ML040850577

From kanterella
Jump to navigation Jump to search
Summary of Technical Staff Meeting to Discuss Previous Condition at Oconee Nuclear Station Water Discovered in Bearing Lubricating Oil for Standby Shutdown Facility Auxiliary Service Water (Asw) Pump
ML040850577
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 03/25/2004
From: Haag R
NRC/RGN-II/DRP/RPB1
To: Rosalyn Jones
Duke Energy Corp
References
Download: ML040850577 (6)


Text

March 25, 2004 Duke Energy Corporation ATTN:

Mr. R. A. Jones Vice President Oconee Nuclear Station 7800 Rochester Highway Seneca, SC 29672

SUBJECT:

MEETING

SUMMARY

- OCONEE NUCLEAR STATION DOCKET NOS. 50-269, 50-270, 50-287

Dear Mr. Jones:

This refers to the technical staff meeting that was conducted at the Region II Office on March 11, 2004, to discuss a previous condition at the Oconee Nuclear Station where water was discovered in the bearing lubricating oil for the standby shutdown facility auxiliary service water (ASW) pump. A list of attendees is enclosed.

It is our opinion that this meeting was beneficial in that it provided the NRC staff with your understanding of how water entered into the ASW pump bearing housing as well as the details of the proposed test to substantiate your position that the ASW pump would have been capable of performing its safety function in the as found condition.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice", a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS).

ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this meeting, please contact us.

Sincerely,

/RA/

Robert C. Haag, Chief Reactor Projects Branch 1 Division of Reactor Projects Docket Nos. 50-269, 50-270, 50-287 License Nos. DPR-38, DPR-47, DPR-55

Enclosure:

List of Attendees

DEC 2

cc w/encl:

B. G. Davenport Compliance Manager (ONS)

Duke Energy Corporation Electronic Mail Distribution Lisa Vaughn Legal Department (PB05E)

Duke Energy Corporation 422 South Church Street Charlotte, NC 28242 Anne Cottingham Winston and Strawn Electronic Mail Distribution Beverly Hall, Acting Director Division of Radiation Protection N. C. Department of Environmental Health & Natural Resources Electronic Mail Distribution Henry J. Porter, Director Div. of Radioactive Waste Mgmt.

S. C. Department of Health and Environmental Control Electronic Mail Distribution R. Mike Gandy Division of Radioactive Waste Mgmt.

S. C. Department of Health and Environmental Control Electronic Mail Distribution County Supervisor of Oconee County 415 S. Pine Street Walhalla, SC 29691-2145 Lyle Graber, LIS NUS Corporation Electronic Mail Distribution R. L. Gill, Jr., Manager Nuclear Regulatory Licensing Duke Energy Corporation 526 S. Church Street Charlotte, NC 28201-0006 Peggy Force Assistant Attorney General N. C. Department of Justice Electronic Mail Distribution

DEC 3

Distribution w/encl:

L. Olshan, NRR RIDSNRRDIPMLIPB PUBLIC OFFICE RII:DRP SIGNATURE MEP2 NAME M Pribish DATE 3/24/2004 E-MAIL COPY?

YES NO YES NO YES NO YES NO YES NO YES NO YES NO PUBLIC DOCUMENT YES NO OFFICIAL RECORD COPY DOCUMENT NAME: C:\\ORPCheckout\\FileNET\\ML040850577.wpd

Enclosure LIST OF ATTENDEES Duke Energy Corporation P. Fisk, Rotating Equipment Supervisor, Oconee Nuclear Station (ONS)

R. Henderson, Rotating Equipment Engineer, ONS A. Washburn, Senior Field Engineer, Sulzer Pumps Nuclear Regulatory Commission R. Carroll, Senior Project Engineer, Branch 1, Division of Reactor Projects (DRP)

R. Haag, Chief, Branch 1, DRP L. Moore, Senior Reactor Inspector, Division of Reactor Safety (DRS)

L. Olshan, Office of Nuclear Reactor Regulation (NRR)

W. Poertner, NRR M. Shannon, Senior Resident Inspector, Oconee