April 8, 2004 Mr. L. M. Stinson Vice President Southern Nuclear Operating Company Post Office Box 1295 Birmingham, Alabama 35201
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE JOSEPH M. FARLEY NUCLEAR PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION
Dear Mr. Stinson:
By letter dated September 12, 2003, Southern Nuclear Operating Company, Inc. (SNC or the applicant) submitted an application pursuant to 10 CFR Part 54, to renew the operating licenses for Joseph M. Farley Nuclear Plant (FNP), Units 1 and 2, for review by the U.S. Nuclear Regulatory Commissions (NRC). The NRC staff is reviewing the information contained in the license renewal application (LRA) and has identified, in the enclosure, areas where additional information is needed to complete the review. Specifically, the enclosed request for additional information (RAI) is from Section 3.0, Aging Management Review Results.
This RAI, in a draft format, has been provided to Mr. Jan Fridrichsen of your staff on March 30, 2004. The NRC staff has discussed draft versions of this RAI, via a conference call, to provide clarifications to the SNC staff on April 7, 2004. Your response to this RAI is requested within 30 days from the date of this letter. Mr. Fridrichsen has agreed to this request.
If needed, the NRC staff is willing to meet or discuss with SNC again prior to the submittal of the applicants response to provide clarifications to the staffs RAI.
If you have any questions, please contact me at 301-415-1315 or e-mail tyl1@nrc.gov.
Sincerely,
/RA/
Tilda Liu, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-348 and 50-364
Enclosure:
As stated cc w/encl: See next page
April 8, 2004 Mr. L. M. Stinson Vice President Southern Nuclear Operating Company Post Office Box 1295 Birmingham, Alabama 35201
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE JOSEPH M. FARLEY NUCLEAR PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION
Dear Mr. Stinson:
By letter dated September 12, 2003, Southern Nuclear Operating Company, Inc. (SNC or the applicant) submitted an application pursuant to 10 CFR Part 54, to renew the operating licenses for Joseph M. Farley Nuclear Plant (FNP), Units 1 and 2, for review by the U.S. Nuclear Regulatory Commissions (NRC). The NRC staff is reviewing the information contained in the license renewal application (LRA) and has identified, in the enclosure, areas where additional information is needed to complete the review. Specifically, the enclosed request for additional information (RAI) is from Section 3.0, Aging Management Review Results.
This RAI, in a draft format, has been provided to Mr. Jan Fridrichsen of your staff on March 30, 2004. The NRC staff has discussed draft versions of this RAI, via a conference call, to provide clarifications to the SNC staff on April 7, 2004. Your response to this RAI is requested within 30 days from the date of this letter. Mr. Fridrichsen has agreed to this request.
If needed, the NRC staff is willing to meet or discuss with SNC again prior to the submittal of the applicants response to provide clarifications to the staffs RAI.
If you have any questions, please contact me at 301-415-1315 or e-mail tyl1@nrc.gov.
Sincerely,
/RA/
Tilda Liu, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-348 and 50-364
Enclosure:
As stated cc w/encl: See next page DISTRIBUTION: See next page Accession Number: ML041000295 C:\\ORPCheckout\\FileNET\\ML041000295.wpd OFFICE LA:RLEP PM:RLEP SC:DE/EMEB/A SC:RLEP NAME YEdmonds TLiu DTerao SLee DATE 4/8/04 4/8/04 4/7/04 4/8/04 OFFICIAL RECORD COPY
DISTRIBUTION: Ltr. to L.M. Stinson, Re: J.M. Farley, Dated: April 8, 2004 ML041000295 HARD COPY RLEP RF T. Liu (PM)
D. Chen J. Strnisha E-MAIL:
PUBLIC J. Craig D. Matthews F. Gillespie C. Grimes RidsNrrDe E. Imbro G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins P. Shemanski J. Fair S. Black B. Boger D. Thatcher R. Pettis G. Galletti C. Li M. Itzkowitz R. Weisman M. Mayfield A. Murphy S. Smith (srs3)
S. Duraiswamy Y. L. (Renee) Li RLEP Staff C. Julian (R-II)
R. Fanner (R-II)
C. Patterson (R-II)
S. Peters L. Whitney R. Hoefling (OGC)
JOSEPH M. FARLEY NUCLEAR PLANT (FNP), UNITS 1 AND 2 LICENSE RENEWAL APPLICATION (LRA)
REQUEST FOR ADDITIONAL INFORMATION (RAI)
Section 3.2: Aging Management of Engineered Safety Features Systems Section 3.3: Aging Management of Auxiliary Systems Section 3.4: Aging Management of Steam and Power Conversion Systems RAI 3.2-7 (This RAI is related to engineered safety features, auxiliary, and/or steam and power conversion systems)
The Bolting Integrity program in Section XI-M18 of NUREG-1801 addresses the aging effects of cracking and loss of preload (stress relaxation) for closure bolting. Cracking is considered an aging effect requiring management (AERM) for high strength bolts where the actual yield strength of the material is equal or greater than 150 ksi and stress relaxation is considered an AERM for bolts in high temperature applications. The LRA Tables 3.2.2-X, 3.3.2-X, and 3.4.2-X do not address cracking or stress relaxation for these conditions. The applicant is requested to discuss if any bolting in the engineered safety features, auxiliary systems, and/or steam and power conversion systems meet these conditions and provide appropriate aging management.
Enclosure
Joseph M. Farley Nuclear Plant cc:
Mr. Don E. Grissette General Manager - Plant Farley Southern Nuclear Operating Company Post Office Box 470 Ashford, AL 36312 Mr. B. D. McKinney Licensing Manager Southern Nuclear Operating Company 40 Inverness Center Parkway Post Office Box 1295 Birmingham, AL 35201-1295 Mr. Stanford M. Blanton, esq.
Balch and Bingham Law Firm Post Office Box 306 1710 Sixth Avenue North Birmingham, AL 35201 Mr. J. B. Beasley, Jr.
Executive Vice President Southern Nuclear Operating Company 40 Inverness Center Parkway Post Office Box 1295 Birmingham, AL 35201 Dr. D. E. Williamson State Health Officer Alabama Department of Public Health The RSA Tower 201 Monroe Street, Suite 1500 Montgomery, AL 36130-1701 Chairman Houston County Commission Post Office Box 6406 Dothan, AL 36302 Mr. William D. Oldfield SAER Supervisor Southern Nuclear Operating Company Post Office Box 470 Ashford, AL 36312 Mr. Charles R. Pierce Manager - License Renewal Southern Nuclear Operating Company 40 Inverness Center Parkway Post Office Box 1295 Birmingham, AL 35201 Mr. Fred Emerson Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Resident Inspector U.S. Nuclear Regulatory Commission 7388 N. State Highway 95 Columbia, AL 36319