Tech Spec Pages for Amendment 213 Regarding Administrative Controls Section of the Technical Specifications
ML033490585
Person / Time
Site: Palisades Entergy icon.png
Issue date: 12/15/2003
From:
NRC/NRR/DLPM
To:
References
TAC MB8755
Download: ML033490585 (3)


Text

Procedures 5.4 5.0 ADMINISTRATIVE CONTROLS 5.4 Procedures 5.4.1 Written procedures shall be established, implemented, and maintained covering the activities referenced below:

a.

The applicable procedures recommended in Regulatory Guide 1.33, Revision 2, Appendix A, February 1978.

b.

The emergency operating procedures required to implement the requirements of NUREG-0737 and NUREG-0737, Supplement 1, as stated in Generic Letter 82-33;

c.

Site Fire Protection Program implementation.

d.

All programs specified in Specification 5.5.

Palisades Nuclear Plant 5.0-5 Amendment No. 489-, 213

Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.2 Primary Coolant Sources Outside Containment This program provides controls to minimize leakage to the engineered safeguards rooms, from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident, to as low as practical. The systems include the Containment Spray System, the Safety Injection System, the Shutdown Cooling System, and the containment sump suction piping. This program shall include the following:

a.

Provisions establishing preventive maintenance and periodic visual inspection requirements, and

b.

Integrated leak test requirements for each system at a frequency not to exceed refueling cycle intervals.

c.

The portion of the shutdown cooling system that is outside the containment shall be tested either by use in normal operation or hydrostatically tested at 255 psig.

d.

Piping from valves CV-3029 and CV-3030 to the discharge of the safety injection pumps and containment spray pumps shall be hydrostatically tested at no less than 100 psig.

e.

The maximum allowable leakage from the recirculation heat removal systems' components (which include valve stems, flanges and pump seals) shall not exceed 0.2 gallon per minute under the normal hydrostatic head from the SIRW tank.

I 5.5.3 Post Accident Sampling Program

[deleted]

Palisades Nuclear Plant 5.0-7 Amendment No.

9-19, 213

Reporting Requirements 5.6 5.0 ADMINISTRATIVE CONTROLS 5.6 Reporting Requirements The following reports shall be submitted in accordance with 10 CFR 50.4.

5.6.1 Occupational Radiation Exposure Report This report shall include a tabulation on an annual basis of the number of station, utility, and other personnel (including contractors), for whom monitoring was performed, receiving an annual deep dose equivalent greater than 100 mrem and the associated collective deep dose equivalent (reported in person-rem) according to work and job functions (e.g., reactor operations and surveillance, inservice inspection, routine maintenance, special maintenance [describe maintenance], waste processing, and refueling). This tabulation supplements the requirements of 10 CFR 20.2206. The dose assignments to various duty functions may be estimated based on pocket ionization chamber, electronic dosimeter, thermoluminescence dosimeter (TLD), or film badge measurements.

Small exposures totaling less than 20% of the individual total dose need not be accounted for. In the aggregate, at least 80% of the total deep dose equivalent received from external sources should be assigned to specific major work functions. The report covering the previous calendar year shall be submitted by April 30 of each year.

5.6.2 Radiological Environmental Operating Report The Radiological Environmental Operating Report covering the operation of the plant during the previous calendar year shall be submitted before May 15 of each year. The report shall include summaries, interpretations, and analysis of trends of the results of the radiological environmental monitoring program for the reporting period. The material provided shall be consistent with the objectives outlined in the Offsite Dose Calculation Manual and in 10 CFR 50, Appendix I, Sections IV.B.2, IV.B.3, and IV.C.

5.6.3 Radioactive Effluent Release Report The Radioactive Effluent Release Report covering operation of the plant in the previous year shall be submitted prior to May 1 of each year in accordance with 10 CFR 50.36a. The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the plant.

The material provided shall be consistent with the objectives outlined in the Offsite Dose Calculation Manual and Process Control Program, and shall be in conformance with 10 CFR 50.36a and 10 CFR 50, Appendix I, Section IV.B.1.

Palisades Plant 5.0-24 Amendment No. 4, 213 Palisades Plant 5.0-24 Amendment No.

AW, 213