ML041260238

From kanterella
Jump to navigation Jump to search
Units I and 2 - 2003 Occupational Radiation Exposure Report
ML041260238
Person / Time
Site: Catawba  Duke Energy icon.png
Issue date: 04/28/2004
From: Jamil D
Duke Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML041260238 (2)


Text

Pk Duke D.M. JAMIL Or Powere Vice President A Duke Energy Company Duke Power Catawba Nuclear Station 4800 Concord Rd. / CNO1VP York, SC 29745-9635 803 831 4251 803 831 3221 fax April 28, 2004 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555

Subject:

Catawba Nuclear Station, Units I and 2 Docket Nos. 50413 and 50-414 2003 Occupational Radiation Exposure Report Pursuant to Catawba Nuclear Station Technical Specification 5.6.1, the 2003 Occupational Radiation Exposure Report for Catawba Nuclear Station is attached.

This report is submitted in accordance with 10 CFR 50.4 and provides a tabulation of the number of station, utility, and other personnel (including contractors) receiving exposure greater than 100 mRem/year followed by the total dose of each respective worker classification and job function during the 2003 calendar year. Special maintenance work included miscellaneous valve replacement, an auxiliary emergency core cooling system ventilation modification, a steam generator rat hole modification, an inspection of the spent resin storage tank screens, and other miscellaneous small modifications.

Any questions concerning this report should be directed to Kay Nicholson at 803.831.3237.

Sincerely, Dhiaa M. Jamil Attachment

\\2003 ORER xc:

L. A. Reyes, Regional Administrator, Region II S. E. Peters, NRR Project Manager E. F. Guthrie, Senior Resident Inspector www. duke-energy. corn

DUKE POWER COMPANY -

CATAWBA NUCLEAR STATION TABULATION OF NUMBER OF PERSONNEL AND PERSON-REM BY WORK AND JOB FUNCTION FOR 2003 DATE: 03/10/04 NUMBER OF PERSONNEL(>100 MREM)

TOTAL PERSON-REM(>100 MREM)

WORK AND JOB FUNCTION STATION UTILITY CONTRACT WORKERS STATION UTILITY CONTRACT WORKERS EMPLOYEES EMPLOYEES AND OTHERS EMPLOYEES EMPLOYEES AND OTHERS

    • IN-SERVICE INSPECTION ENGINEERING 4

1 0

0.143 0.005 0.000 HEALTH PHYSICS 3

0 19 0.004 0.000 0.357 MAINTENANCE 35 15 141 0.869 0.882 15.016 OPERATING 46 0

6 3.247 0.000 0.075 SUPERVISION 8

8 20 0.975 1.556 2.848

    • REACTOR OPERS. I SURVEILLANCE ENGINEERING 13 1

1 0.710 0.046 0.125 HEALTH PHYSICS 11 0

57 1.862 0.000 5.508 MAINTENANCE 151 52 276 2.183 1.118 2.512 OPERATING 76 0

36 12.207 0.000 0.711 SUPERVISION 12 7

23 0.132 0.023 0.067

    • REFUELING ENGINEERING 4

0 0

0.402 0.000 0.000 HEALTH PHYSICS 2

0 13 0.023 0.000 0.369 MAINTENANCE 60 23 48 4.903 2.828 1.995 OPERATING 1

0 15 0.107 0.000 0.187 SUPERVISION 4

2 8

0.187 0.004 0.182

    • ROUTINE MAINTENANCE ENGINEERING 12 1

0 1.192 0.071 0.000 HEALTH PHYSICS 11 0

55 0.783 0.000 4.996 MAINTENANCE 155 52 335 27.601 9.311 71.791 OPERATING 1

71 0

75 1.049 0.000 17.901 SUPERVISION 12 7

26 1.242 0.231 2.813

    • SPECIAL MAINTENANCE ENGINEERING 8

0 0

0.179 0.000 0.000 HEALTH PHYSICS 9

0 11 0.159 0.000 0.307 MAINTENANCE 49 25 109 0.682 0.769 7.093 OPERATING 11 0

12 0.153 0.000 0.236 SUPERVISION 6

5 7

0.033 0.012 0.093

    • WASTE PROCESSING ENGINEERING 0

0 0

0.000 0.000 0.000 HEALTH PHYSICS 7

0 14 0.154 0.000 0.332 MAINTENANCE 5

2 5

0.004 0.007 0.022 OPERATING 1

0 34 0.005 0.000 0.288 SUPERVISION 1

0 2

0.000 0.000 0.011

    • TOTAL ENGINEERING 13 1

1 2.626 0.122 0.125 HEALTH PHYSICS 11 0

57 2.985 0.000 11.869 MAINTENANCE 1H5 5S 1335 36.242 14.915 98.429 OAINGA76 0

75 16.768 0.000 19.398 SUPERVISION 12 8

27 2.569 1.826 6.014 GRAND TOTAL 267 61 495 61.190 16.863 135.835 STATION TOTAL DOSE FOR 2003 WAS 211 PERSON-REM (TLD)