i. Tho,...,, Alexion - Add'I info from ANO a

4 Tho., ~~~Alexion

- Add'l info from AND

~~~~~Page 1

From:

, Rebecca Nease To:

P-f-'Alexion, Thomas; Bongarra, James; Bywater, Russ; Chamberlain, Dwight; Dixon-Herrity, Jennifer, Eckenrode, Richard; Frumkin, Daniel; Gody, Tony; Gramm, Robert; Gwynn, Pat; Hannon, John; Howell, Art; IQBAL, Naeem; Marschall, Charles; Parry, Gareth; Pruett, Troy; Qualls, Phil; Reinhart, F. Mark; Salley, Mark; Sanborn, Gary; Smith, Karla; Smith, Linda; Tschiltz, Michael; Wong, See-Meng Date:

7/14/03 3:46PM

Subject:

Add'I info from ANO NRC Reg Conf Attendees, Attached is a list of items we requested the licensee provide to us. I intend to include this with the meeting summary. Please review them to make sure I worded the requests as you meant them to be. If you have any questions or comments, you may respond to this e-mail, or call me at 817-860-8154.

.* r1.ra 1o ('if hS record V..,, de~ e I ui'r wthth

,icodoln ot l1tfornifation r U2 ~ ~ I'it tlt F X

ANO REGULATORY CONFERENCE QUESTIONS The following are what, in the regulatory conference, we asked the licensee to provide. Please review and confirm:

  • Thiomas Ale'xio'n" Re: Add'I info from *ANOPae From:

Thomas Alexion To:

Rebecca Nease LV Date:

7/14/03 4:33PM

Subject:

Re: Add'l info from ANO

Rebecca, My comments are as follows:
1. I had an addition subpart for the licensee to address the effect of thermoplastic cables to safely S/D Unit 2.
2. I had additional subparts to also provide the timeline for operator actions, and to provide the raw simulator data and evaluator sheets.
3. I thought the list was supposed to be for all cables in the area.
4. I had an additional subpart to address why the particular coating was chosen.

But I will defer to SPLB on these comments.

Tom

>>> Rebecca Nease 07/14/03 03:46PM>>>>

NRC Reg Conf Attendees, Attached is a list of items we requested the licensee provide to us. I intend to include this with the meeting summary. Please review them to make sure I worded the requests as you meant them to be. If you have any questions or comments, you may respond to this e-mail, or call me at 817-860-8154.

CC:

Mark Salley