October 2003 Monthly Operating Report for Nine Mile Point Unit 1
ML033250327
Person / Time
Site: Nine Mile Point 
(DPR-063)
Issue date: 11/13/2003
From: Hopkins L
Constellation Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NMP1L 1800
Download: ML033250327 (4)


Text

P.O. Box 63 Lycoming, New York 13093 Constellation I Nuclear Nine Mile Point Nuclear Station November 13, 2003 NMP1L 1800 A Member of the Constellation Energy Group U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

SUBJECT:

Nine Mile Point Unit 1 Docket No. 50-220 License No. DPR-63 Monthly Operating Report for October 2003 Gentlemen:

Submitted herewith are the Operating Data Report, Unit Shutdowns, and a Narrative of Operating Experience for October 2003 for the Nine Mile Point Nuclear Station Unit 1.

Submittal of this information complies with Section 6.6.4 of the Unit 1 Technical Specifications.

Very truly yours, Lawrence

. Hopkins Plant General Manager LAH/BE/jm Attachments cc:

Mr. H. J. Miller, NRC Regional Administrator, Region I Mr. G. K. Hunegs, NRC Senior Resident Inspector

j:71q,

ATTACHMENT A OPERATING DATA REPORT DOCKET NO: 50-220 DATE: 11/04/03 PREPARED BY: B. L. Eastman TELEPHONE: (315) 349-2559 OPERATING STATUS Unit Name: Nine Mile Point Unit #1 Reporting Period: October 2003 2

2 Design Electrical Rating: (Net MWe)

Maximum Dependable Capacity: (Net MWe) 613 565 3

Critical Hours 4

Hours Generator On-Line 5

Unit Reserve Shutdown Hours 6

Net Electrical Energy Generated (MWH)

This Month 745.0 745.0 0.0 438,806.0 Yr-to-Date 6,080.8 5,911.4 0.0 3,505,073.0 Cumulative 211,367.6 206,773.7 20.4 115,440,454.0

ATTACHMENT B UNIT SHUTDOWNS REPORTING PERIOD - OCTOBER 2003 DOCKET NO: 50-220 UNIT NAME: NMP 1 DATE: 11/04/03 PREPARED BY: B. L. Eastman*

TELEPHONE: (315) 349-2559 TYPE NO.*

DATE F: FORCED DURATION REASONS' METHOD OF SHUTTING CAUSE & CORRECTIVE ACTIONS S: SCHEDULED (HOURS)

DOWN2 COMMENTS No shutdowns occurred in October 2003 (I)

Reason A.

Equipment Failure (Explain)

B.

Maintenance or Test C.

Refueling D.

Regulatory Restriction E.

Operator TrainingfLicense Examination F.

Administrative G.

Operational Error (Explain)

II.

Other (Explain)

  • NOTE: Sequential numbering used.

(2)

Method

1.

Manual

2.

Manual Trip/Scram

3.

Automatic Trip/Scram

4.

Continuation

5.

Other (Explain)

ATTACHMENT C NARRATIVE OF OPERATING EXPERIENCE DOCKET NO: 50-220 UNIT NAME: NMPI DATE: 11/04/03 PREPARED BY: B. L. Eastman TELEPHONE: (315) 349-2559 The unit operated during the month of October 2003 with a Net Electrical Design capacity factor of 96.1 percent.

On October 1, 2003 at 0200 hours0.00231 days <br />0.0556 hours <br />3.306878e-4 weeks <br />7.61e-5 months <br />, power was reduced to remove Reactor Recirculation Pump 12 from service for planned maintenance. This placed the unit in 3-loop operation, thus reactor power was restricted to 90 percent. Reactor Recirculation Pump 12 was returned to service on October 4, 2003 at 2037 hours0.0236 days <br />0.566 hours <br />0.00337 weeks <br />7.750785e-4 months <br /> and the unit was returned to full power at 2316 hours0.0268 days <br />0.643 hours <br />0.00383 weeks <br />8.81238e-4 months <br /> the same day.

On October 25, 2003 at 0805 hours0.00932 days <br />0.224 hours <br />0.00133 weeks <br />3.063025e-4 months <br />, power was reduced to approximately 65 percent to perform a control rod sequence exchange and control rod scram time testing/maintenance for select rods. The scope of the job for control rod scram timing/maintenance was expanded when 4 rods failed their Technical Specification times at 5 percent. On October 26, 2003 at 1431 hours0.0166 days <br />0.398 hours <br />0.00237 weeks <br />5.444955e-4 months <br />, scram time testing/maintenance was completed and power was returned to rated at 0356 hours0.00412 days <br />0.0989 hours <br />5.886243e-4 weeks <br />1.35458e-4 months <br /> on October 27, 2003.