April 8, 2004 Mr. Jeff Forbes Vice President, Operations ANO Entergy Operations, Inc.

1448 S. R. 333 Russellville, AR 72801

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE ARKANSAS NUCLEAR ONE, UNIT 2, LICENSE RENEWAL APPLICATION (TAC NO. MB8402)

Dear Mr. Forbes:

The U.S. Nuclear Regulatory Commission (NRC) is reviewing a license renewal application (LRA) submitted by Entergy Operators Inc. (Entergy or the applicant) dated October 14, 2003 for the renewal of the operating licenses for Arkansas Nuclear One, Unit 2, pursuant to Title 10 Code of Federal Regulations Part 54 (10 CFR Part 54). The NRC staff has identified, in the enclosure, areas where additional information is needed to complete the review. Specifically, the enclosed requests for additional information (RAIs) are from Section 2.1 Scoping and Screening Methodology and Section 2.3 System Scoping and Screening Results: Mechanical.

These RAIs have been discussed with your staff.

Your responses to these RAIs are requested within 30 days from the receipt of this letter. If you have any questions, please contact me at (301) 415-1124 or e-mail gxs@nrc.gov.

Sincerely,

/RA/

Gregory F. Suber, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No.: 50-368

Enclosure:

As stated cc w/encl: See next page

April 8, 2004 Mr. Jeff Forbes Vice President, Operations ANO Entergy Operations, Inc.

1448 S. R. 333 Russellville, AR 72801

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE ARKANSAS NUCLEAR ONE, UNIT 2, LICENSE RENEWAL APPLICATION (TAC NO. MB8402)

Dear Mr. Forbes:

The U.S. Nuclear Regulatory Commission (NRC) is reviewing a license renewal application (LRA) submitted by Entergy Operators Inc. (Entergy or the applicant) dated October 14, 2003 for the renewal of the operating licenses for Arkansas Nuclear One, Unit 2, pursuant to Title 10 Code of Federal Regulations Part 54 (10 CFR Part 54). The NRC staff has identified, in the enclosure, areas where additional information is needed to complete the review. Specifically, the enclosed requests for additional information (RAIs) are from Section 2.1 Scoping and Screening Methodology and Section 2.3 System Scoping and Screening Results: Mechanical.

These RAIs have been discussed with your staff.

Your responses to these RAIs are requested within 30 days from the receipt of this letter. If you have any questions, please contact me at (301) 415-1124 or e-mail gxs@nrc.gov.

Sincerely,

/RA/

Gregory F. Suber, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No.: 50-368

Enclosure:

As stated cc w/encl: See next page DISTRIBUTION: See next page Accession No: ML040990230 Document Name: C:\\ORPCheckout\\FileNET\\ML040990230.wpd OFFICE:

LA:RLEP PM:RLEP SC:RLEP NAME:

MJenkins GSuber SLee DATE:

4/6/04 4/5/04 4/8/04 OFFICIAL RECORD COPY

Attachment REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE SCOPING AND SCREENING REVIEW OF THE ARKANSAS NUCLEAR ONE - UNIT 2 LICENSE RENEWAL APPLICATION (TAC NO. MB8402)

Division of Systems Safety and Analysis (DSSA)

RAI 2.3-1 Section 2.1.1 states the following with respect to the scoping methodology for the Heating, Ventilation, and Air Conditioning (HVAC) Systems: "Consistent with NEI 95-10, the scoping process used for the ANO-2 license renewal project began with a list of plant systems and structures, determined the functions they perform, and then determined which functions met any of the three criteria of 10 CFR 54.4(a). Functions that meet any of the criteria are intended functions for license renewal, and the systems and structures that perform these functions are included within the scope of license renewal." In order for the staff to determine that you have not omitted any structures, systems, and components that should be within the scope of license renewal according to 10 CFR 54.4(a), describe the details of the process used to confirm whether you have included all the structures, systems, and components in such systems and structures within the scope of license renewal.

RAI 2.3-2 In the preface to the LRA on Page 1 it is stated in the third paragraph that, "....the Tables provide a reference to the results of the aging management review for each component and commodity type. The descriptions of systems in Section 2 identify license renewal drawings that document the components subject to aging management review for mechanical systems.

The drawings are provided in a separate submittal."

Also, in Section 2.1.1, "Scoping Methodology," you have stated that, "License renewal drawings were prepared to indicate components subject to aging management review. Components that are subject to aging management review based only on the criterion of 10CFR54.4(a)(2) are not indicated on the drawings."

In order for the staff to determine that you have not omitted any structures, systems, and components that should be within the scope of license renewal according to 10 CFR 54.4(a),

describe the process used to confirm whether you have included all the structures, systems, and components in the scope of license renewal for the HVAC Systems.

RAI 2.3-3 The staff requests that the applicant:

a.

Clarify whether the sealants used on the main control room envelope (MCRE) to prevent unfiltered inleakages are included in the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an aging management review in accordance with 10 CFR 54.21(a)(1). If so, provide the relevant information to complete Table 2.3.3.10. Additionally, does structural sealants ("Elastomers"),

as listed in Table 2.4-4 of the LRA, include the MCRE ductwork and component housing sealants ? If the sealants are not considered subject to an AMR, provide justification for their exclusion.

b.

Clarify whether sealants used as a pressure boundary function for the auxiliary building ventilation system are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an aging management review in accordance with 10 CFR 54.21(a)(1). If they are, provide the relevant information about the sealants to complete Table 2.3.3.9. If the sealants are excluded from the scope of license renewal and not subject to an AMR, provide justification for this exclusion.

RAI 2.3-4 It seems that the penetration rooms ventilation system (see ANO-2 FSAR Section 6.5, "Penetration Rooms Ventilation System") is excluded from the license renewal application. If it is addressed as part of other ventilation systems, provide related information for the penetration rooms ventilation system components that are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an aging management review in accordance with 10 CFR 54.21(a)(1) or provide justification for the exclusion of the penetration rooms ventilation system from the LRA.

Additionally, provide the relevant information in the AMR table about the penetration room sealant materials use for a pressure boundary function that are within the scope of the license renewal in accordance with 10 CFR 54.4(a) and subject to an aging management review in accordance with 10 CFR 54.21(a)(1) or provide justification for its exclusion.

RAI 2.3-5 Table 2.3.2-5 for Hydrogen Control System Components Subject to Aging Manangement Review does not list Separators 2F-254 and 2F-256 shown on ANO-2 piping and instrument diagram LRA-M-2261 Sheet 3, as components requiring an AMR. Please identify where the LRA addresses the AMR of these components or provide a justification for excluding these components from an AMR.

DISTRIBUTION: Ltr. to Jforbes, Re: ANO-2, Dated: April 8, 2004 ML040990230 HARD COPY RLEP RF Project Manager E-MAIL:

PUBLIC J. Craig D. Matthews F. Gillespie C. Grimes RidsNrrDe E. Imbro G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins P. Shemanski J. Fair S. Black B. Boger D. Thatcher R. Pettis G. Galletti C. Li M. Itzkowitz R. Weisman M. Mayfield A. Murphy S. Smith (srs3)

S. Duraiswamy Y. L. (Renee) Li RLEP Staff J. Minns R. Gramm A. Howell T. Alexion Linda Smith RIV

Arkansas Nuclear One, Unit 2 cc:

Executive Vice President

& Chief Operating Officer Entergy Operations, Inc.

P. O. Box 31995 Jackson, MS 39286-1995 Director, Division of Radiation Control and Emergency Management Arkansas Department of Health 4815 West Markham Street, Slot 30 Little Rock, AR 72205-3867 Winston & Strawn 1400 L Street, N.W.

Washington, DC 20005-3502 Mr. Mike Schoppman Framatome ANP, Richland, Inc.

Suite 705 1911 North Fort Myer Drive Rosslyn, VA 22209 Senior Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 310 London, AR 72847 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 County Judge of Pope County Pope County Courthouse Russellville, AR 72801 Vice President, Operations Support Entergy Operations, Inc.

P. O. Box 31995 Jackson, MS 39286-1995 Wise, Carter, Child & Caraway P. O. Box 651 Jackson, MS 39205 Garry Young 1448 SR 333 Russellville, AR 72802 Mr. Fred Emerson Nuclear Energy Institute 1776 I St., N.W., Suite 400 Washington, DC 20006-3708