ML031820448

From kanterella
Jump to navigation Jump to search
Draft Information Input Faxed on June 3, 2003 (50-368) Containment Spray System Surveillance License Amendment
ML031820448
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 06/03/2003
From: Boyd D
Entergy Operations
To: Alexion T
Office of Nuclear Reactor Regulation
Gramm R, NRR/DLPM,415-1302
Shared Package
ML031830124 List:
References
Download: ML031820448 (3)


Text

ThomasAlexion - RE:- CONTAINMENT SPRAY SYSTEM SURVEILLANCES LICENSE AMENDMENT RFEQUEST Page 1 From: 'BOYD, DENNIS W <DBOYD@entergy.com>

To: Thomas Alexion'" <TWA nrc.gov>

Date: 6/3/03 3:40PM

Subject:

RE: CONTAINMENT SPRAY SYSTEM SURVEILLANCES LICENSE AMENDMENT REQUEST Tom, I recommend a phone call so we can discuss Sarah's question. We need some clarification.

This proposed change is consistent with the change we have already made to other ANO-2 technical specifications, e.g., ECCS (SR 4.5.2.b), Emergency Feedwater (SR 4.7.1.2), Service Water (SR 4.7.3.1.a), etc. These specs already contain the proposed wording and do not require short-interval verification of valves that are locked, sealed or otherwise secured in position. The SR is intended to ensure verification of valve positions in the main flow path that could be inadvertently repositioned. It is not likely that inadvertent repositioning could occur with regard to valves that are locked, sealed, or otherwise secured. The proposed wording of the change regarding verification of valves in the flow path of the containment spray system is identical to that approved by the NRC in Technical Specification Task Force (TSTF) 45 and, subsequently, NUREG-1432.

A system such as the containment spray system communicates directly with the containment atmosphere/sump; therefore, it contains valves that are required to be secured in the OPEN position to assure flow is directed to the containment atmosphere/sump. The valves secured in the CLOSED position normally do not communicate with the RCS or the containment atmosphere, but prevent flow from being diverted away (i.e., flowing through an alternate flow path) from the main system flow path.

Such alternate paths typically contain dual isolation valves both secured in the closed position. In the case of the LPSI system alternate flow path, a single isolation valve is provided. This is acceptable because the LPSI system receives an ESF actuation which will result in flow into the RCS/containment sump. Both of these options are designed to decrease the likelihood that required system flow could be diverted from the main flow path. Therefore, it is not necessary to evaluate such al Itemate flow paths or the inventory that may be lost through them. It appears at first glance that the reviewer's question is beyond our design basis.

If you prefer to wait to have a phone call until you receive input from your other reviewers, that is fine with us.

Dennis


Original Message-From: Thomas Alexion [maifto:TWA@nrc.gov]

Sent: Friday, May 30, 2003 9:40 AM To: BOYD, DENNIS W

Subject:

CONTAINMENT SPRAY SYSTEM SURVEILLANCES LICENSE AMENDMENT REQUEST

iThoras Aexion - RE: CONTAINMENT SPRAY SYSTEM SURVEILLANCES LICENSE AMENDMENT REQUEST' ,Pag-e Dennis, See the attached request for additional information.

Tom

10W1Nb0WS\TEMP\GW100001.TMP Paqe 1111 Pacie i C:\WINDOWS\TEMP\GWIOOOO1 .TMP Mail Envelope Properties (3EDCF987.C5E :10 : 3166)

Subject:

RE: CONTAINMENT SPRAY SYSTEM SURVEILLANCES LICENSE AMENDMENT REQUEST Creation Date: 6/3/03 3:39PM From: "BOYD, DENNIS W" <DBOYD~entergy.corn>

Created By: DBOYD~entergy.corn Recipients nrc.gov owf4_-po.OWFNDO TWA (Thomas Alexion)

Post Office Route owf4...po.OWFNDO nrc.gov Files Size Date & Time MESSAGE 2540 06/03/03 03:39PM Part.001 5751 Mime.822 9714 Options Expiration Date: None Priority: Standard Reply Requested: No Return Notification: None Concealed

Subject:

No Security: Standard