Entergy Nuclear Northeast Vermont Yankee P.O. Box 0500 185 Old Ferry Road

"'O C t:E n

Brattleboro, VT 05302-0500 Anm"Y Tel 802 257 5271 September 24, 2003 BVY 03-85 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Subject:

Vermont Yankee Nuclear Power Station License No. DPR-28 (Docket No. 50-27 1)

Vermont Yankee Emergency Plan Implementing Procedure Changes In accordance with 10 CFR 50.54(q), enclosed is the latest changes to the Vermont Yankee Emergency Plan Implementing Procedures including the change memos and the 10 CFR 50.54(q) Evaluation Checklists:

OP 3506, Rev. 43, LPC #1 OP 3547, Rev. 2 These changes were determined to not need prior NRC review and approval.

If you have any questions, please contact Audra Williams, Emergency Planning Coordinator, in our Brattleboro office at (802) 258-4177.

Sincerely, ENTERGY NUCLEAR NORTHEAST VERMONT YANKEE Lori Tkaczyk Emergency Planning Manager Attachments cc:

USNRC Region I Administrator USNRC Resident Inspector - VYNPS USNRC Project Manager - VYNPS (no attachments)

David M. Silk, Senior Emergency Preparedness Specialist, USNRC Region 1 Vermont Department of Public Service DO4SS

S U

I U

U S

  • 6 To:

E-Plan Implementing Procedure Controlled Set Holders From: Technical Support - DCC - Marie E. Sherer Date:

09/24/03 Re:

Entergy Vermont Yankee Emergency Plan Implementing Procedure Change 220, Instruction Sheet A new Table of Contents is included.

LPCs:

Proc/Rev #

OP 3506143 REVISIONS:

ProclRev #

OP 3547/2 The following LPC should be incorporated into the appropriate procedures:

LPC#

1 Procedure Title Emergency Equipment Readiness Check The following Revs should replace the appropriate procedures:

Procedure Title Security Actions During An Emergency

I Vermont Yankee Emergency Plan Implementing Procedures I

Table of Contents September 24,2003 Title Number Revision LPC #

Use Classification Emergency Plan Classification and Action Level Scheme AP 3125 Rev. 19 "Reference" Emergency Communications OP 3504 Rev. 36 2

"Reference" Emergency Preparedness Exercises and Drills OP 3505 Rev. 24 2

"Information" Emergency Equipment Readiness Check OP 3506 Rev. 43 1

"Reference" Emnergency Radiation Exposure Control OP 3507 Rev. 30

" Reference" On-Site Medical Emergency Procedure OP 3508 Rev. 23 "Reference" Environmental Sample Collection During an Emergency OP 3509 Rev. 17 "Reference" Off-Site and Site Boundary Monitoring OP 3510 Rev. 27 "Reference" Off-Site Protective Action Recommendations OP 3511 Rev. 12 "Reference" Evaluation of Off-Site Radiological Conditions OP 3513 Rev. 21 "Reference" Emergency Actions to Ensure Initial Accountability and Security OP 3524 Rev. 20 "Reference"

Response

Radiological Coordination OP 3525 Rev. 10 "Reference" Emergency Call-In Method OP 3531 Rev. 16 "Reference" Emergency Preparedness Organization AP 3532 Rev. 11 "Information" Post Accident Sampling of Reactor Coolant OP 3533 Rev. 6 1

"Continuous" Post Accident Sampling of Plant Stack Gaseous Releases OP 3534 Rev. 4 "Continuous" Post Accident Sampling and Analysis of Primary Containment OP 3535 Rev. 4 "Continuous" In Plant Air Sample Analysis with Abnormal Condition OP 3536 Rev. 2 "Continuous" Control Room Actions During an Emergency OP 3540 Rev. 3 "Reference" Activation of the Technical Support Center (TSC)

OP 3541 Rev. 2 "Reference" Operation of the Technical Support Center (TSC)

OP 3542 Rev. 2 "Reference" Activation of the Operations Support Center (OSC)

OP 3543 Rev. 0 "Reference" Operation of the Operations Support Center (OSC)

OP 3544 Rev. 3 "Reference" Activation of the Emergency Operations Facility/Recovery Center OP 3545 Rev. 2 "Reference" (EOF/RC)

Operation of the Emergency Operations Facility/Recovery Center OP 3546 Rev. 3 "Reference" (EOF/RC)

Security Actions During an Emergency OP 3547 Rev. 2 "Reference" Emergency Plan Training OP 3712 Rev. 17 "Information" Page 1 of 1

REVISED PROCEDURE CONTROL FORM PART 1 - Initiation A. Procedure No.

New Revision Title OP 3547 LNo. 2 Securiy Actions During An Emergency B. Review Criteria: E] Partial

[]Editorial I C. Periodic Review Cycle:

3 2 Year (Event Driven)

Complete N/A D. List DIs & LPCs: 1 E. Description and Reasons for Procedure/Changes:

  • Title changes throughout
  • EPEX-2003-SEC_01 - Add notification of event to BREs.

F.

Originator Name:

(App. A was used as references to create this revision, App. C is Telephone completed and attached unless Part 1.B above is 'Editorial".)

Extension:

(Print/sign/date) Audra Williams M87/03 x4177 PART 2 - Reviews A. Walk-Through Validation: [ Required 3

N/A B. Technical Verification Reviewer [1 N/A

- (App. B used as a reference) 1

[];e Fieod Walk-TSrough

.l (Print/SignlDate)

Table-Top aSimulator Validation H

~a^Wcg s

C. Cross-Discipline Reviews:

[]N/A Department Name Signature Date Security

~

far4~

D. 50.59 Review Per AP 6002, Preparing 50.59 Evaluations a N/A 050.59 AD previously performed and documented in the text of this procedure and is still applicable.

D 50.59 Applicability Determination completed and attached; 50.59 Screening NOT required.

El 50.59 Review Screening completed and attached, 50.59 Evaluation NOT required.

El 50.59 Evaluation completed and attached.

E. QUALIFIED REVIEWER: Use App. D as a reference (May perform 50.59 Applicability Determination)

(Part 2.D)

(Print/SignI/Date) AUAI-c Wj9,ftairS

-5W~u-~

gLJZda/~r 6*

-03 F. ORIGINATOR:

Comments Resolved RrRe-verify All _Ds & LPCs Considered

[Sent for Final Type (CDS or STC (SPs only)) Initial/Date DO 1

Proofread after Final Type (PrinuSign/Date)

Atw m WI llamS q wl bL)L1-q9.I 03 VYAPF 0096.01 AP 0096 Rev. 3 Page l of 2

DA I

RT 3 - Training/Notification Requtrements Indicate training or notifications required to implement procedure: (Required for Administrative Procedures)

El Include in formal training (17CR submitted):

I E-Mail notification: E-mail SSS's El Crew Briefings:

El Other.

N/A PART 4-PORC Plant Operation Review Committee: El Required 0 N/A Meeting No:

PORC Secretary:

Date:

Plant Manager:

PART S - Approval A. Responsible Procedure Owner: (Print/Signature/Date)

C&A.,M B. Plant Manager (Print/Sign/Date) (For SPs Onfy)

N/A C. Special Instructions:

N/A El Approved for Training q'24-03 Issue on DATE:

El Submit Surveillance Database Change per AP 4000 El Other:

PART 6 - Issuance Procedure Change No.:

Date procedure issued:

Notes:

VYAPF 0096.01 AP 0096 Rev. 3 Page 2 of 2

10 CFR 50.54(q) Evaluation Checkiist List of Emergency Plan Section(s)/Emeirgency Plan Implementing Procedure(s) or any other document to be evaluated. (Include Title and Revision No.):

OP 3547, Rev. 2, Security Actions During an Emergency A.

Screening Evaluation Based on a review of the following questions, determine if the change has the potential to affect our ability to meet the standards of 10 CFR 50A7(b) and the requirements of Appendix E to 10 CFR 50.

A "YES" answer to any part of the questions requires that a written evaluation be done to determine whether the effectiveness of the Emergency Plan was decreased as specified in Section B of this checklist.

A "NO' answer to all questions requires no written evaluation as specified in Section B of this checklist.

I YES INOI Could the proposed change affect our ability to meet the following standards of I OCFR5O.47(b):

(I)

Assignment of Emergency Response Organization responsibilities (2)

Assignment of on-shift Emergency Response Organization personnel (3)

Arrangements for Emergency Response Support and Resources (4)

Emergency Classification and Action levels, including facility system and effluent parameters (5)

Notification Methods and Procedures (6)

Emergency Communications among principal response organizations and the public (7)

Public Education and Information (8)

Adequacy of Emergency Facilities and Equipment (9)

Adequacy of Accident Assessment methods, systems and equipment (10)

Plume exposure pathway EPZ protective actions (11)

Emergency Worker Radiological Exposure Control (12)

Medical Services for contaminated injured individuals (13)

Recovery and Reentry Plans (14)

Emergency response periodic drills and exercises (15)

Radiological Emergency Response Training (16)

Plan development, review and distribution x

x X

X X

X X

I X

X_<

~X tX~~

X XX X

x x

VYAPF 3532.01 AP 3532 Rev. II Page I of 3

10 CFR 50.54(q) Evaluation Checklist (Continued)

2.

Could the change affect our ability to meet the following requirements of Appendix E to I OCFR50 (1)Section IV. A - Organization (2)

Section IV. B - Assessment Actions (3)

Section IV. C - Activation of Emergency Organizations (4)

Section IV. D - Notification Procedures (5)

Section IV. E - Emergency Facilities and Equipment (6)

Section IV. F - Training (7)

Section TV. G - Maintaining Emergency Preparedness (8)

Section IV. H - Recovery I

YES N

X' X-X X

X X

XI X

B.

Effectiveness Determination For each applicable (i.e., a "yes'" answer specified) standard to 10CFR50.47(b) and Appendix E to IOCFR50 identified from Section A above, complete the evaluation form below to determine whether thie change decreases the effectiveness of the Emergency Plan and whether it continues to meet the stated applicable standard or requirement.

A facsimile of the evaluation form may be used as needed and attached to this checklist.

For applicable item 10CFR50.

NIA of Section A above, this change El DOES 0 DOES NOT decrease the effectiveness of the Emergency Plan and CD DOES E DOES NOT continue to meet the stated applicable standard or requirement.

BASIS FOR ANSWER:

Added notification to BREs of event as a step in procedure as there is no gai-tronics or group announcement/public address system in the BREs to notify Security personnel of event. This will ensure they are aware of events taking place in addition to any radio communications..

VYAPF 3532.01 AP 3532 Rev. 11 Page 2 of 3

10 CFR 50.54(q) Evaluation Checklist (Continued)

C.

Conclusion (Fill out appropriate information)

>3 The changes made do not decrease the effectiveness of the Emergency Plan and continue to meet the standards of IOCFR50.47(b) and the requirements of Appendix E to 1 0CFR50.

I]

The changes made do decrease the effectiveness of the Emergency Plan and decrease our ability to meet the standards of IOCFR50.47(b) and the requirements of Appendix E to IOCFR50. The following course of action is recommended:

D1 Revise proposed changes to meet applicable standards and requirements.

Cancel the proposed changes.

El Process proposed changes for NRC approval prior to implementation in accordance with IOCFR50.54(q).

D.

Impact on Other Documents (IRM, Tech Specs)

Keywords used in search:

>3 This change does not affect any other documents.

  • El This change does affect other documents.

Document(s) affected:

Section(s) affected:

E.

Impact on the Updated FSAR Use AP 6036 to determine if the proposed E-Plan change modifies existing UFSAR information or requires the addition of new UFSAR information and initiate UFSAR change(s) as required.

Keywords used in UFSAR search:___

Additional Comments:

Prepared By: Audra Williams ptuam I) I Atn Date: 8/7/03 (Print/Sign)

ReviewedB.

c Z..k

.Date:________

(Emergency Plan Coordinator) (Print/SiA VYAPF 3532.01 AP 3532 Rev. 11 Page 3 of 3

APPENDIX C CROSS-DISCIPLINE REVIEW CHECKLIST Required to be completed for new procedures, procedure revisions, and LPCs unless they are designated as Editorial.

ProcedureNumber/Revision OP 3547. Rev. 2 Reviewer/Date(Print) AudrpWilliamq Rnl3

--- --- -- - - --- N-GENERAL REVIEW GUIDELINES/SPECIAL REVIEW REQUIREMENTS The Cross-Discipline Review Guidelines below constitute minimum review requirements; other reviews may apply.

Determination of reviews should focus on changes made to a procedure and the potential impact of those changes on the affected group. Changes that are minimally or nonimpacting do not need review by the potentially affected group.

If change impact is unclear, the procedure should be routed to the potentially affected group for review.

New or revised Administrative or Program Procedures that significantly impact other departments, shall be reviewed by the appropriate Superintendent or Senior Manager. The PAA maintains a list of these Administrative and Program Procedures.

ALL noneditorial changes to Special Process procedures (WP, NE, heat treating, etc.), including Vendor Procedures that address Special Processes, shall be reviewed by: a Welding Engineer (welding procedures) or a NDE Level III certified in the method addressed by the procedure (nondestructive examination procedures), AND the Quality Assurance Manager, AND submitted to the Authorized Nuclear Inservice Inspector (ANTI) prior to use.

A "YES" indicates that a Cross Discipline Review shall be done by the indicated Department. Document the review on VYAPF 0096.01, WAPF 0097.01, or VYAPF 0097.02, as applicable.

APPLICABLE YES I

NO Chemistry:

Potentially affects condensate, feedwater, or reactor water chemistry, or chemistry instruments.

Procedures that implement the requirements of the VY Environmental Program.

(see PP 7603, Appendix A)

Produces/affects effluents or effluent monitoring (VY/QA 01-015).

Affects NPDES limits or method of compliance.

X Maintenance (Mech, Elec, I&C):

Requires Maintenance personnel to perform activities, such as performance of maintenance procedures, installation of M&TE, lifting and landing of leads and connectors.

X Operations:

Changed requirements for entry into a Limiting Condition for Operation (LCO) or significantly changes duration of LCO.

Requires Operations alignment/restoration of systems or components.

Specifies surveillance or post maintenance testing by Operations.

X EOPISAG Coordinator.

Procedures that have the potential to affect the EOPs/SAGs.

X Appendix C AP 0096 Rev. 3 Page 1of 3

APPENDIX C (Continued)

APPLICABLE YES NO Quality Assurance:

Changes to procedures that implement the requirements of the VOQAM. (see PP 7802, Appendix B)

New procedures that have a potential for reduction of VOQAM commitments.

Obtain and attach a IOCFR50.54(a)(3) evaluation.

X Radiation Protection:

Involves work in contaminated areas and high radiation areas.

  • -Involves work that breaches contaminated systems or components.

Changes in radwaste or hazardous waste generation.

X Emergency Plan Coordinator.

Emergency Plan Implementing Procedures.

Obtain and attach a 10CFR50.54(q) Evaluation.

Affects Emergency Plan personnel, facilities or equipment X

Software Quality Assurance Administrator Procedures that define how software is developed.

X Reactor Engineering:

Could affect core reactivity, thermal power, reactor heat balance, or fuel integrity.

Involves refueling operations.

X Systems/Project/Design Engineering:

Maintenance Rule in-scope systems unavailability time.

Involves infrequently performed test or evolution.

Changed requirements for entry into a Limiting Condition for Operation (LCO) or significantly changes duration of LCO.

Significant changes in system test or operation methodology.

X Appendix J Coordinator:

Changes that affect App. J leakrates or containment boundaries, or boundary valve manipulation.

X Appendix R Coordinator.

Appendix R implementing procedures.

X Environmental Qualification (EQ) Coordinator:

Change in EQ test methodology or component lifetime.

Potentially affects area EQ component environment.

X Fire Protection Coordinator (FPC):

Fire Protection procedures.

Affects fire loading Affects fire barrier integrity.

Affects fire protection systems or component functionality.

X IST Program Coordinator:

Inservice Testing Program implementing procedures.

All surveillance procedures.

X 1ST Program Coordinator.

Inservice Inspection Program implementing procedures.

X Appendix C AP 0096 Rev. 3 Page 2 of 3

APPENDIX C (Continued)

APPLICABLE YES I

NO Setpoint Coordinator:

Changes that impact setpoints, as-found/as-left tolerances, M&TE or testing methodology.

X l Nuclear & PRA Potentially affects IPEEE or ORAM Sentinel Risk Models.

Potentially affects plant SSCs reliability.

Potentially affects Nuclear or Radiological Safety Analysis.

X Security:

Proceures that implement the requirements of the VY Physical Security and Training and Qualification Plans.

Changes that have a potential for reduction of the VY Physical Security and Training and Qualification Plan commitments.

Obtain and attach a IOCFR50.54(P) Evaluation.

X Appendix C AP 0096 Rev. 3 Page 3 of 3

VERMONT YANKEE NUCLEAR POWER STATION cam=

E E U-OP 3547 REVISION 2 SECURITY ACTIONS DURING AN EMERGENCY USE CLASSIFICATION: REFERENCE LPC Effective No.

Date Affected Pages Implementation Statement: N/A Issue Date:

09/24/03 OP 3547 Rev. 2 Page I of 8

TABLE OF CONTENTS PU R PO SE..........................................................................................................................................................................

3 D ISC U SSSION............................................................................................,............................................................. 3 A¶ITACHNS..........

4 QA REQUIREMETS CROSS REFERENCE...........

4 REFERENCES AND COMMITMENTS........................................................................................................4 PRECAILJIONS/LMIITATIONS...........

5 PROCEDURE 6

1.0 Immediate Actions............

6 2.0 Subsequent Actions:..................................................................................................................8 FINAL CONDiTIONS 8

OP 3547 Rev. 2 Page 2 of 8

PURPOSE To outline the actions required by Security personnel when an emergency is declared.

DISCUSSION There are four emergency classifications, Unusual Event, Alert, Site Area Emergency, and General Emergency. The decision to make an immediate initial declaration rests with the Shift Manager/Plant Emergency Director, who, in turn, instructs Control Room personnel to activate the notification system. Notification of State authorities must be initiated within 15 minutes after the event has been classified. The NRC must be notified immediately after the States' notification, but not later than one (1) hour after the event has been classified.

An Unusual Event is defined as any plant-related event which indicates a potential degradation of plant safety margins which is not likely to affect personnel on-site or the public off-site or result in radioactive releases requiring off-site monitoring. Unusual Event conditions will not have caused serious damage to the plant and may not require a change in operation status.

The basic shift complement is able to deal with Unusual Event conditions. On-duty personnel are assigned to functions as required. Additional members of the plant organization, including top management, are notified by Plant Security, and augment on-duty personnel as necessary. The Duty On Call Officer who is available on an on-call basis must report to the site and will assume the role of the TSC Coordinator. Dissemination of public information and closure or escalation to a more severe classification will occur as conditions warrant An Alert event is defined as an indication of a substantial degradation of plant safety margins which could affect on-site personnel safety, could require off-site impact assessment, but is not likely to require off-site protective action.

An Alert event requires action beyond the normal capability of the basic shift complement. Plant response and off-site notification associated with this event classification ensure that sufficient emergency response personnel are mobilized to activate the Technical Support Center and the Operations Support Center. The Emergency Operations Facility/Recovery Center is activated with the Site Recovery Manager, the EOF Coordinator and other EOF/RC staff members. Sufficient emergency assistance personnel to assess off-site radiological impact are assigned if the Alert event is producing releases off-site. Actual releases of radioactivity which substantially exceed Technical Specification limits may be involved and thus radiation monitoring and dose projection may be an integral portion of the emergency response required. Prompt notification is made to State authorities and follow-up information is provided as needed to off-site emergency organizations.

A Site Area Emergency indicates an event which involves likely or actual major failures of plant functions needed for the protection of the public. The possibility does exist for some releases of radioactive material and response to this event emphasizes the ability to monitor the releases and to provide action recommendations to State authorities and follow-up information as needed to off-site emergency organizations.

OP 3547 Rev. 2 Page 3 of 8

Plant resources are anticipated to be sufficient to cope with a Site Area Emergency.

Outside resources, however, are mobilized and selected members are dispatched to the site. All emergency centers are activated following declaration of a Site Area Emergency. All non-essential personnel are 6vacuated from the site. Representatives from adjoining States are dispatched to the Emergency Operations Facility. Assessment of plant conditions and otf-site radiological parameters determine the type of protective measures necessary for protection of the public sector. The public is notified of the event by local media facilities and periodic updates of information are released to ensure uniform, adequate response to real conditions.

A General Emergency is declared when substantial core degradation or melting has occurred, with a potential for loss of containment integrity. The possibility does exist for releases of radioactive material and response to this event emphasizes the ability to monitor the releases and to provide for protective action recommendations to State authorities.

Contracted service organizations, sponsor utilities, and other industry resources are alerted and requested to render assistance as appropriate. In addition, Federal resources are called upon for assistance. Assessment of plant conditions and off-site radiological parameters determine the type of protective action recommendations.

Plant representatives closeout or escalate the emergency classification, or move to recovery as conditions warrant. Written summaries of the event are provided to off-site authorities and other affected agencies.

The Security Shift Supervisor (SSS) is responsible for initiating this procedure following an emergency classification announcement. If an evacuation is called for, the SSS will ensure personnel accountability in accordance with OP 3524.

In accordance with AP 6002, Preparing 50.59 Evaluations, the results of an Applicability Determination (AD) has determined that an AD is not required for future changes provided the procedure scope is not changed. The basis for this conclusion is that this document is an Emergency Implementing Procedure and is subject to 10CFR50.54(q) to determine if the changes decrease the effectiveness of the Emergency Plan and if they have the potential to affect our ability to meet the standards of 10CFR50.47(b) and the requirements of 10CFR50 Appendix E.

ATTACHMENTS

1.

None QA REQUIREMENTS CROSS REFERENCE

1.

None REFERENCES AND COMMITMENTS

1.

Technical Specifications and Site Documents

a.

Vermont Yankee Nuclear Power Station Emergency Plan OP 3547 Rev. 2 Page 4 of 8

a

2.

Codes, Standards and Regulations

a.

None

3.

Commitments

a.

None

4.

Supplemental References

a.

AP 0009, Event Reports

b.

AP 0010, Situational Reporting Requirements

c.

AP 0021, Work Orders

d.

AP 0156, Notification of Significant Events

e.

ENN-OM-105, Fitness for Duty Program

f.

AP 3125, Emergency Plan Classification and Action Level Scheme

g.

OP 3504, Emergency Communications

h.

OP 3507, Emergency Radiation Exposure Control

i.

OP 3524, Emergency Actions to Ensure Initial Accountability and Security

Response

j.

OP 3531, Emergency Call-in Method

k.

OP 3540, Control Room Actions During an Emergency

1.

OP 3541, Activation of the Technical Support Center (TSC)

m.

OP 3542, Operation of the Technical Support Center (TSC)

n.

OP 3544, Operation of the Operations Support Center (OSC)

o.

OP 3545, Activation of the Emergency Operations Facility/Recovery Center EOF/RC

p.

OP 3546, Operation of the Emergency Operations Facility/Recovery Center EOF/RC

q.

AP 6807, Collection, Temporary Storage and Retrieval of QA Records PRECAUTIONS/LIMITATIONS

1.

Refer to OP 3504 for alternate methods of communication in the event that primary methods fail.

OP 3547 Rev. 2 Page 5 of 8

PROCEDURE NOTES The responsible individual may assign actions required to other personnel as appropriate. The designated individual, however, has the overall responsibility for the execution of the checklist.

Record time and initials as required.

Steps may be performed concurrently or out of sequence.

Some steps have multiple signature lines, based on event level.

The step should be initialed for each event level it is completed for. If an event escalates, each step with that event level designator should be re-checked to ensure no further action is required.

Security Shift Supv. Name (print):

Date:

TimeJDate Initials 1.0 Immediate Actions NOTE IF an emergency classification is entered due to a security condition, THEN evacuation and accountability may put personnel at risk.

Therefore, in these situations evacuation and accountability will be suspended until directed by Security.

1.1.

Dial x5959 and notify Security personnel located in bullet resistant enclosures (BREs) of the emergency classification and declaration time.

U I

A I

S i

G I

(circle one)

U A

S G

1.2.

Implement OP 3531, Emergency Call-in Method.

/

OP 3547 Rev. 2 Page 6 of 8

Time/Date Initials 1.3.

Supplement security staffing and request outside Law Enforcement, Fire Department, and Medical assistance as necessary or as requested by the Operations Shift Manager/Plant Emergency Director.

U_

I A

I S

/

I G

I 1.4.

If deemed necessary, at ALERT or higher, ensure Security has been assigned for contractor and visitor control at Gate 1.

(circle one)

A S

G l

1.5.

At ALERT and higher, ensure accountability of personnel has been completed in accordance with OP 3524.

(circle one)

A S

G l

1.6.

Notify the Wilder Station by dialing 9-1-802-291-8000 and, when a member of the watch staff answer the phone, state the following:

"This is Vermont Yankee Nuclear Power Station in Vernon, Vermont. We have a(n)

I repeat, this is Vermont Yankee Nuclear Power Station in Vernon, Vermont. We have a(n)

Please acknowledge with your name."

Name of Watch Staff Member (circle one)

U A

S G

I 1.7.

Post the appropriate emergency classification sign in an obvious location on the front of the Gate II desk.

(circle one)

U A

S G

I.

1.8.

IF ALERT, or higher, THEN arrange for Fitness-For-Duty Collection Site Staff to be available at the EOF and the Plant.

(circle one)

A S

G l

OP 3547 Rev. 2 Page 7 of 8

Time/Date 1nitials 2.0 Subsequent Actions:

NOTE If the switchboard is staffed, ensure the operator is aware of transferring calls.

2.1.

Route phone calls from State officials to the Site Recovery Manager at the EOF/RC or TSC Coordinator at the TSC (if EOF/RC is not staffed) or Control Room (if TSC is not staffed).

2.2.

Ensure the Switchboard Operator has the necessary information on the emergency classification.

(circle one)

U A

S G

l U

I A

I S_

G I

FINAL CONDITIONS

1.

Return completed procedure to the Emergency Plan Coordinator for filing in accordance with AP 6807.

OP 3547 Rev. 2 Page 8 of 8

I PREAPPROVED LPC FORM

<v> I PART 1-Initiation El Converted to Admin. Revision #

LPC No: i)

A. Procedure No.:

OP 3506 Current Revision #:

43

Title:

Emergency Eq1fiient l

l Readiness Check B. Description of Change:

Added instructions on checking operability of Rtime and what to do if not operational.

Took away the responsibility of RP (VYOPF 3506.02) to check the PARD and put it in VYOPF 3506.08.

Added instructions on how to test the PARD n VYOPF 3506.08.

C. Reason for Change: E] Result of Design Change, Minor Mod, EDCR ED Related ER No.

0 Other___

a Editorial D. Duration:

0 Permanent EOne Time Only I. Originator (Print/Sign/Date)

. Surveillance Database Change? a Yes, change submitted 0 No (Use AP 0096, App. A as a reference) 0 Technicalance DatAdaienCh(APePP)

(Complete & attach AP 0096 App. C, F. Procedure Type:

Z Technical a Admin. (APPP) unless editorial)

G. AP 0091, Risk Assessmecit< E Yes 0 No Audn William 7/31/03 H. Page(s) affected: page lI of 16. VYOPF 3506.02 pvs 3. 89.17.26 of X

27. VYOPF 3506.08 Rgs 2.3 of 3 aeJJ 53A b e,

i d

PART 2 - Review/Approval (Refer to LPC Criteria of A ndix A A. Technical Verification Review (Print/Sign/Date) (Use B. Cross-Discipline Review(s) (Print/Sign/Date)

AP 0096, Appendix B as a reference)

E N/A Ea N/A La A 4 A OtA~L.

e Audra Williams 7/31/03 (May perform Qualified Review) (N/A if editorial change)

C. Qualified Review (Print/Sign/Date) (Use AP 0096, D. 50.59 review completed type:

Appendix D, as a reference)

El N/A El AD/Screen El Evaluation 0 N/A

'k&t 1a i ~Iiaml OZ6&-I~r 7/31/03 (N/A if editorial change)

Wi~~liams

( J

~~~7/31/03 (V/A if editorial change) 0 50.54(q) (EPIP only)

E. RPO Approval (Print/Sign/Date)

F. IF 50.59 Evaluation:

0 N/A Brian/Finn,4

)

pe/#3 l

PORC Mtg.

Date:

Brian Finn

a.

o

/A G. Plant Manager (Print/Sign/Date) (SPs only)

N/A H. Training: (Required for Admin Procedures, unless editorial) 0 N/A E-mail to RP and E-Plan I. Effective Date:

K3 ZZ

-- O1a$8\\

Al

,~~~~~~~~~0A I

CDS Initials-h3L.

VYAPF 0097.02 AP 0097 Rev. 3 Page 1 of 1

APPENDIX C CkOSS-DISCIPLINE REVIEW CHECKLIST Required to be completed for new procedures, procedure revisions, and LPCs unless they are designated as Editorial.

Procedure Number/Revision OP 3506. Rev. 43. LPC #1 Reviewer/Date (Print) Audra Williams 7/31/03 GENERAL REVIEW GUIDELINES/SPECIAL REVIEW REQUIREMENTS The Cross-Discipline Review Guidelines below constitute minimum review requirements; other reviews may apply.

Determination of reviews should focus on changes made to a procedure and the potential impact of those changes on the affected group. Changes that are minimally or nonimpacting do not need review by the potentially affected group.

If change impact is unclear, the procedure should be routed to the potentially affected group for review.

New or revised Administrative or Program Procedures that significantly impact other departments, shall be reviewed by the appropriate Superintendent or Senior Manager. The PAA maintains a list of these Administrative and Program Procedures.

ALL noneditorial changes to Special Process procedures (WP, NE, heat treating, etc.), including Vendor Procedures that address Special Processes, shal be reviewed by: a Welding Engineer (welding procedures) or a NDE Level III certified in the method addressed by the procedure (nondestructive examination procedures), AND the Quality Assurance Manager, AND submitted to the Authorized Nuclear Inservice Inspector (ANII) prior to use.

A "YES" indicates that a Cross Discipline Review shall be done by the indicated Department. Document the review on VYAPF 0096.01, VYAPF 0097.01, or VYAPF 0097.02, as applicable.

APPUCABLE YES I

NO Chemistry:

Potentially affects condensate, feedwater, or reactor water chemistry, or chemistry instruments.

Procedures that implement the requirements of the W Environmental Program.

(see PP 7603, Appendix A)

Produces/affects effluents or effluent monitoring (VY/QA 01-015).

Affects NPDES limits or method of compliance.

X Maintenance (Mech, Elec, I&C):

Requires Maintenance personnel to perform activities, such as performance of maintenance procedures, installation of M&TE, lifting and landing of leads and connectors.

X Operations:

Changed requirements for entry into a Limiting Condition for Operation (LCO) or significantly changes duration of LCO.

Requires Operations alignment/restoration of systems or components.

Specifies surveillance or post maintenance testing by Operations.

X EOP/SAG Coordinator:

Procedures that have the potential to affect the EOPs/SAGs.

X Appendix C AP 0096 Rev. 3 Page I of 3

APPENDIX C (Continued)

I Quality Assurance:

Changes to procedures that implement the requirements of the VOQAM. (see PP 7802, Appendix B)

New procedures that have a potential for reduction of VOQAM commitments.

Obtain and attach a I0CFR56.54(a)(3) evaluation.

Radiation Protection:

Involves work in contaminated areas and high radiation areas.

Involves work that breaches contaminated systems or components.

Changes in radwaste or hazardous waste generation.

Emergency Plan Coordinator:

Emergency Plan Implementing Procedures.

Obtain and attach a IOCFR50.54(q) Evaluation.

Affects Emergency Plan personnel, facilities or equipment.

Software Quality Assurance Administrator Procedures that define how software is developed.

Reactor Engineering:

Could affect core reactivity, thermal power, reactor heat balance, or fuel integrity.

Involves refueling operations.

Systems/Project/Design Engineering:

Maintenance Rule in-scope systems unavailability time.

Involves infrequently performed test or evolution.

Changed requirements for entry into a Limiting Condition for Operation (LCO) or significantly changes duration of LCO.

Significant changes in system test or operation methodology.

Appendix J Coordinator.

Changes that affect App. J leakrates or containment boundaries, or boundary valve manipulation.

Appendix R Coordinator:

Appendix R implementing procedures.

Environmental Qualification (EQ) Coordinator:

Change in EQ test methodology or component lifetime.

Potentially affects area EQ component environment.

Fire Protection Coordinator (FPC):

Fire Protection procedures.

Affects fire loading Affects fire barrier integrity.

Affects fire protection systems or component functionality.

IST Program Coordinator:

Inservice Testing Program implementing procedures.

All surveillance procedures.

ISI Program Coordinator.

Inservice Inspection Program implementing procedures.

Appendix C AP 0096 Rev. 3 Page 2 of 3

APPENDIX C (Continued)

APPLICABLE YES NO Setpoint Coordinator:

Changes that impact setpoints, as-found/as-left tolerances, M&TE or testing methodology.

X Nuclear & PRA Potentially affects IPEEE or ORAM Sentinel Risk Models.

Potentially affects plant SSCs reliability.

Potentially affects Nuclear or Radiological Safety Analysis.

X Security:

Proceures that implement the requirements of the VY Physical Security and Training and Qualification Plans.

Changes that have a potential for reduction of the VY Physical Security and Training and Qualification Plan commitments.

Obtain and attach a I OCFR50.54(P) Evaluation.

X Appendix C AP 0096 Rev. 3 Page 3 of 3

10 CFR 50.54(q) Evaluation Checklist List of Emergency Plan Section(s)/Emergency Plan Implementing Procedure(s) or any other document to be evaluated. (Include Title and Revision No.):

OP 3506, Rev. 43, LPC #I - Emergency Equipment Readiness Check A.

Screening Evaluation Based on a review of the following questions, determine if the change has the potential to affect our ability to meet the standards of 10 CFR 50.47(b) and the requirements of Appendix E to 10 CFR 50.

A "YES" answer to any part of the questions requires that a written evaluation be done to determine whether the effectiveness of the Emergency Plan was decreased as specified in Section B of this checklist.

A "NO" answer to all questions requires no written evaluation as specified in Section B of this checklist.

Could the proposed change affect our ability to meet the following standards of 10CFR50A7(b):

(1)

Assignment of Emergency Response Organization responsibilities (2)

Assignment of on-shift Emergency Response Organization personnel (3)

Arrangements for Emergency Response Support and Resources (4)

Emergency Classification and Action levels, including facility system and effluent parameters (5)

Notification Methods and Procedures (6)

Emergency Communications among principal response organizations and the public (7)

Public Education and Information (8)

Adequacy of Emergency Facilities and Equipment (9)

Adequacy of Accident Assessment methods, systems and equipment (10)

Plume exposure pathway EPZ protective actions (11)

Emergency Worker Radiological Exposure Control (12)

Medical Services for contaminated injured individuals (13)

Recovery and Reentry Plans (14)

Emergency response periodic drills and exercises (15)

Radiological Emergency Response Training (16)

Plan development, review and distribution i

YES

. NO X

X X'

X X

X I

X X~~

'X X

X x

x x

x VYAPF 3532.01 AP 3532 Rev. 11 Page 1 of 3

10 CFR 50.54(q) Evaluation Checklist (Continued)

YES _

NO

2.

Could the change affect our ability to meet the following requirements of Appendix E to I0CFR50 (I)

Section IV. A - Organization (2)

Section IV. B - Assessment Actions (3)

Section IV. C - Activation of Emergency Organizations (4)

Section IV. D - Notification Procedures (5)Section IV. E - Emergency Facilities and Equipment (6)

Section IV. F - Training (7)

Section IV. G - Maintaining Emergency Preparedness (8)

Section IV. H - Recovery X

X.

X X

X X

X X

B.

Effectiveness Determination For each applicable (i.e., a "yes" answer specified) standard to IOCFR50.47(b) and Appendix E to IOCFR50 identified from Section A above, complete the evaluation form below to determine whether the change decreases the effectiveness of the Emergency Plan and whether it continues to meet the stated applicable standard or requirement.

A facsimile of the evaluation form may be used as needed and attached to this checklist.

IFor applicable item I0CFR50 A.47(bX8) & App E (5) of Section A above, this change O DOES 0 DOES NOT decrease the effectiveness of the Emergency Plan and 0 DOES El DOES NOT continue to meet the stated applicable standard or requirement.

BASIS FOR ANSWER:

Adding text for checking the operability of Rtime ensures that the software is operational and, if not, the method to get it repaired. Adding the responsibility of performing operational checks of the PARD phone to E-Plan ensures that the circuit is being checked on a monthly basis and is operational. Although not all new wireless headset phones that were installed in the TSC/EOF/OSC are specifically called out in the procedure, the phones/headsets themselves will be checked for operability at the same time the phone circuits are checked. This will be done per *OPF 3506.08.

All of these changes are enhancements to the procedure and are helping to ensure operability of the equipment.

VYAPF 3532.01 AP 3532 Rev. 11 Page 2 of 3

10 CFR 50.54(q) Evaluation Checklist (Continued)

C.

Conclusion (Fill out appropriate information) 3 The changes made do not decrease the effectiveness of the Emergency Plan and continue to meet the standards of IOCFR50.47(b) and the requirements of Appendix E to 10CFR50.

El The changes made do decrease the effectiveness of the Emergency Plan and decrease our ability to meet the standards of 10CFR50.47(b) and the requirements of Appendix E to 10CFR50. The following course of action is recommended:

C]

Revise proposed changes to meet applicable standards and requirements.

ED Cancel the proposed changes.

El Process proposed changes for NRC approval prior to implementation in accordance with IOCFR50.54(q).

D.

Impact on Other Documents (IRM, Tech Specs)

Keywords used in search:

El This change does not affect any other documents.

§3 This change does affect other documents.

Document(s) affected: OP 3504 Section(s) affected:

E.

Impact on the Updated FSAR Use AP 6036 to determine if the proposed E-Plan change modifies existing UFSAR information or requires the addition of new UFSAR information and initiate UFSAR change(s) as required.

Keywords used in UFSAR search:_-

Additional Comments:

Prepared By: AudraWilliams 61

.M 0 ate: 7/31/03 (Print/Sign)

Reviewed By: L, 1A,.7 c3tt M

Date: 713, 1Q3 (Emergency Plan oordinator) (Print/Sigh VYAPF 3532.01 AP 3532 Rev. 11 Page 3 of 3

VERMONT YANKEE NUCLEAR POWER STATION

.~~~ T L i'GE

- OP 3506 REVISION 43 EMERGENCY EQUIPMENT READINESS CHECK USE CLASSIFICATION: REFERENCE LPC Effective Affected Pages No.

Date 1

09/24/03 10 & 11 of 16, VYOPF 3506.02 Pgs 3, 8, 9, 17 & 26 of 27, VYOPF 3506.08 Pgs 2, 3 & ADDED Pg 3A of 3 I

I Implementation Statement: N/A I

Issue Date:

07/23/2003 OP 3506 Rev. 43 Page 1 of 16

5.

Route VYOPF 3506.01 to the Shift Supervisor for review.

6.

Forward VYOPF 3506.01 to the Emergency Plan Coordinator (EPC) for review.

7.

The EPC will file VYOPF 3506.01 in accordance with AP 6807.

B.

Quarterly Emergency Equipment Check (RP)

(Use VYOPF 3506.02)

NOTE VYOPF 3506.07 can be used as an aid in determining the locations of copies of controlled procedures and forms, which are located outside their normal controlled locations.

1.

Refer to any control copy and list the current revision and Department InstructionALPC of the procedures and forms listed on VYOPF 3506.07.

2.

Obtain a copy of VYOPF 3506.02.

3.

Contact the Emergency Plan Coordinator (EPC) for any special instructions.

4.

Inventory Emergency kit and cabinet contents against material listed on VYOPF 3506.02.

5.

If necessary, update any copies of procedures or forms specified on VYOPF 3506.02. Refer to VYOPF 3506.07 for current Rev. and LPC Nos.

6.

Check operability of telephones and associated phone jacks listed on VYOPF 3506.02.

7.

Replace material and instrumentation as required. Materials and instruments whose calibration, expiration, or shelf life will expire prior to the next scheduled performance of this portion of OP 3506 should be replaced.

8.

Attach an initialed and dated seal to the kit.

9.

Make notes on the status of equipment and correct all deficiencies.

10.

Check operability of Rtime on specified computers by locating icon on desktop LtC.

(or through program menu) and opening application. If not operational, a remedy case is to be submitted to IT for repair.

OP 3506 Rev. 43 Page 10 of 16 LPC#1

11.

Submit the completed VYOPF 3506.02 to the RP Supervisor, who will ensure the following:

a.

Anypending corrective actions are summarized (e.g., Work Request Nos.

are listed) and projected completion dates are specified.

b.

All corrective actions have been taken in response to any deficiencies noted.

12.

The RP Supervisor will submit VYOPF 3506.02 to the EPC who will do the following:

a.

Review any pending corrective actions for appropriateness and timeliness (i.e., is projected completion date reasonable to ensure emergency preparedness).

b.

Review corrective actions for appropriateness.

c.

Approve status of the emergency kits and cabinets.

13.

The EPC will, upon receipt of VYOPF 3506.02, identify any discrepancies, state corrective actions taken in a memo to file, and file in accordance with AP 6807.

C.

Quarterly Brattleboro Memorial Hospital Emergency Equipment Check (RP)

(Use VYOPF 3506.03)

1.

Refer to any control copy of OP 3508 and list the current revision and Limited Procedure Change of the procedure on VYOPF 3506.03, as applicable.

2.

Proceed to the BMH Emergency Wing.

3.

Inventory the emergency kits contents against those items listed on VYOPF 3506.03.

4.

Replace material and instrumentation as required. Materials and instruments whose calibration, expiration, or shelf life will expire prior to the next scheduled performance of this portion of OP 3506 should be replaced.

5.

Make notes on the status of equipment and correct all deficiencies.

6.

Submit the completed VYOPF 3506.03 to the RP Supervisor, who will ensure all corrective actions have been taken in response to any deficiencies noted.

7.

The RP Supervisor will submit VYOPF 3506.03 to the EPC who will review it and approve the status of the emergency kits.

8.

The EPC will file VYOPF 3506.03 in accordance with AP 6807.

OP 3506 Rev. 43 Page I1 of 16 LPC #1

EMERGENCY EQUIPMENT CHECKLIST (Continued)

ITEMS INITIALS

31.

OT 3100 Reactor Scram -

Laminated hard card.

=OTE Operability of the FTS and NAS phones is checked by Emergency Planning using VYOPF 3506.08.

32.

Telephones in Cabinet #1:

a.
  1. 1- (NAS)

(Checked by E-Plan monthly)

I-fC-

b.
  1. 6
c.
  1. 8 -

Speakerphone (for Media Advisor)

d.
  1. 3A - Alternate Auto Ring Down Phone and EASA-PHONE speaker. (Use to contact Control Room)
33.

Telephones, wall mounted in Recovery Planning Area (Room 126):

a.
  1. 3 (Primary Ringdown) with headset (not wall mounted)
b.
  1. 3A (Alternate Ringdown)
c.

120

d.
  1. 19
e.
  1. 33
f.
  1. 40
g.

141

h.
  1. 61 (Powerfail)-
i.
  1. 69 (FTS)

(Checked by E-Plan monthly)

j.
  1. 70 (FTS)
k.
  1. 75 (FTS)

(Checked by E-Plan monthly)

(Checked by E-Plan monthly)

(Checked by E-Plan monthly)

34.

PC and multi-media computer (2)

(Room 126 & 125)

VYOPF 3506.02 OP 3506 Rev. 43 Page 3 of 27 LPC #1

EMERGENCY EQUIPMENT CHECKLIST (Continued)

ITEMS INITIALS

5.

High Range Dosimeters (20)

a.

Calibration Up-To-Date

6.

Gamma Dose Rate Meter (2)

a.

Battery Check OK

b.

Calibration Up-To-Date

7.

Flashlights (12)

8.

Batteries (12)

9.

Check Source (Strength >1 mR/hr but <4 mR/hr)

10.

Telephones:

(mounted in Chem.

& Sample Analysis Lab)

a.
  1. 14
b.
  1. 15
11.

SAM-II Ba-133 Source E.

Room #118 for Use By Nuclear Regulatory Commission Personnel (Cal. Due Date)

(Room 120)

(Room 120)

(NRC) Emergency Response NOTE The Fax machine will be brought to the facility by NRC emergency responders.

1.

Telephones:

(Wall Mounted unless other wise specified)

a.
  1. 16
b.
  1. 17
c.
  1. 18
d.
  1. 57
e.
  1. 73 (FTS)
f.
  1. 74 (FTS)

(Room 118)

(Room 118)

(Room 118)

(Room 118)

(Checked by E-Plan monthly)

(Checked by E-Plan monthly)

(Room 118)

(Room 118)

VYOPF 3506.02 OP 3506 Rev. 43 Page 8 of 27 LPC #1

_

LPC_ I

g.
  1. 89
h.
  1. 90
2.

Computer with RTIME operational (PSS)

EMERGENCY EQUIPMENT CHECKLIST (Continued)

ITEMS INITIALS F.

Room #123 OSMT Communications Area

1.

UHF Radio Transmitter/Receiver Systems (2)

2.

Area Map/Dispersion Wheel"

3.

10 Mile EPZ Map

4.

Air Sample codes for I-131 Air concentrations

5.

Field Sample Thyroid Dose Nomogram

6.

Site Boundary Map

7.

Decnet Terminal

8.

Telephones:

(wall mounted)

a.
  1. 29 (Powerfail)

, (Room 123)

b.
  1. 30 (Room 123)

G.

Room #128 for Use by EOF Engineering Support Group

1.
  1. 62 (Room 128)
2.
  1. 65 (Room 128)
3.
  • 13 (Room 127)
4.
  1. 63 (2)

(Room 127)

5.

Computer with RTIME Operational (PSS)

VYOPF 3506.02 OP 3506 Rev. 43 Page 9 of 27 LPC #1

EMERGENCY EQUIPMENT CHECKLIST (Continued)

ITEMS INITIALS F.

All equipment and materials returned to the kits and the kits sealed G.

RP Checkpoint

1.

OSC Dosimetry Kit

a.

Dosimeters

1) 20 Self Reading Dosimeters (SRDs)
2) 1 SRD Charger (AC)
3) 20 TLDs
4) 2 TLD Controls
5) 6 Extremity TLDs
6) 2 Extremity Controls
7)

High Range Dosimeters (13)

(located in drawer) ttC YI-I a)

Calibration up-to-date (Cal. Due Date)

I I

b.

Procedures

1)

AP 0506, Personnel Monitoring

2)

AP 0525, Dosimetry Processing

3)

AP 0546, Planned Special Exposure

4)

OP 3507, Emergency Radiation Exposure Control I

I C.

Forms 1) 2)

3) 4)

I NRC Form 4 Exposure History Release Forms General Access RWP VYAPF 0525.06, Pregnant Woman Declaration Form I

VYOPF 3506.02 OP 3506 Rev. 43 Page 17 of 27 LPC #1

EMERGENCY EQUIPMENT CHECKLIST (Continued)

ITEMS INITIALS fICl

37.

TSC Phone Jacks (ER981874-02)

a.
  1. 18
b.
  1. 21
c.
  1. 22 (Primary Auto Ringdown Circuit)
d.
  1. 26 (wall mounted)
e.
  1. 27 (wall mounted)
f.

128

g.
  1. 29
h.
  1. 34
i.
  1. 55 (copier room)
j.
  1. 56 (cordless)

C.

Computers with RTIME (connected to Plant ERFIS)

1.

General Manager's office operational

2.

NRC Resident Inspector's office operational (Checked by E-Plan monthly)

I Performed by:

(Print/Sign)

Date:

VYOPF 3506.02 OP 3506 Rev. 43 Page 26 of 27 LPC #1

TSCIEOF FrS AND NAS PHONE CHECKLIST (Continued)

2.

Test Nuclear Alert System (NAS) Orange Phone:

a.

Place a call to each of the three states NAS extensions as specified below, requesting a call back to ensure system operability.

SRM Office (NAS #1, Ext. 511)

Date:_

Call Out:

Return Call:

Time Time_

VT (213)___

VT_

Contact Initials Contact Initials NH (212)

NH Contact Initials Contact Initials MA (210),

MA_

Contact Initials Contact Initials States Room (NAS #2, Ext. 411)

Date:_

Call Out:

Return Call:

Time_

Time_

VT (213)

VT Contact Initials Contact Initials NH (212)

NH Contact Initials Contact Initials MA (210)__

MA___

Contact Initials Contact Initials

3.

Test Primary Auto Ring Down Circuit phone in the SRM Office (#3):

a.

Using wireless headset phone, dial X4400 to initiate connection to the circuit. You will hear a message announcing that you have reached the Primary Auto Ring Down conference.

b.

When prompted for access code, enter: 1 2 3 4 5 6. You will then hear a message that you are the first party to join call and to hold for additional attendees. You can then hang up and disconnect call.

C.

Results Date Success establishment of circuit:

D YES D NO

4.

Test performed by:

(Print/Sign)

Date VYOPF 3506;08 OP 3506 Rev. 43 Page 2 of 3 LPC #1

TSC/EOF FTS AND NAS PHONE CHECKLIST (Continued)

B.

Technical Support Center - Vernon

1.

Test NRC FrS Phones Since all the FTS phones use the same telephone number(s) to contact the NRC Operations Center in Rockville, MD, the ENS phone is tested first to verify the operability of the circuit between Vernon and Rockville. The remaining FTS phones can be tested without contacting the NRC Operations Center.

a.

ENS Test the Vernon NRC FTS ENS line by using phone (#41) in the TSC Communications Room, and implementing the following steps:

1)

Lift the receiver and listen for the dial tone.

2)

After receiving a dial tone, dial the first number listed below (or on the sticker located on the telephone base) using all 11 digits. If the first number is busy, proceed on with the second number.

1-301-816-5100 1-301-951-0550 1-301-415-0550

3)

State your name, location, and the fact that you are testing the Vernon ENS. Request that the NRC staff member call back at 700-661-4323.

4)

Results Date:

Successful call to the NRC:

NRC

Contact:

Successful callback from the NRC:

NRC

Contact:

o YES 0 NO Time:

Q YES a

NO Time:

5)

If not completely successful in Step 4), notify the Control Room immediately.

VYOPF 3506.08 OP 3506 Rev. 43 Page 3 of 3 LPC#1

TSC/EOF FTS AND NAS PHONE CHECKLIST (Continued)

b.

Other NRC FTS Phones

1)

The remaining FTS phones in Vernon are tested by calling each FrS phone from a different FTS phone. The following FTS phones should be tested for operability:

Wall mounted in Communications Room

  1. 40 700-6614319
  1. 42 700-6614321
2)

Telephones are in the TSC cabinets. Find the phone labeled #39 and plug it into the outlet labeled #39 in the small office behind the communications room. Call that line from one of the wall mounted FTS phones to verify operability.

3)

Take two telephones from the TSC cabinets and test the four circuits in the NRC Office by calling each line. The outlets are on the far wall to the right as you walk in the door (OP 3504, Figure 4). They are labeled #43, #44, #45, and #47.

2.

Test Primary Auto Ring Down Circuit phone in the TSC (#22):

a.

Using wireless headset phone, dial X4400 to initiate connection to the circuit. You will hear a message announcing that you have reached the Primary Auto Ring Down conference.

b.

When prompted for access code, enter. 1 2 3 4 5 6. You will then hear a message that you are the first party to join call and to hold for additional attendees. You can then hang up and disconnect call.

)-T

c.

- Results Success establishment of circuit:

0 Date_

YES 0

NO 3.

Tract ---fr-n-A 1.-

I A.0U jfl%. LSJWA UW (Print/Sign)

Date Approved BY l

-0 EPC (Print/Sign)

Date VYOPF 3506.08 OP 3506 Rev. 43 Page 3A of 3 LPC#1