Peripheral Oxide Utility:
Comanche Peak 2 Assembly: JJ23 Face:
2 Date:
15-Oct-2003 Elevation R02 R06 R08 R10 R12 R14 6.2 8.8 9.2 10.6 8.9 9.3 7.3 7.2 8.7 9.4 11.0 8.9 9.2 8.9 8.2 8.5 9.5 9.7 7.8 9.3 9.0 9.2 9.8 9.8 10.3 8.7 10.3 9.0 10.2 9.4 11.4 11.0 9.4 9.9 8.8 11.2 10.1 11.3 11.1 9.7 9.9 9.9 12.2 11.3 12.4 12.2 9.7 10.7 11.5 13.2 11.6 12.4 11.1 10.4 11.2 10.5 14.2 12.9 13.6 11.9 10.8 12.3 11.0 15.2 12.5 13.4 11.9 11.7 11.3 11.3 16.2 12.2 12.7 11.8 11.9 11.3 11.4 17.2 13.3 13.8 13.8 12.2 12.0 11.9 18.2 13.3 13.5 13.3 12.9 12.1 12.0 19.2 13.5 14.4 13.1 12.5 12.9 12.3 20.2 13.6 12.7 13.7 12.8 12.7 12.2 21.2 13.3 12.5 13.1 13.5 12.3 12.1 22.2 14.5 12.9 14.0 13.6 14.1 12.3 23.2 14.3 12.2 13.2 14.2 13.7 12.0 29.7 11.4 9.7 11.4 9.5 10.3 11.4 30.7 11.4 9.5 11.3 8.8 9.1 12.0 31.7 11.6 9.5 11.4 9.3 9.9 12.6 32.7 11.3 9.6 11.0 9.1 10.5 12.7 33.7 13.1 9.2 11.3 9.0 10.1 13.0 34.7 13.7 10.2 13.1 9.6 10.0 14.2 35.7 13.7 11.5 12.5 9.6 10.0 13.6 36.7 13.8 11.9 12.9 10.6 10.9 13.4 37.7 13.9 11.5 13.7 10.7 11.1 13.8 38.7 14.4 12.2 13.0 11.1 11.0 13.9 39.7 15.0 13.0 13.6 11.8 11.4 14.2 40.7 14.4 12.6 14.0 11.7 11.7 13.6 41.7 14.4 12.9 13.9 11.9 12.7 13.4 42.7 14.1 12.9 13.8 12.4 12.9 13.9 43.7 13.8 13.6 12.3 12.5 12.8 13.8 50.3 12.3 14.1 10.7 8.4 11.8 9.4 51.3 11.7 13.2 11.9 9.4 11.3 10.8 52.3 13.1 12.6 12.3 9.1 11.7 10.8 53.3 13.1 12.9 11.2 8.8 11.7 11.1 54.3 12.8 12.7 11.6 9.1 12.3 12.2 55.3 12.9 12.6 12.8 8.9 11.6 12.2 56.3 13.4 12.8 11.1 8.7 11.4 12.6 57.3 13.9 13.5 10.8 8.8 11.7 14.1 58.3 13.6 13.2 10.2 9.6 11.5 12.7 59.3 13.7 12.7 10.7 10.0 12.2 12.2 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0.0 Oxide Thickness (microns)
60.3 13.4 13.2 11.2 9.7 11.5 12.2 61.3 13.0 13.6 11.5 10.6 11.2 12.0 62.3 14.2 13.0 12.4 11.0 11.1 11.9 63.3 14.2 13.1 12.3 11.0 10.5 11.7 64.3 14.5 13.4 11.9 11.0 10.0 11.3 70.8 13.2 13.5 15.5 13.5 12.5 14.0 71.8 12.2 13.2 15.7 12.5 12.5 15.2 72.8 11.3 13.2 15.1 13.5 13.0 15.6 73.8 12.1 12.3 14.6 12.6 12.8 14.9 74.8 12.7 14.6 15.0 12.3 13.5 14.3 75.8 13.1 14.9 17.1 13.5 14.1 14.8 76.8 13.5 14.5 16.7 13.4 14.0 14.8 77.8 15.4 15.7 17.6 13.5 15.2 15.3 78.8 15.8 15.1 18.2 13.7 16.2 15.5 79.8 16.0 14.8 17.4 13.8 16.3 16.1 80.8 15.7 14.3 17.6 14.3 17.2 15.9 81.8 15.0 14.7 17.4 14.6 16.3 15.8 82.8 14.9 15.7 16.8 14.9 16.7 16.9 83.8 14.6 14.9 16.7 15.1 15.8 16.1 84.8 13.6 14.6 16.9 15.1 16.3 16.3 91.4 12.8 16.2 14.2 13.9 15.0 15.7 92.4 13.8 16.4 13.7 11.9 15.1 15.3 93.4 14.5 16.9 13.9 13.0 15.7 16.4 94.4 14.4 16.9 14.3 12.4 16.3 16.2 95.4 14.9 18.0 13.9 11.8 16.0 16.7 96.4 16.1 18.7 14.2 12.7 16.7 17.8 97.4 16.0 19.0 14.5 13.1 17.1 18.0 98.4 16.4 18.9 14.8 14.0 16.9 18.6 99.4 17.0 17.6 14.9 14.5 17.1 17.6 100.4 16.2 16.9 14.8 14.8 17.0 16.6 101.4 16.4 18.0 15.1 16.3 17.0 16.4 102.4 15.6 17.3 16.2 16.5 17.4 15.9 103.4 15.6 16.6 16.1 16.3 17.6 14.9 104.4 16.3 18.3 16.1 16.8 17.9 14.7 105.4 15.7 17.4 16.1 16.7 17.6 14.9 111.9 16.5 16.0 15.7 13.5 14.4 14.9 112.9 16.4 16.7 15.8 14.3 14.0 14.5 113.9 17.5 15.7 15.4 14.0 15.1 15.6 114.9 17.5 16.3 15.1 13.2 14.7 15.2 115.9 18.1 17.0 15.6 13.6 14.2 14.7 116.9 18.0 16.9 17.5 14.6 15.5 15.7 117.9 17.4 16.7 17.4 15.1 16.0 16.4 118.9 17.6 18.7 17.9 16.1 16.6 17.7 119.9 17.4 17.6 17.3 15.9 16.3 17.6 120.9 17.8 16.4 17.3 16.0 16.4 17.8 121.9 18.4 17.7 17.3 15.7 16.8 18.3 122.9 17.3 16.7 17.4 15.5 17.6 18.4 123.9 16.7 17.0 16.9 15.9 17.5 18.5 124.9 16.9 17.0 17.1 16.6 16.6 18.2
125.9 16.5 16.5 16.6 15.8 16.6 18.2 132.5 16.4 17.3 17.6 14.8 14.9 14.5 133.5 16.4 17.9 17.1 14.5 14.9 14.7 134.5 16.2 17.8 16.6 13.2 15.8 15.7 135.5 15.6 16.4 15.5 13.3 16.0 15.3 136.5 16.6 17.4 16.0 13.6 15.0 14.1 137.5 14.8 17.8 15.0 12.7 14.6 12.9 138.5 14.0 16.7 14.8 11.7 14.3 13.3 139.5 13.8 15.7 15.3 10.9 13.5 12.6 140.5 12.5 16.3 15.2 11.5 13.2 12.3 141.5 11.4 16.2 14.2 12.0 13.7 11.6 142.5 10.9 14.1 13.7 11.3 13.4 11.1 143.5 11.1 12.8 14.2 11.3 12.6 11.1 144.5 11.2 14.6 14.8 11.5 12.4 11.8 145.5 9.6 12.7 12.2 10.7 11.0 10.3 146.5 9.3 12.5 12.0 10.7 11.4 10.0 max 18.4 19.0 18.2 16.8 17.9 18.6
Peripheral Rod Oxide (Comanche Peak 2, FA JJ23, FACE 2) 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0.0 20.0 40.0 60.0 80.0 100.0 120.0 Axial Elevation (inch)
FR2 FR6 FR8 FR10 FR12 FR14
ACE 2) 120.0 140.0 160.0 14