ML033580397

From kanterella
Jump to navigation Jump to search

Amendment No 198, Tech Spec Pages Dated 12/22/03
ML033580397
Person / Time
Site: Robinson Duke Energy icon.png
Issue date: 12/22/2003
From:
Carolina Power & Light Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML033560622 List:
References
Download: ML033580397 (3)


Text

Fuel Storage Pool Boron Concentration 3.7.13 3.7 PLANT SYSTEMS 3.7.13 Fuel Storage Pool Boron Concentration LCO 3.7.13 APPLICABILITY:

The fuel storage pool boron concentration'shall be

- 1500 ppm.

At all times.

I ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Fuel storage pool

-NOTE- ----

boron concentration LCO 3.0.3 is not applicable.

not within limit.

A.1 Suspend movement of fuel assemblies in Immediately the fuel storage pool.

AND A.2 Initiate action to restore fuel storage pool boron Immediately concentration to within limit.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.13.1 Verify the fuel storage Pool boron concentration is within limit.

7 days HBRSEP Unit No. 2 3.7-31 Amendment No.

19s

Design Features 4.0 4.0 DESIGN FEATURES 4.3 Fuel Storage. (continued)

b. kens c 0.95 in the low density storage racks if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR:
c.

kens s 0.95 in the high density storage racks if fully flooded with water borated to 1500 ppm, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;

d.

kerr less than 1.0 in the high density storage racks if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;

e. A nominal 10.5 inch center-to-center distance between fuel assemblies placed in the high density fuel storage racks;
f.

A nominal 21 inch center-to-center distance between fuel assemblies placed in low density fuel storage racks.

4.3.1.2 The new fuel storage racks are designed and shall be maintained with:

a. Fuel assemblies having a maximum U-235 enrichment of 5.0 weight percent;
b. kerr < 0.95 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR;
c. kerr s 0.98 in an optimum moderation event, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR; and
d.

A nominal 21 inch center to center distance between fuel assemblies placed in the storage racks.

HBRSEP Unit No. 2 4.0-2 Amendment No. 198

Design Features 4.0 4.0 DESIGN FEATURES 4.3.2 Drainage The spent fuel storage pool is designed and shall be maintained to prevent inadvertent draining of the pool below 18 feet above the fuel.

4.3.3 Capacity The spent fuel storage pool is designed and shall be maintained with a storage capacity limited to no more than 544 assemblies.

HBRSEP Unit No. 2 4.0-3 Amendment No. 198