Request for Additional Information - Amendment Application Re. Safety Limit Minimum Critical Power Ratio
ML040220022
Person / Time
Site: Nine Mile Point 
(NPF-069)
Issue date: 01/22/2004
From: Tam P
NRC/NRR/DLPM/LPD1
To: Katz P
Nine Mile Point
Tam P NRR/415-1451
References
TAC MC1370
Download: ML040220022 (3)


Text

January 22, 2004 Mr. Peter E. Katz Vice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093

SUBJECT:

NINE MILE POINT NUCLEAR STATION, UNIT NO. 2 - REQUEST FOR ADDITIONAL INFORMATION - AMENDMENT APPLICATION RE: SAFETY LIMIT MINIMUM CRITICAL POWER RATIO (SLMCPR) FOR FUEL CYCLE 10 (TAC NO. MC1370)

Dear Mr. Katz:

The Nuclear Regulatory Commission (NRC) staff is reviewing the subject proposed amendment, requested by your application dated November 20, 2003. On January 21, 2004, we held a telephone conference with Mr. D. Vandeputte, et al., of your staff, on comments we previously e-mailed to your staff (available in the Agencywide Documents Access and Management System under Accession No. ML04090054). Participants agreed that the first two questions contained in the e-mail were satisfactorily resolved, and that only the third question (next paragraph below) needs a written answer.

Based on Table 1 results in Attachment 4 of the application for amendment, please provide the rationale for an increase of the calculated SLMCPR value for Cycle 10 operation while its product of parameters for the core bundle-by-bundle MCPR distribution and for the bundle pin-by-pin power/R-factor distribution is lower than that for Cycle 9 operation.

Your staff agreed that it can respond by February 13, 2004. If you have any questions, please call me at 301-415-1451.

Sincerely,

/RA/

Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-410 cc: See next page

January 22, 2004 Mr. Peter E. Katz Vice President Nine Mile Point Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093

SUBJECT:

NINE MILE POINT NUCLEAR STATION, UNIT NO. 2 - REQUEST FOR ADDITIONAL INFORMATION - AMENDMENT APPLICATION RE: SAFETY LIMIT MINIMUM CRITICAL POWER RATIO (SLMCPR) FOR FUEL CYCLE 10 (TAC NO. MC1370)

Dear Mr. Katz:

The Nuclear Regulatory Commission (NRC) staff is reviewing the subject proposed amendment, requested by your application dated November 20, 2003. On January 21, 2004, we held a telephone conference with Mr. D. Vandeputte, et al., of your staff, on comments we previously e-mailed to your staff (available in the Agencywide Documents Access and Management System under Accession No. ML04090054). Participants agreed that the first two questions contained in the e-mail were satisfactorily resolved, and that only the third question (next paragraph below) needs a written answer.

Based on Table 1 results in Attachment 4 of the application for amendment, please provide the rationale for an increase of the calculated SLMCPR value for Cycle 10 operation while its product of parameters for the core bundle-by-bundle MCPR distribution and for the bundle pin-by-pin power/R-factor distribution is lower than that for Cycle 9 operation.

Your staff agreed that it can respond by February 13, 2004. If you have any questions, please call me at 301-415-1451.

Sincerely,

/RA/

Peter S. Tam, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-410 cc: See next page DISTRIBUTION:

PUBLIC PDI-1 R/F RLaufer PTam OGC THuang ACRS CBixler, Region I SLittle Accession Number: ML040220022 OFFICE PDI-1/PM PDI-1/LA SRXB SRXB/SC PDI-1/SC NAME PTam SLittle THuang RLandry for FAkstulewicz RLaufer DATE 1/21/04 1/21/04 1/21/04 1/22/04 1/22/04 OFFICIAL RECORD COPY

Nine Mile Point Nuclear Station, Unit No. 2 cc:

Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector Nine Mile Point Nuclear Station P.O. Box 126 Lycoming, NY 13093 Mr. James R. Evans LIPA P.O. Box 129 Lycoming, NY 10393 Supervisor Town of Scriba Route 8, Box 382 Oswego, NY 13126 Mr. Paul D. Eddy Electric Division NYS Department of Public Service Agency Building 3 Empire State Plaza Albany, NY 12223 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 C. Adrienne Rhodes Chairman and Executive Director State Consumer Protection Board 5 Empire State Plaza, Suite 2101 Albany, NY 12223-1556 Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street, NW.

Washington, DC 20005-3502 Mr. Michael J. Wallace President Nine Mile Point Nuclear Station, LLC c/o Constellation Energy Group 750 East Pratt Street Baltimore, MD 21202 James M. Petro, Jr., Esquire Counsel Constellation Energy Group, Inc.

750 East Pratt Street, 5th Floor Baltimore, MD 21202 Mr. Peter R. Smith, Acting President New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399