Text
Peripheral Oxide Utility:
Comanche Peak 2 Assembly: JJ23 Face:
3 Date:
15-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 6.2 8.8 9.0 11.0 8.9 9.5 7.6 7.2 8.8 9.6 12.0 8.9 8.9 9.6 8.2 9.0 10.5 11.5 8.3 9.5 10.5 9.2 10.1 10.7 12.1 9.3 11.1 11.3 10.2 9.5 11.9 12.0 9.5 10.7 10.8 11.2 10.4 12.5 12.1 10.2 11.1 11.7 12.2 12.0 12.9 12.7 10.4 10.8 12.4 13.2 11.4 12.8 12.0 10.6 11.1 12.1 14.2 13.2 13.8 13.5 10.7 11.7 12.7 15.2 12.4 13.6 13.2 11.9 11.0 12.6 16.2 12.3 12.6 12.7 11.7 11.5 12.8 17.2 13.6 13.4 14.6 11.5 12.5 13.4 18.2 12.5 13.5 13.4 11.9 11.9 13.8 19.2 13.7 14.5 13.0 11.8 12.7 14.0 20.2 14.2 12.9 13.5 11.9 13.0 13.6 21.2 13.9 13.0 12.7 12.7 13.4 13.9 22.2 14.7 13.3 13.7 13.0 14.5 13.5 23.2 14.1 12.5 14.8 13.2 14.6 13.0 29.7 12.4 10.8 13.2 10.5 12.1 12.3 30.7 12.6 10.6 13.2 8.7 10.7 13.8 31.7 13.0 10.5 13.1 9.7 11.5 13.1 32.7 12.8 11.2 12.6 9.5 11.8 13.1 33.7 14.9 10.6 12.5 9.3 11.9 13.4 34.7 15.3 11.6 13.9 10.7 11.6 14.4 35.7 15.0 12.5 12.9 10.8 11.5 13.6 36.7 15.3 13.1 13.6 12.4 12.5 13.3 37.7 15.0 12.0 13.9 12.2 12.6 13.4 38.7 15.2 13.3 13.2 12.2 12.9 13.5 39.7 15.3 14.1 13.2 13.0 12.7 14.0 40.7 14.7 13.9 13.8 13.2 12.3 14.1 41.7 15.3 14.1 13.7 13.2 13.4 14.0 42.7 15.4 14.1 14.0 13.8 13.4 14.1 43.7 14.3 14.7 12.9 14.3 13.6 14.2 50.3 14.0 14.0 13.2 12.5 12.1 11.7 51.3 13.2 13.5 14.5 13.4 11.9 13.4 52.3 13.8 13.7 14.5 14.4 12.3 13.0 53.3 14.3 13.6 13.9 13.9 12.9 13.7 54.3 14.5 14.1 14.3 15.3 13.4 13.3 55.3 14.9 14.3 15.0 14.7 12.7 14.1 56.3 16.1 14.2 14.7 14.3 12.3 15.1 57.3 16.2 15.9 14.6 15.2 12.5 17.2 58.3 15.5 15.2 14.3 16.6 12.5 15.5 59.3 15.3 14.4 14.8 16.7 13.0 15.4 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0.0 Oxide Thickness (microns)
60.3 14.8 15.3 14.3 15.5 12.6 15.1 61.3 13.8 15.1 14.3 16.3 13.1 14.9 62.3 15.0 14.4 15.1 16.1 12.9 15.6 63.3 15.3 14.6 14.2 14.7 12.2 14.9 64.3 15.1 15.0 15.0 15.1 12.7 14.5 70.8 14.2 14.6 12.4 12.5 11.7 12.1 71.8 15.2 15.2 14.0 12.4 12.3 14.0 72.8 12.9 14.1 12.7 13.0 12.4 13.8 73.8 14.3 14.3 12.2 12.9 13.1 13.6 74.8 15.1 17.3 11.9 12.8 13.9 13.8 75.8 15.3 17.1 13.6 14.3 13.9 14.2 76.8 16.5 17.2 13.7 14.2 15.3 14.3 77.8 17.2 17.3 14.6 13.6 15.2 14.3 78.8 17.3 17.4 16.0 13.7 15.9 14.2 79.8 15.9 17.3 15.3 13.9 15.7 15.6 80.8 15.5 16.3 15.8 14.2 16.3 14.5 81.8 14.7 17.1 16.0 14.7 16.7 14.9 82.8 14.4 17.1 15.9 14.6 16.7 14.9 83.8 14.7 16.8 16.4 15.5 15.9 14.5 84.8 14.7 17.4 17.4 15.9 16.9 15.5 91.4 13.8 14.1 14.8 12.2 14.7 14.6 92.4 15.6 14.9 15.0 11.0 13.9 14.3 93.4 16.2 15.2 15.5 12.6 14.3 15.5 94.4 16.0 14.7 15.0 11.3 14.6 15.1 95.4 16.6 15.3 15.1 12.2 15.4 16.1 96.4 17.5 15.6 15.7 12.1 16.3 16.5 97.4 17.4 15.9 16.1 12.3 16.1 16.8 98.4 16.8 15.9 17.0 13.5 16.9 17.6 99.4 17.8 15.2 16.4 13.6 16.7 16.0 100.4 17.3 16.0 16.8 14.4 16.9 15.8 101.4 17.9 16.4 16.5 15.0 17.7 15.8 102.4 17.5 15.5 16.9 15.2 18.2 14.9 103.4 17.3 16.6 16.8 16.0 18.8 14.6 104.4 17.3 16.7 16.5 16.6 18.3 14.7 105.4 16.4 15.9 16.1 15.9 17.6 14.6 111.9 13.2 14.5 15.8 14.6 15.0 14.9 112.9 13.3 14.7 15.2 14.9 15.6 15.2 113.9 12.5 14.1 14.9 15.0 15.3 15.9 114.9 13.2 14.5 15.5 14.4 15.8 17.4 115.9 13.8 14.2 15.5 14.1 15.3 17.9 116.9 14.0 14.5 16.6 15.7 16.2 18.4 117.9 14.5 15.3 17.2 16.1 17.2 19.0 118.9 15.2 15.8 17.2 16.1 16.7 17.7 119.9 15.9 15.5 17.3 16.1 16.9 17.9 120.9 16.6 14.9 17.5 16.3 17.1 18.2 121.9 16.6 15.7 16.6 15.9 17.0 18.5 122.9 16.4 15.4 17.3 15.8 17.8 18.3 123.9 15.3 15.0 16.3 16.4 17.1 17.5
124.9 16.0 15.6 15.8 17.2 16.4 17.6 125.9 16.2 17.6 15.6 17.0 16.6 16.4 132.5 15.8 13.6 14.7 13.7 14.3 12.7 133.5 15.7 13.3 14.3 14.5 13.9 13.4 134.5 15.2 13.2 14.0 13.4 14.2 14.3 135.5 15.4 12.8 13.6 12.9 14.7 13.8 136.5 16.5 13.0 13.4 13.3 13.7 13.7 137.5 15.1 14.1 12.6 13.5 14.0 13.0 138.5 14.4 13.9 12.2 12.7 13.8 13.6 139.5 15.9 12.9 12.5 12.5 12.6 12.5 140.5 12.6 14.5 12.6 12.3 12.0 12.5 141.5 11.3 13.5 11.5 11.9 12.2 12.1 142.5 11.1 12.7 11.8 10.9 12.0 11.3 143.5 11.4 12.1 12.9 11.5 11.5 11.0 144.5 10.9 12.8 13.2 11.6 10.8 11.8 145.5 9.9 12.8 11.2 10.5 9.4 10.3 146.5 9.4 11.6 10.5 10.6 9.7 9.8 max 17.9 17.6 17.5 17.2 18.8 19.0
Peripheral Rod Oxide (Comanche Peak 2, FA JJ23, FACE 3) 0.0 5.0 0.0 5.0 0.0 5.0 0.0 5.0 0.0 5.0 0.0 0.0 20.0 40.0 60.0 80.0 100.0 120.0 Axial Elevation (inch)
FR2 FR6 FR8 FR10 FR12 FR14
ACE 3) 120.0 140.0 160.0 14