December 1, 2003 Mr. Joseph M. Solymossy Site Vice President Prairie Island Nuclear Generating Plant Nuclear Management Company, LLC 1717 Wakonade Drive East Welch, MN 55089
SUBJECT:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING NRC REVIEW OF PROPOSED CHANGES TO THE EMERGENCY PLAN (REVISION 28) (TAC NO. MC0301 AND MC0302)
Dear Mr. Solymossy:
By letter dated July 23, 2003, the Nuclear Management Company, LLC (NMC), submitted the proposed Revision 28 to the Prairie Island Nuclear Generating Plant Emergency Plan, Annex A, for Nuclear Regulatory Commission (NRC) review and approval. This revision proposes changes to the emergency action levels for seismic events. The NRC staff finds that the additional information identified in the enclosure is needed.
A draft of the request for additional information was e-mailed to Mr. J. Leveille (NMC) on September 30, 2003. A phone call was held between J. Leveille (NMC), M. Agen (NMC),
T. Blount (NRC), and myself on October 7, 2003, to discuss the questions and to gain a mutual understanding. During a phone call on November 24, 2003, a mutually agreeable response date of January 12, 2004, was established.
Please contact me at (301) 415-4106 if future circumstances should require a change in the response date.
Sincerely,
/RA/
Anthony C. McMurtray, Senior Project Manager, Section 1 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-282 and 50-306
Enclosure:
Request for Additional Information cc w/encl: See next page
REQUEST FOR ADDITIONAL INFORMATION REGARDING REVIEW OF THE CHANGES TO THE EMERGENCY PLAN (REVISION 28)
PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNITS 1 AND 2 DOCKET NOS. 50-282 AND 50-306 By letter dated July 23, 2003, the Nuclear Management Company, LLC (NMC), submitted the proposed Revision 28 to the Prairie Island Nuclear Generating Plant Emergency Plan, Annex A, for Nuclear Regulatory Commission (NRC) review and approval. The NRC staff has the following questions related to this submittal:
- 1. Provide a copy of the most recent seismic emergency action levels (EALs) that have received NRC unconditional approval and the corresponding approval documentation.
- 2. Regarding the Seismic Event Annunciator:
a.
Is this located in the control room?
b.
Can the Seismograph alarm panel be read from the control room or is this a remote panel?
c.
If it is a remote panel, how long will it take to have the information provided to the control room decision-maker? Provide minimum and maximum times that are reasonably expected.
d.
Does the control room have immediate indication of the seismograph alarm panel being in an alarm state?
e.
At the seismograph alarm panel, is the annunciator a direct read or does it require any additional information or data retrieval?
- 3. Describe how the following events would be classified:
a.
The operating-basis earthquake annunciator is received on the Seismograph Alarm Panel, the earthquake has caused damage to plant equipment that is needed for safe shutdown and the plant is not in mode 5.
b.
The design-basis earthquake annunciator is received on the Seismograph Alarm Panel, the earthquake has caused damage to plant equipment that is not needed for safe shutdown and the plant is not in mode 5.
- 4. What equipment is considered to be needed for safe shutdown? How is the user provided this information?
- 5. Regarding EALs 19A, 19B, 19C if the earthquake is confirmed by one or more offsite sources, why is it necessary to be confirmed by vibratory ground motion felt by plant personnel and recognized as an earthquake. Doesnt the offsite confirmation satisfy the validation concern? If the ground notion is felt by plant personnel but not recognized as an earthquake, is it accurate to state this EAL will not be declared based on your proposed scheme?
Prairie Island Nuclear Generating Plant, Units 1 and 2 cc:
Jonathan Rogoff, Esquire Vice President, Counsel & Secretary Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Manager, Regulatory Affairs Prairie Island Nuclear Generating Plant Nuclear Management Company, LLC 1717 Wakonade Drive East Welch, MN 55089 Manager - Environmental Protection Division Minnesota Attorney Generals Office 445 Minnesota St., Suite 900 St. Paul, MN 55101-2127 U.S. Nuclear Regulatory Commission Resident Inspector's Office 1719 Wakonade Drive East Welch, MN 55089-9642 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Administrator Goodhue County Courthouse Box 408 Red Wing, MN 55066-0408 Commissioner Minnesota Department of Commerce 121 Seventh Place East Suite 200 St. Paul, MN 55101-2145 Tribal Council Prairie Island Indian Community ATTN: Environmental Department 5636 Sturgeon Lake Road Welch, MN 55089 Nuclear Asset Manager Xcel Energy, Inc.
414 Nicollet Mall, R.S. 8 Minneapolis, MN 55401 John Paul Cowan Executive Vice President & Chief Nuclear Officer Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Craig G. Anderson Senior Vice President, Group Operations Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 November 2003