Morning Report Date: MAY 10, 2004 PRIORITY ATTENTION REQUIRED MORNING REPORT - REGION II Licensee/Facility:

Notification:

2-2004-0006 05/10/2004 MR Number:

SOUTHERN NUCLEAR OPERATING CO., INC.

[2] W-4-LP Date:

Vogtle Call from SRI Waynesboro, Georgia 050-00425 Dockets:

STEAM GENERATOR TUBES DEGRADED - UPDATE

Subject:

This Morning Report provides updated information concerning confirmed outer diameter (OD) circumferential cracks in Unit 2 steam generator (SG) tubes. Unit 2 is currently in a scheduled refueling outage. The licensee has completed 100% eddy current testing (ECT) of SG hot leg tubes in all four SGs. The results of the ECT identified one tube in SG 1, two tubes in SG 2, three tubes in SG 3, and two tubes in SG 4 with OD cracking. All tubes were stabilized and plugged.

Two tubes have been pulled in SG 2 for further analysis to determine the degradation mechanism.

The highest indication by ECT of thru-wall cracking was 38%. This tube was one of the two tubes pulled so the actual thru-wall percentage will not be known until analysis is complete.

This information is current as of 12:00 p.m. 5/10/2004.

Discussion:

Contact:

Email:

Phone No:

Org:

BONSER, BRIAN R BRB1@nrc.gov (404) 562-4540 R2