ML040690577

From kanterella
Jump to navigation Jump to search
Notification of Spent Fuel Shipment
ML040690577
Person / Time
Site: Robinson 
Issue date: 06/18/2003
From: Burton C
Progress Energy Carolinas
To: Dalton M, Porter H
Office of Nuclear Reactor Regulation, State of NC, Highway Patrol, State of SC, Dept of Health & Environmental Control
References
RNP-RA/03-0082
Download: ML040690577 (4)


Text

6 0ArEGUARDS lNFOMATli 05o ooo6 iowY Cj Progress Energy ESPONSIBlE DEPARTMENT.

t C.

';LANT/SECT0ON _-f'

/7R~

5"r 10 CFR 73.37 10 CFR 73.21 Serial: RNP-RA/03-0082 JUN 1 8 2003 Mr. Henry Porter Assistant Director, Division of Waste Management Bureau of Land and Waste Management Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Line Sergeant Mark Dalton Hazardous Materials Coordinator North Carolina State Highway Patrol Headquarters Research and Planning Section 4702 Mail Service Center Raleigh, North Carolina 276994702 SGI No. SCN.0--0.31 b I,0-3 COPY OF

-- 7 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 NOTIFICATION OF SPENT FUEL SHIPMENT Gentlemen:

In accordance with 10 CFR 73.37, Carolina Power and Light (CP&L) Company, now doing business as Progress Energy Carolinas, provides the following information concerning a forthcoming shipment of irradiated nuclear reactor fuel.

1.

Name, Address, and Telephone Number of Shipper, Carrier, and Receiver

a.

Shipper: H. B. Robinson Steam Electric Plant (HBRSEP), Unit No. 2 Docket No. 50-261 3581 West Entrance Road Hartsville, SC 29550 (843) 857-1279/1278

,~AN-

6) hul Progress Energy Carolinas. Inc.

Rot.i:mson Nuclear P13an1

.1-81 WVest Entrance Road 9itsvil*o, SC 29550 SEARATED FROM ENCLOSURE

\\ ANDLE THIS DOCUMENT AS DECONTROLLE WArECUAnDS IRFORMATPON

OSOaoacIqooy Department of Health and Environmental Control North Carolina State Highway Patrol Headquarters Serial: RNP-RA/03-0082 Page 2 of 4

1. Name, Address, and Telephone Number of Shipper, Carrier, and Receiver (continued)
b.

Carrier: CSX Transportation Chief Dispatcher 3019 Warrington Street Jacksonville, FL 32205 (904) 381-2780

c.

Receiver: Harris Nuclear Plant (HNP)

Docket No. 50400 Post Office Box 165 New Hill, NC 27562 (919) 362-2157

2.

Description of Shipment - Radioactive material in IF-300 series shipping cask(s): Cask ID No. USA/9001/B(F; s/n IF-301, s/n IF-302.

a.

Cask(s) used this shipment: IF-301 and IF-302

b.

Proper Shipping Name: Radioactive Material, Fissile, N.O.S., RQ

c.

DOT Hazard Class: 7

d.

DOT ID No: UN2918

e.

DOT Subtype: Highway Route Controlled Quantity

f.

Mode of Shipment: Rail

g.

Physical Form: Solid

h.

Chemical Form: Plutonium Oxide and Uranium Oxide

i.

"Exclusive Use Shipment"

j.

Radionuclides: Pu-238, Pu-241, Ba-137m, Am-241, Cm-244, Pu-240, Pu-239, Sr-90, Rh-106, Pr-144

k.

Original Enrichment:

IF-301 IF-302

l.

Hazardous Material Quantity:IF-301 IF-302

m.

Total Curie Content:

EF-301 IF-302 4.25 w/o 4.25 w/o 9630 lbs.

9630 lbs.

1.416 E 6 1.415 E 6 15 15 ctive Yellow III

n.

Transport Index:

o.

Category of Label:

p.

Type of Reactor:

IF-301 IF-302 Radioa PWR

Department of Health and Environmental Control North Carolina State Highway Patrol Headquarters Serial: RNP-RA/03-0082 Page 3 of 4

3.

Route Within the States of North Carolina and South Carolina

a.

HBRSEP, Unit No. 2, to McBee, SC: CSX Railroad

b.

McBee, SC to Hamlet, NC: CSX Railroad

c.

Hamlet, NC to HNP: CSX Railroad By copy of this correspondence, the Nuclear Regulatory Commission is provided notification of this shipment. In accordance with 10 CFR 73.21 and 10 CFR 73.37, the information on the attachment is designated as Safeguards Information and shall be protected in accordance with the provisions of 10 CFR 73.21.

Questions regarding this matter may be referred to Mr. C. T. Baucom.

Sincerely, C. L. Burton Director - Site Operations, HBRSEP, Unit No. 2 CAC/cac Attachment

0-50 0 o 0

Department of Health and Environmental Control North Carolina State Highway Patrol Headquarters Serial: RNP-RA/03-0082 Page 4 of 4 C:

(1)

US Nuclear Regulatory Commission, Director, Division of Nuclear Security Office of Nuclear Security and Incident Response Attn: Ms. Gloria Bennington USNRC NSIR: DNS:M/S: T-4 D-8 11545 Rockville Pike Rockville, MD 20852-2738 (2)

US Nuclear Regulatory Commission, Director, Division of Nuclear Security Office of Nuclear Security and Incident Response Attn: Ms. Gloria Bennington M/S: T4-D8 Washington DC 20555-0001 (3)

Corporate Security Attn: -Lori Hayes OHS-8B4 412 South Wilmington Street Raleigh, NC 27601 (4)

RNP, Plant Vault 3581 West Entrance Road Hartsville, SC 29550 (5)

Mr. Denny Braund Harris Nuclear Plant 5413 Shearon Harris Road New Hill, NC 27562