Technical Specification Page 3.3-51, Primary Containment Isolation Instrumentation
ML040130196
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 01/12/2003
From:
NRC/NRR/DLPM
To:
Bloom S D, NRR/DLPM,415-1313
Shared Package
ML040140264 List:
References
TAC MB6953
Download: ML040130196 (1)


Text

Primary Containment Isolation Inrstrumentation 3.3.6.1 Table 3.3.6.1-1 (page 1 of 4)

Primary Containment Isolation Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER TRIP REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS SYSTEM ACTION C.1 REQUIREMENTS VALUE

1. Main Steam Line Isolation
a. Reactor Vessel Water Level - Low Low Low, Level I 1,2,3 2

D SR 3.3.6.1.1 SR 3.3.6.1.2 SR 3.3.6.1.5 SR 3.3.6.1.6 SR 3.3.6.1.7 2-113 inches

b. Main Steam Line Pressure - Low 1

2 E

SR 3.3.6.1.3 SR 3.3.6.1.6 2 825 psig

c. Main Steam Line Flow - High
d. Condenser Vacuum - Low 1,2,3 1,

2(a), 3(a) 2 per MSL 2

D D

SR 3.3.6.1.1 SR 3.3.6.1.2 SR 3.3.6.1.5 SR 3.3.6.1.6 SR 3.3.6.1.7 SR 3.3.6.1.3 SR 3.3.6.1.6 s 138% rated steam flow 2 7 Inches Hg vacuum

e. Main Steam Tunnel Temperature - High
f. Turbine Building Area Temperature - High 1,2,3 1,2,3 6

16(b)

D D

SR 3.3.6.1.1 SR 3.3.6.1.2 SR 3.3.6.1.5 SR 3.3.6.1.6 SR 3.3.6.1.2 SR 3.3.6.1.5 SR 3.3.6.1.6 5 1940F S 2000F I

2.

Primary Containment Isolation

a. Reactor Vessel Water Level - Low, Level 3
b.

Drywell Pressure -

High 1,2,3 1,2,3 2

2 G

G SR 3.3.6.1.1 SR 3.3.6.1.2 SR 3.3.6.1.5 SR 3.3.6.1.6 SR 3.3.6.1.1 SR 3.3.6.1.2 SR 3.3.6.1.5 SR 3.3.6.1.6 2 0 inches s 1.92 psig (continued)

(a) With any turbine stop valve not closed.

(b) With 8 channels per trip string. Each trip string shall have 2 channels per main steam line, with no more than 40 ft separating any two OPERABLE channels.

HATCH UNIT 2 3.3-51 Amendment No. 181