A Duke Energy Company R. A. JONES Vice President Duke Power 29672 / Oconee Nuclear Site 7800 Rochester Highway Seneca, SC 29672 864 885 3158 864 885 3564 fax July 8, 2003 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555

Subject:

Oconee Nuclear Station Docket Nos. 50-269, -270, -287 Emergency Plan Implementing Procedures Manual Volume C Revision 2003-07 Please find attached for your use and review copies of the revision to the Oconee Nuclear Station Emergency Plan: Volume C Revision 2003-07, July 2003.

This revision is being submitted in accordance with 10 CFR 50-54(q) and does not decrease the effectiveness of the Emergency Plan or the Emergency Plan Implementing Procedures.

Any questions or concerns pertaining to this revision please call Rodney Brown, Emergency Planning Manager at 864-885-3301.

By copy of this letter, two copies of this revision are being provided to the NRC, Regtpn4II, Atlanta, Georgia.

Very R. A VP, Oconee Nuclear Site xc:

(w/2 copies of attachments)

Mr. Luis Reyes, Regional Administrator, Region II U. S. Nuclear Regulatory Commission 61 Forsyth St., SW, Suite 24T23 Atlanta, GA 30303 w/copy of attachments Mr. James R. Hall Rockville, Maryland (w/o Attachments, Oconee Nuclear Station)

NRC Resident Inspector J.

R. Brown, Manager, Emergency Planning

k4wS www. duke-energy. corn

July 8, 2003 OCONEE NUCLEAR SITE INTRASITE LETTER

SUBJECT:

Emergency Plan Implementing Procedures Volume C, Revision 2003-07 Please make the following changes to the Emergency Plan Implementing Procedures Volume C by following the below instructions.

REMOVE Cover Sheet 2003-06 Table of Contents page 1 & 2 RP/0/B/1000/017 -

11/04/02 EM 5.1,-Rev. 8 -

Engineering Emergency Response Plan - 07/17/02 XNSERT Cover Sheet 2003-07 Table of Contents page 1 & 2 RP/0/B/1000/017 -

07/02/03 EM 5.1,-Rev. 10 -

Engineering Emergency Response Plan -

07/02/03 NOTE:

EM 5.1, Rev.9 -

Engineering Emergency Response Plan 06/09/03 copy provided.

DUKE POWER EMERGENCY PLAN IMPLEMENTING PROCEDURES VOLUME C APPROVED:

Ii~~~~N.

W. W. Foster, Manager Safety Assurance 07/08/2003 Date Approved 07/08/2003 Effective Date VOLUME C REVISION 2003-07 JULY 2003

VOLUME C TABLE OF CONTENTS HP/O/B/1009/0 18 HP/0/B/1009/020 HP/O/B/1009/021 HP/0/B/1009/022 RP/O/B/1000/001 RP/0/B/ 1000/002 RP/0/B/1000/003 A RP/0/B/ 1000/007 RP/O/B/I000/009 RP/O/B/1000/010 RP/O/B/ 1000/015 A RP/0/B/1000/015 B RP/0/B/1000/015 C RP/O/B/1000/016 RP/O/B/ 1000/017 RP/0/B/ 1000/018 RP/O/B/ 1000/019 RP/0/B/ 1000/020 RP/0/B/ 1000/021 RP/O/B/ 1000/022 RP/0/B/ 1000/024 RP/0/B/1000/028 RP/0/B/ 1000/029 RP/0/B/ 1000/031 Off-Site Dose Projections Estimating Food Chain Doses Under Post Accident Conditions Source Term Assessment Of A Gaseous Release From Non-Routine Release Points On Shift Off-Site Dose Projections Emergency Classification Control Room Emergency Coordinator Procedure ERDS Operation Security Event Procedure For Site Assembly Procedure For Emergency Evacuation/Relocation Of Site Personnel Offsite Communications From The Control Room Offsite Communications From The Technical Support Center Offsite Communications From The Emergency Operations Facility Medical Response Spill Response Core Damage Assessment Technical Support Center Emergency Coordinator Procedure Emergency Operations Facility Director Procedure Operations Interface (EOF)

Procedure For Site Fire Damage Assessment And Repair Protective Action Recommendations Communications & Community Relations World Of Energy Emergency Response Plan Fire Brigade Response Joint Information Center Emergency Response Plan 1

08/29/02 10/09/98 12/01/97 04/08/03 02/11/03 08/29/02 01/21/03 08/29/02 05/06/03 02/26/03 12/11/01 12/11/01 12/11/01 09/12/02 07/02/03 09/30/97 01/27/03 12/11/02 11/04/02 06/02/03 11/10/99 02/17/97 04/22/03 06/12/00 Revision 2003-07 July 2003

SR/0/B/2000/001 Business Management SSG Functional Area Directive 102 NSC - 110 Engineering Manual 5.1 Human Resources Procedure Radiation Protection Manual Section 11.3 Radiation Protection Manual Section 11.7 Safety Assurance Directive 6.1 Safety Assurance Directive 6.2 Training Division VOLUME C TABLE OF CONTENTS Standard Procedure For Public Affairs Response To The Emergency Operations Facility Business Management Emergency Plan SSG Emergency Response Plan - ONS Specific Nuclear Supply Chain - SCO Emergency Response Plan Engineering Emergency Response Plan ONS Human Resources Emergency Plan Off-Site Dose Assessment And Data Evaluation Environmental Monitoring For Emergency Conditions Safety Assurance Emergency Response Organization Emergency Contingency Plan Training Division Emergency Response Guide DTG-007 05/29/03 10/15/02 04/30/03 04/02101 07/02/03 01/07/02 04/06/99 11/26/ol 11/11/02 03/27/00 05/01/03 I

2 Revision 2003-07 July 2003

  • NSD gylnN Duke Power Company (1)IDNo. RP/OIB/1000/017 0`41\\61N vI N PROCEDURE PROCESS RECORD Revision No. 008 ONLY

~-EPARATION (2)

Station OCONEE NUCLEAR STATION (3)

Procedure Title Spill Response (4)

Prepared By Ra Waterman (Signature) E9 G

A G

Date 06/03/03 (5)

Requires NSD 228 Applicability DeterminationY o Yes (New procedure or revision with major changes) 0 No (Revision with minor changes) o No (To incorporate pryiously aoove changes)

(6)

Reviewed By ___

_(QR)

Date Cross-Disciplinary Review By (QR)NAA&LDate 49 /

Reactivity Mgmt Review By (QR)NA Date Mgmnt Involvement Review By (Ops Supt) NA Date (7)

Additional Reviews Reviewed By Date Reviewed By Date (8)

Temporary Approval (f necessary)

By (OSMIQR)

Date By (QR)

Date (9)

Approved By

/

Date 7___

PERFORMANCE (Compare with control copy every 14 calendar days whie work is beingperformed.)

(10) Compared with Control Copy Date Compared with Control Copy Date Compared with Control C o

p y

Date (11) Date(s) Performed Work Order Number (WO#)

COMPLETION (12) Procedure Completion Verification:

o Unit 0 0 Unit 1 0 Unit 2 0 Unit 3 Procedure performed on what unit?

O Yes 0 NA Check lists and/or blanks initialed, signed, dated, or filled in NA, as appropriate?

o Yes 0 NA Required enclosures attached?

o Yes 0 NA Data sheets attached, completed, dated, and signed?

o Yes 0 NA Charts, graphs, etc. attached, dated, identified, and marked?

o Yes 0 NA Procedure requirements met?

Verified By Date Procedure Completion Approved Date (14) Remarks (Attach additionalpages)

Duke Power Company Station Name Spill Response Reference Use Procedure No.

RqOI/B/1000/017 Revision No.

008 Electronic Reference No.

OX002WPE

RP/01B/1000/017 Page 2 of 8 Spill Response NOTE:

This procedure is an Implementing Procedure to the Oconee Nuclear Site Emergency Plan and must be forwarded to Emergency Planning within seven (7) working days of approval.

1. Symptoms 1.1 An unplanned or uncontrolled release/spill of a chemical or substance in excess of normal drips and splatters has occurred or is occurring and has been reported to the Control Room.

1.1.1 A chemical or substance can include:

  • Products with an MSDS or Chemical Fact Sheet
  • Hazardous wastes
  • Radionuclide releases in excess of Tech Spec or 10CFR20 limits
  • Oil and petroleum products
  • Insulation containing, or potentially containing asbestos
  • Any of the above materials contained in or on plant equipment, systems or components such as RCW water, wet layup water, etc.
2. Immediate Actions NOTE:

All spills or releases reported to the control room should be documented on Enclosure 4.1, Spill Report Form.

Steps 2.1 through 2.4 needs to be addressed before allowing caller to hang up the phone.

2.1 Obtain the specifics of the spill/release from the person reporting the spill/release.

Name Date Phone Ext.

Spill Location Material Spilled Phone ext. or pager # that person can be reached at a later time (This number will be entered on Line 1 of Enclosure 4.1, Spill Report Form)

Other Pertinent Information

RP/O/B/1000/017 Page 3 of 8 2.2 IF the event involves a fire, explosion hazard, or a release of toxic gas such as ammonia, hydrazine or chlorine gas THEN relocate/evacuate all personnel from the spill area and downwind areas.

2.2.1 Ask the switchboard operator to contact the Environmental/Safety (EH&S) duty person for assistance in determining areas to be evacuated.

2.2.2 Notify OSM to consult RP/O/B/1000/001, (Emergency Classification) whenever flammable or toxic gasses are detected/reported within or have the potential for entering the site area boundary 2.3 IF the spill can be secured THEN perform the following:

instruct the caller to secure the area of the spill, warn others of any known danger, remain in a safe area and monitor the situation until emergency personnel arrive on the scene.

2.3.1 IF there is procedural guidance for handling a spill of this material and quantity THEN instruct the caller to follow the procedure if it can be done safely.

2.4 IF the release is still in progress, continues to spread, or if there is no procedural guidance for handling releases of this material THEN dispatch a Fire Brigade member to assess the event, warn others of any known danger remain in a safe area and monitor the situation until emergency personnel arrive on the scene.

RP/O/B/1000/017 Page 4 of 8

_ 2.4.1 IF the Fire Brigade requests site HAZMAT Team response or the event is a petroleum product that has reached water or is likely to reach water through floor drains, sumps or yard drains.

THEN page out the ONS HAZMAT Team, by having the switchboard operator activate the HAZMAT Team pagers.

2.4.1.1 Use plant P/A system and make following announcement twice (2):

If a drill:

This is a drill, This is a drill, All HAZMAT Team personnel please respond to PAP staging area. All HAZMAT Team personnel please respond to PAP for staging area.

If actual event:

May I have your attention please, May I have your attention please, All HAZMAT team members please respond to PAP staging area. All HAZMAT team members please respond to PAP staging area.

2.4.1.2 Call the Security PAP and request them to post the following information in the Administrative Building hallway outside the PAP Incident Location Chemicals involved, if known Any other pertinent information that may be available for the site HAZMAT Team responders NOTE:

The request for offsite HAZMAT team assistance should be made simultaneous with the request for fire department assistance. Offsite HAZMAT teams will not respond unless the fire department is also responding.

Request for assistance from the Oconee County HAZMAT Team must be made through the local Oconee County fire department.

2.5 IF conditions warrant assistance from the local county HAZMAT teams as determined by the Fire Brigade Leader or the HAZMAT Team Leader THEN contact the appropriate County Rural Fire Department by calling the number listed in Section 8 of the Emergency Telephone Directory and request assistance of the County HAZMAT Team and local fire department.

  • If the TSC is operational, the TSC Offsite Communicator can make this request.

RP/OBI1000o/017 Page 5 of 8 2.6

_F the HAZMAT event is located at Keowee Hydro THEN request assistance from the Pickens County HAZMAT Team through the local Pickens County fire department.

2.6.1 If the TSC is operational, contact the TSC Offsite Communicator and initiate the turnover of remaining procedure requirements to them.

2.6.1.1 Turnover should include information received from the caller, Actions taken Response of the Fire Brigade/IHAZMAT Team Other known information 2.7 Complete steps 1-10 of Enclosure 4.1, (Spill Report Form) for all spills reported to the Control Room.

2.8 Immediately contact the EH&S Duty Person for all spills reported to the Control Room.

During normal day shift hours (0700-1730, Monday - Thursday) contact EH&S at ext.

4090.

During back shift, weekends, page EH&S Duty person.

_ 2.8.1 Provide the information from lines 2 through 10 on the Spill Report Form to the Duty Person and any other known details of the release.

NOTE:

The Duty Person may have to research regulations or consult with others to determine if the release is reportable. During this time, completion of this procedure will be suspended.

Request that the Duty Person inform you if it appears that the time required to make-a determination of reportability will be longer than originally expected.

2.9 Ask the Duty Person if the release is reportable.

2.9.1 IF the release is not reportable THEN perform the following:

Go to the bottom of the Spill Report Form.

Mark a line through "Approved for Release" and initial.

Sign in the "Operations Shift Manager/Emergency Coordinator" space.

Go to Section 3.0, Subsequent Actions, of this procedure.

RP10/B/1000/017 Page 6 of 8 2.10

]F the release is reportable THEN perform the following:

Request from the Duty Person the information that is required to complete line numbers 11 through 13 on the Spill Report Form.

Have the Operations Shift Manager or Emergency Coordinator sign the "Approved For Release" space at the bottom of the form.

NOTE:

Reportable releases require notification of off-site emergency and regulatory agencies. The telephone notification to the Nuclear Regulatory Commission in Step 2.12 must be made within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> after Step 2.12 has begun.

2.11 Fax the approved form to the Oconee County Emergency Preparedness Agency at the fax number listed in the Emergency Telephone Directory, Section 4.

2.12 Fax the approved form to the Oconee County Law Enforcement Center to the fax number listed in Section 5 of the Emergency Telephone Directory.

2.12.1 Contact Oconee County Law Enforcement Center at the Selective Signaling number in the Emergency Telephone Directory, Section 5.

2.12.1.1 Write the contact information for the Oconee County Law Enforcement Center in the appropriate space in the top section of.1, (Spill Report Form).

2.13 IF the release is to Keowee River THEN fax the form to the Pickens County Emergency Preparedness Agency at the fax terminal number listed in the Emergency Telephone Directory, Section 4.

2.13.1 Contact the Pickens County Law Enforcement Center at the Selective Signaling number in the Emergency Telephone Directory, Section 5 after Oconee County notification is made.

2.13.1.1 Write the contact information for the Pickens County Law Enforcement Center in the appropriate space in the top section of.1, (Spill Report Form).

RP/0IB/1000/017 Page 7 of 8 NOTE:

The 24-hour contact number for the S.C. Bureau of Solid and Hazardous Waste Management (13SHWM) is State Emergency Response Commission. It may be necessary to wait for a return call from the BSHWM duty person. The State Emergency Response Commission's normal working hours are 0830 - 1700, after this time you will reach a recording.

2.14 Contact S.C. Bureau of Solid and Hazardous Waste Management (BSHWM) at 1-803-253-6488 or 1-888-481-0125.

2.14.1 Write the contact information for the S.C. Bureau of Solid and Hazardous Waste Management in the appropriate spaces in the top section of Enclosure 4.1, (Spill Report Form).

2.14.2 Provide the information from lines 2 through 13 on Enclosure 4.1, (Spill Response Form) to the BSHWM duty person.

2.14.3 Obtain the South Carolina Department of Health and Environmental Control file number from the BSHWM duty person and enter that file number in the appropriate space at the top of the Spill Report form.

2.15 Contact National Response Center at 1-800-424-8802.

2.15.1 Write the contact information for the National Response Center in the 'National Response Center Contact" space in the top section of Enclosure 4.1, (Spill Report Form).

2.15.2 Provide the information from lines 2 through 13 on Enclosure 4.1, (Spill Report Form) to the National Response Center duty person.

2.15.3 Obtain the National Response Center file number and enter the number in the "National Response Center File Number" space at the top of Enclosure 4.1, (Spill Report Form).

2.16 Make a Red Phone call to the Nuclear Regulatory Commission.

2.16.1 Provide all the information from Enclosure 4.1, (Spill Report Form) including the offsite agencies that were notified.

2.17 Notify the Regulatory Compliance Duty Person that an NRC four hour Red Phone call has been made.

2.17.1 Ask the Regulatory Compliance Duty Person to notify the NRC Resident Inspector on duty that a four hour Red Phone call has been made.

2.18 Notify the World of Energy Duty Person of any releases reported to offsite agencies.

2.19 Go to Section 3. Subsequent Actions, of this procedure.

RPIO/B/1ooo/017 Page 8 of 8

3. Subsequent Actions 3.1 Telephone the person who reported the spill/release (from Line 1 of the yellow sheet/Spill Report form) for any information regarding the department/revision that is responsible for the spill.

3.1.1 Verify that this person can be reached at a later date at the telephone number listed on Line 1 of the Spill Report form.

3.1.2 Advise the spill reporter that it is no longer necessary for him/her to remain at the phone.

3.2 Initiate the Problem Investigation Process (PIP).

3.3 Record the information from lines 3-10 of the Spill Report form in the appropriate section of the Problem Identification portion of the PIP.

3.4 Write the PIP number in the appropriate space at the top of the Spill Report form.

3.5 Send the original approved Spill Report form to EH&S (ON03EM) along with any additional notes or information that will assist in the problem investigation.

4. Enclosures 4.1 Spill Report Form

Spill Report RP/OIB/1000/017.1 Page 1 of 1 PIP No.

SCDHEC File No.

National Response Center File No._

Oconee Count Law Enforcement Center Telephone Date Time Contact Pickens County Law Enforcement Center Telephone Date Time Contact I-m-481-0125 1-803-253-6488 State Emergency Response Committee Telephone Date Tume (SCBSHWM) Contact 1-800-424-8802 National Response Center Contact Telephone Date Time Name of Person Reporting Release Telephone Date Time to 491 1)

2. This is at Duke Power Comnany's Oconee Nuclear Site. Seneca. SC The telephone number is (8)885-3312
3. A release of occurred at on (Name of Product)

'iune)

(Date)

4. An estimated quantity of of the substance was released for a duration of (bsJgal.)

(HoursMinutes)

The release [ is. is not] continuing. (Crde one)

5. The material was released to the and covers an area of (Air/Water/Soil)

(Length and Width)

6. The source of the release was located at or from (Dnim, Tank, Piping. etc.)

(Unit. Building. Vehicle #, System. etc.)

7. It was attributed to (Cause of incident)
8. Corrective action being taken or planned:
9. There were injuries and fatalities related to the release.

(numbers)

(numbers)

10. Extent of property damage was
11. Ust the hazardous substances in the material and their respective statutory listing:

HAZARDOUS SUBSTANCE CERCLA OR EHS LIST

12. Health risks associated with the release:
13. Recommendations for the public and the emergency response personnel:

Environmental Health & Safety (EH&S)

Afl~flnmrh fnew f~lC A

sCl.

Telephone Date Time Operations Shift Manager/Emergency Coordinator Date Tune