July 11, 2003 Mr. Dhiaa Jamil Vice President, McGuire Site Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, NC 28078-8985
SUBJECT:
WILLIAM B. MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 RE:
EMERGENCY PLAN REVISION OF EMERGENCY PLANNING ZONE (TAC NOS. MB8943 AND MB8944)
Dear Mr. Jamil:
By letter dated May 5, 2003, you submitted a proposed revision to the McGuire Nuclear Station, Units 1 and 2, Emergency Plan. The proposed change would revise the outermost section of Sector S of the Emergency Planning Zone boundary in response to the request of Gaston County and the town of Mount Holly.
The Nuclear Regulatory Commission staff has reviewed the information provided and has determined that additional information is required. Our questions are provided in the Enclosure.
We discussed these questions with your staff on July 8, 2003. Your staff indicated that a response could be provided by August 30, 2003.
Please contact me at (301) 415-1493, if you have any other questions on these issues.
Sincerely,
/RA/
Robert E. Martin, Senior Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50-370
Enclosure:
Request for Additional Information cc w/encl: See next page
ML031920002 OFFICE PDII-1/PM PDII-1/LA IEHB/SC PDII1/SC NAME RMartin CHawes EWeiss LOlshan for JNakoski DATE 07/8/03 07/10/03 07/10/03 07/10/03
REQUEST FOR ADDITIONAL INFORMATION ON EMERGENCY PLAN CHANGE DUKE POWER COMPANY WILLIAM B. MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 DOCKET NOS. 50-369 AND 50-370 1.
Discuss whether the McGuire Emergency Plan or procedures provide for Protective Action Recommendations (PARs) beyond 10 miles.
2.
Discuss the new distance from the plant to the Emergency Planning Zone (EPZ) edge as it relates to the town of Mt. Holly.
3.
Provide a map that delineates the area of Sector S that will no longer be in the EPZ.
4.
Discuss those actions being taken to ensure that the town of Mt. Holly is aware that if PARs beyond 10 miles are made, the town will be affected.
McGuire Nuclear Station cc:
Ms. Lisa F. Vaughn Legal Department (PBO5E)
Duke Energy Corporation 422 South Church Street Charlotte, North Carolina 28201-1006 County Manager of Mecklenburg County 720 East Fourth Street Charlotte, North Carolina 28202 Michael T. Cash Regulatory Compliance Manager Duke Energy Corporation McGuire Nuclear Site 12700 Hagers Ferry Road Huntersville, North Carolina 28078 Anne Cottingham, Esquire Winston and Strawn 1400 L Street, NW.
Washington, DC 20005 Senior Resident Inspector c/o U.S. Nuclear Regulatory Commission 12700 Hagers Ferry Road Huntersville, North Carolina 28078 Dr. John M. Barry Mecklenburg County Department of Environmental Protection 700 N. Tryon Street Charlotte, North Carolina 28202 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Road 12th Floor Charlotte, North Carolina 28210 Ms. Karen E. Long Assistant Attorney General North Carolina Department of Justice P. O. Box 629 Raleigh, North Carolina 27602 Mr. C. Jeffrey Thomas Manager - Nuclear Regulatory Licensing Duke Energy Corporation 526 South Church Street Charlotte, North Carolina 28201-1006 NCEM REP Program Manager 4713 Mail Service Center Raleigh, North Carolina 27699-4713 Mr. Richard M. Fry, Director Division of Radiation Protection North Carolina Department of Environment, Health and Natural Resources 3825 Barrett Drive Raleigh, North Carolina 27609-7721 Mr. T. Richard Puryear Owners Group (NCEMC)
Duke Energy Corporation 4800 Concord Road York, South Carolina 29745 Mr. H. B. Barron Vice President, McGuire Site Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, NC 28078-8985