November 4, 2003 Mr. J. A. Stall Senior Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420
SUBJECT:
SAINT LUCIE PLANT, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING LICENSE AMENDMENT REQUESTS FOR INCREASING SPENT FUEL STORAGE CAPACITY (TAC NOS. MB6627 AND MB6628)
Dear Mr. Stall:
By letter dated October 23, 2002, Florida Power and Light Company (FPL) submitted a request to revise the St. Lucie, Units 1 and 2, Technical Specifications to include the design of a new cask pit spent fuel storage rack for each unit in order to increase each units spent fuel storage capacity. By letter dated August 28, 2003, FPL provided a response to the U.S. Nuclear Regulatory Commission (NRC) request for additional information (RAI) dated July 22, 2003.
The NRC staff has reviewed your response and finds that additional clarification is needed. A response to the enclosed RAI is needed before we can complete the review. This request was discussed with your staff on October 30, 2003, and Mr. George Madden agreed that a response would be provided by December 12, 2003.
If you have any questions, please feel free to contact me at (301) 415-3974.
Sincerely,
/RA/
Brendan T. Moroney, Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-335 and 50-389
Enclosure:
RAI cc w/encl: See next page
033080014 OFFICE PDII-2/PM PDII-2/LA PDII-2/SC NAME BMoroney BClayton KJabbour for AHowe DATE 10/31/03 11/03/03 11/03/03
REQUEST FOR ADDITIONAL INFORMATION (RAI)
ADDITION OF SPENT FUEL POOL CASK AREA RACK AMENDMENT FLORIDA POWER AND LIGHT SAINT LUCIE PLANT, UNITS 1 AND 2 DOCKET NOS. 50-335 AND 50-389 Section 3.5 "Handling of Heavy Loads" of the October 23, 2002, submittal stated:
Section 3.5 in Enclosure 2 details the defense-in-depth approach taken to ensure that the handling of the racks and platforms by the cask handling cranes will comply with the NUREG-0612 guidance.
However, the discussion in Section 3.5 of Enclosure 2 seems to be limited to the guidance addressed in Section 5.1.1 of NUREG-0612.
Compliance with NUREG-0612, is also addressed in the licensees August 28, 2003, response to the staff RAI; however, the responses to RAI questions 6 and 7 concerning compliance with NUREG-0612 address only Section 5.1.1 of NUREG-0612.
Guidance given in Section 5.1.2 of NUREG-0612 recommends that one of the four criteria listed in Section 5.1.2 of the NUREG also be satisfied. Describe how the Spent Fuel Cask Handling Crane meets the guidelines of Section 5.1.2 of NUREG-0612.
Mr. J. A. Stall ST. LUCIE PLANT Florida Power and Light Company cc:
Senior Resident Inspector St. Lucie Plant U.S. Nuclear Regulatory Commission P.O. Box 6090 Jensen Beach, Florida 34957 Craig Fugate, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 M. S. Ross, Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Douglas Anderson County Administrator St. Lucie County 2300 Virginia Avenue Fort Pierce, Florida 34982 Mr. William A. Passetti, Chief Department of Health Bureau of Radiation Control 2020 Capital Circle, SE, Bin #C21 Tallahassee, Florida 32399-1741 Mr. William Jefferson, Jr.
Site Vice President St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957 Mr. G. L. Johnston Plant General Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957 Mr. Terry Patterson Licensing Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957 Vice President, Nuclear Operations Support Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Rajiv S. Kundalkar Vice President - Nuclear Engineering Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. J. Kammel Radiological Emergency Planning Administrator Department of Public Safety 6000 SE. Tower Drive Stuart, Florida 34997