Technical Specification Pages for D. C. Cook, Unit 1, Issuance of Amendment No. 263, Lowering the Trip Setpoint and Allowable Value Contained in TS Table 3.3.4 for the Pressurizer Pressure Low Safety Injection Signal
ML033180463
Person / Time
Site: Cook 
(DPR-074)
Issue date: 11/12/2003
From:
NRC/NRR/DLPM
To:
References
TAC MB8202
Download: ML033180463 (2)


Text

3/4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.3 INSTRUMENTATION ENGINEERED SAFETY FEATURES INTERLOCKS DESIGNATION CONDITION AND SETPOINT FUNCTION P-11 P-12 With 2 of 3 pressurizer pressure channels greater than or equal to 1915 psig.

With 2 of 4 Tag channels less than or equal to Setpoint.

Setpoint greater than or equal to 541 0F.

P-11 prevents or defeats manual block of safety injection actuation on low pressurizer pressure.

P-12 allows manual block of safety injection actuation on low steam line pressure. Causes steam line isolation on high steam flow. Affects steam dump blocks.

With 3 of 4 T,,g channels above the reset point, prevents or defeats the manual block of safety injection actuation on low steam line pressure.

I COOK NUCLEAR PLANT - UNIT 2 Page 3/4 3-22a Amendment No. +37-,--

263

I i.

3/4 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS 3/4.3 INSTRUMENTATION TABLE 3.3-4 ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION TRIP SETPOINTS FUNCTIONAL UNIT TRIP SETPOINTS ALLOWABLE VALUES 1.

SAFETY INJECTION, TURBINE TRIP, FEEDWATER ISOLATION, AND MOTOR DRIVEN AUXILIARY FEEDWATER PUMPS

a.

Manual Initiation


See Functional Unit 9----

b.

Automatic Actuation Not Applicable Not Applicable Logic

c.

Containment Pressure Less than or equal to 1.1 Less than or equal to 1.2 psig High psig

d.

Pressurizer Pressure-Greater than or equal to Greater than or equal to Low 1815 psig 1805 psig

e.

Differential Pressure Less than or equal to 100 Less than or equal to 112 psi Between Steam Lines-psi High

f.

Steam Line Pressure-Greater than or equal to Greater than or equal to 585 Low 600 psig steam line psig steam line pressure pressure COOK NUCLEAR PLANT-UNIT 2 Page 3/4 3-23 Amendment No. 1, 11, 28, 134,137, 263