Text
Feb. 20, 2004 Page 1
of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2004-7942 USER INFORMATION:
LACH*ROS EMPL#:28401 CA#: 0363 Addr UCSA2 P
e :2 14 TRANSMITTAL INFORMATION:
TO:
02/20/2004 LOCATION:r-USNRC-)
FROM:
NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)
THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:
TRM1 -
TECHNICAL REQUIREMENTS MANUAL UNIT 1 REMOVE MANUAL TABLE OF CONTENTS DATE: 02/10/2004 ADD MANUAL TABLE OF CONTENTS DATE: 02/19/2004 CATEGORY: DOCUMENTS TYPE: TRM1 ID:
TEXT 3.11.2.1 REPLACE:
REV:1 UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
f15D
Dose Rate 3.11.2.1 PPL Rev. 1 3.11 Radioactive Effluents 3.11.2 Gaseous Effluents 3.11.2.1 Dose Rate TRO 3.11.2.1 The dose rate due to radioactive materials released in gaseous effluents to areas at and beyond the SITE BOUNDARY (See FSAR Section 2.1.1.3) shall be limited to the following:
I.
For Noble Gases:
A.
Less than or equal to 500 mrems/yr to the total body, and B.
Less than or equal to 3000 mrems/yr to the skin AND II.
For iodine-131, iodine-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days A.
Less than or equal to 1500-mrem/yr to any organ (Inhalation pathways only.)
APPLICABI LITY:
At all times.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
Dose rate(s) exceed A.1 Restore the release rate Immediately the above limits to within the above limits SUSQUEHANNA - UNIT 1 3.1 1-17 EFFECTIVE DATE 8/31/1998
Dose Rate PPL Rev. 1 3.11.2.1 TECHNICAL REQUIREMENT SURVEILLANCE SURVEILLANCE FREQUENCY TRS 3.11.2.1.1 Determine the dose rate due to noble See ODCM gases in gaseous effluents.
TRS 3.11.2.1.2 The dose rate due to iodine-131, iodine-See Table 133, tritium, and all radionuclides in 3.11.2.1-1 particulate form with half-lives greater than 8 days in gaseous effluents shall
'be determined to be within the limits in accordance with the methodology and parameters of the ODCM by obtaining representative samples and performing analyses in accordance with the sampling and analysis program specified in Table 3.11.2.1-1 SUSQUEHANNA - UNIT I 3.1 1-18 EFFECTIVE DATE 8/31/1998
~ '-
PPL Rev. 1
- Dose Rate 3.11.2.1 TABLE 3.11.2.1-1 RADIOACTIVE GASEOUS EFFLUENT SAMPLING AND ANALYSIS Sampling Lower Limit of Method and Minimum Detection (LLD)
Gaseous Release Type Frequency Analysis Type of Activity (p~cimi)
-Frequency Analysis A, Containment Purge Prior to each purge Prior to each Principal Noble IE-4 Grab Sample purge Gas Gamma Emitters H-3 1E-6 B. Reactor Building 31 daysca) 31 days<')
Principal Noble 1E4 Vents, Turbine Grab Sample -
Gas Gamma Building Vents, Emitters and SGTS H-3 I E-6 Continuous"b Iodine 7 days(c) 1-131 1E-12 Cartridge Sample -
1-133 1E-10 Continuous~b) 7 days<)
Principal 1E-11 Particulate Gamma Particulate sample Emitters 1-131 Continuous~b 92 days Gross Alpha IE-11 Composites' Particulate Sample Continuous° 92 days Sr-89, Sr-90 IE-11 Composite Particulate sample, ContinuousO Noble Gas Noble Gases, Gross 12E-Monitor Beta or Gamma (Xe-133 equivalent)
(a) Noble gas analyses shall be performed following shutdown, startup, or a THERMAL POWER change exceeding 15% of the RATED THERMAL POWER within a 1-hour period.
(b)
The ratio of the sample flow rate to the sampled stream flow rate shall be known for the time period covered by each dose or dose rate calculation made in accordance with TROs 3.11.2.1, 3.11.2.2, and 3.11.2.3.
Samples shall be changed at least once per 7 days and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after changing, or after removal from sampler. Sampling shall also be performed at least-once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for at least 7 days following each shutdown, startup, or THERMAL POWER change exceeding 15% of RATED THERMAL POWER in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, and analyses completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of changing. When samples collected for s 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> are analyzed, the corresponding LLDs may be increased by a factor of 10.
(d) Minimum frequency for initiation of required analysis.
I' SUSQUEHANNA - UNIT 1 TRM / 3.1 1-19 EFFECTIVE DATE 01/21/2004