Containment Penetrations 3.9.3.

3.9 REFUELING OPERATIONS 3.9.3 Containment Penetrations LCO 3.9.3 The containment penetrations shall be in the following status:

a.

The equipment hatch closed and held in place with all bolts;

b.

One door in each air lock is capable of being closed; 'and

c.

Each Containment Purge and Exhaust System penetration either:

1.

closed by a manual or automatic isolation valve, blind flange, or equivalent, or

2.

capable of being closed by an OPERABLE Containment Purge and Exhaust Isolation System.

APPLICABILITY:

During movement of recently irradiated fuel assemblies within containment.

I ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more A.1 Suspend movement of Immediately containment recently irradiated fuel penetrations not in assemblies within required status.

containment.

Point Beach 3.9.3-1 Unit I - Amendment No. 213 Unit 2 - Amendment No. 218