DCM 1.5-1 Rev. 3 TECHNICAL REPORT TITLE PAGE Evaluation of the Dose Integration Parameter in RESRAD-BUILD Title YA-REPT00010-03 Technical Report Number AOPY I

Approvals (Print & Sian Name)

Preparer Cynthia Hamniton Date:

Preparer Estella Keefer I Lt t Date: //6/03 Reviewer Date:

Reviewer:

Date:

Approver (Cognizant Manager):

Date: (111/6 DCM FORM 1.5-1 C Page I of i

DCM 1.5-1 Rev. 3 TECHNICAL REPORTTITLE PAGE Evaluation of the Dose Integration Parameter in RESRAD-BUILD Title

-YA-REPT-OM-tOI3 Technical-Report Number-

.ADDrovals (Print & Sian Name)

Preparer. Cynthia Harrington 11 C

Z

- Date: !-Z\\o Preparer: Estella Keefer (J

Date:

Reviewer:

Date:

Reviewer:

Date:

Approver (Cognizant Manager):

Date:

DCM FORM 1.5-1 C Page 1 of 1

TECHNICAL REPORT TITLE PAGE Evaluation of the Dose Integration Parameter in RESRAD-BUILD Title YA-REPT-00-01 0-03 Technical Report Number Approvals (Print & Sign Name)

Preparer Cynthia Harrinaton Date:

Preparer Estella Keefer Date:

Reviewer J oe ssoc A" &

i*

Date:

z-1-7-o3 Reviewer Date:

Approver (Cognizant Manager):

Date:

DCM FORM 1.5-IC Page 1

Project: Yankee Rowe License Termination Technical Report No. YA-REPT-00-010-03

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Page 2 of 13 Table of Contents Paae Executive Summary............

3 Introd uction..........................................................................................................................................

3 Discussion..........................................................................................................................................3 Results.

4 R efe rences........................................................................................................................................ 4 Tables Paae No Table I - Evaluation of Maximum Number of Time Integration Points.......................................

4......4 Table 2 - Build Sensitivity Analysis vs. the Number of Dose Integrations.........................................

4 Case 1: Fe-55 at Time Integration Points = 1,3, 5, 17....................................................

4 Case 2: Pu-241at Time Integration Points = 3, 5, 9, 17....................................................

4 Appendices No of Pages Appendix I - RESRAD-BUILD Input and Help Screens........................................

4

Project: Yankee Rowe License Termination Technical Report No. YA-REPT-00-010-03

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Page 3 of 13 Executive Summary In order to improve run times for the RESRAD-BUILD v3.21 computer runs, an evaluation was performed on the Dose Integration parameter to support the use of a lower value than the default value of 17. Runs performed at different dose integration values show that a decrease to 5 integrations will not change the results of the sensitivity analysis or dose.

Introduction The dose computed by the RESRAD-BUILD code is obtained by integrating the dose rate over the exposure period. The maximum number of integrations can be specified by the user with the default value set by the code at 17. This report documents a study that demonstrates using a lower number of dose integrations produces the same sensitivity analysis results and dose as that obtained at the default setting.

Discussion Prior to the performance of the sensitivity analysis for the Building Occupancy Scenario using RESRAD-BUILD, the evaluation time' parameter was tested for each nuclide of interest at the YR site j1] to determine the year in which the maximum dose occurs. Based on the guidance in the RESRAD Users Manual [2] and from the help feature of the RESRAD-BUILD code 13], up to nine evaluation times can be specified. The initial runs of this study used 5 Evaluation Times and 17 Dose Integrations. This combination of input specifications resulted in run times for the transuranic nuclides that approached or exceeded a day (and exceeded 9 days for Pu241). The code also displayed run problems that resulted in the termination of program execution. Discussions regarding the problems were held with RESRAD software-support personnel at Argonne National Laboratory (ANL). The discussions led to several steps that allowed the code to run to completion and that educed the run times for the sensitivity analysis and subsequent DCGL and Area Factor runs.

The first step involved the use of an updated version of a RESRAD-BUILD executable file, resbvb.exe, made available by ANL. The new file solved problems encountered as a result of the PC platform in use, Window XP, and allowed a smooth interface between the part of the code performing the computations and the windows interface modules. The need to use the updated executable file appears to be limited to the scenario that uses multiple evaluation times because the code runs successfully when one additional evaluation time is used. Consequently, only one additional evaluation time besides time = 0, which is always evaluated, was specified in these runs and the maximum number of time integrations was reduced from the default value.

According to Reference 1, the Time Integration parameter is the maximum number of integration points the code will use to compute the total dose over the exposure duration. In the integration of the dose rate, the difference in the dose based on I and 2 integration points is evaluated. If the change is greater that 1%, an additional integration based on 3 points is used. If the change in dose based on the 3-point integration is less than 1%, the integration process stops. If it exceeds 1%, then further integrations are performed until the user-specified maximum is reached.

The code does not provide an output of the actual number of integrations used in the calculation of a reported dose. Because the Pu-241 run times were the most excessive, a set of test runs were performed for Pu-241 at different values of the Time Integration-Maximum Number of Points for-Dose' parameter. The purpose of the runs was to evaluate and consequently improve the Pu-241 run time and to confirm that the dose and sensitivity analysis results remained the same. One other nuclide, Fe-55, was evaluated to compare the consistency of the changes. Fe-55 was

Project: Yankee Rowe License Termination

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Technical Report No. YA-REPT-00-010-03 Page 4of13 evaluated at Time Integrations values of 1, 3, 5, and 17. Pu-241 was evaluated at 3, 5 9, and 17 Time Integrations. Note that the Pu-241 evaluations at 3 and 9 Time Integrations also included multiple evaluation times, as indicated in the footnotes of Table 1. This accounts for the longer runs times experienced for these evaluations versus the 5 Time Integration run for Pu-241. The common evaluation times for Pu-241 were T= 0 and T=10 years.

Appendix 1 shows the RESRAD-BUILD code screens referred to in this report and the HELP Screen information that is also available in Reference 3. The information in Appendix 1 is provided to aid and direct the user to the portion of the code this report pertains to.

Results For all runs, the dose and the Partial Rank Correlation Coefficient (PRCC) of the sensitivity analysis were evaluated. The results in Tables 1 and 2 shows that for Time Integrations equal to three and above, the dose and the sensitivity analysis results are unchanged. The difference from the result at I time integration is due to the different approach used, that is, the instantaneous dose at the User-specified-time is calculated. A value of 5 for the Maximum Number of Time Integrations for Dose was chosen to yield a shorter time to completion and not change the results from those obtained with a default value of 17.

Table 1 presents the results of the runs performed at different-Maximum Number of Time Integrations. The run completion time is also evaluated for each Pu-241 case since this is the metric that must be improved.

Table I - Evaluation of Maximum Number of Time Integration Points Nuclide CoRpletion Number of Number of Number of Evaluation Activity Probabilistic Time (hrs)

Integrations Observations Repetitions Times pCi/r 7

Mean Dose Fe-55 0.05 1

300 3

0 3.63E+08 2.86E+01 Fe-55 0.22 3

300 3

0 3.63E+08 2.50E+01 Fe-55 0.37 5

300 3

0 3.63E+08 2.50E+01 Fe-55 0.2 17 300 3

0 3.63E+08 2.50E+01 Pu-241a 27 3

300 3

0 1

9.50E-06 10 1

1.02E-05 Pu-241 16.5 5

300 3

0 1

9.50E-06 10 1

1.02E-05 Pu-241 b 30.5 9

300 3

0 1

9.50E-06 10 1.02E-05 Pu-241 216 17 300 3

0 1

9.50E-06 10 1

1.02E -05 Pu-241 c 58 17 300 3

0 1

9.50E-06 10 1

1.02E-05 a This run also evaluated the dose at T= 4, 6, 8, and 12 years.

bThis run also evaluated the dose at T= 9, 11, 12, and 13 years.

i

Project: Yankee Rowe License Termination

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Technical Report No. YA-REPT-00-010-03 Page 5of13 C This run was made to confirm the results of the 216 hr run because of the excessive time it took for completion (9 days).

Sensitivity Analysis results were also compared for the runs performed at different Time Integration values. Table 2 shows the results of the sensitivity analysis for the same runs summarized in Table 1.

Table 2 - Build Sensitivity Analysis vs. the Number of Dose Integrations (All values correspond to the third repetition)

Case 1: Fe-55 at Time Intearation Points = 1.3, 5, 17

1. Fe-55: Time Integration Points = 1 Coefficients for Total Coefficient Repetition at Time:

1 PCC 3

SRC 3

PRCC 3

SRRC 3

Description of Probabilistic Variable Deposition Velocity Resuspension Rate Release time of 1

Release time of 2 Release time of 3 Release time of 4 Release time of 5

R-SQUARE Sig Coeff Big Coeff Sig Coeff Big Coeff 6 -0.05 6 -0.06 6 -0.15 6 -0.05 7

0.00 7

0.00 7

0.15 7

0.05 4 -0.07 3 -0.14 0.51 1 -0.24

,2 -0.08 2 -0.16 5 -0.43 5 -0.19 5 -0.05 5 -0.11 3 -0.45 3 -0.21 1 -0.08 1 -0.16 2 -0.47 2 -0.21 3 -0.07 4 -0.14 4 -0.44 4 -0.20 0.45 0.45 0.98 0.98

2. Fe-55: Time Integration Points = 3 Coefficients for Total Coefficient Repetition at Time:

1 PCC 3

SRC PRCC SRRC 3

3 3

Description of Probabilistic Variable Deposition Velocity Resuspension Rate Release time of 1 Release time of 2 Release time of 3 Release time of 4 Release time of 5

R-SQUARE Sig Coeff Sig Coeff 6

0.04 6

0.05 7

0.01 7

0.01 4

0.06 4

0.12 1

0.08 2

0.17 5

0.05 5

0.11 2

0.08 1

0.17 3

0.07 3

0.14 Sig Coeff Sig Coeff 7 -0.09 7 -0.02 6

0.13 6

0.02 2

0.70 4

0.20 5 0.68 5

0.20 4

0.68 2

0.21 1

0.74 1

0.23 3

0.69 3

0.21 0.45 0.45 0.99 0.99

3. Fe-55: Time Integration Points = 5 Coefficients for Total at Time:

1 Coefficient Repetition PCC 3

SRC PRCC 3

3 SRRC 3

Description of Probabilistic Variable Deposition Velocity Resuspension Rate Release time of 1 Release time of 2 Release time of 3 Release time of 4 Sig Coeff Sig Coeff ig Coeff Sig Coeff 6

0.04 6

0.05 7 -0.09 7 -0.02 7

0.01 7

0.01 6

0.13

.6 0.02 4

0.06 4

0.12 2

0.70 4

0.20 1

0.08 2

0.17 5

0.68 5

0.20 5

0.05 5

0.11 4

0.68 2

0.21 2

0.08 1

0.17 1

0.74 1

0.23

Project: Yankee Rowe License Termination

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Technical Report No. YA-REPTO-010-03 Page 6 of 13 Release time of 5 3

0.07 3

0.14 3

0.69 3

0.21 0.45 0.45 0.99 0.99 R-SQUARE

-Rank is set to zero if the dose is zero or-the correlation matrix is singular.

-R-SQUARE varies between 0 and 1 and is called the.coefficient of determination; it provides a measure of the variation in the dependent variable (Dose) explained by regression on the independent variables.

4. Fe-55: Time Integration Points = 17 Coefficients for Total Coefficient =

Repetition -

at Time:

1 PCC 3

SRC 3

PRCC 3

SRRC 3

Description of Probabilistic Variable Deposition Velocity Resuspension Rate Release time of 1

Release time of 2

kelease time of 3 Release time of 4

Release time of 5

R-SQUARE Sig Coeff Sig Coeff Sig Coeff Sig Coeff 6

0.04 6

0.05 7

0.01 7

0.01 4

0.06 4

0.12 2

0.08 2

0.17 5

0.05 5

0.1 2

0.08 1 0.17 3

0.07 3

0.14 7 -0.09 7 -0.02 6

0.13 6

0.02 2

0.70 4

0.20 5

0.68 5

0.20 4

0.68 2

0.21 1

0.74 1

0.23 3

0.69 3

0.21 0.45 0.45 0.99 0.99 Case 2: Pu-24lTime Integration Points = 3, 5, 9,17 and Evaluation Time = 0 yr and 10 yr

1. Pu-241: 3 dose integrations T=O Coefficients for Total at Time:

1 Coefficient PCC SRC PRCC SRRC Repetition

=

3 3

3 3

Description of Probabilistic Variable Sig Coeff Big Coeff Sig Coeff Sig Coeff Deposition Velocity Resuspension Rate Release time of 1

Release time of 2 Release time of 3 Release time of 4

Release time of 5

6 -0.04 6 -0.05 6 -0.14 6 -0.02 7 -0.01 7 -0.01 7

0.12 7

0.01 3 -0.07 3 -0.15 1 -0.98 1 -0.26 1 -0.08 1 -0.16 3 -0.81 4 -0.19 5 -0.05 5 -0.10 5 70.79 5 -0.19 2 -0.08 2 -0.15 2 -0.82 2 -0.20 4 -0.07 4 -0.14 4 -0.81 3 -0.20 0.45 0.45 1.00 1.00 R-SQUARE

2. Pu-241: 5 dose integrations T=O Coefficients for Total Coefficient Repetition -

at Time:

1 PCC 3

$RC PRCC 3

3 SRRC 3

Description of Probabilistic Variable Deposition Velocity Resuspension Rate Release time of 1

Release time of 2

Release time of 3

Release time of 4 Release time of 5 sig Coeff Big Coeff Sig Coeff Sig Coeff 6 -0.04 6 -0.05 6 -0.14 6 -0.02 7 -0.01 7 -0.01 7

0.12 7 -0.01 3 -0.07 3 -0.15 1 -0.88 1 -0.26 1 -0.08 1 -0.16 3 -0.81 4 -0.19 5 -0.05 5 -0.10 5 -0.79 5 -0.19 2 -0.08 2 -0.15 2 -0.82 2 -0.20 4 -0.07 4 -0.14 4 -0.81 3 -0.20 4

Project: Yankee Rowe License Termination

Subject:

Evaluation of Dose Integration Parameter In RESRAD-BUILD Technical Report No. YA-REPT-00-01O-03 Page 7 of 13 R-SQUARE 0.45 0.45 1.00 1.00

3. Pu-241: 9 dose integrations T=O Coefficients for Total Coefficient Repetition

=

at Time:

1 PCC 3

SRC 3

PRCC 3

.SRRC 3

Description of Probabilistic Variable Deposition Velocity Resuspension Rate Release time of 1

Release time of 2

Release time of 3 Release time of 4

Release time of 5

SigCoeff Big Coeff ig Coeff Sig CCoeff 6 -0.04 6 -0.05 6 -0.14 6 -0.02 7 -0.01 7 -0.01 7

0.12 7

0.01 3 -0.07 3 -0.15 1 -0.88 1 -0.26 1 -0.08 1 -0.16 3 -0.81 0.19 5 -0.05 5 -0.10 5 -0.79 5 -0.19 2 -0.08 2 -0.15 2 -0.82 2 -0.20 4 -0.07 4 -0.14 4 -0.81 3 -0.20 0.45 0.45 1.00 1.00 R-SQUARE

4. Pu-241: 17 dose integrations T=0 Coefficients for Total Coefficient Repetition at Time:

1 PCC 3

SRC PRCC 3

3 SRRC

.3

-Description of Probabilistic Variable Deposition Velocity Resuspension Rate Release time of 1

Release time of 2

Release time of 3

Release time of 4

Release time of 5

Sig Coeff Sig Coeff Sig Coeff ig Coeff

  • 6 -0.04 6 -0.05 6 -0.14 6 -0.02 7 -0.01 7 -0.01 7

0.12 7

0.01 3 -0.07 3 -0.15 1 -0.88 1 -0.26 1 -0.08 1 -0.16 3 -0.81 4 -0.19 5 -0.05 5 -0.10 5 -0.79 5 -0.19 2 -0.08 2 -0.15 2 -0.82 2 -0.20 4 -0.07 4 -0.14 4 -0.81 3 -0.20 R-SQUARE 0.45 0.45 1.00 1.00

5. Pu-241: 3 dose integrations T=10 years Coefficients for Total Coefficient Repetition at Time:

5 PCC 3

SRC PRCC SRRC 3

3 3

Description of Probabilistic Variable Deposition Velocity Resuspension Rate Release time of 1

Release time of 2

Release time of 3

Release time of 4

Release time of 5.

R-SQUARE Sig Coeff Sig Coeff Sig Coeff Sig Coeff 6

0.05 6

0.06 7 -0.03 7

0.00 7

0.00 7 0.01 6 0.08 6

0.01 4

0.06 4

0.12 5

0.81 5

0.19 1

0.09 1

0.17 2

0.84 2

0.21 5

0.05 5

0.11 4

0.82 4

0.21 2

0.09 2

0.17 1

0.85 1

0.22 3

0.08 3

0.15 3

0.83 3

0.21 0.47 0.47 1.00 1.00

6. Pu-241: 5 dose integrations T=10 years Coefficients for Total Coefficient Repetition at Time:

2 PCC 3

SRC 3

PRCC 3

SRRC 3

Description of Probabilistic Variable Big Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity Resuspension Rate' Release time of 1

Release time of 2

Release time of 3 Release time of i4 Release time of 5 6

0.05 6

0.06 7 -0.03 7

0.00 7

0.01 6

0.08 4

0.06 4 0.12 5 0.81 1

0.09 1

0.17 2

0.84 5

0.05 5

0.11 4

0.82 2 0.09 2 0.17 1 0.85 3 0.08 3 0.15 3 0.83 7

0.00 6

0.01 5

0.19 2

0.21 4

0.21 1 0.22 3

0.21

Project: Yankee Rowe License Termination

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Technical Report No. YA-REPT-00-010-03 Page 8of13 R-SQUARE 0.47 0.47 1 00 1.00

7. Pu-241: 9 dose integrations T=10 years Coefficients for Total Coefficient Repetition

=

at Time:

3 PCC 3

SRC 3

PRCC 3

SRRC 3

Description of Probabilistic Variable Deposition velocity Resuspension Rate Release time of 1 Release time of 2 Release time of 3 Release time of 4 Release time of 5 R-SQUARE SSig Coeff ig Coeff ig Coeff Sig Coeff 6 0.05 6 0.06 7 -0.03 7 '0.00 7 0.01 7 0.01 6 0.08 6 0.01 4 0.06 4 0.12 5 0.81 5 0.19 1 0.09 1 0.17 2 0.84 2 0.21 5 0.05 5 0.11 4 0.82 4 0.21 2 0.09 2 0.17 1 0.85 1 0.22 3 0.08 3 0.15 3 0.83 3 0.21 0.47 0.47 1.00 1.00

8. Pu-241: 17 dose integrations T=10 years Coefficients-for Total Coefficient -

Repetition at Time:

2 PCC SRC PRCC SRRC 3

3 3

3 Sig Coeff igCoeff Description of Probabilistic Variable Sig Coeff Sig Coeff Deposition Velocity Resuspension Rate Release time of 1 Release time of 2 Release time of 3 Release time of 4

Release time of 5

6 0.05 6 0.06 7 -0.03 7 0.00

-7 0.00 7 0.01 6 0.08 6 0.01 4 0.06 4 0.12 5 0.81 5 0.19 1 0.09 1 0.17 2 0.84 2 0.21 5 0.05 5 0.11 4

0.92 4 0.21 2 0.09 2 0.17 1

0.95 1 0.22 3 0.08 3 0.15 3

0.83 3 0.21 R-SQUARE 0.47 0.47 1.00 1.00

9. Pu-241a, 17 dose integrations T-10 years
    • RESRAD-BUILD Regression and Correlation output 3.21B 12/06/03 20:00:49 Page:

30 **

Title

Yankee Rowe Pu-241 17 obs Input File : C:\\Program Files\\REBRADFamily\\BUILD\\Pu-241YR Build 17.BLD Coefficients for Total Coefficient Repetition at Time:

2 PCC

. SRC PRCC 3

3 3

SRRC 3

Description of Probabilistic Variable Deposition Velocity Resuspension Rate Release time of 1 Release time of 2 Release time of 3

Release time of 4 Release time of 5

R-SQUARE Sig Coeff Sig Coeff Big Coeff Sig Coeff 6 0.05 6 0.06 7 -0.03 7

0.00 7 0.00 7 0.01 6 0.08 6 0.01 4 0.06 4 0.12 5 0.S1 5 0.19 1 0.09 1 0.17 2 0.84 2 0.21 5

0.05 5

0.11 4

0.82 4

0.21 2 0.09 2 0.17 1 0.95 1 0.22 3 0.08 3 0.15 3 0.83 3 0.21 0.47 0.47 1.00 1'.00 aThis run was made to confirm the results of the 216 hr run because of the excessive time it took for completion (9 days).

Project: Yankee Rowe License Termination Technical Report No. YA-REPT-00-010-3

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Page 9 of 13 References

1.

YA-REPT-00-001-03, Radionuclide Selection for DCGL Determination, October 2003

2.

ANUEAD/03-1, User's Manual for RESRAD-BUILD Version 3, Yu, C., et al, June 2003

3.

RESRAD-BUILD V3.21 Dose Model Code

Project: Yankee Rowe License Termination

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Calc No. YA-CACL-00-010-03 Page Oof13 Appendix 1 RESRAD-BUILD Input and Help Screens

Project: Yankee Rowe License Termination

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Calc No. YA-CACL-00-010-03 Page 11 of 13 RESRAD-BUILD Evaluation Times Screen showing the default Time Integration value and corresponding Help Screen oK Cace I

Tines fo Calculation breatst 1

10 100 1000 10000 1000 Njnwo l

Add li l

-Time Integration Uaximumn number of points ote Dose ji?

_~~~~~~~~6 TV7 Ad7 77

<x>C I

,,-Numbetr oot 1

',onro Vefoclty D1 jay I

mAuoninR2.W~O ij R26euRcni-cm Ha I."

Sowcetji zi'd-&

.f i,.~~~~~~~~~

M._1i l TlD,!.lVoum,

3 i I >X

<<i.'utln~l Wr7FT': ^ '

X; I EileEit Boaknark Optkxu Flp StIl Jr&

I ack I Hat I

Sk>

I Maximum number of time ntegration h-;

I -

~~points The dose reported at any time is obtained by numerically integrating the 'dose rate over the eposure duration at each receptor location. The user can specify the maxirum number of point to be used for the time Integration. The code will use as many time integration points as is necessary to achieve the preset convergence criteria, subject to the limit specified here.

Related topic Evaluation times

Project: Yankee Rowe License Termination

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Calc No. YA-CACL00-010-03 Page 12 of 13 RESRAD-BUILD Time Integration pull-down menu showing Maximum Number of Points for Dose options (not shown are the values 129 and 257)

F Time Integration Maximum number of points for Dote 17 3

12i1

Project: Yankee Rowe License Termination

Subject:

Evaluation of Dose Integration Parameter in RESRAD-BUILD Calc No. YA-CACL-00-010-03 Page 13of 13 ANUEAD/03-1, Users Manual for RESRAD-BUILD Version 3 J-14 J.1.5 Maximum Time Integration Points Definition: This parameter refers to the maximum number of points used in integrating the dose rate over the exposure duration.

Parameter Name: POINT Units: Unitless Range: 1, 2, 3, 5, 9, 17, 33, 65, 129, 257 Default Value: 17 Window: Time Parameters [ Maximum Time Integration Points Discussion: The dose reported at any evaluation time is obtained by numerically integrating the dose rate over the exposure duration at each receptor location. The user can specify the maximum number of points to be used for the time integration. The code will use as many time integration points as is necessary to achieve the present convergence criteria, subject to the maximum points (limits) specified.

The user can select 1, 2, 3, 5, 9, 17, 33, 65, 129, or 257 as the number of points to calculate the time-integrated dose. If the user selects 1, then the instantaneous dose at the user specified time is calculated. The use of integration points is discussed in Appendix H.

IE