December 2003 Monthly Operating Report for Donald C Cook Units 1 and 2
ML040290547
Person / Time
Site: Cook  
(DPR-058, DPR-074)
Issue date: 01/14/2004
From: Zwolinski J
Indiana Michigan Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
AEP:NRC:2691-38
Download: ML040290547 (8)


Text

Indiana Michigan Power Company 500 Circle Drive I

Buchanan, Ml 49107 1395 INDIANA MICHIGAN POWER January 14, 2004 AEP:NRC:2691-38 Docket Nos.

50-315 50-316 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Units 1 and 2 MONTHLY OPERATING REPORT Pursuant to the requirements of Donald C. Cook Nuclear Plant Unit 1 and Unit 2 Technical Specification 6.9.1.8, the attached Monthly Operating Report for December 2003 is submitted.

There are no new commitments associated with this submittal.

Should you have any questions, please contact Mr. Brian D. Mann, Acting Manager of Regulatory Affairs, at (269) 697-5806.

r, Design Engineering and Regulatory Affairs JEN/jen Attachment

,

t-- (

5(5101

U. S. Nuclear Regulatory Commission.

AEP:NRC:2691-38 Page 2 c: R. Aben - Department of Consumers and Industry Services ANI Nuclear Engineering Department L. Brandon - MDEQ-WHMD/HWRPS M. J. Finissi G. T. Gaffney - ~Canton J. B. Giessner l

INPO Records Center J. N. Jensen B. Lewis - McGraw-Hill Companies D. H. Malin B. D. Mann K. L. Matheny M. K. Nazar NRC Project Manager - NRR NRC Region m !

NRC Resident Inspector D. W. Paul - Columbus T.C.Pham W. H. Schalk J. A. Zwolinski

N.R.C. OPERATING DATA REPORT DOCKET NO.

50-315 DATE 1/1312004 COMPLETED BY T. Pham TELEPHONE 269-465-5901 OPERATING STATUS

1. Unit Name D. C. Cook Unit I Notes:
2. Reporting Period I

Dec-03

3. Licensed Thermal Power (MWt) 3304
4. Name Plate Rating (Gross MWe) 1152
5. Design Electrical Rating (Net MWe) 1020
6. Maximum Dependable Capacity(GROSS MWe) 1056
7. Maximum Dependable Capacity (Net MWe) 1000
8. If Changes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If Any (Net MWe)
10. Reasons For Restrictions.

This Mo.

11. Hours in Reporting Period 744.0
12. No. of Hrs. Reactor Was Critical 744.0
13. Reactor Reserve Shutdown Hours 0.0
14. Hours Generator on Line 744.0
15. Unit Reserve Shutdown Hours 0.0
16. Gross Therm. Energy Gen. (MWH) 2445456.9
17. Gross Elect. Energy Gen. (MWH) 797050.0
18. Net Elect. Energy Gen. (MWH) 770607.0
19. Unit Service Factor 100.0
20. Unit Availability Factor 100.0
21. Unit Capacity Factor (MDC Net) 103.6
22. Unit Capacity Factor (DER Net) 101.5
23. Unit Forced Outage Rate 0.0
24. Shutdowns Scheduled over Next Six Months (Type,Date,and Duration):

Yr. to Date 8760.0 6552.7 0.0 6490.7 0.0 21099452.9 6799373.0 6570087.4 74.1 74.1 75.0 73.5 16.8 Cumm.

254208.0 173901.3 463.0 171179.6 321.0 511368527.5 166041803.0 159845283.9 67.8 67.8 64.3 63.0 19.1

25. If Shut Down At End of Report Period, Est'd Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

UNIT DATE COMPLETED BY TELEPHONE 50-315 ONE 13-Jan-04 T. Pham 269-465-5901 MONTH Dec-03 AVERAGE DAILY POWER LEVEL AVERAGE DAILY POWER LEVEL DAY DAY 12/1/2003 12/2/2003 12/3/2003 12/4/2003 12/5/2003 12/6/2003 12/7/2003 12/8/2003 12/9/2003 12/10/2003 12/11/2003 12/12/2003 12/13/2003 12/14/2003 12/15/2003 12/16/2003 923 1038 1046 1041 1033 1042 1041 1043 1037 1043 1047 1033 1043 1041 1036 1038 12/17/2003 12/18/2003 12/19/2003 12/20/2003 12/21/2003 12/22/2003 12/23/2003 12/24/2003 12/25/2003 12/26/2003 12/27/2003 12/28/2003 12/29/2003 12/30/2003 12/31/2003 1039 1041 1041 1041 1043 1045 1036 1042 1047 1038 1013 1039 1042 1041 1038

DOCKET NO.

UNIT NAME DATE COMPLETED BY TELEPHONE PAGE 50-315 D.C. Cook Unit I January 7, 2004 J. Newmiller 269-465-5901 1 of I UNIT SHUTDOWNS AND POWER REDUCTIONS - December 2003 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO.

DATE TYPE1 HOURS REASON 2 REACTOR3 REPORT NO.

CODE 4 CODE5 TO PREVENT RECURRENCE None 1 TYPE:

F: Forced S: Scheduled 2 REASON:

A: Equipment Failure (Explain)

B: Maintenance or Test C: Refueling D: Regulatory Restriction E: Operator Training and License Examination F: Administrative G: Operational Error (Explain)

H: Other (Explain) 3 METHOD:

1: Manual 2: Manual Scram 3: Automatic Scram 4: Other (Explain) 4 SYSTEM:

Exhibit G - Instructions for preparation of data entry sheets for Licensee Event Report (LER) File (NUREG 0161) 5 COMPONENT:

Exhibit l: Same Source

N.R.C. OPERATING DATA REPORT DOCKET NO.

50-316 DATE 1/13/2004 COMPLETED BY T. Pham TELEPHONE 269-465-5901 OPERATING STATUS

1. Unit Name D. C. Cook Unit 2 Notes:
2. Reporting Period Dec-03
3. Licensed Thermal Power (MWQ) 3468
4. Name Plate Rating (Gross MWe) 1133
5. Design Electrical Rating (Net MWe) 1090
6. Maximum Dependable Capacity(GROSS MWe) 1100
7. Maximum Dependable Capacity (Net MWe) 1060
8. If Changes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If Any (Net MWe)
10. Reasons For Restrictions.

This Mo.

Yr. to Date Cumm.

1 1. Hours in Reporting Period 744.0 8760.0 228354.0

12. No. of Hrs. Reactor Was Critical 709.5 6715.2 148283.3
13. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
14. Hours Generator on Line 683.5 6613.7 144354.2
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Therm. Energy Gen. (MWH) 2336563.6 22452162.2 453675859.5
17. Gross Elect. Energy Gen. (MWH) 769660.0 7340330.0 147114030.0
18. Net Elect. Energy Gen. (MWH) 746195.6 7112167.3 141864906.7
19. Unit Service Factor 91.9 75.5 63.9
20. Unit Availability Factor 91.9 75.5 63.9
21. Unit Capacity Factor (MDC Net) 94.6 76.6 59.7
22. Unit Capacity Factor (DER Net) 92.0 74.5 58.1
23. Unit Forced Outage Rate 8.1 13.4 23.4
24. Shutdowns Scheduled over Next Six Months (Type,Date,and Duration):
25. If Shut Down At End of Report Period, Est'd Date of Startup:

Unit was paralleled to the grid on 114104.

26. Units In Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

UNIT DATE COMPLETED BY TELEPHONE 50-316 TWO 13-Jan-04 T. Pham 269-465-5901 MONTH Dec-03 AVERAGE DAILY POWER LEVEL AVERAGE DAILY POWER LEVEL DAY 12/1/2003 12/2/2003 12/3/2003 12/4/2003 12/5/2003 12/6/2003 12/7/2003 12/8/2003 12/9/2003 12/10/2003 12/11/2003 12/12/2003 12/13/2003 12/14/2003 12/15/2003 12/1 6/2003 DAY 1117 1119 1109 1127 1110 1119 1118 1116 1119 1119 1120 1121 1113 631 6

748 12/17/2003 12/18/2003 12/19/2003 12/20/2003 12/21/2003 12/22/2003 12/23/2003 12/24/2003 12/25/2003 12/26/2003 12/27/2003 12/28/2003 12/29/2003 12/30/2003 12/31/2003 1117 1121 1123 1116 1122 1126 1112 1125 1114 1119 1118 1121 1120 627 0

DOCKET NO.

UNIT NAME DATE COMPLETED BY TELEPHONE PAGE 50 -316 D.C. Cook Unit 2 January 7, 2004 J. Newmiller 269-465-5901 1 of 1 UNIT SHUTDOWNS AND POWER REDUCTIONS - December 2003 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO.

DATE TYPE' HOURS REASON 2 REACTOR3 REPORT NO.

CODE4 CODE5 TO PREVENT RECURRENCE 215 031214 F

26.0 B

4 N/A SJ FCV Power reduction to Mode 2 due to repair of the feedwater reg valve 2-FRV-240 positioner.

216 031230 F

34.5 H

3 316/2003-005 EF BU Unit 2 Reactor automatically tripped from 100% power due to a low steam generator level coincident with feed flow less than steam flow, which occurred during maintenance activities.

1 TYPE:

F: Forced S: Scheduled 2 REASON:

A: Equipment Failure (Explain)

B: Maintenance or Test C: Refueling D: Regulatory Restriction E: Operator Training and License Examination F: Administrative G: Operational Error (Explain)

H: Other (Explain) 3 METHOD:

1: Manual 2: Manual Scram 3: Automatic Scram 4: Other (Explain) 4 SYSTEM:

Exhibit G - Instructions for preparation of data entry sheets for Licensee Event Report (LER) File (NUREG 0161) 5 COMPONENT:

Exhibit l: Same Source