October 3, 2003 Mr. Roy A. Anderson President & Chief Nuclear Officer PSEG Nuclear, LLC - X04 Post Office Box 236 Hancocks Bridge, NJ 08038

SUBJECT:

SALEM NUCLEAR GENERATING STATION, UNIT NO. 2, RE: FINAL ACCIDENT SEQUENCE PRECURSOR ANALYSIS OF FEBRUARY 2000 OPERATIONAL EVENT

Dear Mr. Anderson:

Enclosed for your information is the final Accident Sequence Precursor (ASP) analysis of an operational event which occurred at the Salem Nuclear Generating Station, Unit No. 2, in February 2000. This condition was documented in NRC Inspection Report 50-311/99-010, dated February 14, 2000. The results of the final ASP analysis indicate that this event is a precursor (i.e., the importance or change in core damage probability (CCDP) >1E-6).

In the past, preliminary versions of all ASP analyses were issued for internal peer review by the U.S. Nuclear Regulatory Commission (NRC) staff and for external peer review by the licensee.

Comments received from these reviews were then resolved as part of the final analysis. To increase efficiency, we are now issuing the non-controversial ASP analyses as final documents. In this event, the findings in the ASP analysis (i.e., the change in CCDP and dominant risk contributors) are consistent with those in the Significance Determination Process (SDP). Since this ASP analysis confirms the results of the final SDP, which has been reviewed by the NRC staff and PSEG Nuclear, it is being issued as a final product for information only.

Due to the potential sensitivity of the information described in the enclosed ASP analysis, the staff has not made this enclosure publicly available.

Please contact me at 301-415-1324, if you have any questions regarding the enclosure.

Sincerely,

/RA/

Robert J. Fretz, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-311

Enclosure:

As stated (Sensitive - Not for Public Disclosure) cc w/o encl: See next page

October 3, 2003 Mr. Roy A. Anderson President & Chief Nuclear Officer PSEG Nuclear, LLC - X04 Post Office Box 236 Hancocks Bridge, NJ 08038

SUBJECT:

SALEM NUCLEAR GENERATING STATION, UNIT NO. 2, RE: FINAL ACCIDENT SEQUENCE PRECURSOR ANALYSIS OF FEBRUARY 2000 OPERATIONAL EVENT

Dear Mr. Anderson:

Enclosed for your information is the final Accident Sequence Precursor (ASP) analysis of an operational event which occurred at the Salem Nuclear Generating Station, Unit No. 2, in February 2000. This condition was documented in NRC Inspection Report 50-311/99-010, dated February 14, 2000. The results of the final ASP analysis indicate that this event is a precursor (i.e., the importance or change in core damage probability (CCDP) >1E-6).

In the past, preliminary versions of all ASP analyses were issued for internal peer review by the U.S. Nuclear Regulatory Commission (NRC) staff and for external peer review by the licensee.

Comments received from these reviews were then resolved as part of the final analysis. To increase efficiency, we are now issuing the non-controversial ASP analyses as final documents. In this event, the findings in the ASP analysis (i.e., the change in CCDP and dominant risk contributors) are consistent with those in the Significance Determination Process (SDP). Since this ASP analysis confirms the results of the final SDP, which has been reviewed by the NRC staff and PSEG Nuclear, it is being issued as a final product for information only.

Due to the potential sensitivity of the information described in the enclosed ASP analysis, the staff has not made this enclosure publicly available.

Please contact me at 301-415-1324, if you have any questions regarding the enclosure.

Sincerely,

/RA/

Robert J. Fretz, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-311

Enclosure:

As stated (Sensitive - Not for Public Disclosure) cc w/o encl: See next page DISTRIBUTION:

Non-Public JClifford MHarper, RESGMeyer, Region I PDI-2 Reading RFretz JGolla, NRR ACRS CRaynor OGC ACCESSION NO. ML032760278 OFFICE PDI-2/PM PDI-2/LA PDI-2/SC NAME RFretz CRaynor JClifford DATE 9/25/03 9/26/03 9/30/03 OFFICIAL RECORD COPY

Salem Nuclear Generating Station, Unit Nos. 1 and 2 cc:

Mr. Timothy J. OConnor Vice President - Operations PSEG Nuclear - X15 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. John T. Carlin Vice President - Engineering PSEG Nuclear - N10 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David F. Garchow Vice President - Projects and Licensing PSEG Nuclear - N28 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. Gabor Salamon Manager - Nuclear Safety and Licensing PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Jeffrie J. Keenan, Esquire PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Ms. R. A. Kankus Joint Owner Affairs PECO Energy Company Nuclear Group Headquarters KSA1-E 200 Exelon Way Kennett Square, PA 19348 Lower Alloways Creek Township c/o Mary O. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 Brian Beam Board of Public Utilities 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector Salem Nuclear Generating Station U.S. Nuclear Regulatory Commission Drawer 0509 Hancocks Bridge, NJ 08038