for Repairs Performed on Reactor Vessel Head Penetration Nozzles
ML041330262
Person / Time
Site: Arkansas Nuclear 
Issue date: 05/03/2004
From: Burford F
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
CNRO-2004-00028
Download: ML041330262 (7)


Text

=-Entrgy Operations, Inc.

E te-rs 1340 Echelon Parkway Ei I e

rg Jackson, Mississippi 39213-8298 L/

Tel 601-368-5758 F. G. Burford Acting Director Nuclear Safety & Licensing CNRO-2004-00028 May 3, 2004 U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Request for Alternatives ANO1-R&R-005 -

Proposed Alternative to ASME Weld Repair Requirements for Repairs Performed on Reactor Vessel Head Penetration Nozzles Arkansas Nuclear One, Unit 1 Docket No. 50-313 License No. DPR-51

REFERENCE:

Entergy Operations, Inc. letter CNRO-2004-00023 to the NRC dated April 12, 2004

Dear Sir or Madam:

In the referenced letter, Entergy Operations, Inc., (Entergy) transmitted to the NRC staff ANO Calculation 86-E-0074-154, which supports Entergy's Request for Alternative ANO1-R&R-005. (This calculation was provided to Entergy by Framatome-ANP, Inc. as Framatome Document 32-5012424.)

Framatome-ANP, Inc., the owner of Framatome Document 32-5012424, considers information contained in this document to be proprietary and confidential pursuant to 10 CFR 2.390(a)(4) and 10 CFR 9.17(a)(4). As such, Framatome has requested that it be withheld from public disclosure. Provided in the enclosure to this letter is the correct affidavit supporting this request. This affidavit replaces the one transmitted to the staff via the referenced letter.

If the staff has any questions regarding the proprietary designation of Framatome Document 32-5012424, please contact Mr. James Mallay, Director, Regulatory Affairs for Framatome at the following address and/or telephone number:

Framatome-ANP, Inc.

P. 0. Box 10935 3315 Old Forest Road Lynchberg, VA 24506-0935 Telephone # (434) 832-3000

  • fiOLn

CNRO-2004-00028 Page 2 of 2 Should you have any questions regarding this letter, please contact Guy Davant at (601) 368-5756.

This letter contains no commitments.

Very truly yours, FGB/GHD/ghd

Enclosure:

Affidavit for Withholding Information from Public Disclosure cc:

Mr. W. A. Eaton (ECH) (w/o Enclosure)

Mr. J. S. Forbes (ANO) (w/o Enclosure)

Dr. Bruce. S. Mallett Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 NRC Senior Resident Inspector Arkansas Nuclear One P. 0. Box 310 London, AR 72847 U. S. Nuclear Regulatory Commission Attn: Mr. T. W. Alexion MS 0-7 D1 Washington, DC 20555-0001

ENCLOSURE CNRO-2004-00028 AFFIDAVIT FOR WITHHOLDING INFORMATION FROM PUBLIC DISCLOSURE

Al AREVA April 2,2004 FANP-04-1080 Mr. Guy A. Davant Entergy Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995

Subject:

AREVA Docurment 32-5012424-10, "CRDM Temper Bead Base Weld Analysis"

Reference:

Entergy Operations Calculation No. 86-E-0074-154. Rev. 0

Dear Mr. Davant,

Entergy Operation, Inc. requested approval from Framatome ANP, Inc. (FANP) to transmit the subject document under the referenced Entergy Calculation to the NRC. The submittal is based upon a NRC request in support of ANO Relief Request for RV Head CRDM Repairs at ANO-1.

FANP, by this letter approves the submittal of the subject document as noted in the referenced Entergy Calculation in support of the FANP IDTB repair process.

FANP maintains the proprietary status of the document and has enclosed the applicable affidavit for Entergy use.

If there are questions regarding this release, please contact me at (434) 832-3767.

Sincerely, Stephen G. Son Project Manager c:

J. Smith, ANO FRAMATOME ANP, INC.

P.O. Box 10935. 3315 Old Forest Road, Lynchburg. VA 24506-0935 Tot.: (434) 832-3000 - Fax: (434) 832-0622 1

1.

AFFIDAVIT COMMONWEALTH OF VIRGINA

)

) ss.

CITY OF LYNCHBURG

)

1.

My name is James F. Mallay. I am Director, Regulatory Affairs, for Framatome ANP C'FANP"), and as such I am authorized to execute this Affidavit.

2.

I am familiar with the criteria applied by FANP to determine whether certain FANP information is proprietary. I am familiar with the policies established by FANP to ensure the proper application of these criteria.

3.

1 am familiar with the information contained in the FANP calculation summary sheet 32-5012424-10, CRDM Temper Bead Bore Weld Analysis." This calculation file is being submitted by Entergy Operations to the NRC as part of Arkansas Nuclear One calculation number 86-E-0074-154 concerning licensed activities at Arkansas Nuclear One, Unit 1. The FANP calculation file is referred to herein as tDocument.* Information contained in this Document has been classified by FANP as proprietary in accordance with the policies established by FANP for the control and protection of proprietary and confidential information.

4.

This Document contains information of a proprietary and confidential nature and is of the type customarily held in confidence by FANP and not made available to the public.

Based on my experience, I am aware that other companies regard information of the kind contained in this Document as proprietary and confidential.

5.

This Document has been made available to the U.S. Nuclear Regulatory Commission in confidence with the request that the information contained In this Document be withheld from public disclosure.

6.

The following criteria are customarily applied by FANP to determine whether information should be classified as proprietary:

(a)

The information reveals details of FANP's research and development plans and programs or their results.

(b)

Use of the information by a competitor would permit the competitor to significantly reduce its expenditures, In time or resources, to design, produce, or market a similar product or service.

(c)

The information includes test data or analytical techniques concerning a process, methodology, or component, the application of which results in a competitive advantage for FANP.

(d)

The information reveals certain distinguishing aspects of a process, methodology, or component, the exclusive use of which provides a competitive advantage for FANP in product optimization or marketability.

(e)

The information is vital to a competitive advantage held by FANP, would be helpful to competitors to FANP, and would likely cause substantial harm to the competitive position of FANP.

7.

In accordance with FANP's policies governing the protection and control of information, proprietary information contained in this Document has been made available, on a limited basis, to others outside FANP only as required and under suitable agreement providing for nondisclosure and limited use of the information.

8.

FANP policy requires that proprietary information be kept in a secured file or area and distributed on a need-to-know basis.

9.

The foregoing statements are true and correct to the best of my knowledge, information, and belief.

SUBSCRIBED before me this _

day of 2004.

Ella F. Carr-Payne NOTARY PUBLIC, STATE OF VIRGINIA MY COMMISSION EXPIRES: 8/31/05 ELLA F. CARR-PAYNE Notary Public Coimnwsatth of Vrginia my Comso iix Ag 31,q31 200