ML041270460
| ML041270460 | |
| Person / Time | |
|---|---|
| Site: | South Texas |
| Issue date: | 04/29/2004 |
| From: | Leazar D South Texas |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| NOC-AE-04001716, STI 31737567 | |
| Download: ML041270460 (30) | |
Text
Nuclear Operating Company Soouh Te cd Ekcdk Gene5Stauon PO Bar 2839 M&wodhy Tcs 7745 A A April 29, 2004 NOC-AE-04001716 10CFR50.36 U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852 South Texas Project Units 1 & 2 Docket Nos. STN 50-498, STN 50499 Core Operating Limits Reports In accordance with Technical Specification 6.9.1.6.d, the attached Core Operating Limits Report is submitted for Unit 2 Cycle 11. This report reflects core design changes made during the 2RE10 refueling outage.
Additionally, Revision 2 for the Core Operating Limits Report for Unit 1 Cycle 12 is attached. This revision corrects a typographical error.
If there are any questions concerning this report, please contact Scott Head at (361) 972-7136 or me at (361) 972-7795.
David A. Leazar
- Director, Nuclear Fuel & Analysis jal Attachments:
- 1. Unit 2 Cycle 11 Core Operating Limits Report, Rev. 0
- 2. Unit 1 Cycle 12 Core Operating Limits Report, Rev. 2 AoA STI: 31737567
NOC-AE-04001716 Page 2 of 2 cc:
(paper copy)
(electronic copy)
Bruce S. Mallett Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852 Richard A. Ratliff Bureau of Radiation Control Texas Department of Health 1100 West 49th Street Austin, TX 78756-3189 Jeffrey Cruz U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN1 16 Wadsworth, TX 77483 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP L. D. Blaylock City Public Service Michael K. Webb U. S. Nuclear Regulatory Commission R. L. Balcom Texas Genco, LP A. Ramirez City of Austin C. A. Johnson AEP Texas Central Company Jon C. Wood Matthews & Branscomb C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 STI: 31737567
5/73303o3>
Nuclear Operating Company SOUTH TEXAS PROJECT UNIT 2 CYCLE 11 CORE OPERATING LIMITS REPORT REVISION 0 April 2004 Core Operating Limits Report Page I
SouTH TExAS UNir 2 CYCLE I 1, REVISION 0 APRIL2004 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report for STPEGS Unit 2 Cycle 11 has been prepared in accordance with the requirements of Technical Specification 6.9.1.6. The core operating limits have been developed using the NRC-approved methodologies specified in Technical Specification 6.9.1.6.
The Technical Specifications affected by this report are:
- 1) 2.1 SAFETY LIMITS
- 2) 2.2 LIMITING SAFETY SYSTEM SETTINGS
- 3) 3/4.1.1.1 SHUTDOWN MARGIN
- 4) 3/4.1.1.3 MODERATOR TEMPERATURE COEFFICIENT LIMITS
- 5) 3/4.1.3.5 SHUTDOWN ROD INSERTION LIMITS
- 6) 3/4.1.3.6 CONTROL ROD INSERTION LIMITS
- 7) 3/4.2.1 AFD LIMITS
- 8) 3/4.2.2 HEAT FLUX HOT CHANNEL FACTOR
- 9) 3/4.2.3 NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR
- 10) 3/4.2.5 DNB PARAMETERS 2.0 OPERATING LIMITS The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented below.
2.1 SAFETY LIMITS (Specification 2.1):
2.1.1 The combination of THERMAL POWER, pressurizer pressure, and the highest operating loop coolant temperature (Tavg) shall not exceed the limits shown in Figure 1.
2.2 LIMITING SAFETY SYSTEM SETTINGS (Specification 2.2):
2.2.1 The Loop design flow for Reactor Coolant Flow-Low is 98,000 gpm.
2.2.2 The Over-temperature AT and Over-power AT setpoint parameter values are listed below:
Core Operating Limits Report Page 2
SOUTH TEXAS UNrr 2 CYCLE 11, REVISION 0 APRIL2004 Over-temperature AT Setpoint Parameter Values
-El measured reactor vessel AT leadflag time constant, rl = 8 sec T2 measured reactor vessel AT lead/lag time constant, x2 = 3 sec T3 measured reactor vessel AT lag time constant, ¶3 = 2 sec T4 measured reactor vessel average temperature lead/lag time constant, x4 = 28 sec T5 measured reactor vessel average temperature lead/lag time constant, x5 = 4 sec T6 measured reactor vessel average temperature lag time constant, T6 = 2 sec KI Overtemperature AT reactor trip setpoint, Kj = 1.14 K2 Overtemperature AT reactor trip setpoint Tavg coefficient, K2 = 0.028/0F K3 Overtemperature AT reactor trip setpoint pressure coefficient) K3 = 0.001 43/psig T'
Nominal full powerTavg, T' < 592.0 0F P'
Nominal RCS pressure, P' = 2235 psig f,(Al) is a function of the indicated difference between top and bottom detectors of the power-range neutron ion chambers; with gains to be selected based on measured instrument response during plant startup tests such that:
(I) For q, - qb between -70% and +8%, f2(AI) = 0, where q, and q, are percent RATED THERMAL POWER in the top and bottom halves of the core respectively, and q, + qb is total THERMAL POWER in percent of RATED THERMAL POWER; (2) For each percent that the magnitude of q, - qb exceeds -70%, the AT Trip Setpoint shall be automatically reduced by 0.0% of its value at RATED THERMAL POWER; and (3) For each percent that the magnitude of q, - q, exceeds +8%, the AT Trip Setpoint shall be automatically reduced by 2.65% of its value at RATED THERMAL POWER Over-power AT Setpoint Parameter Values Tl measured reactor vessel AT lead/lag time constant, TI = 8 sec T2 measured reactor vessel AT lead/lag time constant, T2 =3 sec T3 measured reactor vessel AT lag time constant, ¶C3 = 2 sec T6 measured reactor vessel average temperature lag time constant, T6 = 2 sec
¶7 Time constant utilized in the rate-lagcompensator for Tavg, ¶7 I 1sec K4 Overpower AT reactor trip setpoint, K4 = 1.08 K5 Overpower AT reactor trip setpoint Tavg rate/lag coefficient, K5 0.02/F for increasing average temperature, and K5 = 0 for decreasing average temperature K6 Overpower AT reactor trip setpoint Tavg heatup coefficient K6 = 0.002/°F for T > T', and K6 = 0 for T < T" T'
Indicated full power Tavg, T" < 592.0 °F f2(AI) = 0 for all (Al) 2.3 SHUTDOWN MARGIN (Specification 3.1.1.1):
The SHUTDOWN MARGIN shall be:
2.3.1 Greater than 1.3% Ap for MODES I and 2*
- See Special Test Exception 3.10.1 2.3.2 Greater than the limits in Figure 2 for MODES 3 and 4.
2.3.3 Greater than the limits in Figure 3 for MODE 5.
Core Operating Limits Report Page 3
SOUTH TEXAS UNIT 2 CYCLE 1 1, REVISION 0 APPIL2004 2.4 MODERATOR TEMPERATURE COEFFICIENT (Specification 3.1.1.3):
2.4.1 The BOL, ARO, MTC shall be less positive than the limits shown inFigure 4.
2.4.2 The EOL, ARO, HEP, MTC shall be less negative than -62.6 pcmpF.
2.4.3 The 300 ppm, ARO, HFP, MTC shall be less negative than -53.6 pcm/'F (300 ppm Surveillance Limit).
Where: BOL stands for Beginning-of-Cycle Life, EOL stands for End-of-Cycle Life, ARO stands for All Rods Out, HFP stands for Hot Full Power (100% RATED THERMAL POWER),
HFP vessel average temperature is 592 IF.
2.4.4 The Revised Predicted near-EOL 300 ppm MTC shall be calculated using the algorithm from T.S.
6.9.1.6.b.10:
Revised Predicted MTC = Predicted MTC + AFD Correction - 3 pcml'F If the Revised Predicted MTC is less negative than the SR. 4.1.1.3b limit and all of the benchmark data contained in the surveillance procedure are met, then an MTC measurement in accordance with S.R.
4.1.1.3b is not required.
2.5 ROD INSERTION LIMITS (Specification 3.1.3.5 and 3.1.3.6):
2.5.1 All banks shall have the same Full Out Position (FOP) of at least 249 steps withdrawn but not exceeding 259 steps withdrawn.
2.5:2 The Control Banks shall be limited in physical insertion as specified in Figure 5.
2.5.3 Individual Shutdown bank rods are fully withdrawn when the Bank Demand Indication is at the FOP and the Rod Group Height Limiting Condition for Operation is satisfied (T.S. 3.1.3.1).
2.6 AXIAL FLUX DIFFRENCE (Specification 3.2.1):
2.6.1 AFD limits as required by Technical Specification 3.2.1 are determined by CAOC Operations with an AFD target band of +5, -10%.
2.6.2 The AFD shall be maintained within the ACCEPTABLE OPERATION portion of Figure 6, as required by Technical Specifications.
Core Operating Limits Report Page 4
SOUH TEXAS UNrr2 CYCLE 1 1, REVISION 0 APRIL2004 2.7 HEAT FLUX HOT CHANNEL FACTOR (Specification 3.2.2):
2.7.1 FQ-
= 2.55.
2.7.2 K(Z) is provided in Figure 7.
2.7.3 The Fxy limits for RATED THERMAL POWER (Fr-) within specific core planes shall be:
2.7.3.1 Less than or equal to 2.102 for all cycle burnups for all core planes containing Bank "D" control rods, and 2.7.3.2 Less than or equal to the appropriate core height-dependent value from Table I for all unrodded core planes.
2.7.3.3 PFXY = 0.2.
These Fxy limits were used to confirm that the heat flux hot channel factor FQ(Z) will be limited by Technical Specification 3.2.2 assuming the most-limiting axial power distributions expected to result for the insertion and removal of Control Banks C and D during operation, including the accompanying variations in the axial xenon and power distributions, as described in WCAP-8385. Therefore, these Fxy limits provide assurance that the initial conditions assumed in the LOCA analysis are met, along with the ECCS acceptance criteria of 10 CFR 50.46.
2.8 ENTHALPY RISE HOT CHANNEL FACTOR (Specification 3.2.3):
2.8.1 Fy = 1.557 1 2.8.2 PFAH = 0.3 2.9 DNB PARAMETERS (Specification 3.2.5):
2.9.1 The following DNB-related parameters shall be maintained within the following limits:2
- a.
Reactor Coolant System Tavg, < 595 0F 3,
- b.
Pressurizer Pressure, > 2200 psig 4,
- c.
Minimum Measured Reactor Coolant System Flow5 > 403,000 gpm.
3.0 REFERENCES
3.1 Letter from T. D. Croyle (Westinghouse) to D. F. Hoppes (STPNOC), "Unit 2 Cycle 11 Final Unbound Reload Evaluation," NF-TG-04-29 (ST-UB-NOC-04002469), dated March 19, 2004.
3.2 NUREG-1346, Technical Specifications, South Texas ProjectUnit Nos. I and 2.
3.3 STPNOC Calculation ZC-7035, Rev. 1, "Loop Uncertainty Calculation for RCS Tavg Instrumentation,"
dated October 19, 1998.
3.4 STPNOC Calculation ZC-7032, Rev. 3, "Loop Uncertainty Calculation for Narrow Range Pressurizer Pressure Monitoring Instrumentation," dated June 27,2001.
3.5 Condition Report Engineering Evaluation 02-13857-9, Revision 1, "Reload Safety Evaluation and Core Operating Limits Report for South Texas Unit 2 Cycle II Modes 1, 2, 3, 4, and 5 (from.0 to 535 Effective Full Power Days of Operation)," dated April 14, 2004.
I Applies to all fuel in the Unit 2 Cycle I I Core 2 A discussion of the processes to be used to take these readings is provided in the basis for Technical Specification 3.2.5 3 Includes a 1.9 OF measurement uncertainty per Reference 3.3.
4 Limit not applicable during either a Thermal Power ramp in excess of 5% of RTP per minute or a Thermal Power step in excess of H0M RTP.
Includes a 10.7 psi measurement uncertainty as read on QDPS display per Reference 3.4.
5 Includes a 2.8% flow measurement uncertainty.
Core Operating Limits Report Page 5
a u rc SOUMH TEXAS 'UNIT 2 CYCLE I 1, REVISION 0 APRIL 2004 SourH TEXAS Uiwr 2 CYCLE 11, REVISiON 0 APRIL 2004 Figure 1 Reactor Core Safety Limits - Four Loops in Operation 680 660 640.
Pk 620.
V 600 580 560 540 0
20 40 60 80 100 120 140 Rated Thermal Power (%)
Core Operating Limits Report Page 6
BNG-Soumh TEXAS UNrr 2 CYCLE 1 REVISION 0 APRIL2004 Figure 2 Required Shutdown Margin for Modes 3 & 4 8.0 7.0 6.0 J.
5.0o I
_: a
- c. -.
0 2.0 1.0 0.0 0
400 800 1200 1600 2000 2400 RCS Critical Boron Concentration (ppm)
(for ARI minus most reactive stuck rod)
Core Operating Limits Report Page 7
wag-a SOUTH TExAS UNIT 2 CYCLE I 1, REVISION 0 APRIL2004 Figure 3 Required Shutdown Margin for Mode 5 8.0 7.0 6.0 5-
._M es 0
oW C12 z
5.0 0
C 3 4.0 13.0 2.0 1.0 0.0 0
400 800 1200 1600 2000 2400 RCS Critical Boron Concentration (ppm)
(for ARI minus most reactive stuck rod)
Core Operating Limits Report Page 8
EmirR SouTH TExAs UNIT 2 CYCLE I1I1 REVSIO 0 APRIL 2004 Figure 4 MTC versus Power Level 7.0 6.0 0
U r-
._Wa cE 4) sD U
'I
- I.
cm 5.0 4.0 3.0 2.0 1.0 0.0
-1.0 IUnacceptable Operation]
A I
II I
I I tIe
~I_
-2.0
-3.0 0
20 40 60 80 100 Rated Thermal Power (°/0)
Core Operating Limits Report Page 9
lUno Ir Sourii'fFms UNIT 2 CYCLE I I ; kmsm 0 APRIL2004 Sotmi TEXAS UNrr 2 CYCLE II, REVISION 0 APRIL2004 Figure 5 Control Rod Insertion Limits* versus Power Level (23,259):122 Step Overlap (22,257): 120 Step Overlap (21, 255): 11 Step Overlap Yt (2 1, 253): 116 Step Overlap
)t v i u 14te r
(79,259): 122 Step Overlap (78.257): 120 Step Overlap (77,255): 1 1 8 Step Overlap (77,253): 116 Step Overlap (76; 25M:114 Ate ovri-1 260 240 220 200 180 c 160 cei o 140 0P 120 0
U 100 0
9 80 60 40 20 li I hI F FFT I II l
{1 l
(19 29):11 2Stcp^verap 2,_
(75, 249): 112 Step Ove
/ + I I II I1 -11 11
,, H I I II I II
<H~~~~~~~
' 1111111 I TII1_Xt "la 0
0 10 20 30 40 50 60 70 80 90 100 Rated Thermal Power (%)
'Control Bank A is already withdrawn to Full Out Position. Fully withdrawn region shall be the condition where shutdown and control banks are at a position within the interval of 249 and S259 steps withdrawn, inclusive.
Core Operating Limits Report Page 1IO
Alga&M J
SOUTH TEXAS UNIT 2 CYCLE II; REVISION 0 APRIL 2004 SOLTrH TEXAS UNIT 2 CYCLE 11 REVISION 0 APRIL2004 Figure 6 AED Limits versus Rated Thermal Power 120 100 1-1 O
P--
C04 sE
- .)
c c}
'c:
80 60 40 20 0
-50
-30
-10 10 30 50 Axial Flux Difference (Al) %
Core Operating Limits Report Page I I
&maU SoutnH TDxAs UNIT 2 CYCLE I 1, REVSIO 0 APRIL 2004 SourH TEXAS UNrr 2 CYCLE 11, REVISION 0 APRIL. 2004 Figure 7 K(Z) - Normalized FQ(Z) versus Core Height 1.2 1.0 N
Be IL 0
- .a C,
LL CD a) a)
N E
0Z
.8
.6
.4 Core Elevation (ft)
Fo K(Z) 0.0 2.55 1.0 7.0 2.55 1.0 14.0 2.359 0.925
.2 0
0.0 7.0 14.0 Core Height (ft)
Core Operating Limits Report Page 12
-CN-SOUTH TEXAS UNrr 2 CY=t I11, REvismO 0
APRIL2004 SouTH TEXAS UNrr 2 CYCLE 11, REVISION 0 APRIL2004 Table 1 (Part 1 of 2)
Unrodded F,, for Each Core Height for Cycle Burnups Less Than or Equal to 9000 MWVD/MTU Core Height (Ft.)
Axial Point Unrodded Fxy Core Height (Ft.)
Axial Point Unrodded Fxy 14.00 13.80 13.60 13.40 13.20 13.00 12.80 12.60 12.40 12.20 12.00 11.80 11.60 11.40 11.20 11.00 10.80 10.60 10.40 10.20 10.00 9.80 9.60 9.40 9.20 9.00 8.80 8.60 8.40 8.20 8.00 7.80 7.60 7.40 7.20 7.00 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 4.760 4.036 3.311 2.5871 2.249 2.032 2.046 2.033 2.025 2.014 1.995 1.981 1.974 1.970 1.966 1.963 1.962 1.964 1.966 1.972 1.977 1.981 1.989 1.998 2.008 2.019 2.030 2.042 2.054 2.063 2.069 2.067 2.061 2.051 2.031 2.020 6.80 6.60 6.40 6.20 6.00 5.80 5.60 5.40 5.20 5.00 4.80 4.60 4.40 4.20 4.00 3.80 3.60 3.40 3.20 3.00 2.80 2.60 2.40 2.20 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 2.015 2.007 2.003 1.999 1.997 1.996 1.995 1.995 1.994 1.989 1.984 1.976 1.969 1.963 1.959 1.952 1.946 1.941 1.940 1.934 1.927 1.905 1.874 1.834 1.795 1.759 1.728 1.729 1.723 1.737 1.905 2.218 2.604 2.990 3.376 Core Operating Limits Report Page 13
wor SOUTH TEXAS UNIT 2 CYCL.E I11, REmsmO 0 APRIL2004 SOUTH TEXAS UNrr 2 CYCLE 11, REVISION 0 APRIL2004 Table I (Part 2 of 2)
Unrodded Fxy for Each Core Height for Cycle Burnups Greater Than 9000 ANVD/IMTU Core Height (Ft.)
Axial Point Unrodded Fxy Core Height (Ft.)
Axial Point Unrodded Fxy 14.00 13.80 13.60 13.40 13.20 13.00 12.80 12.60 12.40 12.20 12.00 11.80 11.60 11.40 11.20 11.00 10.80 10.60 10.40 10.20 10.00 9.80 9.60 9.40 9.20 9.00 8.80 8.60 8.40 8.20 8.00 7.80 7.60 7.40 7.20 7.00 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 4.051 3.653 3.185 2.683 2.377 2.127 2.114 2.082 2.060 2.038 2.018 2.003 2.000 2.009 2.016 2.021 2.024 2.025 2.027 2.032 2.035 2.038 2.041 2.044 2.049 2.056 2.063 2.071 2.079 2.087 2.096 2.105 2.113 2.118 2.119 2.112 6.80 6.60 6.40 6.20 6.00 5.80 5.60 5.40 5.20 5.00 4.80 4.60 4.40 4.20 4.00 3.80 3.60 3.40 3.20 3.00 2.80 2.60 2.40 2.20 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00 37 38 39 40 41 42 43 44 45 46 47 48 49 50
'51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 2.103 2.093 2.082 2.071 2.059 2.048 2.037 2.029 2.021 2.014 2.005 1.996 1.986 1.977 1.967 1.957 1.948 1.939 1.931 1.923 1.915 1.898 1.879 1.854 1.844 1.835 1.829 1.839 1.839 1.851 1.993 2.249 2.541 2.764 2.796 Core Operating Limits Report Page 14
3/7 33 o 37 Nuclear Operating Company SOUTH TEXAS PROJECT UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT Revision 2 April 2004 I
a,-
SOUTH TEXAS UNIT I CYCLE 12 REV. 2 APRIL 2004 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report for STPEGS Unit 1 Cycle 12 has been prepared in accordance with the requirements of Technical Specification 6.9.1.6. The core operating limits have been developed using the NRC-approved methodologies specified in Technical Specification 6.9.1.6.
The Technical Specifications affected by this report are:
- 1) 2.1 SAFETY LIMITS
- 2) 2.2 LIMITING SAFETY SYSTEM SETTINGS
- 3) 3/4.1.1.1 SHUTDOWN MARGIN
- 4) 3/4.1.1.3 MODERATOR TEMPERATURE COEFFICIENT LIMITS
- 5) 3/4.1.3.5 SHUTDOWN ROD INSERTION LIMITS
- 6) 3/4.1.3.6 CONTROL ROD INSERTION LIMITS
- 7) 3/4.2.1 AFD LIMITS
- 8) 3/4.2.2 HEAT FLUX HOT CHANNEL FACTOR
- 9) 3/4.2.3 NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR
- 10) 3/4.2.5 DNB PARAMETERS 2.0 OPERATING LIMITS The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented below.
2.1 SAFETY LIMTS (Specification 2.1):
2.1.1 The combination of THERMAL POWER, pressurizer pressure, and the highest operating loop coolant temperature (Tavg) shall not exceed the limits shown in Figure 1.
2.2 LIMITING SAFETY SYSTEM SE¶TINGS (Specification 2.2):
2.2.1 The Loop design flow for Reactor Coolant Flow-Low is 98,000 gpm.
2.2.2 The Over-temperature AT and Over-power AT setpoint parameter values are listed below:
Core Operating Limits Report Page 2
SOtTH TExAS UNr I CYcLE 12 REv.2 APRIL2004 Over-temperature AT Setpoint Parameter Values measured reactor vessel AT lead/lag time constant,¶ 1= 8 sec T2 measured reactor vessel AT lead/lag time constant, T2 = 3 sec
¶3 measured reactor vessel AT lag time constant, T3 = 0 sec T4 measured reactor vessel average temperature lead/lag time constant, T4 = 28 sec Ts5 measured reactor vessel average temperature lead/lag time constant, T5 = 4 sec T6 measured reactor vessel average temperature lag time constant, T6 = 0 sec K1 Overtemperature AT reactor trip setpoint, K1 = 1.14 K2 Overtemperature AT reactor trip setpoint Tavg coefficient, K2 = 0.028/0F K3 Overtemperature AT reactor trip setpoint pressure coefficient, K3 = 0.00143/psig T'
NominalfullpowerTavg, T'
- 592.0°F P'
Nominal RCS pressure, P' = 2235 psig f1(AM) is a function of the indicated difference between top and bottom detectors of the power-range neutron ion chambers; with gains to be selected based on measured instrument response during plant startup tests such that:
(1)
For qt - qb between -70% and +8%, f1(AI) = 0, where q, and q, are percent RATED THERMAL POWER in the top and bottom halves of the core respectively, and q, + qb is total THERMAL POWER in percent of RATED THERMAL POWER; (2)
For each percent that the magnitude of q, - qb exceeds -70%, the AT Trip Setpoint shall be automatically reduced by 0.0% of its value at RATED THERMAL POWER.
(3)
For each percent that the magnitude of q, - qb exceeds +8%, the AT Trip Setpoint shall be automatically reduced by 2.65% of its value at RATED THERMAL POWER.
Over-power AT Setpoint Parameter Values I
measured reactor vesselAT lead/lag time constant, 1i = 8 sec T2 measured reactor vessel AT lead/lag time constant, T2 = 3 sec
¶r3 measured reactor vessel AT lag time constant, T3 = 0 sec T6 measured reactor vessel average temperature lag time constant, 6 = 0 sec
¶7 Time constant utilized in the rate-lag compensator for Tavg, 'r7 10 sec K4 Overpower AT reactor trip setpoint, K4 = 1.08 K5 Overpower AT reactor trip setpoint Tavg rate/lag coefficient, K5 = 0.02/°F for increasing average temperature, and Ks = 0 for decreasing average temperature K6 Overpower AT reactor trip setpoint Tavg heatup coefficient K6 = 0.002/°F for T > T" and, K6 = 0 for T < T" T"
Indicated full power Tavg, T"
- 592.0 IF f2(AI)
= 0 for all (Al) 2.3 SHUTDOWN MARGIN (Specification 3.1.1.1):
The SHUTDOWN MARGIN shall be:
2.3.1 Greater than 1.3% Ap for MODES 1 and 2*
- See Special Test Exception 3.10.1 2.3.2 Greater than the limits in Figure 2 for MODES 3 and 4.
2.3.3 Greater than the limits in Figure 3 for MODE 5.
Core Operating Limits Report Page 3
SomI rTEXAS UNUrI CYCLE 12 REV.2 APRm2004 2.4 MODERATOR TEMPERATURE COEFFICIENT (Specification 3.1.13):
2.4.1 The BOL, ARO, MTC shall be less positive than the limits shown in Figure 4.
2.4.2 The EOL, ARO, HFP, MTC shall be less negative than -62.72 pcm/0F.
2.4.3 The 300 ppm, ARO, HFP, MTC shall be less negative than -53.72 pcm/0F (300 ppm Surveillance Limit).
Where:
BOL stands for Beginning-of-Cycle Life, EOL stands for End-of-Cycle Life, ARO stands for All Rods Out, HFP stands for Hot Full Power (100% RATED THERMAL POWER),
HFP vessel average temperature is 592 IF.
2.4.4 The Revised Predicted near-EOL 300 ppm MTC shall be calculated using the algorithm from T.S. 6.9.1.6.b.10:
Revised Predicted MTC = Predicted MTC + AFD Correction - 3 pcm/0F If the Revised Predicted MTC is less negative than the S.R. 4.1.1.3b limit and all of the benchmark data contained in the surveillance procedure are met, then an MTC measurement in accordance with S.R. 4.1.1.3b is not required.
2.5 ROD INSERTION LIMITS (Specification 3.1.3.5 and 3.1.3.6):
2.5.1 All banks shall have the same Full Out Position (FOP) of at least 249 steps withdrawn but not exceeding 259 steps withdrawn.
2.5.2 The Control Banks shall be limited in physical insertion as specified in Figure 5.
2.5.3 Individual Shutdown bank rods are fully withdrawn when the Bank Demand Indication is at the FOP and the Rod Group Height Limiting Condition for Operation is satisfied (T.S. 3.1.3.1).
2.6 AXIAL FLUX DIFFERENCE (Specification 3.2.1):
2.6.1 AFD limits as required by Technical Specification 3.2.1 are determined by CAOC Operations with an AFD target band of +5, -10%.
2.6.2 The AFD shall be maintained within the ACCEPTABLE OPERATION portion of Figure 6, as required by Technical Specifications.
2.7 HEAT FLUX HOT CHANNEL FACTOR (Specification 3.2.2):
2.7.1 FQW = 2.55.
2.7.2 K(Z) is provided in Figure 7.
2.7.3 The Fxy limits for RATED THERMAL POWER (Fr-) within specific core planes shall be:
2.7.3.1 Less than or equal to 1.903 for cycle bumups less than or equal to 10500 MWD/MTU, and less than or equal to 2.102 for cycle burnups greater than 10500 MWD/MTU, for all core planes containing Bank "D" control rods, and 2.7.3.2 Less than or equal to the appropriate core height-dependent value from Table 1 for all unrodded core planes.
2.7.3.3 PFxy = 0.2.
Core Operating Limits Report Page 4
SouTh TEXAS UNIT I CYCLE 12 REv. 2 APRIL2004 These F,, limits were used to confirm that the heat flux hot channel factor FQ(Z) will be limited by Technical Specification 3.2.2 assuming the most-limiting axial power distributions expected to result for the insertion and removal of Control Banks C and D during operation, including the accompanying variations in the axial xenon and power distributions, as described in WCAP-8385.
Therefore, these F, limits provide assurance that the initial conditions assumed in the LOCA analysis are met, along with the ECCS acceptance criteria of 10 CFR 50.46.
2.8 ENTHALPY RISE HOT CHANNEL FACTOR (Specification 3.2.3):
2.8.1 FR = 1.5571 2.8.2 PFm = 0.3 2.9 DNB PARAMETERS (Specification 3.2.5):
2.9.1 The following DNB-related parameters shall be maintained within the following limits?
- a.
Reactor Coolant System Tavg, S. 595 oF3,
- b.
Pressurizer Pressure, > 2200 psig4,
- c.
Minimum Measured Reactor Coolant System Flow 2 403,000 gpm5.
3.0 REFERENCES
3.1 Letter from T. D. Croyle (Westinghouse) to D. F. Hoppes (STPNOC), "Unit I Cycle 12 Redesign Final Unbound Reload Evaluation," NF-TG-03-76 (ST-UB-NOC-03002399), July 7,2003.
3.2 NUREG-1346, Technical Specifications, South Texas Project UnitNos. 1 and 2.
3.3 STPNOC Calculation ZC-7035, Rev. 1, "Loop Uncertainty Calculation for RCS Tavg Instrumentation,"
October 19, 1998.
3.4 STPNOC Calculation ZC-7032, Rev. 3, "Loop Uncertainty Calculation for Narrow Range Pressurizer Pressure Monitoring Instrumentation," June 27, 2001.
I Applies to all fuel in the Unit I Cycle 12 core.
2 A discussion of the processes to be used to take these readings is provided in the basis for Technical Specification 32.5.
3 Includes a 1.9 'F measurement uncertainty per Reference 3.3.
4 Limit not applicable during either a Thermal Power ramp in excess of 5% of RTP per minute or a Thermal Power step in excess of 10% RTP. Includes a 10.7 psi measurement uncertainty as read on the QDPS display per Reference 3.4.
5 Includes a 2.8% flow measurement uncertainty.
Core Operating Limits Report Page 5
XSOUTH TEXAS UNIT I CYCL 12 RE. 2
.APRIL2004 SOUTH TEXAS UNIT 1 CYCLE 12 REV. 2 AP1uL2004 Figure 1 Reactor Core Safety Limits - FourLoops in Operation 680 660 640 v' 620 0
< 600 580 560 540 0
20 40 60 80 100 120 140 Power (% RTP)
Core Operating Limits Report Page 6
NF N SOUTH TExAs UNIT 1 CYcLE 12 REv. 2 APRIL2004 Figure 2 Required Shutdown Margin for Modes 3 & 4 8.0 7.0 6.0 CQ
.F_
C:
ej 5.0 I--
4.0 3.0 2.0 1.0 0.0 0
400 800 1200 1600 2000 2400 RCS Critical Boron Concentration (ppm)
(for ARI minus most reactive stuck rod)
Core Operating Limits Report Page 7
SOUrH TEXAS UNIT 1 CYCLE 12 REV. 2 APREL2004 Figure 3 Required Shutdown Margin for Mode 5 8.0 7.0 6.0
.am 0
C.
5.0 "4.0 3.0 I
2.0 1.0 0.0 0
400 800 1200 1600 2000 2400 RCS Critical Boron Concentration (ppm)
(for ARI minus most reactive stuck rod)
Core Operating Limits Report Page 8
i-A SoIrH TEXAS UNIT I cYcLE 12 REv. 2 APREL2004 Figure 4 MTCversus PowerLevel 7.0 6.0 5.0 E
c r-
,._U 1=
2-W 0
cub 2o U
E E-6a 4.0 3.0 2.0 1.0 0.0
-1.0
-2.0
-3.0 0
20 40 60 80 100 Power (% RTP)
Core Operating Limits Report Page 9
OCrC IW NMr-SOUrH TEXAS UNIT I CYCLE 12 REV. 2 APRIL2004 Figure 5 Control Rod Insertion Limits* versus Power Level 260 240 220 200 180 Q 160
.E 140 0P 120 0
c: 100 P=
0 9
80 60 40 20 0
I I I I I I I I I I I I I I I I I I I I I.
I II I
(23, 259): 122 Step Overlap (22, 257): 120 Step Overlap (21, 255): 1 1S Step Overlap (21, 253): 116 Step Overlap (20, 251): 114 Step Overlap i
]
. s x
(79,259):122 Step Overlap (78,257): 120 Step Overlap (77,255): I 9 Step Overlap (77, 253): 116 Step Overlap (76,251): 114 Step Overlap 1-t
-1n\\
-s P.
r lI II I I I I I I A 111111111411 i I i i I I i I IF V): I Step Overlap I
I I
I f
I V31 z4y): 1 it. wep Vvt I
I zi (0,2 F(100. 174)
Ar I
la
'00, OF' OF
- api 0
10 20 30 40 50 60 70 80 90 100 Rated Thermal Power (%)
- Control Bank A is already withdrawn to Full Out Position. Fully withdrawn region shall be the condition where shutdown and control banks are at a position within the interval of 249 and S 259 steps withdrawn, inclusive.
Core Operating Limits Report Page 10
__N N SouMH TEXAS UNIT I CYCLE 12 REV. 2 APRIL 2004 Figure 6 AFD Limits wrsus Rated Thermal Power 120 100
- -4 cs ck 80 60 40 20 0
-50
-30
-10 10 30 50 Axial Flux Difference (Al) %
Core Operating Limits Report Page I I
f SOUTH TEXAS UNIT 1 CYCLE 12 REV. 2 APRIL2004 Figure 7 K(Z) - Normalized FQ(Z) versus Core Height 1.2 1.0 L~
0 LL Cu N
r-a)
CL 0
co
.8
.6
.4
.2 0
0.0 7.0 14.0 Core Height (ft)
Core Operating Limits Report Page 12
A&MO
"-e SO NAr-SOUMTlEXAS UNrr I CYCLE 12 REV. 2 APRIL2004 SoLTrH TEXAS UNIT 1 CYcLE 12 REv. 2 APRIL2004 Table 1 (Part 1 of 2)
Unrodded FXy for Each Core Height For Cycle Burnups Less Than or Equal to 10500 MWD/MTU Core Height (Ft.)
Axial Point Unrodded Fxy Core Height (Ft.)
Axial Point Unrodded Fxy
+
14.0 13.8 13.6 13.4 13.2 13.0 12.8 12.6 12.4 12.2 12.0 11.8 11.6 11.4 11.2 11.0 10.8 10.6 10.4 10.2 10.0 9.8 9.6 9.4 9.2 9.0 8.8 8.6 8.4 8.2 8.0 7.8 7.6 7.4 7.2 7.0 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 4.122 3.613 3.104 2.594 2.290 2.049 2.053 2.038 2.022 1.995 1.974 1.962 1.959 1.959 1.956 1.951 1.946 1.944 1.942 1.947 1.952 1.957 1.965 1.972 1.980 1.989 2.000 2.011 2.021 2.030 2.034 2.024 2.005 1.986 1.964 1.952 6.8 6.6 6.4 6.2 6.0 5.8 5.6 5.4 5.2 5.0 4.8 4.6 4.4 4.2 4.0 3.8 3.6 3A 32 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 1.942 1.932 1.923 1.916 1.908 1.902 1.897 1.894 1.893 1.895 1.896 1.897 1.893 1.887 1.889 1.890 1.892 1.898 1.905 1.910 1.913 1.890 1.862 1.831 1.826 1.833 1.849 1.857 1.874 1.913 2.046 2.292 2.593 2.895 3.197 Core Operating Limits Report Page 13
XSourHTlExAs UNrr I CYCLE 12 REv. 2 APRiL2004 SotrrH TEXAS UNIT 1 CYCLE 12 REV. 2 APRIL2004 Table 1 (Part 2 of 2)
Unrodded Fxy for Each Core Height For Cycle Burnups Greater Than 10500 MWDJMTU Core Height (Ft.)
Axial Point Unrodded Fxy Core Height (Ft.)
Axial Point Unrodded Fxy 14.0 13.8 13.6 13.4 13.2 13.0 12.8 12.6 12.4 12.2 12.0 11.8 11.6 11.4 11.2 11.0 10.8 10.6 10.4 10.2 10.0 9.8 9.6 9.4 9.2 9.0 8.8 8.6 8.4 8.2 8.0 7.8 7.6 7.4 7.2 7.0 4
1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 4.784 4.133 3.481 2.829 2.436 2.124 2.107 2.080 2.054 2.028 1.998 1.996 2.001 2.008 2.015 2.020 2.025 2.027 2.029 2.033 2.039 2.045 2.052 2.059 2.066 2.071 2.074 2.078 2.082 2.088 2.095 2.105 2.116 2.127 2.136 2.139 6.8 6.6 6.4 6.2 6.0 5.8 5.6 5.4 5.2 5.0 4.8 4.6 4.4 4.2 4.0 3.8 3.6 3.4 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 2.137 2.131 2.117 2.103 2.089 2.078 2.068 2.059 2.050 2.041 2.032 2.021 2.009 1.997 1.983 1.970 1.957 1.945 1.934 1918 1.896 1.871 1.856 1.838 1.835 1.834 1.840 1.859 1.915 2.011 2.212 2.528 2.903 3.277 3.651 Core Operating Limits Report Page 14