Hydrogen Control Calculations for the Sequoyah Plant Reference and Uncertainty Calculations Final Letter Report March 2003 Prepared By Jack Tills, JTA, Inc.
Sandia Park, NM For Organization 6415 Sandia National Laboratories Albuquerque, NM Task No. 1: PO# 28839
Hydrogen Control Calculations for the Sequoyah Plant Reference and Uncertainty Calculations 1
Introduction The Sequoyah containment is equipped with a system of igniters designed to ensure controlled burning of hydrogen in the unlikely event that excessive quantities of hydrogen are generated and released to the containment during a postulated degraded core accident. Power is supplied directly to the igniters at 120VAC.
During station blackout accident scenarios, both offsite and backup onsite AC power to the igniters will be interrupted; therefore, the igniters will not be available as a hydrogen control system. The series of calculations discussed in this report addresses hydrogen distribution and burn (deflagration) behavior in the Sequoyah containment should supplemental onsite power be provided to igniters and/or air return fans during a station blackout accident.1 The calculations have been performed (using MELCOR) by de-coupling the MELCOR reactor cooling system (RCS) models from the containment model, thereby analyzing the containment response as a standalone problem. This de-coupling procedure has the advantage of unburdening the containment analysis of the time consuming calculations performed in the CORE package of an otherwise combined RCS and containment response calculation. Because feedback from the containment system to the RCS is weak, this type of de-coupling can be accomplished without significantly affecting the source terms (water, steam, and hydrogen) to the containment or the subsequent containment response.2 Within MELCORs control volume and flow path packages, I/O features are provided to allow the type of de-coupling discussed here.
The specific accident event selected for analysis is a short-term station blackout with pump seal leakage (250 gpm leakage), STSBO-L. From a series of MELCOR source-term uncertainty calculations, reference and selected uncertainty runs have been chosen for use in the containment analysis study. The selection criteria for the reference and uncertainty source-terms (water, steam, and hydrogen injections to the containment) used in this study are discussed later. Issues of hydrogen control scenarios explored in the report are:
- Delayed deflagration without power to either igniters or fans
- Controlled burning (deflagration) with power to igniters
- Controlled burning (deflagration) with power to both igniters and fans.
1 The calculations describe controlled or ignited burns characterized as deflagrations. Detonations or deflagrations to detonation transitions (DDT) are not specifically addressed in this report except to note in general terms the extended time periods when there may exist a potential for large-scale detonations or DDT behavior.
2 A fully coupled calculation is required to account for the atmospheric heating resulting from small releases of radioactive nuclides. The decay heating from nuclides in the containment however is a second order effect as noted in fully coupled calculations discussed in Appendix A.
1
The discussions in the following sections focus on hydrogen control conditions with uncertainties investigated for burn parameters and source terms. Other uncertainties associated with code input have also been addressed during the course of this effort: ice bed nodalization and bypass leakage flow modeling. Ice bed nodalization, being an issue in previous ice-condenser plant analyses, is discussed here in the context of MELCOR ice bed nodalization sensitivity calculations which are reported in some detail in Appendix B. In the case of the bypass leakage flow modeling,3 it has been observed in calculations that changes in flow area (0.03 to 0.29 m2) and elevation (10 to 20 m) produce no significant change in containment hydrogen concentrations, and therefore these calculations are not discussed further. Additionally, in earlier addendums to previous draft reports, fully-coupled RCS/containment MELCOR calculations with power to igniters were conducted to investigate late time (post vessel failure) hydrogen control behavior with core/concrete interactions (CCI). These calculations, conducted with earlier MELCOR derived source terms,4 indicated that oxygen depletion prior to vessel failure substantially reduced the risk of late time overpressurization due to deflagrations or potential detonations. This conclusion is not expected to change with the more recent source terms generated by the current MELCOR Sequoyah plant models. Therefore, these calculations were not repeated for this report. The results of the earlier, fully coupled RCS/containment calculations are however included as Appendix A. Finally, the possibility of diffusion flames at the top of the ice condenser was considered in the preparation of this report, with attempts to include this type of burn scenario in the study.
However, the analysis (diffusion flame without DCH) could not be completed without code modification, and therefore was excluded from the study.
In Section 2, the MELCOR containment model is described along with the various hydrogen source terms obtained from MELCOR station blackout calculations. The reference and representative uncertainty source term inputs are also discussed in this section. Hydrogen control in the containment is discussed in Section 3 for both reference and uncertainty source terms. Section 4 presents the results of an uncertainty/sensitivity analysis for burn parameters (Monte Carlo uncertainty study for the standalone containment analysis). Section 5 summarizes the study results.
2 MELCOR Sequoyah Containment Model (s)
Shown in Figure 1 is a drawing of the Sequoyah containment indicating boundaries of three major containment regions: lower containment, ice-condenser, and upper containment. The ice bed is isolated from the lower and upper containment by lower plenum, intermediate, and upper plenum doors that remain shut during normal operation.
During postulated accident events leading to RCS injections of liquid water and steam to the lower containment, these doors can open as a result of the pressure differentials 3 Bypass flow refers to uncertain leakages assumed to occur in the vicinity of the operation deck dividing the lower and upper containment. These flows are separate from those flows associated with open refueling drains.
4 R.O. Gauntt and L. L. Humphries, Hydrogen Source Terms for Station Blackout Accidents in Sequoyah and Grand Gulf Estimates Using MELCOR 1.8.5, Draft Sandia Report, July 26, 2001.
2
across the doors. Steam flowing into the ice condenser is condensed onto ice baskets holding flakes of ice. The ice bed is therefore a region of low steam concentration, and a probable location for high concentrations of released hydrogen in the case of degraded core accidents. There are no igniters located in the ice bed, and therefore any burns in this region must be initiated as a result of flame propagation.
2.1 Nodalization Figure 2 is a sketch of a containment model indicating the various sub-compartments that are modeled by the MELCOR standalone containment model, referred to here as the 26-cell model. Table 1 lists the compartment descriptions for each cell in the model. The 26-cell containment model is derived directly from a CONTAIN containment model discussed in NUREG 5586 - a copy of the MELCOR standalone containment input files (MELGEN/MELCOR files) for the case with power to igniters is included as Appendix C. One important feature of the model is the nodalization of the ice bed, Figure 3. The ice bed is represented by four azimuthally arranged cells (18-21) that extend from the bottom to top of the ice bed. Vertical density profiles within the ice bed obviously cannot be calculated with this model. However, upper and lower circulation paths within the ice bed are provided to allow circulation caused by variations in the static heads between cells. The rationale for using single cells to represent vertical portions of the ice bed is driven by a number of reasons, some physically based and others based on practical and model consistency arguments. Additionally, calculations were performed that included axial subdivision of the ice bed control volumes to confirm the appropriateness of the simpler nodalization, as will be demonstrated in subsequent sections, and in Appendix B.
From a physical standpoint, we contend that significant vertical compositional and density differences within the ice bed, during a degraded core accident such as the STSBO-L sequence, are not to be expected. This assertion is based mainly on mixing processes generated as the result of 1) the relatively high rates of steam and hydrogen injected into the ice condenser during the scenario, 2) the likely asymmetrical character of those injections, and 3) the turbulence created during deflagrations. Additionally, the entrance location for ice bed gas mixture injection is in a region, under stagnant conditions, that is most likely to form a stratified layer (gas mixtures remaining in the ice bed will become heavier as the mixture is cooled and depleted of steam, settling to the lower regions of the ice bed). Injections into this region will most readily disrupt the stratifying layer. To investigate the propensity for circulation and uniform mixing, a coarse one-dimensional, vertically stacked ice bed nodalization scheme and a detailed vertical/horizontal nodalization scheme were included in the study. The purpose for using the one-dimensional scheme was to show resulting ice bed hydrogen concentrations for a scheme that does not allow circulation within the ice bed. The one-dimensional scheme has a history of being employed in early ice-condenser plant analyses and therefore was included for completeness.5,6 A more detailed nodalization scheme than 5 Camp, A. L., et al., MARCH-HECTR Analysis of Selected Accidents in an Ice-condenser containment, NUREG/CR-3912, SAND83-0501, Sandia National Laboratories, December 1984.
3
the 26-cell model, consisting of four columns and four rows of interconnected ice bed cells (38-cell model) was investigated to show that gross circulations within the ice bed do indeed occur during the accident sequence resulting in mixing, and that models based on single, vertical cells azimuthally configured, as in the 26-cell model, therefore represent a reasonable nodalization for the study. Of course, small local or secondary circulation behavior cannot be addressed with a lumped-parameter code, such as MELCOR; however, small regions with variable vertical composition and density variations are considered of minor significance for the purpose of this study, which focuses on overpressurization resulting from regional or global deflagrations. A discussion of the nodalization sensitivity study is included here as Appendix B.
For the practical aspects of ice bed modeling, additional vertical segmentation of the ice bed, especially for cases with fans operating significantly slows the calculations, inhibiting our ability to perform statistical (Monte Carlo) uncertainty/sensitivity studies for burn parameters. From a model consistency standpoint, vertical burn propagation using single, vertical cells in the ice bed represents a consistent treatment for flame propagation correlation and usage. The correlations for flame speeds are derived only for single compartment burns. Propagation of burns in relatively open regions (which may also have composition and density gradients) using multiple-cells is not validated for a lumped-parameter code like MELCOR. A single, vertical cell model represents therefore a relatively consistent treatment for flame propagation based on current code correlations.
Within the other regions of the containment (upper and lower containment), the containment model divides into specific confinement regions, generally isolated by well-defined flow paths. The vertical segmentation in the upper containment with the 26-cell model allows for the possibility of upper containment stratification of air and hydrogen in the dome. A tendency for some stratification in this regard is noted in calculations without the fans operating. Within the lower containment, additional compartments are modeled to allow simulation of dead-ended regions. These regions can be inerted during significant periods due to high concentration of steam that builds up during the early portion of an accident, prior to hydrogen release.
2.2 Source terms Hydrogen control calculations for the Sequoyah plant were first reported in an April 2002 draft report. In that report, the source term for the containment was documented by SNL in a report Hydrogen Source Terms for Station Blackout Accidents in Sequoyah and Grand Gulf Estimated Using MELCOR 1.8.5, dated July 26, 2001. Since that time,, an updated set of hydrogen source term calculations have been completed.7 The purpose of the more recent calculations (40 runs in all) was to estimate the uncertainty in hydrogen 6 S. Dingman, et al., HECTR Version 1.5 Users Manual, NUREG/CR-4507, SAND86-0101, Sandia National Laboratories, April 1986.
7 See R. Gauntt et al.,An Uncertainty Analysis of the Hydrogen Source Term for a Station Blackout Accident in Sequoyah Using MELCOR 1.8.5, Sandia National Laboratories Letter Report, 30 September, 2002.
4
source terms though variations in reactor core and RCS model input parameters. The calculations were conducted for a STSBO-L sequence using a new 5-Ring model of the Sequoyah core (original calculations made with 3-Ring core model) together with other modifications made to the RCS coolant loops.
Shown in Figures 4 and 5 are the in-vessel hydrogen generation profiles for the 40 MELCOR runs completed by SNL. The hydrogen generation ranges from approximately 430 to 600 kg at the time of vessel failure. For the purpose of determining the effect of source term variation on hydrogen control, three representative source term runs were selected for the standalone containment analyses. These runs are summarized in Table 2.
The selected runs provide a reasonable range of the high and low hydrogen source terms (run 21 vs. 35) and in addition include the variability of hot leg failure/no failure (run 21 vs. 32).
Hydrogen, water, and steam can enter the lower containment (prior to vessel failure) from primary system leaks (pump seals), valve openings (PORVs, etc.), and coolant line breaks (hot leg and/or surgeline breaks).8 Shown in Figure 6 are the approximate locations for these sources. The mass rate and integral amount of hydrogen injected into the containment for MELCOR run 21 are shown in Figure 7 and 8 for the pump seals and hot leg break, respectively. For run 21, hydrogen is not released from the PORVs since these injections (both water and steam), as shown in Figure 9, occur prior to the start of hydrogen generation, shown in Figure 10. Since the surgeline does not fail in run 21, there are no hydrogen injections from the surgeline. Water and steam injections from the pump seals and steam injection from the hot leg break are shown in Figures 11 - 13.
Total hydrogen generated in-vessel for run 21, Figure 10, shows that there are essentially two phases to the generation and similarly the injection process. The first phase, responsible for approximately 515 kg or 90% of the total hydrogen release, is from the pump seal leakage over about a 1.5-hour period beginning at 3.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> into the accident.
When the hot leg of the RCS fails due to creep rupture at ~ 5.4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, an additional ~55 kg of hydrogen is released along with a surge of steam which rapidly pressurizes the containment. Following the hot leg rupture, the steam sources to the containment are relatively minor and the containment depressurizes somewhat as it cools before lower head failure occurs at approximately 6.4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> into the accident.
The uncertainty range for hydrogen source terms is represented by MELCOR runs 21, 32 and 35 as indicated in Table 2. The in-vessel hydrogen generation rate and integral amount for runs 32 and 35 are shown in Figures 14 and 15. These sources can be compared to those in Figure 10 for run 21, representing a case with both high mass rate and cumulative injection. The hydrogen injection rates for run 32 (pump seal) and 35 (pump seal and hot leg) are shown in Figures 16 - 18.
8 Nitrogen releases to the containment from the accumulators tanks does not occur for this scenario until vessel failure.
5
3 Hydrogen Control Without controlled hydrogen burning there is likelihood that hydrogen will accumulate in the containment and ignite at a time when a global deflagration will be severe enough to threaten the integrity of the containment. For example, shown in Figure 19 is a case where a global burn is delayed until ignited by hot ejected core material at the time of vessel failure. Random autoignition is to be expected even without hot ejected debris owing to static discharges associated with flowing gases and dust. For the Sequoyah containment, the pressure corresponding to an estimated 10% failure probability is 525 kPa (absolute).9 The risk of over-pressurizing the containment from a delayed global deflagration is clearly apparent without hydrogen control. However, there are also other concerns. Local pockets of hydrogen having high concentrations could ignite to produce an accelerated flame, deflagration to detonation transition (DDT), or in some cases a detonation directly. In the following analyses we assess the hydrogen distributions within the containment for potential combustion events. The cases investigated are those having 1) no power to igniters, 2) power to igniters only, and 3) power to both igniters and fans (single train). The hydrogen source term calculated in MELCOR run 21, representing a high injection case, is selected as a reference case. Source terms for MELCOR runs 32 and 35 are used to indicate the variability in hydrogen behavior as a result of source term uncertainty.
Shown in Figures 20 - 22 are containment pressures calculated for the cases without igniters, with igniters, and with igniters and fans (single train). For the ignition of hydrogen, the combustion and propagation limits listed in Table 3 are used. Locations for the igniters are shown in Table 4. Figures 23 - 25 show the ice-bed hydrogen concentrations for run 21 for the case without igniters, with igniters, and with igniters and fans, respectively. The ice-bed hydrogen concentrations for runs 32 and 35 are presented in Figures 26 - 28 and Figures 29 - 31.
The upper containment (compartment #24) hydrogen concentrations for the MELCOR runs 21, 32, and 35 are shown in Figures 32, 33, and 34, respectively, for each case with, without igniters and with igniters and fans.
A comparison of hydrogen burn totals by region for the various MELCOR runs (source terms) with igniters and with igniters and fans is presented in Tables 5a, 5b, and 5c. The total hydrogen burn percentage (hydrogen burn / hydrogen injected X 100) for various source terms show minor sensitivity with percentages ranging from 68 to 74 %. Burn percentages by compartment indicate the shift towards more burning in regions with igniters when the fans operate as compared to the cases with power to igniters only. This means that burns in the ice bed and lower plenum due to flame propagation are minimized when the fans are active. For the upper containment, which is an important control region, the distinction between power to igniters and power to both igniters and fans is small.
9 See Table B.4 in NUREG 6247 for ice condenser containment fragility measures.
6
It is noted in these calculations for the various source terms that a substantial amount of hydrogen is consumed in the lower containment (58-68%) even when fans are not activated. There has been speculation that the lower containment will be steam inerted during the injection, or will be depleted of oxygen as a result of expulsion of air from the lower containment during the injection event, thereby limiting lower compartment burning. Additionally, burning in the lower compartment could consume what small amount of oxygen existed and therefore preclude further burning. As indicated in Figure 35, the lower containment is not inerted by steam during a critical burn period between 3.5 and 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />. Furthermore, oxygen in the lower compartment is not limited since there are return air flows from 1) the refueling drains and 2) partially open lower plenum doors (dynamic action and leakage). An important source of the return air to the lower compartment is from the refueling drains. This behavior is shown in Figure 36, where the oxygen flow through the refueling drains to the lower containment is shown (negative flows indicate upper containment to lower containment oxygen transfer). The refueling drains remain open during the early portion of the accident (prior to vessel failure) since containment sprays are inactive for the SBO event and the lower compartment water level is too low to flood the drains.10 Later in the accident, the lower containment water will flood the drains, however, by this time a significant amount of in-vessel generated hydrogen will have been burned.
Shown in Tables 6a and 6b are the hydrogen burn amounts by compartment for two cases (based on the reference calculation) where the refueling drains are assumed closed and in addition the lower plenum door leakages are minimized. A comparison of the results from Tables 5a and 6a indicate that the refueling drain flows affect lower compartment burns significantly - changing the amount burned in the lower containment from 229 to 135 kg, and increasing the amount of hydrogen consumed in the ice bed from 111 to 181 kg. The addition of fans, even with the refueling drains closed, returns the compartment burn percentages to approximately the same percentages when the refueling drains are open. An additional reduction in lower compartment burning occurs when both the refueling drains are closed and the lower plenum door leakage is minimized, Table 6b.
However, the amount is not as significant as when closing just the refueling drain pathways. In each case reported for drains or leakage, the addition of fans does substantially reduce the amount of burning in the ice bed, returning the majority of the burns to regions where igniters are located (upper plenum, lower and upper compartment).
Although fan operation produces more burning in regions of igniters, which in and of itself may be viewed as advantageous, fan operation also results in more rapid depletion of ice prior a period of overpressurization caused by late time CCI. Since this occurrence (rapid ice depletion) may result in a somewhat earlier threat to the containment integrity due to overpressurization, the degree of ice melt for various scenarios is reported in Table 7 for comparisons. Fan operation is seen to increase ice depletion by approximate 15%
(i.e. an increase from ~ 45 to 65 % depletion). However, source term uncertainty also 10 Lower compartment water flooding profiles are modeled in the Sequoyah plant using flooding estimates referenced in Pilch M. M., et al., Assessment of the DCH Issue for Plants with Ice Condenser Containments, NUREG/CR-6427, SAND99-2553, Sandia National Laboratories, September 1999.
7
causes a substantial variation of ~10% depletion (e.g., 38 to 47% depletion).
Interestingly, the ice depletion percentage with fans for one case (run 32) is nearly the same as other cases (runs 21 and 35) without fans. Ice depletion variability, in terms of depletion percentages, may be as important for the source term uncertainties as for an option of power/no power to fans.
4 Burn Uncertainty/Sensitivity Analysis The burn parameter uncertainty/sensitivity analysis is performed for the reference containment calculation with power to the igniters only. The methodology used for the uncertainty analysis/sensitivity analysis is based on a Monte Carlo (direct statistical method) using subjective probability density functions to describe the burn parameter uncertainties. The method is described in some detail by the International Uncertainty Methods Study Group (labeled the GRS method).11 Table 8 gives the deflagration parameters ranges selected for the analysis - the default parameters (see Table 3) are also indicated within the parenthesizes. It was assumed that the subjective probability function profiles for the parameter distributions are uniform.
The output indicator of interest for the study is the maximum hydrogen concentration during or at the end of each significant phase of the hydrogen injection event. For this case (MELCOR run 21) the phases are 1) the period of significant pump seal release (3.5
- 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />) and at the time just before vessel failure ( ~ 6.4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />). The maximum hydrogen concentrations for each time period obtained using the reference case parameters are shown in Table 9. Shown in Table 10 are the uncertainty intervals, represented as the 95% probable and 95% confidence level, for each time interval. To obtain these results 100 calculations were run using random vector inputs for the deflagration parameters (sampling from a uniform probability distribution function). The largest uncertainty range in hydrogen concentration variation (~ 5%) is for the ice bed, with a maximum concentration of 14.7% indicated. As stated earlier in 2.1, small local circulation and concentration details cannot be modeled with a lumped-parameter control volume code such as MELCOR, suggesting that other higher fidelity models might calculate pockets of higher concentration.
For the sensitivity analysis, Spearman rank coefficients were determined for each burn parameter based on the results of the uncertainty study that included 100 output vectors.
The Spearman rank coefficients can vary from -1 to 1. A negative coefficient indicates that an increase in the burn parameter value will result in a decrease in the output variable. Conversely, a positive coefficient indicates that an increase in the burn parameter results in an increase in the output variable. A 95% confidence level that there exists a correlation requires that the absolute value for the rank should be greater than approximately 0.2 (100 random trials). Tables 11 and 12 present the rank coefficients for each injection or analysis period. Larger absolute values of the rank coefficients indicate a stronger correlation. For example, an increase in the hydrogen concentration limit for ignition results in an increase in the maximum hydrogen concentration in the ice bed during the 3.5 - 5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> period. The most obvious correlations are for 1) the hydrogen 11 Report on the Uncertainty Methods Study, NEA/CSNI/R(97)35/Volume 1, June, 1998.
8
concentration limit for ignition (all regions), 2) the maximum steam concentration for ignition (ice bed and upper containment), and 3) the hydrogen concentration limit for downward propagation (ice bed). Phenomena with no apparent correlation between hydrogen concentration uncertainties and burn parameter are 1) hydrogen concentration for upward propagation (lower compartment and ice bed) and 2) hydrogen concentration for horizontal propagation (lower compartment and ice bed).
5 Summary A short-term station blackout with pump seal leakage scenario (STSBO-L) has been analyzed using the MELCOR code to determine potentially severe containment loads that may be produced with and without active hydrogen control. The analysis, conducted for the period of time up to and including vessel failure, showed that active hydrogen control using dc igniters can be effective in controlling challenges to the containment when compared to the option of no active control. The standalone containment analysis used a detailed description of the containment (26-cell model) and source terms for water, steam, and hydrogen to the containment. The source terms were generated by separate MELCOR code calculations reported elsewhere (prior reference 7). Three scenarios were selected from a MELCOR uncertainty analysis of hydrogen sources terms to obtain a representative range of high and low hydrogen injections (570 to 430 kg) to the containment.
Hydrogen control through the supply of supplemental onsite power to igniters was studied, as well as the case for power to both igniters and fans (single train). For scenarios with power to igniters only, it was shown that 1) global hydrogen concentrations (especially in the upper containment) can be significantly reduced from the levels that would be attained without any control, and the potential for a delayed global burn minimized, and 2) local hydrogen build-up in the ice bed can also be significantly reduced such that the time period where locally higher hydrogen concentrations (9-15%) exists can be minimized. It should be noted that local concentrations of hydrogen within the ice bed are only estimates due to the lumped-parameter control volume nature of the MELCOR code, and therefore these calculations do not confirm that there is a zero probability of events occurring such as DDT or detonations; rather, they show that hydrogen concentrations in the ice bed are in a relatively low range (both in terms of time duration and absolute value) such that the events are very unlikely. Should however power not be supplied to igniters, the likelihood of a detonation is significantly increased not only in the ice bed, but more importantly in the upper containment region.
The range of source term uncertainties investigated indicated only minor variations in hydrogen concentrations or compartment burn percentages (i.e., containment burn profiles) when hydrogen control is active (power to igniters or to igniters and fans).
These analyses have also explored sensitivity to nodalization. These sensitivity studies with 26-cell and 38-cell models indicate some residual uncertainty with respect to peak hydrogen concentrations in the ice beds remains that likely cannot be reduced by additional MELCOR calculations with finer nodalization. Predicted peak concentrations 9
10 ranged from ~8% for the 26-cell model to ~12% for the 38-cell model. We conclude from this that peak concentrations are likely to be in the low range and under 15%. If greater spatial resolution is needed than inherent in these analyses, then use of more sophisticated codes and confirmatory experimental studies might be required.
Fan operation, by mixing the gases in the containment, is shown to 1) reduce somewhat the local build-up of hydrogen, 2) aid in the prevention of steam inerting, and 3) help supply oxygen to regions with high burn rates (e.g. the lower containment). In general, the fans enable more burning in regions that have igniters in place (upper plenum and lower containment). The use of fans results in less dependency on flame propagation into regions like the ice bed. Although the fans help direct most burns to igniter locations, the total amount of hydrogen consumed (at time of vessel failure) is not substantially affected by having fans powered. Additionally, with igniters powered, the global hydrogen concentration in the large upper containment region is essentially unchanged with and without fans on.
Burns in the lower containment regions are observed to be responsible for the majority of hydrogen depletion. Such burn behavior is not substantially varied even if fans are powered. Circulation pathways represented by the refueling drains distribute a significant amount of oxygen to the lower compartment even without fan operation. This circulation enables a substantial amount of lower compartment burning to occur.
An uncertainty/sensitivity analysis (direct statistical analysis) of hydrogen burn parameters (e.g., ignition and propagation limits) was completed for a reference scenario (high hydrogen source term) with power to igniters only. Hydrogen concentration uncertainty ranges for the lower containment, ice bed and upper containment were determined for the period of substantial hydrogen injection and the time just prior to vessel failure. The largest uncertainty range (~5% variation) occurred for the ice bed both during the pump seal injection period (~ 9.5 to 14.7%) and later at the ~ time of vessel failure (3.5 - 7.9%). The sensitivity analysis indicated strong correlations between the uncertainty ranges and some parameters for the ice bed (hydrogen concentration limit for ignition and downward propagation, and maximum steam concentration limit for ignition). There were only weak or no correlation for burn parameters including upward and horizontal flame propagation limits.
11 Table 1. Reference MELCOR containment model for the Sequoyah plant.
CVH Nos.*
26-cell model Location 1
Cavity 2-5 Steam Gen. Doghouses 6
Upper Reactor Space 7
Pressurizer Doghouse 8-10 Lower Containment (Inside Crane Wall) 11-13 Lower Annulus (Between Crane Wall and Shell) 14-17 Lower Plenum 18-21 Ice bed 22-23 Upper Plenum 24-25 Upper Dome 26 Lower Dome & Operating Floor
- note the CVH package of MELCOR does not require that compartments (cells) be sequenced in any order.
Table 2. Selected MELCOR Sequoyah Sensitivity Runs Primary System Failure Times (Hours)
Hydrogen Cumulative Mass (Kg)
Core to Containment Run #
Vessel Hot Leg Generated in Core*
Hot Leg Pump Seals 21 6.37 5.57**
570 55.6 515.2 32 6.3 510 508.9 35 7.57 6.38 434.5 13.9 420.2 Rev 1 Rpt***
5.45 3.99 476 170 305
- At time of vessel failure
- (triple loop, single loop not failed)
- Hydrogen Control Calculation for the Sequoyah Plant: Station Blackout Scenario, April 2002 draft report.
Table 3. Ignition and propagation limits for deflagrations.
Limits X (H2)*
X (O2)
X (steam)
Ignition
>= 0.05
>= 0.05
<= 0.55 Upward propagation
>= 0.041
>= 0.05
<= 0.55 Horizontal propagation
>= 0.06
>= 0.05
<= 0.55 Downward propagation
>= 0.09
>= 0.05
<= 0.55
12 Table 4. Igniter locations used in the analysis of the Sequoyah plant.
Location Igniters Cavity No Steam Gen. Doghouses Yes Upper Reactor Space Yes Pressurizer Doghouse Yes Lower Containment (Inside Crane Wall)
Yes Lower Annulus (Between Crane Wall and Shell)
Yes Lower Plenum No Ice bed No Upper Plenum Yes Upper Dome Yes Lower Dome & Operating Floor Yes Table 5a. Hydrogen consumed in containment for period up to and including vessel breach (26-cell containment model), MELCOR run 21.*
Hydrogen consumed (kg)
Location Igniters only Igniters and fans Lower containment 229 (58.2)**
255.5 (61.4)
Ice condenser 159 (40.4) 105 (25.4)
Ice bed 111.4 (28.3) 25.9 (6.2)
Upper plenum 18.2 (4.6) 76.5 (18.4)
Lower plenum 29.4 (7.5) 2.7 (0.6)
Upper containment 5.6 (1.4) 55.4 (13.3)
Total 393.6 416
- Total hydrogen released to containment up to and including vessel breach is ~ 570 kg.
- Percentage of burned Table 5b. Hydrogen consumed in containment for period up to and including vessel breach (26-cell containment model), MELCOR run 32.*
Hydrogen consumed (kg)
Location Igniters only Igniters and fans Lower containment 254.4 (66.9)**
227 (60.5)
Ice condenser 126 (33.1) 102.8 (27.5)
Ice bed 96.8 (25.4) 18.6 (5.0)
Upper plenum 13.16 (3.5) 82.4 (22.0)
Lower plenum 16.0 (4.2) 1.8 (0.5)
Upper containment 0.0 (0.0) 45.4 (12.1)
Total 380.4 375.2
- Total hydrogen released to containment up to and including vessel breach is ~ 508kg.
- Percentage of burned
13 Table 5c. Hydrogen consumed in containment for period up to and including vessel breach (26-cell containment model), MELCOR run 35.*
Hydrogen consumed (kg)
Location Igniters only Igniters and fans Lower containment 163 (55.6)**
151 (49.1)
Ice condenser 127.3 (43.4) 97.5 (31.7)
Ice bed 93.8 (32.0) 20.5 (6.7)
Upper plenum 19.0 (6.5) 75.2 (24.5)
Lower plenum 14.5 (4.9) 1.8 (0.6)
Upper containment 2.74 (0.9) 59 (19.2)
Total 293 307.6
- Total hydrogen released to containment up to and including vessel breach is ~ 434kg
- Percentage of burned Table 6a. Hydrogen consumed in containment for period up to and including vessel breach (26-cell containment model) for MELCOR run 21, with no circulation through refueling drains.
Hydrogen consumed (kg)
Location Igniters only Igniters and fans Lower containment 135 (35.4)**
255.4 (60.9)
Ice condenser 238 (62.5) 104 (24.8)
Ice bed 181.5 (13.5) 20.5 (4.9)
Upper plenum 13.5 (3.5) 81.5 (19.4)
Lower plenum 43 (11.3) 2.0 (0.5)
Upper containment 7.9 (2.1) 60.0 (14.3)
Total 380.9 419.4
- Total hydrogen released to containment up to and including vessel breach is ~ 570 kg.
- Percentage of burned Table 6b. Hydrogen consumed in containment for period up to and including vessel breach (26-cell containment model) for MELCOR run 21, with no circulation through refueling drains and no lower plenum door leakage.
Hydrogen consumed (kg)
Location Igniters only Igniters and fans Lower containment 119 (28.8)**
268.0 (63.5)
Ice condenser 283.2 (68.4) 102.8 (24.2)
Ice bed 224 (54.1) 4.8 (1.1)
Upper plenum 29.2 (7.1) 97.0 (23.0)
Lower plenum 30.0 (7.2) 0.5 (0.1)
Upper containment 11.7 (2.8) 51.9 (12.3)
Total 413.9 422.2
- Total hydrogen released to containment up to and including vessel breach is ~ 570 kg.
- Percentage of burned
14 Table 7. Ice melt percentage at time of vessel failure Ice melt %
Source Term*
Igniters only Igniters with fans Run 21 46.7 64.2 Run 32 37.5 51.2 Run 35 46.1 64.9
- From MELCOR source term uncertainty study, see Table 2.
Table 8. Deflagration parameter uncertainty range Uncertainty Range, %
Parameter Low High Hydrogen conc limit for ignition with igniters 5 (5)*
7 Max vapor conc for ignition 45 (55) 65 Hydrogen conc limit for upward propagation 3 (4.1) 5 Hydrogen conc limit for horizontal propagation 5 (6) 7 Hydrogen conc limit for downward propagation 7 (9) 10
- (Default parameter)
Table 9. Maximum hydrogen concentration in Sequoyah containment for the STSBO_L accident event with igniters only (default deflagration parameters)
Concentration Location 3.5 - 5 hrs (pump seals)
~6.4 hrs (vessel failure)
Lower cont. (cell #9) 14 %
3.7%
Ice bed (cell #19) 9.5%
6.4%
Upper cont. (cell #24) 3.5%
4.1%
Table 10. Maximum hydrogen concentration uncertainty interval (95%/95%) in Sequoyah containment for the STSBO_L accident event with igniters only Concentration Location 3.5 - 5 hrs (pump seals)
~6.4 hrs (vessel failure)
Lower cont. (cell #9) 14 - 16.6%
3.2 - 4.6%
Ice bed (cell #19) 9.5 - 14.7%
3.5 - 7.9%
Upper cont. (cell #24) 3 - 4.6%
3.8 - 5.2%
15 Table 11. Spearman rank coefficients for the hydrogen burn parameter study at the 3.5 -
5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> period (pump seals)
Rank coefficient Parameter Cell #9 Cell #19 Cell #24 Hydrogen conc limit for ignition with igniters 0.96 0.66 0.435 Max vapor conc for ignition
-0.11
-0.47
-0.53 Hydrogen conc limit for upward propagation
-0.14
-0.07 0.19 Hydrogen conc limit for horizontal propagation 0.0068 0.03 0.35 Hydrogen conc limit for downward propagation 0.29 0.25 0.24 Table 12. Spearman rank coefficients for the hydrogen burn parameter study near the time of vessel failure ( ~ 6.4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />)
Rank coefficient Parameter Cell #9 Cell #19 Cell #24 Hydrogen conc limit for ignition with igniters 0.29 0.57 0.41 Max vapor conc for ignition
-0.20
-0.012
-0.1 Hydrogen conc limit for upward propagation 0.204
-0.05 0.17 Hydrogen conc limit for horizontal propagation 0.12 0.14 0.26 Hydrogen conc limit for downward propagation 0.21 0.413 0.10
16 Figure 1 Sequoyah containment drawing [Sequoyah FSAR].
17 Figure 2 Sketch of Sequoyah containment nodalization for the 26-cell MELCOR containment model.
18 Upper Plenum Ice Bed Lower Plenum Figure 3 Ice bed nodalization for the 26-cell MELCOR containment model.
19 0
100 200 300 400 500 600 700 800 0
2 4
6 8
10 Time, hr Hydrogen Mass, kg H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14 H15 H16 H17 H18 H19 H20 Figure 4 In-vessel hydrogen generation for MELCOR uncertainty runs #1 - #20.
20 0
100 200 300 400 500 600 700 800 0
2 4
6 8
10 Time, hr Hydrogen Mass, kg H21 H22 H23 H24 H25 H27 H27*
H28 H29 H30 H31 H32 H33 H34 H35 H36 H37 H38 H39 H40 Figure 5 In-vessel hydrogen generation for MELCOR uncertainty runs #21 - #40.
21 Figure 6 Approximate location for water, steam, and hydrogen injections.
22
-1 0
1 2
3 4
5 6
7 Time, hrs
-0.1
-0.0 0.1 0.2 0.3 0.4 0.5 0.6 Mass Rate, kg/s 0
100 200 300 400 500 600 Mass, kg Rate Integral Figure 7 Hydrogen injected through pump seals for MELCOR run 21.
23
-1 0
1 2
3 4
5 6
7 Time, hrs
-0.1 0.2 0.5 0.8 1.1 1.4 1.7 2.0 Mass Rate, kg/s 0
10 20 30 40 50 60 Mass, kg Rate Integral Figure 8 Hydrogen injection through hot leg (triple loop) for MELCOR run 21.
24
-1 0
1 2
3 4
5 6
7 Time, hrs
-10 0
10 20 30 40 50 60 70 Mass Rate, kg Figure 9 Steam injection from PORVs for MELCOR run 21.
25
-1 0
1 2
3 4
5 6
7 Time, hrs
-0.1
-0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Mass Rate, kg/s 0
100 200 300 400 500 600 Mass, kg Rate Integral Figure 10 In-vessel hydrogen generation for MELCOR run 21.
26
-1 0
1 2
3 4
5 6
7 Time, hrs 0
10 20 30 40 Mass Rate, kg Figure 11 Water injection from pump seals for MELCOR run 21.
27
-1 0
1 2
3 4
5 6
7 Time, hrs
-0.0 10.0 20.0 30.0 40.0 50.0 Mass Rate, kg/s Figure 12. Steam injection from pump seals for MELCOR run 21.
28
-1 1
3 5
7 Time, sec 300 800 1300 1800 Mass Rate, kg/s 0
10000 20000 30000 40000 50000 60000 Mass, kg Rate Integral Figure 13 Steam injection from hot leg break for MELCOR run 21 (no liquid water injection).
29
-1 0
1 2
3 4
5 6
7 Time, hrs
-0.1
-0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Mass Rate, kg/s 0
100 200 300 400 500 600 Mass, kg Rate Integral Figure 14. In-vessel hydrogen generation for MELCOR run 32.
30
-1 1
3 5
7 Time, hrs
-0.1
-0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Mass Rate, kg/s 0
100 200 300 400 500 Mass, kg Rate Integral Figure 15. In-vessel hydrogen generation for MELCOR run 35.
31
-1 0
1 2
3 4
5 6
7 Time, hrs 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Mass Rate, kg/s 0
100 200 300 400 500 600 Mass, kg Rate Integral Figure 16. Hydrogen injection from pump seals for MELCOR run 32.
32
-1 1
3 5
7 Time, hrs
-0.1 0.0 0.1 0.2 0.3 0.4 0.5 Mass Rate, kg/s 3
8 13 18 Mass, kg Rate Integral Figure 17. Hydrogen injection from hot leg failure for MELCOR run 35.
33
-1 1
3 5
7 Time, hrs 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Mass Rate, kg/s 0
100 200 300 400 500 Mass, kg Rate Integral Figure 18. Hydrogen injection from pump seals for MELCOR run 35.
34 0
100000 200000 300000 400000 500000 600000 700000 800000 0
1 2
3 4
5 6
7 time [hr]
Pressure [Pa]
Burn at VB No Burns 10% containment probability failure Figure 19. Containment pressure for MELCOR run 21 source term showing the overpressure that results from a delayed deflagration at the time of vessel failure.
35 0
50000 100000 150000 200000 250000 0
2 4
6 8
time [hr]
Pressure [Pa]
Without Igniters Igniters With Igniters and Fans Figure 20. Containment pressure using hydrogen source term from MELCOR run #21.
36 0
20000 40000 60000 80000 100000 120000 140000 160000 180000 200000 0
1 2
3 4
5 6
7 time [hr]
Pressure [Pa]
Without Igniters With Igniters With Igniters and fans Figure 21. Containment pressure using hydrogen source term from MELCOR run #32.
37 0
50000 100000 150000 200000 250000 0
2 4
6 8
time [hr]
Pressure [Pa]
Without Igniters With Igniters With Igniters and fans Figure 22. Containment pressure using hydrogen source term from MELCOR run #35.
38
-0.05 0
0.05 0.1 0.15 0.2 0.25 0.3 0
1 2
3 4
5 6
7 time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure 23. Hydrogen concentration in ice-bed for case without igniters, MELCOR run # 21.
39
-0.02 0
0.02 0.04 0.06 0.08 0.1 0.12 3
3.5 4
4.5 5
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure 24 Hydrogen concentration in ice-bed for case with igniters, MELCOR run # 21.
40
-0.01 0
0.01 0.02 0.03 0.04 0.05 0.06 0.07 3
3.5 4
4.5 5
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure 25. Hydrogen concentration in ice-bed for case with igniters and fans, MELCOR run # 21.
41
-0.05 0
0.05 0.1 0.15 0.2 0.25 0.3 0
1 2
3 4
5 6
7 time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure 26. Hydrogen concentration in ice-bed for case without igniters, MELCOR run # 32
42
-0.02 0
0.02 0.04 0.06 0.08 0.1 0.12 0.14 3
3.5 4
4.5 5
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure 27. Hydrogen concentration in ice-bed for case with igniters, MELCOR run # 32
43
-0.01 0
0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 3
3.5 4
4.5 5
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure 28. Hydrogen concentration in ice-bed for case with igniters and fans, MELCOR run # 32
44
-0.05 0
0.05 0.1 0.15 0.2 0.25 0
1 2
3 4
5 6
7 8
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure 29. Hydrogen concentration in ice-bed for case without igniters, MELCOR run # 35.
45
-0.02 0
0.02 0.04 0.06 0.08 0.1 0.12 3
4 5
6 7
8 time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure 30. Hydrogen concentration in ice-bed for case with igniters, MELCOR run # 35.
46
-0.01 0
0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 3
3.5 4
4.5 5
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure 31. Hydrogen concentration in ice-bed for case with igniters and fans, MELCOR run # 35.
47
-0.02 0
0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0
2 4
6 8
time [hr]
Mole Fraction Without Igniters With Igniters With Igniters and Fans Figure 4 Hydrogen concentration in upper containment (compartment #24) for MELCOR run #21.
48
-0.02 0
0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0
1 2
3 4
5 6
7 time [hr]
Mole Fraction Without Igniters With Igniters With Igniters and fans Figure 33. Hydrogen concentration in upper containment (compartment #24) for MELCOR run
- 32.
49
-0.02 0
0.02 0.04 0.06 0.08 0.1 0.12 0.14 0
2 4
6 8
time [hr]
Mole Fraction Without Igniters With Igniters With Igniters and fans Figure 34. Hydrogen concentration in upper containment (compartment #24) for MELCOR run #35
50
-0.1 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
0 1
2 3
4 5
6 7
time [hr]
Mole Fraction Steam Oxygen Hydrogen Figure 35. Containment atmosphere composition in compartment #9 (lower containment) for MELCOR run 21.
51
-3
-2.5
-2
-1.5
-1
-0.5 0
0.5 1
1.5 0
1 2
3 4
5 6
7 time [hr]
Mass Flow Rate [kg/s]
FL-MFLOW.4.51 FL-MFLOW.4.59 Figure 36. Oxygen flows for the refueling drains, showing the transfer of oxygen from the upper containment to the lower containment (negative flows).
Appendix A: Fully-coupled RCS/containment Plant Calculations for Sequoyah Two long-term (CCI) fully-coupled RCS/containment plant calculations were completed for 1) a case without power to igniters and 2) with power to igniters only. The calculations were made using a detailed, 26-cell containment model. The scenario was a short-term station blackout with pump seal leakage (250 gpm) as described in the Sandia report Hydrogen Source Terms for Station Blackout Accidents in Sequoyah and Grand Gulf Estimated Using MELCOR 1.8.5, July 26, 2001. More recent source terms calculations have been performed, however conclusions based on earlier source terms are not expected to change, even with more recent source terms.
Shown in Figures 1-8 are representative plots for the extended STSBO_L Sequoyah runs out to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, with and without igniters. The calculations differ in small degrees from decoupled, containment only runs (to vessel failure only) mainly because of the addition of radioactive fission products in the containment for the coupled (RCS plus containment) calculations. In the current MELCOR code (revision RE1 used here),
transfer of radioactive (also non-radioactive) products from the RCS to the containment atmosphere is possible only for decoupled (i.e., standalone containment analysis) calculations involving cavity models.
What can be clearly noted in these comparison calculations without power to igniters is
- 1) significant late time overpressurization, and 2) the very dangerous potential for detonations in the dome late in the accident after vessel failure and during CCI. The case with igniters shows that hydrogen control is effective for this late time period, with attendant reduction in overpressurization Additionally, the late time hydrogen concentration increase, even with igniters, is during the time when there is insufficient oxygen available for burning.
[In the figures below, the compartment and gas component designation is noted in the legend. For example cvh-x.3.9 represents the steam(3) component in compartment #9 (lower containment region), cvh-x.4.9 is the oxygen (4) component, and cvh-x.6.9 is the hydrogen (6) component.]
Appendix A 1
CVH-P.24 0
50000 100000 150000 200000 250000 300000 350000 400000 0
5 10 15 20 25 30 time [hr]
Pressure [Pa]
CVH-P.24 Figure A1. Sequoyah containment pressure without igniters CVH-P.24 0
50000 100000 150000 200000 250000 300000 350000 0
5 10 15 20 25 30 time [hr]
Pressure [Pa]
CVH-P.24 Figure A2. Sequoyah containment pressure with igniters Appendix A 2
-0.1 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
0 5
10 15 20 25 30 time [hr]
Mole Fraction CVH-X.3.9 CVH-X.4.9 CVH-X.6.9 Figure A3. Gas concentrations in lower compartment (cell #9) for case without igniters
-0.05 0
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0
5 10 15 20 25 30 time [hr]
Mole Fraction CVH-X.3.20 CVH-X.4.20 CVH-X.6.20 Figure A4. Gas concentrations in ice bed ( cell #20) for case without igniters Appendix A 3
-0.05 0
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0
5 10 15 20 25 30 time [hr]
Mole Fraction CVH-X.3.24 CVH-X.4.24 CVH-X.6.24 Figure A5. Gas concentrations in dome ( cell #24) for case without igniters
-0.1 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
0 5
10 15 20 25 30 time [hr]
Mole Fraction CVH-X.3.9 CVH-X.4.9 CVH-X.6.9 Figure A6. Gas concentrations in lower containment ( cell #9) for case with igniters Appendix A 4
-0.1 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0
5 10 15 20 25 30 time [hr]
Mole Fraction CVH-X.3.20 CVH-X.4.20 CVH-X.6.20 Figure A7. Gas concentrations in ice bed ( cell #20) for case with igniters
-0.1 0
0.1 0.2 0.3 0.4 0.5 0.6 0
5 10 15 20 25 30 time [hr]
Mole Fraction CVH-X.3.24 CVH-X.4.24 CVH-X.6.24 Figure A8. Gas concentrations in dome ( cell #24) for case with igniters Appendix A 5
Appendix B: Nodalization Study for the Sequoyah Containment The standalone, multi-cell analysis for the Sequoyah plant containment began with a decision regarding the nodalization scheme. In general, there are guidelines that aid in determining an acceptable strategy for the compartmentalization of the containment: 1) assign separate cells to each well defined physical compartment or room; 2) compartmentalize so that physically probable flows are not eliminated; 3) minimize the degree of open compartment sub-nodalization; 4) nodalize to allow a physical representation of standing liquid pools and pool transport paths; and finally, 5) investigate result dependency for potential nodalization schemes. Typically, these guidelines may also include consideration for code CPU run times, degree of geometrical data available, time constraints for the input preparation, and the type of results required (global or local). For the Sequoyah containment, the guidelines for containment nodalization were followed for the most part, using a 26-cell model previously developed for direct containment heating studies as the initial reference nodalization scheme, Figure B1. Some variations however on this model were used in the preparation of this report to determine result dependency; this appendix discusses that usage. For all the calculations reported in this appendix, the sources to the containment are from MELCOR run 21 described in the report.
Nodalization schemes The simplest model used in this study was the 12-cell nodalization used in the fully coupled MELCOR RCS/containment calculations to generate the source terms for the standalone containment analysis. Due to the weak coupling between the RCS and containment and the need to reduce CPU time, a detailed nodalization of the containment was not used for the coupled calculations. The 12-cell nodalization model is described in Table B1, using the compartment numbering and location portrayed in the sketch of the containment in Figure B1. Note that in the 12-cell model the ice bed is modeled with a single cell, as indicated in Figure B2 (a).
During the mid-80s when multi-cell, lumped-parameter analyses of ice condenser type containments were just appearing in the literature, a number of analyses were conducted with the ice bed modeled using vertically stacked cells. These configurations, most notable in early HECTR code analyses,1 precluded the possibility of vertical mixing that could occur within the ice bed due to the substantial hydrostatic heads that develop during post-blowdown periods. For completeness and a demonstration of the extreme case that limits vertical mixing, a nodalization case was included here to investigate global and local results using stacked, ice bed vertical cells. This scheme, built on the 12-cell model, included an additional three cells in the ice bed. The 15-cell model is described in Table B1. Stacking of the cells in the ice bed is shown in Figure B2 (b).
1 Camp, A. L., et al., MARCH-HECTR Analysis of Selected Accidents in an Ice Condenser Containment, NUREG/CR-3912, SAND83-0501, December, 1984.
Dingman, S. E., et al., HECTR Version 1.5 Users Manual, NUREG/CR-4507, SAND86-0101, April, 1986.
Appendix B 1
In order to allow more detailed representation of the lower compartment source injection, including the asymmetric characterization of the sources, the 12-cell model was replaced with the 26-cell model, configured as shown in Figure B1. The description of the model is given in Table B2. One of the more noticeable modifications from the 12-cell model is the addition of four asymmetric cells in the ice bed region, Figure B3. Each vertical cell in the region is connect to adjacent cells by upper and lower connecting flow paths to allow horizontal mixing due to variations in developing static heads.
The 26-cell model does not resolve potential vertical gradients that may occur in the ice bed due to stratifying layers that may develop due to light gas injection and/or local steam condensation and ice melt-out. The potential for vertical/horizontal mixing within the ice bed was noted in early HECTR analyses, and later investigated using a detailed nodalization of the ice bed as indicated in Figure B4.2 To investigate the effect of gross circulation patterns in the ice bed, an ice condenser nodalization scheme similar to that shown in Figure B4 was applied to the 26-cell model, resulting in a 38-cell model. The ice condenser model for this scheme is shown in Figure B5.
Comparison of 12 and 15-cell Model Results Shown in Figure B6 are the containment pressure response curves for cases where there is no auxiliary power supplied to the containment igniters or fans. The higher pressure obtained with the 15-cell model occurs as a consequence of the increase in ice bed gas mixture density that develops during the early injection. Without ice bed mixing, severe density gradients develop, resulting in an inversion condition where high density gas regions form over lower density regions, Figure B7. The gas densities in the case of the stacked cells can be compared to the significantly lower densities that occur with the single, well-mixed ice bed cell in the 12-cell model, Figure B8. Shown in Figure B9 and B10 are the hydrogen concentrations in the ice bed for the 12 and 15-cell models, respectively. Here we see that hydrogen concentration maximum is less in the 15-cell model as in the 12-cell model. This is due in part to the variation in the lower plenum to ice bed flows between each model.
Comparison of 26 and 38-cell Model Results Shown in Figure B11 are the containment pressure response curves for the 26 and 38-cell models where there is no auxiliary power supplied to the containment igniters or fans.
Both pressure curves are essentially identical. This would imply that the ice bed mixing (hydrostatic heads) is also similar; and, this is confirmed from the ice bed hydrogen concentrations for each model, Figures B12 and B13.
In the case where igniters are powered (without fans), we note that again the ice bed hydrogen concentrations are similar as shown in Figures B14 and B15. There is a small increase in the local maximum hydrogen concentration observed with the 38-cell model -
local concentration peak ~12% for the 38-cell model as compared to ~ 9% with the 26-2 Dingman, S. E. and Camp, A. L., Pressure-Temperature Response in an Ice-Condenser Containment for Selected Accidents, SAND85-1824C, Appendix B 2
cell model. The cells in the 38-cell model that reach ~12% hydrogen concentration are cells # 31 and 32. The remaining cells have concentrations that are essentially the same as noted in the 26-cell model. The cause of the slightly higher concentrations for these upper cells during periods of intermittent burns is difficult to analyze. The cause may be a combination of mixing processes modeled in more detail in the 38-cell model and the changes in concentration due to the flame speed and propagation characteristics affected also by the different nodalizations. What can be suggested however from the comparisons of both models, with and without igniters powered, is that the general behavior of the hydrogen distribution in both models is essentially identical for nearly all the time when the ice bed is in a flammable condition. Therefore, for the purpose of this scoping study there is no strong argument for selecting the 38-cell over the 26-cell model.
For this reason and others mentioned in the report concerning burn model implementation (consistency) and efficiency, the 26-cell model is used as the reference standalone containment model for the report.
Appendix B 3
Table B1. MELCOR nodalization for the 12 and 15-cell containment models.
CVH Nos.*
12-cell 15-cell Location 1
1 Cavity 2-3 2-3 Steam Gen. Doghouses 6
6 Upper Reactor Space 7
7 Pressurizer Doghouse 8-9 8-9 Lower Containment (Inside Crane Wall) 11 11 Lower Annulus (Between Crane Wall and Shell) 14 14 Lower Plenum 18 18-21 Ice bed 22 22 Upper Plenum Upper Dome 24 24 Lower Dome & Operating Floor
- note the CVH package of MELCOR does not require that compartments (cells) be sequenced in any order.
Table B2.. MELCOR nodalization for the 26 and 38-cell containment models.
CVH Nos.
26-cell*
38-cell Location 1
1 Cavity 2-5 2-5 Steam Gen. Doghouses 6
6 Upper Reactor Space 7
7 Pressurizer Doghouse 8-10 8-10 Lower Containment (Inside Crane Wall) 11-13 11-13 Lower Annulus (Between Crane Wall and Shell) 14-17 14-17 Lower Plenum 18-21 18-33 Ice bed 22-23 34-35 Upper Plenum 24-25 36-37 Upper Dome 26 38 Lower Dome & Operating Floor
- reference containment model Appendix B 4
Figure B1. Sketch of Sequoyah containment nodalization for the 26-cell MELCOR containment model.
Appendix B 5
Upper Plenum Ice Bed Lower Plenum Upper Plenum Ice Bed Lower Plenum Figure B2. Ice condenser nodalization for the (a) 12-cell and (b) 15-cell model of the Sequoyah containment.
Appendix B 6
Upper Plenum Ice Bed Lower Plenum Figure B3. Ice condenser nodalization for the 26-cell model of the Sequoyah containment.
Appendix B 7
Figure B4. Sketch of the detailed ice condenser nodalization used for HECTR analysis of the Sequoyah containment [SAND85-1824C].
Appendix B 8
Upper Plenum Ice Bed Lower Plenum Figure B5. Ice condenser nodalization for the 38-cell model of the Sequoyah containment.
Appendix B 9
0 50000 100000 150000 200000 250000 300000 350000 0
1 2
3 4
5 6
time [hr]
Pressure [Pa]
12-cell model 15-cell model Figure B6. Containment pressure response for the STSBO-L accident, without auxiliary power.
Appendix B 10
0 0.5 1
1.5 2
2.5 3
3.5 0
1 2
3 4
5 6
time [hr]
Mass Density [kg/m**3]
CVH-RHO.18 CVH-RHO.19 CVH-RHO.20 CVH-RHO.21 Figure B7. Ice bed gas mixture density for the STSBO-L accident using the 15-cell model, without auxiliary power.
Appendix B 11
CVH-RHO.18 0
0.5 1
1.5 2
2.5 0
1 2
3 4
5 6
time [hr]
Mass Density [kg/m**3]
CVH-RHO.18 Figure B8. Ice bed gas mixture density for the STSBO-L accident using the 12-cell model, without auxiliary power.
Appendix B 12
CVH-X.6.18
-0.05 0
0.05 0.1 0.15 0.2 0.25 0.3 0
1 2
3 4
5 6
time [hr]
Mole Fraction CVH-X.6.18 Figure B9. Ice bed hydrogen concentration for the STSBO-L accident using the 12-cell model, without auxiliary power.
Appendix B 13
-0.05 0
0.05 0.1 0.15 0.2 0
1 2
3 4
5 6
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure B10. Ice bed hydrogen concentration for the STSBO-L accident using the 15-cell model, without auxiliary power.
Appendix B 14
0 50000 100000 150000 200000 250000 0
1 2
3 4
5 6
7 time [hr]
Pressure [Pa]
26-cell model 38-cell model Figure B11. Containment pressure response for the STSBO-L accident using the 26 and 38-cell models, without auxiliary power.
Appendix B 15
-0.05 0
0.05 0.1 0.15 0.2 0.25 0.3 3
4 5
6 7
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure B12. Ice bed hydrogen concentrations for the STSBO-L accident using the 26-cell model, without auxiliary power.
Appendix B 16
-0.05 0
0.05 0.1 0.15 0.2 0.25 0.3 0
1 2
3 4
5 6
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 CVH-X.6.22 CVH-X.6.23 CVH-X.6.24 CVH-X.6.25 CVH-X.6.26 CVH-X.6.27 CVH-X.6.28 CVH-X.6.29 CVH-X.6.30 CVH-X.6.31 CVH-X.6.32 CVH-X.6.33 Figure B13. Ice bed hydrogen concentrations for the STSBO-L accident using the 38-cell model, without auxiliary power.
Appendix B 17
-0.02 0
0.02 0.04 0.06 0.08 0.1 0.12 3
3.5 4
4.5 5
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 Figure B14. Ice bed hydrogen concentrations for the STSBO-L accident using the 26-cell model, with auxiliary power to igniters.
Appendix B 18
-0.02 0
0.02 0.04 0.06 0.08 0.1 0.12 0.14 0
1 2
3 4
5 6
time [hr]
Mole Fraction CVH-X.6.18 CVH-X.6.19 CVH-X.6.20 CVH-X.6.21 CVH-X.6.22 CVH-X.6.23 CVH-X.6.24 CVH-X.6.25 CVH-X.6.26 CVH-X.6.27 CVH-X.6.28 CVH-X.6.29 CVH-X.6.30 CVH-X.6.31 CVH-X.6.32 CVH-X.6.33 Figure B15. Ice bed hydrogen concentrations for the STSBO-L accident using the 38-cell model, with auxiliary power to igniters.
Appendix B 19
Appendix C: MELGEN/MELCOR Input Files for Igniter Only Sequoyah Containment Calculation The MELGEN input files for the igniter only Sequoyah containment calculation using the 26-cell model are: sbo.inp, mp.gen, s_cont.gen, and s_small_burn.gen. The sources to the containment (external files) for the hot leg (hl1 - single loop, hl3 - triple loop),
surgeline (sl), relief valves (rv), seals (seal8 and seal10), and vessel (vessel) are indicated for each receiving compartment. These external files are changed depending on the MELCOR run used to generate the source terms (run #). The MELCOR input file is listed as sbo.cor.
MELGEN Files:
SBO.INP
- SBO Comparison Calculation *
- Using the MELCOR 26-cell input
- title 'STSBO_L Containment' restartf SBO_Case1.rst outputf SBO_Case1.out diagf SBO_Case1_g.dia dttime 0.1
- Read data from external files *
- mp.gen NCG and material properties
- s_cont.gen Containment model
- Active
- r*i*f.\\mp.gen r*i*f.\\s_cont.gen r*i*f.\\s_small_burn.gen Appendix C 1
S_SMALL_BURN.GEN
- BURN PACKAGE MODIFIED BY Ahill 8-7-00 BUR000 0
- ACTIVE
- BUR000 1
- INACTIVE BUR001 0.99 0.167 0.05 0.129 0.05 0.55 0.10 0.167 0.05 0.55 BUR002 0.99 0.09 0.30 BUR004 -1 BUR101 001 0
- no ignitor in cavity BUR102 002 -915 BUR103 003 -915 BUR104 004 -915 BUR105 005 -915 BUR106 006 -915 BUR107 007 -915 BUR108 008 -915 BUR109 009 -915 BUR110 010 -915 BUR111 011 -915 BUR112 012 -915 BUR113 013 -915 BUR114 014 0
- no ignitor in lower plenum BUR115 015 0 BUR116 016 0 BUR117 017 0 BUR118 018 0
- ignitor in ice bed for vessel breach BUR119 019 0 BUR120 020 0 BUR121 021 0 BUR122 022 -915 BUR123 023 -915 BUR124 024 -915 BUR125 025 -915 BUR126 026 -915 CF04100 BURN_FLAG L-GT 2 1.0 CF04101.FALSE.
CF04110 1.0 0.0 TIME CF04111 0.0 0.0 TIME
- Ignitors if set to true CF91500 'ignitoron' l-a-ifte 3 1.0 0.0 *Ignitors off if pwr off (cf041)
CF91510 1.0 0.0 cfvalu.041
- if cf041 is true, then CF91511 0.0 1.0 time
- ignitors on, otherwise CF91512 0.0 0.0 time
- ignitors off Appendix C 2
- CVTYPE input CVTYPE01 Vessel CVTYPE02 PL-1 CVTYPE03 PL-3 CVTYPE04 Ctmt CVTYPE05 SurgTnk CVTYPE06 SG-1 CVTYPE07 SG-3 CVTYPE09 ECCS CVTYPE10 AuxFW CVTYPE11 Pressrz CVTYPE98 Envir1 CVTYPE99 Envir2
- NON-CONDENSIBLE GASES
- GAS MATERIAL NUMBER NCG000 O2 4 NCG001 N2 5 NCG002 H2 6 NCG003 CO2 7 NCG004 CO 8 NCG005 CH4 9
- MATERIAL PROPERTIES
- Property Units
- temperature K
- density kg/m*3
- heat capacity J/kg-K
- thermal conductivity W/m-K
- Material 1 is steel MPMAT00100 STEEL
- Density of steel TF00100 'RHO STEEL' 2 1.00 0.0
- TEMPERATURE RHO TF00112 200.00 7808.01 *487 lb/ft^3 'DEN(NM)' SLAB TF00113 5000.00 7808.01
- Heat capacity of steel Appendix C 3
TF00200 'CPS STEEL' 2 1.00 0.0
- TEMPERATURE CPS TF00212 200.00 475.72 *0.113 BTU/LB/F 'HC(NM)' SLAB TF00213 5000.00 475.72
- Thermal conductivty of steel TF00300 'THC STEEL' 2 1.00 0.0
- Material 2 is concrete MPMAT00200 CONCRETE
- Density of concrete TF00400 'RHO CONCRETE' 2 1.00 0.0
- TEMPERATURE RHO TF00412 200.00 2533.19 *157.5 LB/FT^3 'DEN(NM) SLAB TF00413 5000.00 2533.19
- Heat capacity of concrete TF00500 'CPS CONCRETE' 2 1.00 0.0
- TEMPERATURE CPS TF00512 200.00 880.0
- MODIFIED BY IKM 4-03-95 TF00513 5000.00 880.0
- Thermal conductivity of concrete TF00600 'THC CONCRETE' 2 1.00 0.0
- PROPERTY TAB FUNC MPMAT00301 RHO 7 MPMAT00302 CPS 8 Appendix C 4
MPMAT00303 THC 9
- TEMPERATURE RHO TF00712 273.15 7833.0 TF00713 5000.00 7833.0
- TEMPERATURE CPS TF00812 273.15 465.0 TF00813 5000.00 465.0
- TEMPERATURE THC TF00910 273.15 55.0 TF00911 373.15 52.0 TF00912 473.15 48.0 TF00913 573.15 45.0 TF00914 673.15 42.0 TF00915 873.15 35.0 TF00916 1073.15 31.0 TF00917 1223.15 29.0 TF00918 1473.15 31.0 TF00919 9973.15 31.0
- MATERIAL 4 IS SS-3161 MPMAT00400 'SS-3161'
- Density of carbon steel TF07000 'RHO SS-3161' 2 1.00 0.0
- TEMPERATURE RHO TF07012 273.15 7930.0 TF07013 5000.00 7930.0
- HEAT CAPACITY OF SS-3161 TF08000 'CPS SS-3161' 2 1.00 0.0
- TEMPERATURE CPS Appendix C 5
TF08012 273.15 381.1 TF08013 5000.00 381.1
- THERMAL CONDUCTIVTY OF SS-3161 TF09000 'THC SS-3161' 7 1.00 0.0
- TEMPERATURE THC TF09010 273.15 17.0 TF09011 310.90 17.0 TF09012 422.00 18.92 TF09013 553.10 21.18 TF09014 644.30 23.21 TF09015 755.40 25.22 TF09016 866.50 29.51
- insul solid
- molew 60.0
- condt 1.454 1.454
- entht 3.375e4 3.409e6
- rhot 2000.0 2000.0
- spht 1250.0 1250.0
- Density TF01100 'RHO insul' 1 1.00 0.0 TF01110 300.0 2000.0
- Specific Heat TF01200 'CPS insul' 1 1.00 0.0 TF01210 300.0 1250.0
- Conductivity TF01300 'THC insul' 1 1.00 0.0 TF01310 300.0 1.454
- Thermal conductivity of ice is 2.18 W/m/K
- Large value used here to accomodate lump-capacity model
- Same as NRC's Cook model tf01400 'thc ice' 2 1. 0.
tf01411 273.15 50.
tf01420 5000. 50.
Appendix C 6
- Specific heat capacity of ice is 2040 J/kg/K at freezing
- Low value used here because heat capacities were included in
- heat of reaction of the degassing-ice-condenser-model.
- Same as NRC's Cook model.
tf01500 'cps ice' 2 1. 0.
tf01511 273.15 1.
tf01518 5000. 1.
- Density of solid ice is about 915 kg/m3
- Density of granulated ice on order of 575 to 700 kg/m3
- See calculation of density in ice condensor input (below) tf01600 'rho ice' 2 1. 0.
- granulated ice tf01611 273.15 596.77 tf01612 5000. 596.77
- The following (Inconel MP Data) was taken from the Surry deck Ahill
- MATERIAL 7 IS INCONEL MPMAT00700 INCONEL MPMAT00701 RHO 17 MPMAT00702 CPS 18 MPMAT00703 THC 19 TF01700 'RHO INCONEL' 1 1.00 0.0 TF01710 273.15 8415.0 TF01800 'CPS INCONEL' 1 1.00 0.0 TF01810 273.15 439.0 TF01900 'THC INCONEL' 7 1.00 0.0 TF01910 310.928 14.704 TF01911 422.039 16.636 TF01912 533.150 18.318 TF01913 644.261 20.063 TF01914 755.372 21.807 TF01915 866.483 23.552 TF01916 1922.039 41.060
- Vessel temp for heat transfer TF11000 Temp 2 1.0 0.0
- Time Temp TF11010 0.0 616.0 TF11011 1.0E10 616.0
- HEAT TRANSFER COEFFICIENT FOR STRUCTURE INSULATION
- BASED ON REFLECTIVE INSULATION PROPERITES TAKEN
- FROM DEGRADED INSULATION SCOPING STUDY, RJD-32-87,
- 9/30/87. COEFFICIENT ASSUMMED CONSTANT BELOW AND
- ABOVE ENDPOINTS OF DATA GIVEN IN PAPER.
TF70000 'PIPE INSULATION' 4 1.00 0.0
- TEMPERATURE HTC TF70010 273.15 1.14 TF70011 422. 1.14 Appendix C 7
TF70012 1089. 3.68 TF70013 5000. 3.68 S_SMALL_CONT.GEN
- Sequoyah 26-Cell Containment Model. Converted from CONTAIN input deck
- External data file write *
- pressure and ice melt
- edf00100 seq_data 8 write edf00101 'seq_data.txt' edf00102 '1P,9e14.5' edf00110 0. 30.0 edf001aa cvh-p.024 edf001bb cfvalu.152
- peak-pressure cv024 edf001cc cfvalu.841
- lw-door1 edf001dd cfvalu.843
- lw-door2 edf001ee cfvalu.860
- lw-door3 edf001ff cfvalu.870
- lw-door4 edf001gg cfvalu.880
- lw-door5 edf001hh cfvalu.890
- lw-door6
- CVH Input *
- reactor cavity *
- Cell number = 1
- Cell bottom = -3.5200 m
- cell top = 3.5200 m
- Cell height = 7.0400 m
- Cell volume = 396.0000 m3 cv00100 cavity 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv001a0 3 cv001a1 pvol 1.013e5 cv001a2 tatm 311.
cv001a3 mlfr.4 0.2095 cv001a4 mlfr.5 0.7905 cv001a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv001b1 -3.5200 0.0000
- cv001b2 3.5200 396.0000
- External files for sources
- cv001c1 file integral edf.010 1.0 Appendix C 8
edf01000 'vessel' 11 read edf01001 'vessel.dat' edf01002 '12(1x,1pe20.9)'
- steam generator doghouse #1 *
- Cell number = 2
- Cell bottom = 21.4000 m
- cell top = 32.6000 m
- Cell height = 11.2000 m
- Cell volume = 362.5000 m3 cv00200 sg_doghouse_1 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv002a0 3 cv002a1 pvol 1.010e5 cv002a2 tatm 311.
cv002a3 mlfr.4 0.2095 cv002a4 mlfr.5 0.7905 cv002a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv002b1 21.4000 0.0000 cv002b2 32.6000 362.5000
- steam generator doghouse #2 *
- Cell number = 3
- Cell bottom = 21.4000 m
- cell top = 32.6000 m
- Cell height = 11.2000 m
- Cell volume = 362.5000 m3 cv00300 sg_doghouse_2 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv003a0 3 cv003a1 pvol 1.010e5 cv003a2 tatm 311.
cv003a3 mlfr.4 0.2095 cv003a4 mlfr.5 0.7905 cv003a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv003b1 21.4000 0.0000 cv003b2 32.6000 362.5000
- steam generator doghouse #3 *
- Cell number = 4
- Cell bottom = 21.4000 m
- cell top = 32.6000 m
- Cell height = 11.2000 m
- Cell volume = 362.5000 m3 cv00400 sg_doghouse_3 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv004a0 3 cv004a1 pvol 1.010e5 cv004a2 tatm 311.
cv004a3 mlfr.4 0.2095 cv004a4 mlfr.5 0.7905 cv004a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv004b1 21.4000 0.0000 Appendix C 9
cv004b2 32.6000 362.5000
- steam generator doghouse #4 *
- Cell number = 5
- Cell bottom = 21.4000 m
- cell top = 32.6000 m
- Cell height = 11.2000 m
- Cell volume = 362.5000 m3 cv00500 sg_doghouse_4 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv005a0 3 cv005a1 pvol 1.010e5 cv005a2 tatm 311.
cv005a3 mlfr.4 0.2095 cv005a4 mlfr.5 0.7905 cv005a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv005b1 21.4000 0.0000 cv005b2 32.6000 362.5000
- reactor space - upper cavity *
- Cell number = 6
- Cell bottom = 12.1000 m
- cell top = 19.9000 m
- Cell height = 7.8000 m
- Cell volume = 439.0000 m3 cv00600 Upper_Cavity 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv006a0 3 cv006a1 pvol 1.01122e5 cv006a2 tatm 311.
cv006a3 mlfr.4 0.2095 cv006a4 mlfr.5 0.7905 cv006a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv006b1 12.1000 0.0000 cv006b2 19.9000 439.0000
- pressurizer doghouse *
- Cell number = 7
- Cell bottom = 21.4000 m
- cell top = 32.6000 m
- Cell height = 11.2000 m
- Cell volume = 135.0000 m3 cv00700 Pszr_Doghouse 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv007a0 3 cv007a1 pvol 1.010e5 cv007a2 tatm 311.
cv007a3 mlfr.4 0.209 cv007a4 mlfr.5 0.790 cv007a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv007b1 21.4000 0.0000 cv007b2 32.6000 135.0000 Appendix C 10
- lower containment #1 *
- Cell number = 8
- Cell bottom = 5.3000 m
- cell top = 19.3000 m
- Cell height = 14.0000 m
- Cell volume =1510. m3 cv00800 lwr_ctmt_1 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv008a0 3 cv008a1 pvol 1.01163e5 cv008a2 tatm 311.
cv008a3 mlfr.4 0.209 cv008a4 mlfr.5 0.790 cv008a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv008b1 1.14 0.0000 cv008b2 5.3 60.467 cv008b3 6.47 186.66 cv008b4 8.53 408.846 cv008b5 19.3000 1510.0000 cv008ca file integral edf.050 1.0 cv008cb file integral edf.080 0.333 cv008cc file integral edf.100 1.0 edf05000 'hl1' 11 read
- Vessel nozzle (hot-1 leg) edf05001 'hl1.dat' edf05002 '12(1x,1pe20.9)'
edf08000 'hl3a' 11 read
- Vessel nozzle (hot-3 leg)*1/3 edf08001 'hl3a.dat' edf08002 '12(1x,1pe20.9)'
edf10000 'seal8' 11 read
- Seals (loops 1 and 3) edf10001 'seal8.dat' edf10002 '12(1x,1pe20.9)'
- lower containment #2 *
- Cell number = 9
- Cell bottom = 5.3000 m *$$$Bottom should be at 4.639056m below nozzle
- cell top = 19.3000 m *$$$ = 8.324 - 4.639056 = 3.684944 SQ FSAR 6.2-23
- Cell height = 14.0000 m
- Cell volume =1290. m3 cv00900 lwr_ctmt_2 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv009a0 3 cv009a1 pvol 1.01163e5 cv009a2 tatm 311.
cv009a3 mlfr.4 0.209 cv009a4 mlfr.5 0.790 cv009a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv009b1 1.14 0.0000 cv009b2 5.3 60.467 cv009b3 6.47 154.213 cv009b4 8.53 319.269 cv009b5 21.4000 1290.0000 Appendix C 11
- Input steam, water, and hydrogen sources
- cv009ce file integral edf.030 1.0 cv009cf file integral edf.040 1.0
- cv009cg file integral edf.060 1.0
- cv009ch file integral edf.070 1.0
- edf files for source input *
- edf02000 'flo_450' 11 read
- edf02001 'flo_450.dat'
- edf00700 'water' 2 read
- Rupture Disk
- edf00701 'water.dat'
- edf00702 '3(1x,1pe12.4)'
- edf00800 'steam' 2 read
- Rupture Disk
- edf00801 'steam.dat'
- edf00802 '3(1x,1pe12.4)'
edf03000 'rv' 11 read
- Relief Values edf03001 'rv.dat' edf03002 '12(1x,1pe20.9)'
edf04000 'sl' 11 read
- surgelines edf04001 'sl.dat' edf04002 '12(1x,1pe20.9)'
- edf06000 'flo_895' 11 read
- Surgeline rupture
- edf06001 'flo_895.dat'
- edf07000 'flo_896' 11 read
- Surgeline rupture CV503
- edf07001 'flo_896.dat'
- lower containment #3 *
- Cell number = 10
- Cell bottom = 5.3000 m
- cell top = 19.3000 m
- Cell height = 14.0000 m
- Cell volume =1510. m3 cv01000 lwr_ctmt_3 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv010a0 3 cv010a1 pvol 1.01163e5 cv010a2 tatm 311.
cv010a3 mlfr.4 0.209 cv010a4 mlfr.5 0.790 cv010a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv010b1 1.14 0.0000 cv010b2 5.3 60.467 cv010b3 6.47 186.66 cv010b4 8.53 408.846 Appendix C 12
cv010b5 19.3000 1510.0000
- External file read sources
- cv010ca file integral edf.140 0.6666
- cv010cb file integral edf.120 1.0
- cv010cc file integral edf.130 1.0 cv010cd file integral edf.090 1.0
- cv010ce file integral edf.110 1.0 edf14000 'hl3b' 11 read
- Vessel nozzle rupture (hot-3 leg)* 2/3 edf14001 'hl3b.dat' edf14002 '12(1x,1pe20.9)'
edf09000 'seal10' 11 read
- seals edf09001 'seal10.dat' edf09002 '12(1x,1pe20.9)'
- edf09000 'flo_903' 11 read
- A loop 3
- edf09001 'flo_903.dat'
- edf11000 'flo_913' 11 read
- B loop 3
- edf11001 'flo_913.dat'
- edf12000 'flo_902' 11 read
- A loop 3
- edf12001 'flo_902.dat'
- edf13000 'flo_912' 11 read
- B loop 3
- edf13001 'flo_912.dat'
- lower annulus #1 *
- Cell number = 11
- Cell bottom = 5.3000 m
- cell top = 19.3000 m
- Cell height = 14.0000 m
- Cell volume = 864.0000 m3 cv01100 lwr_annulus_1 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv011a0 3 cv011a1 pvol 1.01163e5 cv011a2 tatm 311.
cv011a3 mlfr.4 0.209 cv011a4 mlfr.5 0.790 cv011a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv011b1 5.3000 0.0000 cv011b2 19.3000 864.0000
- lower annulus #2 *
- Cell number = 12
- Cell bottom = 5.3000 m
- cell top = 19.3000 m
- Cell height = 14.0000 m
- Cell volume = 846.0000 m3 cv01200 lwr_annulus_2 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv012a0 3 Appendix C 13
cv012a1 pvol 1.01163e5 cv012a2 tatm 311.
cv012a3 mlfr.4 0.2095 cv012a4 mlfr.5 0.7905 cv012a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv012b1 5.3000 0.0000 cv012b2 19.3000 846.0000
- lower annulus #3 *
- Cell number = 13
- Cell bottom = 5.3000 m
- cell top = 19.3000 m
- Cell height = 14.0000 m
- Cell volume = 952.0000 m3 cv01300 lwr_annulus_3 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv013a0 3 cv013a1 pvol 1.01163e5 cv013a2 tatm 311.
cv013a3 mlfr.4 0.2095 cv013a4 mlfr.5 0.7905 cv013a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv013b1 5.3000 0.0000 cv013b2 19.3000 952.0000
- lower plenum #1 *
- Cell number = 14
- Cell bottom = 17.7500 m
- cell top = 20.2500 m
- Cell height = 2.5000 m
- Cell volume = 171.2500 m3 cv01400 lwr_plenum_1 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv014a0 3 cv014a1 pvol 1.01089e5 cv014a2 tatm 275.0 cv014a3 mlfr.4 0.2095 cv014a4 mlfr.5 0.7905 cv014a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv014b1 17.7500 0.0000 cv014b2 20.2500 171.2500
- lower plenum #2 *
- Cell number = 15
- Cell bottom = 17.7500 m
- cell top = 20.2500 m
- Cell height = 2.5000 m
- Cell volume = 171.2500 m3 cv01500 lwr_plenum_2 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv015a0 3 cv015a1 pvol 1.01089e5 cv015a2 tatm 275.0 cv015a3 mlfr.4 0.2095 Appendix C 14
cv015a4 mlfr.5 0.7905 cv015a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv015b1 17.7500 0.0000 cv015b2 20.2500 171.2500
- lower plenum #3 *
- Cell number = 16
- Cell bottom = 17.7500 m
- cell top = 20.2500 m
- Cell height = 2.5000 m
- Cell volume = 171.2500 m3 cv01600 lwr_plenum_3 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv016a0 3 cv016a1 pvol 1.01089e5 cv016a2 tatm 275.0 cv016a3 mlfr.4 0.2095 cv016a4 mlfr.5 0.7905 cv016a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv016b1 17.7500 0.0000 cv016b2 20.2500 171.2500
- lower plenum #4 *
- Cell number = 17
- Cell bottom = 17.7500 m
- cell top = 20.2500 m
- Cell height = 2.5000 m
- Cell volume = 171.2500 m3 cv01700 lwr_plenum_4 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv017a0 3 cv017a1 pvol 1.01089e5 cv017a2 tatm 275.0 cv017a3 mlfr.4 0.2095 cv017a4 mlfr.5 0.7905 cv017a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv017b1 17.7500 0.0000 cv017b2 20.2500 171.2500
- ice condenser #1 *
- Cell number = 18
- Cell bottom = 20.4000 m
- cell top = 35.0000 m
- Cell height = 14.6000 m
- Cell volume = 611.0000 m3 cv01800 ice_cndnsr_1 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv01803 41.75
- flow area from contain ice condensor input cv018a0 3 cv018a1 pvol 1.00992e5 cv018a2 tatm 275.0 cv018a3 mlfr.4 0.2095 Appendix C 15
cv018a4 mlfr.5 0.7905 cv018a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv018b1 20.4000 0.0000 cv018b2 35.0000 611.0000
- ice condenser #2 *
- Cell number = 19
- Cell bottom = 20.4000 m
- cell top = 35.0000 m
- Cell height = 14.6000 m
- Cell volume = 611.0000 m3 cv01900 ice_cndnsr_2 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv01903 41.75
- flow area from contain ice condensor input cv019a0 3 cv019a1 pvol 1.00992e5 cv019a2 tatm 275.0 cv019a3 mlfr.4 0.2095 cv019a4 mlfr.5 0.7905 cv019a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv019b1 20.4000 0.0000 cv019b2 35.0000 611.0000
- ice condenser #3 *
- Cell number = 20
- Cell bottom = 20.4000 m
- cell top = 35.0000 m
- Cell height = 14.6000 m
- Cell volume = 611.0000 m3 cv02000 ice_cndnsr_3 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv02003 41.75
- flow area from contain ice condensor input cv020a0 3 cv020a1 pvol 1.00992e5 cv020a2 tatm 275.0 cv020a3 mlfr.4 0.2095 cv020a4 mlfr.5 0.7905 cv020a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv020b1 20.4000 0.0000 cv020b2 35.0000 611.0000
- ice condenser #4 *
- Cell number = 21
- Cell bottom = 20.4000 m
- cell top = 35.0000 m
- Cell height = 14.6000 m
- Cell volume = 611.0000 m3 cv02100 ice_cndnsr_4 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv02103 41.75
- flow area from contain ice condensor input Appendix C 16
cv021a0 3 cv021a1 pvol 1.00992e5 cv021a2 tatm 275.0 cv021a3 mlfr.4 0.2095 cv021a4 mlfr.5 0.7905 cv021a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv021b1 20.4000 0.0000 cv021b2 35.0000 611.0000
- upper plenum #1 *
- Cell number = 22
- Cell bottom = 35.1000 m
- cell top = 40.1000 m
- Cell height = 5.0000 m
- Cell volume = 665.0000 m3 cv02200 upp_plenum_1 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv022a0 3 cv022a1 pvol 1.00883e5 cv022a2 tatm 275.0 cv022a3 mlfr.4 0.2095 cv022a4 mlfr.5 0.7905 cv022a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv022b1 35.1000 0.0000 cv022b2 40.1000 665.0000
- upper plenum #2 *
- Cell number = 23
- Cell bottom = 35.1000 m
- cell top = 40.1000 m
- Cell height = 5.0000 m
- Cell volume = 665.0000 m3 cv02300 upp_plenum_2 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv023a0 3 cv023a1 pvol 1.00883e5 cv023a2 tatm 275.0 cv023a3 mlfr.4 0.2095 cv023a4 mlfr.5 0.7905 cv023a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv023b1 35.1000 0.0000 cv023b2 40.1000 665.0000
- upper dome region #1 *
- Cell number = 24
- Cell bottom = 33.7000 m
- cell top = 54.7000 m
- Cell height = 21.0000 m
- Cell volume =6387. m3 cv02400 upp_dome_1 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv024a0 3 cv024a1 pvol 1.00810e5 cv024a2 tatm 303.
Appendix C 17
cv024a3 mlfr.4 0.2095 cv024a4 mlfr.5 0.7905 cv024a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv024b2 33.7000 0.0000 cv024b3 54.7000 6387.0000
- upper dome region #2 *
- Cell number = 25
- Cell bottom = 33.7000 m
- cell top = 54.7000 m
- Cell height = 21.0000 m
- Cell volume =6387. m3 cv02500 upp_dome_2 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv025a0 3 cv025a1 pvol 1.00810e5 cv025a2 tatm 303.
cv025a3 mlfr.4 0.2095 cv025a4 mlfr.5 0.7905 cv025a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv025b1 33.7000 0.0000 cv025b2 54.7000 6387.0000
- lower dome region *
- Cell number = 26
- Cell bottom = 17.9000 m
- cell top = 34.1000 m
- Cell height = 16.2000 m
- Cell volume = 5852. m3 cv02600 lwr_dome 2 2 4
- Non-Equ Thermo, Vert Flow, Ctmt cv026a0 3 cv026a1 pvol 1.00989e5 cv026a2 tatm 303.
cv026a3 mlfr.4 0.2095 cv026a4 mlfr.5 0.7905 cv026a5 rhum 0.30
- relative humidity 30% per FSAR Table 6-1 cv026b1 6.48 0.0000 cv026b2 8.53 430.0 cv026b3 34.1000 5852.0000
- Note: CONTAIN Cell 27 was dummy primary system cell to hold blowdown *
- steam and hydrogen sources. Not converted for MELCOR *
- environment *
- Cell number = 28
- Cell bottom = 0. m
- cell top = 1.e02 m
- Cell height = 1.e02 m
- Cell volume = 1.e03 m3 Appendix C 18
cv02800 ENVIRONMENT 2 2 99
- NON-EQU THERMO, VERT FLOW, ENVIRON cv02801 0 -1 cv028a0 3 cv028a1 pvol 1.00e5 cv028a2 tatm 303.
cv028a3 mlfr.4 0.2095 cv028a4 mlfr.5 0.7905 cv028b1 -1.e01 0.0000 cv028b2 5.e01 1.e03
- environment *
- Cell number = 29
- Cell bottom = 0. m
- cell top = 1.e02 m
- Cell height = 1.e02 m
- Cell volume = 1.e03 m3 cv02900 ENVIRONMENT 2 2 97
- NON-EQU THERMO, VERT FLOW, ENVIRON cv02901 0 -1 cv029a0 3 cv029a1 pvol 1.00e5 cv029a2 tatm 303.
cv029a3 mlfr.4 0.2095 cv029a4 mlfr.5 0.7905 cv029b1 -1.e01 0.0000 cv029b2 5.e01 1.e03 cf15200 peak-dome max 2 1.
cf15201 0.0 cf15210 1.0 0.0 cvh-p.024 cf15211 1.0 0.0 cfvalu.152
- FL Input (from CONTAIN standard flow paths) *
- reactor vessel annulus *
- Flow path number = 1
- Flow area = 1.0000 m2
- Area/length ratio =.1000 m
- Flow coefficient = 4.0000 (Cfc = 0.5
- k)
- From cell = 1
- To cell = 6 fl00100 rx-annulus 1 6 2.97 12.97
- fm,to elev fl00101 1.0000 10.0000 1.0000
- area, length, frac open fl00103 8.00 8.00
- k(forward),k(reverse) fl001s1 1.0000 10.0000 0.56
- area,length,shyd (segment)
- cavity to lower compartment *
- Flow path number = 2
- Flow area = 3.3000 m2 Appendix C 19
- Area/length ratio = 1.4300 m
- Flow coefficient = 1.0000
- From cell = 1
- To cell = 9 fl00200 cav-to-lc 1 9 3.52 8.53
- fm,to elev fl00201 3.3000 2.3077 1.0000
- area, length, frac open fl00203 2.00 2.00
- k(forward),k(reverse) fl002s1 3.3000 2.3077 1.025
- area,length,shyd (segment)
- Note: From elevation changed from 8.53 to 3.52 so it fits in CV1
- seal table *
- Flow path number = 3
- Flow area = 1.8000 m2
- Area/length ratio = 1.4000 m
- Flow coefficient = 1.0000
- From cell = 1
- To cell = 12
- fl00300 seal-table 1 12 3.52 10.27
- fm,to elev
- fl00301 1.8000 1.2857 0.0000
- area, length, frac open
- fl00303 2.00 2.00
- k(forward),k(reverse)
- fl003s1 1.8000 1.2857 0.757
- area,length,shyd (segment)
- fl003v1 -1 905 905
- cf905 defines fraction open
- Note: From elevation changed from 10.27 to 3.52 so it fits in CV1
- contain input specifies that this path is closed initially, and opens if
- the dp across the flow path is >10 MPa (either positive or negative). once
- the flow path is open, it remains open. the cf below takes care of this.
- cf90500 'seal-tab-fo' l-a-ifte 3 1.0 0.0
- cf90510 1.0 0.0 cfvalu.904
- if cf392 = true, then
- cf90511 0.0 1.0 time
- fraction open is 1.0, otherwise
- cf90512 0.0 0.0 time
- fraction open is 0.0
- cf90400 'dp check' l-or 2 1.0 0.0
- cf90401.FALSE.
- cf90405 latch
- always true after change
- cf90410 1.0 0.0 cfvalu.903
- dp(cv12-cv1) > 1.e7 pa
- cf90411 1.0 0.0 cfvalu.902
- dp(cv1-cv12) > 1.e7 pa
- cf90300 'dp_cv1-12' l-gt 2 1.0 0.0
- cf90310 1.0 0.0 cfvalu.901
- cf90311 0.0 1.0e7 time
- cf90200 'dp_cv12-1' l-gt 2 1.0 0.0
- cf90210 1.0 0.0 cfvalu.900
- cf90211 0.0 1.0e7 time
- cf90100 'cv1-12_dp' add 2 1.0 0.0
- cf90110 1.0 0.0 cvh-p.001
- cf90111 -1.0 0.0 cvh-p.012
- cf90000 'cv12-1_dp' add 2 1.0 0.0
- cf90010 1.0 0.0 cvh-p.012 Appendix C 20
- cf90011 -1.0 0.0 cvh-p.001
- intra-doghouse connection *
- Flow path number = 5
- Flow area = 16.5000 m2
- Area/length ratio = 5.0000 m
- Flow coefficient =.7000
- From cell = 2
- To cell = 3 fl00500 intra-dogh 2 3 32.00 32.00
- fm,to elev fl00501 16.500 3.3000 1.0000
- area, length, frac open fl00503 1.40 1.40
- k(forward),k(reverse) fl005s1 16.500 3.3000 2.292
- area,length,shyd (segment)
- sgd1 to lower containment *
- Flow path number = 6
- Flow area = 16.0000 m2
- Area/length ratio = 3.1000 m
- Flow coefficient =.7100
- From cell = 2
- To cell = 8 fl00600 sgd1-lwrct 2 8 21.40 19.30
- fm,to elev fl00601 16.000 5.1610 1.0000
- area, length, frac open fl00603 1.42 1.42
- k(forward),k(reverse) fl006s1 16.000 5.1610 2.257
- area,length,shyd (segment)
- Note: From elevation changed from 20.0 to 21.4 so it fits in CV2
- Note: To elevation changed from 20.0 to 19.3 so it fits in CV8
- sgd2 to lower containment *
- Flow path number = 7
- Flow area = 16.0000 m2
- Area/length ratio = 3.1000 m
- Flow coefficient =.6900
- From cell = 3
- To cell = 8 fl00700 sgd2-lwrct 3 8 21.40 19.30
- fm,to elev fl00701 16.000 5.1610 1.0000
- area, length, frac open fl00703 1.38 1.38
- k(forward),k(reverse) fl007s1 16.000 5.1610 2.257
- area,length,shyd (segment)
- Note: From elevation changed from 20.0 to 21.4 so it fits in CV3
- Note: To elevation changed from 20.0 to 19.3 so it fits in CV8
- intra-doghouse connection *
- Flow path number = 8
- Flow area = 16.5000 m2
- Area/length ratio = 5.0000 m
- Flow coefficient =.7000
- From cell = 4 Appendix C 21
- To cell = 5 fl00800 intra-dogh 4 5 32.00 32.00
- fm,to elev fl00801 16.500 3.3000 1.0000
- area, length, frac open fl00803 1.40 1.40
- k(forward),k(reverse) fl008s1 16.500 3.3000 2.292
- area,length,shyd (segment)
- sgd3 to lower containment *
- Flow path number = 9
- Flow area = 16.0000 m2
- Area/length ratio = 3.1000 m
- Flow coefficient =.7100
- From cell = 4
- To cell = 10 fl00900 sgd3-lwrct 4 10 21.40 19.30
- fm,to elev fl00901 16.000 5.1610 1.0000
- area, length, frac open fl00903 1.42 1.42
- k(forward),k(reverse) fl009s1 16.000 5.1610 2.257
- area,length,shyd (segment)
- Note: From elevation changed from 20.0 to 21.4 so it fits in CV4
- Note: To elevation changed from 20.0 to 19.3 so it fits in CV10
- sgd4 to lower containment *
- Flow path number = 10
- Flow area = 16.0000 m2
- Area/length ratio = 3.1000 m
- Flow coefficient =.6900
- From cell = 5
- To cell = 10 fl01000 sgd4-lwrct 5 10 21.40 19.30
- fm,to elev fl01001 16.000 5.1610 1.0000
- area, length, frac open fl01003 1.38 1.38
- k(forward),k(reverse) fl010s1 16.000 5.1610 2.257
- area,length,shyd (segment)
- Note: From elevation changed from 20.0 to 21.4 so it fits in CV5
- Note: To elevation changed from 20.0 to 19.3 so it fits in CV10
- upper cavity to lower containment 1 *
- Flow path number = 11
- Flow area = 7.5000 m2
- Area/length ratio = 6.7000 m
- Flow coefficient = 2.0000
- From cell = 6
- To cell = 8 fl01100 ucav-lwrct 6 8 19.50 19.30
- fm,to elev fl01101 7.5000 1.1194 1.0000
- area, length, frac open fl01103 4.00 4.00
- k(forward),k(reverse) fl011s1 7.5000 1.1194 1.545
- area,length,shyd (segment)
- Note: To elevation changed from 19.5 to 19.3 so it fits in CV8
- upper cavity to lower containment 2
- Appendix C 22
- Flow path number = 12
- Flow area = 7.4000 m2
- Area/length ratio = 6.7000 m
- Flow coefficient = 2.0000
- From cell = 6
- To cell = 9 fl01200 ucav-lwrct 6 9 19.50 19.30
- fm,to elev fl01201 7.4000 1.1045 1.0000
- area, length, frac open fl01203 4.00 4.00
- k(forward),k(reverse) fl012s1 7.4000 1.1045 1.535
- area,length,shyd (segment)
- Note: To elevation changed from 19.5 to 19.3 so it fits in CV9
- upper cavity to lower containment 3 *
- Flow path number = 13
- Flow area = 7.4000 m2
- Area/length ratio = 6.7000 m
- Flow coefficient = 2.0000
- From cell = 6
- To cell = 10 fl01300 ucav-lwrct 6 10 19.50 19.30
- fm,to elev fl01301 7.4000 1.1045 1.0000
- area, length, frac open fl01303 4.00 4.00
- k(forward),k(reverse) fl013s1 7.4000 1.1045 1.535
- area,length,shyd (segment)
- Note: To elevation changed from 19.5 to 19.3 so it fits in CV10
- pressurizer doghouse to lower containment *
- Flow path number = 14
- Flow area = 8.6000 m2
- Area/length ratio = 1.5000 m
- Flow coefficient =.7000
- From cell = 7
- To cell = 9 fl01400 pdog-lwrct 7 9 21.40 19.30
- fm,to elev fl01401 8.6000 5.7333 1.0000
- area, length, frac open fl01403 1.40 1.40
- k(forward),k(reverse) fl014s1 8.6000 5.7333 1.655
- area,length,shyd (segment)
- Note: From elevation changed from 20.0 to 21.4 so it fits in CV7
- Note: To elevation changed from 20.0 to 19.3 so it fits in CV9
- lower containment 1-2 *
- Flow path number = 15
- Flow area = 23.5000 m2
- Area/length ratio = 1.5000 m
- Flow coefficient =.7000
- From cell = 8
- To cell = 9 fl01500 lwrct1-2 8 9 10.60 10.60
- fm,to elev fl01501 23.500 15.6667 1.0 100.0 100.0
- area, length, frac open, liq flow Appendix C 23
fl01503 1.40 1.40
- k(forward),k(reverse) fl01505 0.1 fl015s1 23.500 15.6667 2.735
- area,length,shyd (segment) fl0150f 5.3 12.3 fl0150t 5.3 12.3
- lower containment 1-3 *
- Flow path number = 16
- Flow area = 9.0000 m2
- Area/length ratio = 2.0000 m
- Flow coefficient = 1.0000
- From cell = 8
- To cell = 10 fl01600 lwrct1-3 8 10 5.30 5.30
- fm,to elev fl01601 9.0000 4.5000 1.0
- area, length, frac open fl01603 2.00 2.00
- k(forward),k(reverse) fl01605 0.01 fl016s1 9.0000 4.5000 1.693
- area,length,shyd (segment) fl0160f 5.30 5.3 fl0160t 5.30 5.32
- Note: From elevation changed from 5.0 to 5.3 so it fits in CV8
- Note: To elevation changed from 5.0 to 5.3 so it fits in CV10
- This represented an "under slab" pathway across the containment.
- The opening height was reduced accordingly.
- lower containment 1 to lower annulus 1 *
- Flow path number = 17
- Flow area = 4.5000 m2
- Area/length ratio =.7500 m
- Flow coefficient =.7000
- From cell = 8
- To cell = 11 fl01700 lwrct-ann1 8 11 11.55 11.55
- fm,to elev fl01701 4.5000 6.0000 1.0
- area, length, frac open, liq flow fl01703 1.40 1.40
- k(forward),k(reverse) fl01705 0.1 fl017s1 4.5000 6.0000 1.197
- area,length,shyd (segment)
- lower containment 1 to dome (deck bypass leakage) *
- Flow path number = 18
- Flow area =.0967 m2
- Area/length ratio =.1610 m
- Flow coefficient = 1.2500
- From cell = 8
- To cell = 26 fl01800 deck-leakg 8 26 19.30 20.92
- fm,to elev fl01801 0.0967 0.6006 1.0000
- area, length, frac open fl01803 2.50 2.50
- k(forward),k(reverse)
Appendix C 24
fl018s1 0.0967 0.6006 0.175
- area,length,shyd (segment)
- Note: From elevation changed from 20.32 to 19.3 so it fits in CV8
- lower containment 2-3 *
- Flow path number = 19
- Flow area = 23.5000 m2
- Area/length ratio = 1.5000 m
- Flow coefficient =.7000
- From cell = 9
- To cell = 10 fl01900 lwrct2-3 9 10 10.60 10.60
- fm,to elev fl01901 23.500 15.6667 1.0 100.0 100.0
- area, length, frac open, liq flow fl01903 1.40 1.40
- k(forward),k(reverse) fl01905 0.1 fl019s1 23.500 15.6667 2.735
- area,length,shyd (segment) fl0190f 5.3 12.3 fl0190t 5.3 12.3
- lower containment 2 to lower annulus 2 *
- Flow path number = 20
- Flow area = 4.4000 m2
- Area/length ratio =.7500 m
- Flow coefficient =.7000
- From cell = 9
- To cell = 12 fl02000 lwrc-ann2 9 12 11.55 11.55
- fm,to elev fl02001 4.4000 5.8667 1.0000
- area, length, frac open fl02003 1.40 1.40
- k(forward),k(reverse) fl020s1 4.4000 5.8667 1.183
- area,length,shyd (segment) fl0200f 5.3 12.3
- jlt (equal liquid levels in lower containment) fl0200t 5.3 12.3
- jlt ( same )
- lower containment 2 to dome (deck bypass leakage) *
- Flow path number = 21
- Flow area =.0967 m2
- Area/length ratio =.1610 m
- Flow coefficient = 1.2500
- From cell = 9
- To cell = 26 fl02100 deck-leakg 9 26 19.30 20.92
- fm,to elev fl02101 0.0967 0.6006 1.0000
- area, length, frac open fl02103 2.50 2.50
- k(forward),k(reverse) fl021s1 0.0967 0.6006 0.175
- area,length,shyd (segment)
- Note: From elevation changed from 20.32 to 19.3 so it fits in CV9
- lower containment 3 to lower annulus 3
- Appendix C 25
- Flow path number = 22
- Flow area = 4.9500 m2
- Area/length ratio =.7500 m
- Flow coefficient =.7000
- From cell = 10
- To cell = 13 fl02200 lwrc-ann3 10 13 11.55 11.55
- fm,to elev fl02201 4.9500 6.6000 1.0000
- area, length, frac open fl02203 1.40 1.40
- k(forward),k(reverse) fl022s1 4.9500 6.6000 1.255
- area,length,shyd (segment) fl0220f 5.3 12.3
- jlt (equal liquid levels in lower containment) fl0220t 5.3 12.3
- jlt ( same )
- lower containment 3 to dome (deck bypass leakage) *
- Flow path number = 23
- Flow area =.0967 m2
- Area/length ratio =.1610 m
- Flow coefficient = 1.2500
- From cell = 10
- To cell = 26 fl02300 deck-leakg 10 26 19.30 20.92
- fm,to elev fl02301 0.0967 0.6006 1.0000
- area, length, frac open fl02303 2.50 2.50
- k(forward),k(reverse) fl023s1 0.0967 0.6006 0.175
- area,length,shyd (segment)
- Note: From elevation changed from 20.32 to 19.3 so it fits in CV10
- lower annulus 1 to 2 *
- Flow path number = 24
- Flow area = 1.5000 m2
- Area/length ratio =.6700 m
- Flow coefficient = 1.0000
- From cell = 11
- To cell = 12 fl02400 lwrann1-2 11 12 12.30 12.30
- fm,to elev fl02401 1.5000 2.2390 1.0000
- area, length, frac open fl02403 2.00 2.00
- k(forward),k(reverse) fl02405 0.01
- Maximize slip fl024s1 1.5000 2.2390 0.175
- area,length,shyd (segment) fl0240f 5.3000 19.3000 fl0240t 5.3000 19.3000
- lower annulus 2 to 3 *
- Flow path number = 25
- Flow area = 1.5000 m2
- Area/length ratio =.6700 m
- Flow coefficient = 1.0000
- From cell = 12
- To cell = 13 Appendix C 26
fl02500 lwrann2-3 12 13 12.30 12.30
- fm,to elev fl02501 1.5000 2.2390 1.0000
- area, length, frac open fl02503 2.00 2.00
- k(forward),k(reverse) fl02505 0.01
- Maximize slip fl025s1 1.5000 2.2390 0.175
- area,length,shyd (segment) fl0250f 5.3000 19.3000 fl0250t 5.3000 19.3000
- lower plenum 1 to 2 *
- Flow path number = 26
- Flow area = 2.1000 m2
- Area/length ratio =.7700 m
- Flow coefficient = 1.5000
- From cell = 14
- To cell = 15 fl02600 lwrplen1-2 14 15 19.00 19.00
- fm,to elev fl02601 2.1000 2.7270 1.0 100.0 100.0
- area, length, frac open, allow liq flow fl02603 3.00 3.00
- k(forward),k(reverse) fl02605 0.1
- allow slip for drainage to pool fl026s1 2.1000 2.7270 0.818
- area,length,shyd (segment)
- lower plenum 1 to ice chest 1 *
- Flow path number = 27
- Flow area = 22.9000 m2
- Area/length ratio = 2.6800 m
- Flow coefficient =.7000
- From cell = 14
- To cell = 18 fl02700 lwrplen-ic1 14 18 20.25 20.41
- fm,to elev fl02701 22.900 8.5448 1.0000
- area, length, frac open fl02703 1.40 1.40
- k(forward),k(reverse) fl02705 0.1
- allow slip for drainage to pool fl027s1 22.900 8.5448 2.700
- area,length,shyd (segment)
- fl0270f 20.00 20.25
- fl0270t 20.41 35.0
- Note: From elevation changed from 20.40 to 20.25 so it fits in CV14
- lower plenum 2 to 3 *
- Flow path number = 28
- Flow area = 2.1000 m2
- Area/length ratio =.7700 m
- Flow coefficient = 1.5000
- From cell = 15
- To cell = 16 fl02800 lwrplen2-3 15 16 19.00 19.00
- fm,to elev fl02801 2.1000 2.7270 1.0 100.0 100.0
- area, length, frac open -
Allow liq flow Appendix C 27
fl02803 3.00 3.00
- k(forward),k(reverse) fl02805 0.1
- allow slip for drainage to pool fl028s1 2.1000 2.7270 0.818
- area,length,shyd (segment)
- lower plenum 2 to ice chest 2 *
- Flow path number = 29
- Flow area = 22.9000 m2
- Area/length ratio = 2.6800 m
- Flow coefficient =.7000
- From cell = 15
- To cell = 19 fl02900 lwrplen-ic2 15 19 20.25 20.41
- fm,to elev fl02901 22.900 8.5448 1.0000
- area, length, frac open fl02903 1.40 1.40
- k(forward),k(reverse) fl02905 0.1
- allow slip for drainage to pool fl029s1 22.900 8.5448 2.700
- area,length,shyd (segment)
- fl0290f 20.00 20.25
- fl0290t 20.41 35.0
- Note: From elevation changed from 20.40 to 20.25 so it fits in CV15
- lower plenum 3 to 4 *
- Flow path number = 30
- Flow area = 2.1000 m2
- Area/length ratio =.7700 m
- Flow coefficient = 1.5000
- From cell = 16
- To cell = 17 fl03000 lwrplen3-4 16 17 19.00 19.00
- fm,to elev fl03001 2.1000 2.7270 1.0 100.0 100.0
- area, length, frac open, allow liq flow fl03003 3.00 3.00
- k(forward),k(reverse) fl03005 0.1
- allow slip for drainage to pool fl030s1 2.1000 2.7270 0.818
- area,length,shyd (segment)
- lower plenum 3 to ice chest 3 *
- Flow path number = 31
- Flow area = 22.9000 m2
- Area/length ratio = 2.6800 m
- Flow coefficient =.7000
- From cell = 16
- To cell = 20 fl03100 lwrplen-ic3 16 20 20.25 20.41
- fm,to elev fl03101 22.900 8.5448 1.0000
- area, length, frac open fl03103 1.40 1.40
- k(forward),k(reverse) fl03105 0.1
- allow slip for drainage to pool fl031s1 22.900 8.5448 2.700
- area,length,shyd (segment)
- fl0310f 20.00 20.25 Appendix C 28
- fl0310t 20.41 35.0
- Note: From elevation changed from 20.40 to 20.25 so it fits in CV16
- lower plenum 4 to ice chest 4 *
- Flow path number = 32
- Flow area = 22.9000 m2
- Area/length ratio = 2.6800 m
- Flow coefficient =.7000
- From cell = 17
- To cell = 21 fl03200 lwrplen-ic4 17 21 20.25 20.41
- fm,to elev fl03201 22.900 8.5448 1.0000
- area, length, frac open fl03203 1.40 1.40
- k(forward),k(reverse) fl03205 0.01
- allow slip for drainage to pool fl032s1 22.900 8.5448 2.700
- area,length,shyd (segment)
- fl0320f 20.00 20.25
- fl0320t 20.41 35.0
- Note: From elevation changed from 20.40 to 20.25 so it fits in CV17
- ice chest 1 to ice chest 2 *
- Flow path number = 33
- Flow area = 3.9500 m2
- Area/length ratio = 1.2500 m
- Flow coefficient = 1.5000
- From cell = 18
- To cell = 19 fl03300 icechest1-2 18 19 24.05 24.05
- fm,to elev fl03301 3.9500 3.1600 1.0000
- area, length, frac open fl03303 3.00 3.00
- k(forward),k(reverse) fl033s1 3.9500 3.1600 1.121
- area,length,shyd (segment)
- ice chest 1 to upper plenum 1 (intermediate doors) *
- Flow path number = 34
- Flow area =.0000 m2
- Area/length ratio = 1.7900 m
- Flow coefficient =.7000
- From cell = 18
- To cell = 22 fl03400 interdoors1 18 22 35.00 35.10
- fm,to elev fl03401 17.560 9.8100 0.0
- area, length, frac open fl03403 1.40 1.40
- k(forward),k(reverse) fl03405 0.01
- max slip fl034s1 17.560 9.8100 2.364
- area,length,shyd (segment) fl034v1 -1 922 922
- Note: To elevation changed from 35.00 to 35.10 so it fits in CV22 cf92200 'Mid_Door1' add 2 0.1 0.0 cf92210 9.0 0.0 cfvalu.922 cf92211 1.0 0.0 cfvalu.921 Appendix C 29
cf92100 'door-p' tab-fun 1 1.0 0.0
- cf92101 0.02648 cf92103 921 cf92110 1.0 0.0 cfvalu.920 tf92100 'door-p' 4 1.0 0.0 tf92111 -1.e7 0.02648 tf92112 263.0 0.02648 tf92113 28498.0 1.0 tf92114 1.e7 1.0 cf92000 'dp 18-22' add 3 1.0 0.0 cf92010 1.0 0.0 cvh-p.018 cf92011 -1.0 0.0 cvh-p.022 cf92012 -143.2 0.0 cvh-rhoa.018
- rho*g*h (g*h = 9.81*(35.0-20.4))
- ice chest 2 to ice chest 3 *
- Flow path number = 35
- Flow area = 3.9500 m2
- Area/length ratio = 1.2500 m
- Flow coefficient = 1.5000
- From cell = 19
- To cell = 20 fl03500 icechest2-3 19 20 24.05 24.05
- fm,to elev fl03501 3.9500 3.1600 1.0000
- area, length, frac open fl03503 3.00 3.00
- k(forward),k(reverse) fl035s1 3.9500 3.1600 1.121
- area,length,shyd (segment)
- ice chest 2 to upper plenum 1 (intermediate doors) *
- Flow path number = 36
- Flow area =.0000 m2
- Area/length ratio = 1.7900 m
- Flow coefficient =.7000
- From cell = 19
- To cell = 22 fl03600 interdoors2 19 22 35.00 35.10
- fm,to elev fl03601 17.560 9.8100 0.0
- area, length, frac open fl03603 1.40 1.40
- k(forward),k(reverse) fl03605 0.01
- max slip fl036s1 17.560 9.8100 2.364
- area,length,shyd (segment) fl036v1 -1 925 925
- Note: To elevation changed from 35.00 to 35.10 so it fits in CV22 cf92500 'Mid_Door2' add 2 0.1 0.0 cf92510 9.0 0.0 cfvalu.925 cf92511 1.0 0.0 cfvalu.924 cf92400 'door-p' tab-fun 1 1.0 0.0
- cf92401 0.02648 cf92403 921 cf92410 1.0 0.0 cfvalu.923 Appendix C 30
cf92300 'dp 19-22' add 3 1.0 0.0 cf92310 1.0 0.0 cvh-p.019 cf92311 -1.0 0.0 cvh-p.022 cf92312 -143.2 0.0 cvh-rhoa.019
- rho*g*h (g*h = 9.81*(35.0-20.4))
- ice chest 3 to ice chest 4 *
- Flow path number = 37
- Flow area = 3.9500 m2
- Area/length ratio = 1.2500 m
- Flow coefficient = 1.5000
- From cell = 20
- To cell = 21 fl03700 icechest3-4 20 21 24.05 24.05
- fm,to elev fl03701 3.9500 3.1600 1.0000
- area, length, frac open fl03703 3.00 3.00
- k(forward),k(reverse) fl037s1 3.9500 3.1600 1.121
- area,length,shyd (segment)
- ice chest 3 to upper plenum 2 (intermediate doors) *
- Flow path number = 38
- Flow area =.0000 m2
- Area/length ratio = 1.7900 m
- Flow coefficient =.7000
- From cell = 20
- To cell = 23 fl03800 interdoors3 20 23 35.00 35.10
- fm,to elev fl03801 17.560 9.8100 0.0
- area, length, frac open fl03803 1.40 1.40
- k(forward),k(reverse) fl03805 0.01
- max slip fl038s1 17.560 9.8100 2.364
- area,length,shyd (segment) fl038v1 -1 928 928
- Note: To elevation changed from 35.00 to 35.10 so it fits in CV23 cf92800 'Mid_Door3' add 2 0.1 0.0 cf92810 9.0 0.0 cfvalu.928 cf92811 1.0 0.0 cfvalu.927 cf92700 'door-p' tab-fun 1 1.0 0.0
- cf92701 0.02648 cf92703 921 cf92710 1.0 0.0 cfvalu.926 cf92600 'dp 20-23' add 3 1.0 0.0 cf92610 1.0 0.0 cvh-p.020 cf92611 -1.0 0.0 cvh-p.023 cf92612 -143.2 0.0 cvh-rhoa.020
- rho*g*h (g*h = 9.81*(35.0-20.4))
- ice chest 4 to upper plenum 2 (intermediate doors) *
- Flow path number = 39
- Flow area =.0000 m2
- Area/length ratio = 1.7900 m
- Flow coefficient =.7000 Appendix C 31
- From cell = 21
- To cell = 23 fl03900 interdoors4 21 23 35.00 35.10
- fm,to elev fl03901 17.560 9.8100 0.0
- area, length, frac open fl03903 1.40 1.40
- k(forward),k(reverse) fl03905 0.01
- max slip fl039s1 17.560 9.8100 2.364
- area,length,shyd (segment) fl039v1 -1 931 931
- Note: To elevation changed from 35.00 to 35.10 so it fits in CV23 cf93100 'Mid_Door4' add 2 0.1 0.0 cf93110 9.0 0.0 cfvalu.931 cf93111 1.0 0.0 cfvalu.930 cf93000 'door-p' tab-fun 1 1.0 0.0
- cf93001 0.02648 cf93003 921 cf93010 1.0 0.0 cfvalu.929 cf92900 'dp 21-23' add 3 1.0 0.0 cf92910 1.0 0.0 cvh-p.021 cf92911 -1.0 0.0 cvh-p.023 cf92912 -143.2 0.0 cvh-rhoa.021
- rho*g*h (g*h = 9.81*(35.0-20.4))
- upper plenum 1 to 2 *
- Flow path number = 40
- Flow area = 6.2000 m2
- Area/length ratio = 1.0000 m
- Flow coefficient =.7000
- From cell = 22
- To cell = 23 fl04000 upplen1-2 22 23 36.30 36.30
- fm,to elev fl04001 6.2000 6.2000 1.0
- area, length, frac open fl04003 1.40 1.40
- k(forward),k(reverse) fl040s1 6.2000 6.2000 1.405
- area,length,shyd (segment)
- upper plenum 1 to dome 1 (upper doors) *
- Flow path number = 41
- Flow area =.0000 m2
- Area/length ratio = 4.7000 m
- Flow coefficient =.7000
- From cell = 22
- To cell = 24 fl04100 upperdoors1 22 24 40.10 40.20
- fm,to elev fl04101 46.950 9.9894 0.01981
- area, length, frac open fl04103 1.40 1.40
- k(forward),k(reverse) fl041s1 46.950 9.9894 3.866
- area,length,shyd (segment) fl041v1 -1 934 934
- Note: From elevation changed from 40.20 to 40.10 so it fits in CV22 cf93400 'Up_Door1' add 2 0.1 0.0 cf93410 9.0 0.0 cfvalu.934 Appendix C 32
cf93411 1.0 0.0 cfvalu.933 cf93300 'door-p' tab-fun 1 1.0 0.0
- cf93301 0.01981 cf93303 933 cf93310 1.0 0.0 cfvalu.932 tf93300 'door-p' 4 1.0 0.0 tf93311 -1.e7 0.01981 tf93312 263.0 0.01981 tf93313 4441.0 1.0 tf93314 1.e7 1.0 cf93200 'dp 22-24' add 3 1.0 0.0 cf93210 1.0 0.0 cvh-p.022 cf93211 -1.0 0.0 cvh-p.024 cf93212 -49.1 0.0 cvh-rhoa.022
- rho*g*h (g*h = 9.81*(40.1-35.1))
- upper plenum 2 to dome 2 (upper doors) *
- Flow path number = 42
- Flow area =.0000 m2
- Area/length ratio = 4.7000 m
- Flow coefficient =.7000
- From cell = 23
- To cell = 25 fl04200 upperdoors2 23 25 40.10 40.20
- fm,to elev fl04201 46.950 9.9894 0.01981
- area, length, frac open fl04203 1.40 1.40
- k(forward),k(reverse) fl042s1 46.950 9.9894 3.866
- area,length,shyd (segment) fl042v1 -1 937 937
- Note: From elevation changed from 40.20 to 40.10 so it fits in CV23 cf93700 'Up_Door2' add 2 0.1 0.0 cf93710 9.0 0.0 cfvalu.937 cf93711 1.0 0.0 cfvalu.936 cf93600 'door-p' tab-fun 1 1.0 0.0
- cf93601 0.01981 cf93603 933 cf93610 1.0 0.0 cfvalu.935 cf93500 'dp 23-25' add 3 1.0 0.0 cf93510 1.0 0.0 cvh-p.023 cf93511 -1.0 0.0 cvh-p.025 cf93512 -49.1 0.0 cvh-rhoa.023
- rho*g*h (g*h = 9.81*(40.1-35.1))
- dome 1 to dome 2 *
- Flow path number = 43
- Flow area = 296.5000 m2
- Area/length ratio = 16.7000 m
- Flow coefficient =.7000
- From cell = 24
- To cell = 25 fl04300 dome1-2 24 25 39.90 39.90
- fm,to elev Appendix C 33
fl04301 296.50 17.7545 1.0
- area, length, frac open fl04303 1.40 1.40
- k(forward),k(reverse) fl043s1 296.50 17.7545 9.715
- area,length,shyd (segment)
- upper dome 1 to lower dome *
- Flow path number = 44
- Flow area = 182.0000 m2
- Area/length ratio = 11.1000 m
- Flow coefficient =.7000
- From cell = 24
- To cell = 26 fl04400 up-lowdome1 24 26 35.00 34.10
- fm,to elev fl04401 182.00 16.3964 1.0
- area, length, frac open fl04403 1.40 1.40
- k(forward),k(reverse) fl044s1 182.00 16.3964 7.611
- area,length,shyd (segment)
- Note: To elevation changed from 35.00 to 34.10 so it fits in CV26
- containment leak and failure *
- fl098 containment failure flow path
- The leak behaves as a critical orifce of area 0.1 m2.
fl09800 ctmt-fail 24 28 40.20 40.20
- fm,to elev fl09801 0.1000 1.0000 0.0
- area, length, frac open fl09803 1.40 1.40
- k(forward),k(reverse) fl098s1 0.1000 1.0000 7.611
- area,length,shyd (segment) fl098v1 -1 998 998 cf99800 'Failure' hyst 1 1.0 0.0 cf99803 -997 cf99804 -998 cf99810 1.0 0.0 cvh-p.24 tf99700 'load-p' 2 1.0 0.0
- Failure at 65 psia from IDCOR model tf99710 6.58e+05 0.0 tf99711 6.58e+05 1.0 tf99800 'unload' 2 1.0 0.0 tf99810 0.00e+05 1.0 tf99811 6.58e+05 1.0
- fl099 containment leakage flow path
- The leak behaves as a critical orifce of diameter 2.3 mm.
- It is actually a friction limited flow path with a variable
- area to match critical flow leakage.
fl09900 'Leakage' 024 029 40.2 40.2 fl09901 1.4e-4 1.0 1.0 fl09902 3 0 fl09903 1.75e3 1.75e3 fl099S1 1.0 1.0 1.0 1.0E-6 fl099V0 -1 999 999 cf99900 'Leakage' TAB-FUN 1 1.0 0.0 Appendix C 34
cf99903 999 cf99910 1.0 0.0 CVH-P.024 tf99900 'Pressure' 9 1.0 0.0 tf99910 1.000000E5 1.00 tf99911 1.600000E5 1.00 tf99912 1.650000E5 0.93 tf99913 2.000000E5 0.823 tf99914 2.500000E5 0.76 tf99915 3.000000E5 0.71 tf99916 4.000000E5 0.67 tf99917 5.000000E5 0.65 tf99918 6.000000E5 0.64
- upper dome 2 to lower dome *
- Flow path number = 46
- Flow area = 182.0000 m2
- Area/length ratio = 11.1000 m
- Flow coefficient =.7000
- From cell = 25
- To cell = 26 fl04600 up-lowdome2 25 26 35.00 34.10
- fm,to elev fl04601 182.00 16.3964 1.0
- area, length, frac open fl04603 1.40 1.40
- k(forward),k(reverse) fl046s1 182.00 16.3964 7.611
- area,length,shyd (segment)
- Note: To elevation changed from 35.00 to 34.10 so it fits in CV26
- FL Input (from CONTAIN engineered vents) *
- lower containment 1-2 *
- Flow path number = 47 (identical to 15 except for elevation)
- Flow area = 23.5000 m2
- Area/length ratio = 1.5000 m
- Flow coefficient =.7000
- From cell = 8
- To cell = 9 fl04700 lwrct1-2 8 9 14.00 14.00
- fm,to elev fl04701 23.500 15.6667 1.0 100.0 100.0
- area, length, frac open, liq flow fl04703 1.40 1.40
- k(forward),k(reverse) fl04705 0.1 fl047s1 23.500 15.6667 2.735
- area,length,shyd (segment) fl0470f 12.3 19.3 fl0470t 12.3 19.3
- lower containment 1 to lower annulus 1 *
- Flow path number = 48 (identical to 17 except for elevation)
- Flow area = 4.5000 m2 Appendix C 35
- Area/length ratio =.7500 m
- Flow coefficient =.7000
- From cell = 8
- To cell = 11 fl04800 lwrct-ann1 8 11 13.05 13.05
- fm,to elev fl04801 4.5000 6.0000 1.0
- area, length, frac open, liq flow fl04803 1.40 1.40
- k(forward),k(reverse) fl04805 0.1 fl048s1 4.5000 6.0000 1.197
- area,length,shyd (segment) fl0480f 12.3 19.3 fl0480t 12.3 19.3
- lower doors 1 (lower ctmt to lower plenum 1) *
- Flow path number = 49
- Flow area = 19.5100 m2
- Area/length ratio =.**** m
- Flow coefficient =.7000
- From cell = 8
- To cell = 14 fl04900 lwr-doors1 8 14 19.00 19.00
- fm,to elev fl04901 19.510 1.0000 0.0
- area, length, frac open fl04903 1.40 1.40
- k(forward),k(reverse) fl049s1 19.510 1.0000 2.492
- area,length,shyd (segment) fl049v1 -1 841 841 fl0490t 19.0 20.25 cf94000 'Low_Door1' add 2 0.1 0.0 cf94010 9.0 0.0 cfvalu.940 cf94011 1.0 0.0 cfvalu.939 cf84100 'Low_Door1_logic' l-a-ifte 3 1.0 0.0 cf84110 1.0 0.0 cfvalu.836 cf84111 0.0 1.0 time cf84112 1.0 0.0 cfvalu.940 cf93900 'door-p' tab-fun 1 1.0 0.0 cf93903 939 cf93910 1.0 0.0 cfvalu.938 tf93900 'door-p' 10 1.0 0.0 tf93911 -1.e7 0.0000518 tf93912 -14.0 0.0000518
- tf93911 -1.e7 0.0
- tf93912 -14.0 0.0 tf93913 0.0 0.0256279 tf93914 4.788 0.0333163 tf93915 9.576 0.0480779 tf93916 19.15 0.0799590 tf93917 28.73 0.2593542 tf93918 38.30 0.5720144 tf93919 46.92 1.0 tf93920 46.9201 1.0 cf93800 'dp 8-14' add 4 0.2 0.0 cf93810 1.0 0.0 cvh-p.008 cf93811 -1.0 0.0 cvh-p.014 cf93812 -122.1 0.0 cvh-rhoa.008
- rho*g*h (g*h = 9.81*(17.75-5.30))
Appendix C 36
cf93813 4.0 0.0 cfvalu.938 cf83600 'open check' l-or 2 1.0 0.0 cf83601.FALSE.
- cf83605 latch cf83610 1.0 0.0 cfvalu.835 cf83611 1.0 0.0 cfvalu.834 cf83500 'dp_cv8-cv14' l-gt 2 1.0 0.0 cf83510 1.0 0.0 cfvalu.938 cf83511 0.0 46.92 time cf83400 'open_test' l-gt 2 1.0 0.0 cf83410 1.0 0.0 cfvalu.940 cf83411 0.0 0.98 time
- lower doors 2 (lower ctmt 1 to lower plenum 2) *
- Flow path number = 50
- Flow area = 6.9800 m2
- Area/length ratio =.**** m
- Flow coefficient =.7000
- From cell = 8
- To cell = 15 fl05000 lwr-doors2 8 15 19.00 19.00
- fm,to elev fl05001 6.9800 1.0000 0.0
- area, length, frac open fl05003 1.40 1.40
- k(forward),k(reverse) fl050s1 6.9800 1.0000 1.491
- area,length,shyd (segment) fl050v1 -1 843 843 fl0500t 19.0 20.25 cf94300 'Low_Door2' add 2 0.1 0.0 cf94310 9.0 0.0 cfvalu.943 cf94311 1.0 0.0 cfvalu.942 cf84300 'Low_Door2_logic' l-a-ifte 3 1.0 0.0 cf84310 1.0 0.0 cfvalu.850 cf84311 0.0 1.0 time cf84312 1.0 0.0 cfvalu.943 cf94200 'door-p' tab-fun 1 1.0 0.0 cf94203 939 cf94210 1.0 0.0 cfvalu.941 cf94100 'dp 8-15' add 4 0.2 0.0 cf94110 1.0 0.0 cvh-p.008 cf94111 -1.0 0.0 cvh-p.015 cf94112 -122.1 0.0 cvh-rhoa.008
- rho*g*h (g*h = 9.81*(17.75-5.30))
cf94113 4.0 0.0 cfvalu.941 cf85000 'open check' l-or 2 1.0 0.0 cf85001.FALSE.
- cf85005 latch cf85010 1.0 0.0 cfvalu.855 cf85011 1.0 0.0 cfvalu.854 cf85500 'dp_cv8-cv15' l-gt 2 1.0 0.0 cf85510 1.0 0.0 cfvalu.941 cf85511 0.0 46.92 time Appendix C 37
cf85400 'open_test' l-gt 2 1.0 0.0 cf85410 1.0 0.0 cfvalu.943 cf85411 0.0 0.98 time
- refueling drain *
- Flow path number = 51
- Flow area = 0.0875 m2
- Area/length ratio =.0620 m
- Flow coefficient =.7500
- From cell = 8
- To cell = 26 fl05100 ref-drain 8 26 6.47 6.48
- fm,to elev fl05101 0.0875 1.4113 1.0000
- area, length, frac open fl05103 1.50 1.50
- k(forward),k(reverse) fl051s1 0.0875 1.4113 0.167
- area,length,shyd (segment)
- fl0510f 17.90 19.30
- fl0510t 19.00 20.00
- Note: To elevation changed from 7.89 to 17.90 so it fits in CV26
- lower containment 2-3 *
- Flow path number = 52 (identical to 19 except for elevation)
- Flow area = 23.5000 m2
- Area/length ratio = 1.5000 m
- Flow coefficient =.7000
- From cell = 9
- To cell = 10 fl05200 lwrct2-3 9 10 14.00 14.00
- fm,to elev fl05201 23.500 15.6667 1.0 100.0 100.0
- area, length, frac open, liq flow fl05203 1.40 1.40
- k(forward),k(reverse) fl05205 0.1 fl052s1 23.500 15.6667 2.735
- area,length,shyd (segment) fl0520f 12.3 19.3 fl0520t 12.3 19.3
- lower containment 2 to lower annulus 2 *
- Flow path number = 53 (identical to 20 except for elevation)
- Flow area = 4.4000 m2
- Area/length ratio =.7500 m
- Flow coefficient =.7000
- From cell = 9
- To cell = 12 fl05300 lwrc-ann2 9 12 13.05 13.05
- fm,to elev fl05301 4.4000 5.8667 1.0
- area, length, frac open fl05303 1.40 1.40
- k(forward),k(reverse) fl05305 0.1 fl053s1 4.4000 5.8667 1.183
- area,length,shyd (segment)
Appendix C 38
- lower doors 3 (lower ctmt 2 to lower plenum 2) *
- Flow path number = 54
- Flow area = 12.5100 m2
- Area/length ratio =.**** m
- Flow coefficient =.7000
- From cell = 9
- To cell = 15 fl05400 lwr-doors3 9 15 19.00 19.00
- fm,to elev fl05401 12.510 1.0000 0.0
- area, length, frac open fl05403 1.40 1.40
- k(forward),k(reverse) fl054s1 12.510 1.0000 1.996
- area,length,shyd (segment) fl054v1 -1 860 860 fl0540t 19.0 20.25 cf94600 'Low_Door3' add 2 0.1 0.0 cf94610 9.0 0.0 cfvalu.946 cf94611 1.0 0.0 cfvalu.945 cf86000 'Low_Door3_logic' l-a-ifte 3 1.0 0.0 cf86010 1.0 0.0 cfvalu.866 cf86011 0.0 1.0 time cf86012 1.0 0.0 cfvalu.946 cf94500 'door-p' tab-fun 1 1.0 0.0 cf94503 939 cf94510 1.0 0.0 cfvalu.944 cf94400 'dp 9-15' add 4 0.2 0.0 cf94410 1.0 0.0 cvh-p.009 cf94411 -1.0 0.0 cvh-p.015 cf94412 -122.1 0.0 cvh-rhoa.009
- rho*g*h (g*h = 9.81*(17.75-5.30))
cf94413 4.0 0.0 cfvalu.944 cf86600 'open check' l-or 2 1.0 0.0 cf86601.FALSE.
- cf86605 latch cf86610 1.0 0.0 cfvalu.865 cf86611 1.0 0.0 cfvalu.864 cf86500 'dp_cv9-cv15' l-gt 2 1.0 0.0 cf86510 1.0 0.0 cfvalu.944 cf86511 0.0 46.92 time cf86400 'open_test' l-gt 2 1.0 0.0 cf86410 1.0 0.0 cfvalu.946 cf86411 0.0 0.98 time
- lower doors 4 (lower ctmt 2 to lower plenum 3) *
- Flow path number = 55
- Flow area = 12.5100 m2
- Area/length ratio =.**** m
- Flow coefficient =.7000
- From cell = 9 Appendix C 39
- To cell = 16 fl05500 lwr-doors4 9 16 19.00 19.00
- fm,to elev fl05501 12.510 1.0000 0.0
- area, length, frac open fl05503 1.40 1.40
- k(forward),k(reverse) fl055s1 12.510 1.0000 1.996
- area,length,shyd (segment) fl055v1 -1 870 870 fl0550t 19.0 20.25 cf87000 'Low_Door4_logic' l-a-ifte 3 1.0 0.0 cf87010 1.0 0.0 cfvalu.876 cf87011 0.0 1.0 time cf87012 1.0 0.0 cfvalu.949 cf94900 'Low_Door4' add 2 0.1 0.0 cf94910 9.0 0.0 cfvalu.949 cf94911 1.0 0.0 cfvalu.948 cf94800 'door-p' tab-fun 1 1.0 0.0 cf94803 939 cf94810 1.0 0.0 cfvalu.947 cf94700 'dp 9-16' add 4 0.2 0.0 cf94710 1.0 0.0 cvh-p.009 cf94711 -1.0 0.0 cvh-p.016 cf94712 -122.1 0.0 cvh-rhoa.009
- rho*g*h (g*h = 9.81*(17.75-5.30))
cf94713 4.0 0.0 cfvalu.947 cf87600 'open check' l-or 2 1.0 0.0 cf87601.FALSE.
- cf87605 latch cf87610 1.0 0.0 cfvalu.875 cf87611 1.0 0.0 cfvalu.874 cf87500 'dp_cv9-cv16' l-gt 2 1.0 0.0 cf87510 1.0 0.0 cfvalu.947 cf87511 0.0 46.92 time cf87400 'open_test' l-gt 2 1.0 0.0 cf87410 1.0 0.0 cfvalu.949 cf87411 0.0 0.98 time
- lower containment 3 to lower annulus 3 *
- Flow path number = 56 (identical to 22 except for elevation)
- Flow area = 4.9500 m2
- Area/length ratio =.7500 m
- Flow coefficient =.7000
- From cell = 10
- To cell = 13 fl05600 lwrc-ann3 10 13 13.05 13.05
- fm,to elev fl05601 4.9500 6.6000 1.0
- area, length, frac open fl05603 1.40 1.40
- k(forward),k(reverse) fl05605 0.1 fl056s1 4.9500 6.6000 1.255
- area,length,shyd (segment)
- lower doors 4 (lower ctmt 3 to lower plenum 3)
- Appendix C 40
- Flow path number = 57
- Flow area = 6.9800 m2
- Area/length ratio =.**** m
- Flow coefficient =.7000
- From cell = 10
- To cell = 16 fl05700 lwr-doors5 10 16 19.00 19.00
- fm,to elev fl05701 6.9800 1.0000 0.0
- area, length, frac open fl05703 1.40 1.40
- k(forward),k(reverse) fl057s1 6.9800 1.0000 1.491
- area,length,shyd (segment) fl057v1 -1 880 880 fl0570t 19.0 20.25 cf88000 'Low_Door5_logic' l-a-ifte 3 1.0 0.0 cf88010 1.0 0.0 cfvalu.886 cf88011 0.0 1.0 time cf88012 1.0 0.0 cfvalu.952 cf95200 'Low_Door5' add 2 0.1 0.0 cf95210 9.0 0.0 cfvalu.952 cf95211 1.0 0.0 cfvalu.951 cf95100 'door-p' tab-fun 1 1.0 0.0 cf95103 939 cf95110 1.0 0.0 cfvalu.950 cf95000 'dp 10-16' add 4 0.2 0.0 cf95010 1.0 0.0 cvh-p.010 cf95011 -1.0 0.0 cvh-p.016 cf95012 -122.1 0.0 cvh-rhoa.010
- rho*g*h (g*h = 9.81*(17.75-5.30))
cf95013 4.0 0.0 cfvalu.950 cf88600 'open check' l-or 2 1.0 0.0 cf88601.FALSE.
- cf88605 latch cf88610 1.0 0.0 cfvalu.885 cf88611 1.0 0.0 cfvalu.884 cf88500 'dp_cv10-cv16' l-gt 2 1.0 0.0 cf88510 1.0 0.0 cfvalu.950 cf88511 0.0 46.92 time cf88400 'open_test' l-gt 2 1.0 0.0 cf88410 1.0 0.0 cfvalu.952 cf88411 0.0 0.98 time
- lower doors 5 (lower ctmt 3 to lower plenum 4) *
- Flow path number = 58
- Flow area = 19.5100 m2
- Area/length ratio =.**** m
- Flow coefficient =.7000
- From cell = 10
- To cell = 17 fl05800 lwr-doors6 10 17 19.00 19.00
- fm,to elev fl05801 19.510 1.0000 0.0
- area, length, frac open fl05803 1.40 1.40
- k(forward),k(reverse)
Appendix C 41
fl058s1 19.510 1.0000 2.492
- area,length,shyd (segment) fl058v1 -1 890 890 fl0580t 19.0 20.25 cf89000 'Low_Door6_logic' l-a-ifte 3 1.0 0.0 cf89010 1.0 0.0 cfvalu.896 cf89011 0.0 1.0 time cf89012 1.0 0.0 cfvalu.955 cf95500 'Low_Door6' add 2 0.1 0.0 cf95510 9.0 0.0 cfvalu.955 cf95511 1.0 0.0 cfvalu.954 cf95400 'door-p' tab-fun 1 1.0 0.0 cf95403 939 cf95410 1.0 0.0 cfvalu.953 cf95300 'dp 10-17' add 4 0.2 0.0 cf95310 1.0 0.0 cvh-p.010 cf95311 -1.0 0.0 cvh-p.017 cf95312 -122.1 0.0 cvh-rhoa.010
- rho*g*h (g*h = 9.81*(17.75-5.30))
cf95313 4.0 0.0 cfvalu.953 cf89600 'open check' l-or 2 1.0 0.0 cf89601.FALSE.
- cf89605 latch cf89610 1.0 0.0 cfvalu.895 cf89611 1.0 0.0 cfvalu.894 cf89500 'dp_cv10-cv17' l-gt 2 1.0 0.0 cf89510 1.0 0.0 cfvalu.953 cf89511 0.0 46.92 time cf89400 'open_test' l-gt 2 1.0 0.0 cf89410 1.0 0.0 cfvalu.955 cf89411 0.0 0.98 time
- refueling drain *
- Flow path number = 59
- Flow area = 0.0875 m2
- Area/length ratio =.0620 m
- Flow coefficient =.7500
- From cell = 10
- To cell = 26 fl05900 ref-drain 10 26 6.47 6.48
- fm,to elev fl05901 0.0875 1.4113 1.0000
- area, length, frac open fl05903 1.50 1.50
- k(forward),k(reverse) fl059s1 0.0875 1.4113 0.167
- area,length,shyd (segment)
- fl0590f 17.90 19.30
- fl0590t 19.00 20.00
- Note: To elevation changed from 7.89 to 17.90 so it fits in CV26
- ice chest 1 to ice chest 2
- Appendix C 42
- Flow path number = 60 (identical to 33 except for elevation)
- Flow area = 3.9500 m2
- Area/length ratio = 1.2500 m
- Flow coefficient = 1.5000
- From cell = 18
- To cell = 19 fl06000 icechest1-2 18 19 31.35 31.35
- fm,to elev fl06001 3.9500 3.1600 1.0000
- area, length, frac open fl06003 3.00 3.00
- k(forward),k(reverse) fl060s1 3.9500 3.1600 1.121
- area,length,shyd (segment)
- ice chest 1 to upper plenum 1 *
- Flow path number = 61
- Flow area = 5.6980 m2
- Area/length ratio = 0.5800 m
- Flow coefficient = 0.7000
- From cell = 18
- To cell = 22 fl06100 interdoors5 18 22 35.00 35.10
- fm,to elev fl06101 5.6980 9.8241 0.0
- area, length, frac open fl06103 1.40 1.40
- k(forward),k(reverse) fl06105 0.01
- max slip fl061s1 5.6980 9.8241 1.347
- area,length,shyd (segment) fl061v1 -1 963 963
- Note: To elevation changed from 35.00 to 35.10 so it fits in CV22 cf96300 'doorpmax' max 2 1.0 0.0 cf96301 0.0 cf96310 1.0 0.0 cfvalu.963
- this cf makes area increase cf96311 1.0 0.0 cfvalu.962
- irreversible cf96200 'door-p' tab-fun 1 1.0 0.0 cf96203 962 cf96210 1.0 0.0 cfvalu.961 tf96200 'door-p' 4 1.0 0.0 tf96211 -1.e7 0.0 tf96212 28498.0 0.0 tf96213 37910.0 1.0 tf96214 1.e7 1.0 cf96100 'dp18-22' add 2 1.0 0.0 cf96110 -1.0 0.0 cvh-p.018 cf96111 1.0 0.0 cvh-p.022
- ice chest 2 to ice chest 3 *
- Flow path number = 62 (identical to 35 except for elevation)
- Flow area = 3.9500 m2
- Area/length ratio = 1.2500 m
- Flow coefficient = 1.5000
- From cell = 19
- To cell = 20 fl06200 icechest2-3 19 20 31.35 31.35
- fm,to elev Appendix C 43
fl06201 3.9500 3.1600 1.0000
- area, length, frac open fl06203 3.00 3.00
- k(forward),k(reverse) fl062s1 3.9500 3.1600 1.121
- area,length,shyd (segment)
- ice chest 2 to upper plenum 1 *
- Flow path number = 63
- Flow area = 5.6980 m2
- Area/length ratio = 0.5800 m
- Flow coefficient = 0.7000
- From cell = 19
- To cell = 22 fl06300 interdoors6 19 22 35.00 35.10
- fm,to elev fl06301 5.6980 9.8241 0.0
- area, length, frac open fl06303 1.40 1.40
- k(forward),k(reverse) fl06305 0.01
- max slip fl063s1 5.6980 9.8241 1.347
- area,length,shyd (segment) fl063v1 -1 966 966
- Note: To elevation changed from 35.00 to 35.10 so it fits in CV22 cf96600 'doorpmax' max 2 1.0 0.0 cf96601 0.0 cf96610 1.0 0.0 cfvalu.966
- this cf makes area increase cf96611 1.0 0.0 cfvalu.965
- irreversible cf96500 'door-p' tab-fun 1 1.0 0.0 cf96503 962 cf96510 1.0 0.0 cfvalu.964 cf96400 'dp19-22' add 2 1.0 0.0 cf96410 1.0 0.0 cvh-p.019 cf96411 -1.0 0.0 cvh-p.022
- ice chest 3 to ice chest 4 *
- Flow path number = 64 (identical to 37 except for elevation)
- Flow area = 3.9500 m2
- Area/length ratio = 1.2500 m
- Flow coefficient = 1.5000
- From cell = 20
- To cell = 21 fl06400 icechest3-4 20 21 31.35 31.35
- fm,to elev fl06401 3.9500 3.1600 1.0000
- area, length, frac open fl06403 3.00 3.00
- k(forward),k(reverse) fl064s1 3.9500 3.1600 1.121
- area,length,shyd (segment)
- ice chest 3 to upper plenum 2 *
- Flow path number = 65
- Flow area = 5.6980 m2
- Area/length ratio = 0.5800 m
- Flow coefficient = 0.7000
- From cell = 20 Appendix C 44
- To cell = 23 fl06500 interdoors7 20 23 35.00 35.10
- fm,to elev fl06501 5.6980 9.8241 0.0
- area, length, frac open fl06503 1.40 1.40
- k(forward),k(reverse) fl06505 0.01
- max slip fl065s1 5.6980 9.8241 1.347
- area,length,shyd (segment) fl065v1 -1 969 969
- Note: To elevation changed from 35.00 to 35.10 so it fits in CV23 cf96900 'doorpmax' max 2 1.0 0.0 cf96901 0.0 cf96910 1.0 0.0 cfvalu.969
- this cf makes area increase cf96911 1.0 0.0 cfvalu.968
- irreversible cf96800 'door-p' tab-fun 1 1.0 0.0 cf96803 962 cf96810 1.0 0.0 cfvalu.967 cf96700 'dp20-23' add 2 1.0 0.0 cf96710 1.0 0.0 cvh-p.020 cf96711 -1.0 0.0 cvh-p.023
- ice chest 4 to upper plenum 2 *
- Flow path number = 66
- Flow area = 5.6980 m2
- Area/length ratio = 0.5800 m
- Flow coefficient = 0.7000
- From cell = 21
- To cell = 23 fl06600 interdoors7 21 23 35.00 35.10
- fm,to elev fl06601 5.6980 9.8241 0.0
- area, length, frac open fl06603 1.40 1.40
- k(forward),k(reverse) fl06605 0.01
- max slip fl066s1 5.6980 9.8241 1.347
- area,length,shyd (segment) fl066v1 -1 972 972
- Note: To elevation changed from 35.00 to 35.10 so it fits in CV23 cf97200 'doorpmax' max 2 1.0 0.0 cf97201 0.0 cf97210 1.0 0.0 cfvalu.972
- this cf makes area increase cf97211 1.0 0.0 cfvalu.971
- irreversible cf97100 'door-p' tab-fun 1 1.0 0.0 cf97103 962 cf97110 1.0 0.0 cfvalu.970 cf97000 'dp21-23' add 2 1.0 0.0 cf97010 1.0 0.0 cvh-p.021 cf97011 -1.0 0.0 cvh-p.023
- upper plenum 1 to 2 *
- Flow path number = 67 (identical to 40 except for elevation)
- Flow area = 6.2000 m2 Appendix C 45
- Area/length ratio = 1.0000 m
- Flow coefficient =.7000
- From cell = 22
- To cell = 23 fl06700 upplen1-2 22 23 38.90 38.90
- fm,to elev fl06701 6.2000 6.2000 1.0
- area, length, frac open fl06703 1.40 1.40
- k(forward),k(reverse) fl067s1 6.2000 6.2000 1.405
- area,length,shyd (segment)
- upper plenum doors to upper dome 1 *
- Flow path number = 68
- Flow area = 46.0400 m2
- Area/length ratio = 9.2100 m
- Flow coefficient = 0.6900
- From cell = 22
- To cell = 24 fl06800 upplendoor1 22 24 40.10 40.20
- fm,to elev fl06801 46.040 4.9989 0.0
- area, length, frac open fl06803 1.38 1.38
- k(forward),k(reverse) fl068s1 46.040 4.9989 1.347
- area,length,shyd (segment) fl068v1 -1 975 975
- Note: From elevation changed from 40.20 to 40.10 so it fits in CV22 cf97500 'doorpmax' max 2 1.0 0.0 cf97501 0.0 cf97510 1.0 0.0 cfvalu.975
- this cf makes area increase cf97511 1.0 0.0 cfvalu.974
- irreversible cf97400 'door-p' tab-fun 1 1.0 0.0 cf97403 974 cf97410 1.0 0.0 cfvalu.973 tf97400 'door-p' 4 1.0 0.0 tf97411 -1.e7 0.0 tf97412 4441.0 0.0 tf97413 8619.0 1.0 tf97414 1.e7 1.0 cf97300 'dp22-24' add 2 1.0 0.0 cf97310 1.0 0.0 cvh-p.022 cf97311 -1.0 0.0 cvh-p.024
- upper plenum doors to upper dome 2 *
- Flow path number = 69
- Flow area = 46.0400 m2
- Area/length ratio = 9.2100 m
- Flow coefficient = 0.6900
- From cell = 23
- To cell = 25 fl06900 upplendoor2 23 25 40.10 40.20
- fm,to elev fl06901 46.040 4.9989 0.0
- area, length, frac open fl06903 1.38 1.38
- k(forward),k(reverse)
Appendix C 46
fl069s1 46.040 4.9989 1.347
- area,length,shyd (segment) fl069v1 -1 978 978
- Note: From elevation changed from 40.20 to 40.10 so it fits in CV22 cf97800 'doorpmax' max 2 1.0 0.0 cf97801 0.0 cf97810 1.0 0.0 cfvalu.978
- this cf makes area increase cf97811 1.0 0.0 cfvalu.977
- irreversible cf97700 'door-p' tab-fun 1 1.0 0.0 cf97703 974 cf97710 1.0 0.0 cfvalu.976 cf97600 'dp23-25' add 2 1.0 0.0 cf97610 1.0 0.0 cvh-p.023 cf97611 -1.0 0.0 cvh-p.025
- dome 1 to dome 2 *
- Flow path number = 70 (identical to 43 except for elevation)
- Flow area = 296.5000 m2
- Area/length ratio = 16.7000 m
- Flow coefficient =.7000
- From cell = 24
- To cell = 25 fl07000 dome1-2 24 25 48.50 48.50
- fm,to elev fl07001 296.50 17.7545 1.0
- area, length, frac open fl07003 1.40 1.40
- k(forward),k(reverse) fl070s1 296.50 17.7545 9.715
- area,length,shyd (segment)
- air return fans, train 1 *
- Flow path number = 71
- Flow area = 1.0000 m2
- Area/length ratio = 10.0000 m
- Flow coefficient =
- From cell = 24
- To cell = 11
- Each fan provides min 40,000 cfm from upper compartment to accumulator room
- of lower compartment per FSAR Section 6.6. (Q = 40,000 cfm = 18.875 m3/s)
- Sequoyah CONTAIN model has approx 58,000 cfm per fan.
- fl07100 returnfan1 24 11 33.70 19.30
- fm,to elev
- fl07101 1.0 10.0 1.0
- area, length, frac open
- fl071s1 1.0 10.0 5.0
- area,length,shyd (segment)
- fl071t0 2 910
- cf91000 'fanvel' equals 1 1.0 0.0
- cf91010 18.875 0.0 cfvalu.138
- air return fans, train 2 *
- Flow path number = 72
- Flow area = 1.0000 m2 Appendix C 47
- Area/length ratio = 10.0000 m
- Flow coefficient =.****
- From cell = 25
- To cell = 13
- fl07200 returnfan2 25 13 33.70 19.30
- fm,to elev
- fl07201 1.0 10.0 1.0
- area, length, frac open
- fl072s1 1.0 10.0 5.0
- area,length,shyd (segment)
- fl072t0 2 910
- hydrogen skimmers 1 *
- Flow path number = 73
- Flow area = 0.1770 m2
- Area/length ratio = 1.0000 m
- Flow coefficient =.****
- From cell = 2
- To cell = 11
- fl07300 h2skimmer1 2 11 21.40 19.30
- fm,to elev
- fl07301 0.1770 1.00 1.0
- area, length, frac open
- fl073s1 0.1770 1.00 1.0
- area,length,shyd (segment)
- fl073t1 2 911
- cf91100 'skim_vel' equals 1 1.0 0.0
- cf91110 1.0 0.0 cfvalu.138
- hydrogen skimmers 2 *
- Flow path number = 74
- Flow area = 0.1770 m2
- Area/length ratio = 1.0000 m
- Flow coefficient =.****
- From cell = 3
- To cell = 11
- fl07400 h2skimmer2 3 11 21.40 19.30
- fm,to elev
- fl07401 0.1770 1.00 1.0
- area, length, frac open
- fl074s1 0.1770 1.00 1.0
- area,length,shyd (segment)
- fl074t1 2 911
- hydrogen skimmers 3 *
- Flow path number = 75
- Flow area = 0.1420 m2
- Area/length ratio = 1.0000 m
- Flow coefficient =.****
- From cell = 6
- To cell = 11
- fl07500 h2skimmer3 6 11 19.90 19.30
- fm,to elev
- fl07501 0.1420 1.00 1.0
- area, length, frac open
- fl075s1 0.1420 1.00 1.0
- area,length,shyd (segment)
- fl075t1 2 911
- hydrogen skimmers 4
- Appendix C 48
- Flow path number = 76
- Flow area = 0.1770 m2
- Area/length ratio = 1.0000 m
- Flow coefficient =.****
- From cell = 4
- To cell = 13
- fl07600 h2skimmer4 4 13 21.40 19.30
- fm,to elev
- fl07601 0.1770 1.00 1.0
- area, length, frac open
- fl076s1 0.1770 1.00 1.0
- area,length,shyd (segment)
- fl076t1 2 911
- hydrogen skimmers 5 *
- Flow path number = 77
- Flow area = 1.0000 m2
- Area/length ratio = 1.0000 m
- Flow coefficient =.****
- From cell = 5
- To cell = 13
- fl07700 h2skimmer5 5 13 21.40 19.30
- fm,to elev
- fl07701 0.1770 1.00 1.0
- area, length, frac open
- fl077s1 0.1770 1.00 1.0
- area,length,shyd (segment)
- fl077t1 2 911
- hydrogen skimmers 6 *
- Flow path number = 78
- Flow area = 0.1420 m2
- Area/length ratio = 1.0000 m
- Flow coefficient =.****
- From cell = 6
- To cell = 13
- fl07800 h2skimmer6 6 13 19.90 19.30
- fm,to elev
- fl07801 0.1420 1.00 1.0
- area, length, frac open
- fl078s1 0.1420 1.00 1.0
- area,length,shyd (segment)
- fl078t1 2 911
- Model of CONTAIN ENGINEER PIPES
- fl07900 Ice_drain 14 8 17.75 5.30
- fm,to elev fl07901 0.1 1.0 1.0
- area, length, frac open fl079s1 0.1 1.0 1.0
- area,length,shyd (segment) fl0790f 17.75 17.76 fl079v1 -1 990 990 cf99000 'drain' tab-fun 1 1.0 0.0 cf99003 990 cf99010 1.0 -17.75 cvh-cliqlev.014 tf99000 'drain' 3 1.0 0.0 tf99011 0.0 0.0 tf99012 0.15 0.0 Appendix C 49
tf99013 0.25 1.0 fl08000 Ice_drain 15 9 17.75 5.30
- fm,to elev fl08001 0.1 1.00 1.0
- area, length, frac open fl080s1 0.1 1.00 1.0
- area,length,shyd (segment) fl0800f 17.75 17.76 fl080v1 -1 991 991 cf99100 'drain' tab-fun 1 1.0 0.0 cf99103 990 cf99110 1.0 -17.75 cvh-cliqlev.015 fl08100 Ice_drain 16 9 17.75 5.30
- fm,to elev fl08101 0.1 1.0 1.0
- area, length, frac open fl081s1 0.1 1.0 1.0
- area,length,shyd (segment) fl0810f 17.75 17.76 fl081v1 -1 992 992 cf99200 'drain' tab-fun 1 1.0 0.0 cf99203 990 cf99210 1.0 -17.75 cvh-cliqlev.016 fl08200 Ice_drain 17 10 17.75 5.30
- fm,to elev fl08201 0.1 1.0 1.0
- area, length, frac open fl082s1 0.1 1.0 1.0
- area,length,shyd (segment) fl0820f 17.75 17.76 fl082v1 -1 993 993 cf99300 'drain' tab-fun 1 1.0 0.0 cf99303 990 cf99310 1.0 -17.75 cvh-cliqlev.017
- HS Input *
- hs_conr1 *
- Type = slab
- Cell number = 1
- Heat struct = 1
- Geometry = roof
- HS elev. = 3.5200 m
- LHS Cell bottom = -3.5200 m
- LHS Cell top = 3.5200 m
- Cell height = 7.0 m
- Charact. length = 5.2 m hs00101000 13 1 1 hs00101001 hs_conr1 hs00101002 3.5200.0000 hs00101003 1.
hs00101100 -1 1.0000 hs00101102.3500E-03 2 hs00101103.1000E-02 3 hs00101104.2000E-02 4 hs00101105.4000E-02 5 hs00101106.8000E-02 6 Appendix C 50
hs00101107.1600E-01 7 hs00101108.3000E-01 8 hs00101109.6000E-01 9 hs00101110.1200 10 hs00101111.2400 11 hs00101112.4800 12 hs00101113.8000 13 hs00101200 -1 hs00101201 concrete 1 hs00101202 concrete 2 hs00101203 concrete 3 hs00101204 concrete 4 hs00101205 concrete 5 hs00101206 concrete 6 hs00101207 concrete 7 hs00101208 concrete 8 hs00101209 concrete 9 hs00101210 concrete 10 hs00101211 concrete 11 hs00101212 concrete 12 hs00101300 -1 hs00101400 1 1 ext.5.5 hs00101401 0.800 equiv-band 5.74 hs00101500 23.65 5.180 5.180 hs00101600 0 -1 ext.5.5
- hs00101800 -1
- hs00101801 311.0 13
- hs_conw1 *
- Type = slab
- Cell number = 1
- Heat struct = 2
- Geometry = wall
- HS elev. = -3.5200 m
- LHS Cell bottom = -3.5200 m
- LHS Cell top = 3.5200 m
- Cell height = 7.0 m
- Charact. length = 7.0 m hs00102000 13 1 1 hs00102001 hs_conw1 hs00102002 -3.5200000 1.000 hs00102003 1.
hs00102100 -1 1.0000 hs00102102.3500E-03 2 hs00102103.1000E-02 3 hs00102104.2000E-02 4 hs00102105.4000E-02 5 hs00102106.8000E-02 6 hs00102107.1600E-01 7 hs00102108.3000E-01 8 hs00102109.6000E-01 9 hs00102110.1200 10 hs00102111.2400 11 hs00102112.4800 12 hs00102113.8000 13 hs00102200 -1 hs00102201 concrete 1 hs00102202 concrete 2 hs00102203 concrete 3 Appendix C 51
hs00102204 concrete 4 hs00102205 concrete 5 hs00102206 concrete 6 hs00102207 concrete 7 hs00102208 concrete 8 hs00102209 concrete 9 hs00102210 concrete 10 hs00102211 concrete 11 hs00102212 concrete 12 hs00102300 -1 hs00102400 1 1 ext.5.5 hs00102401 0.800 equiv-band 5.74 hs00102500 123.2 7.000 7.000 hs00102600 0 -1 ext.5.5
- hs00102800 -1
- hs00102801 311.0 13
- hs_conw1 *
- Type = slab
- Cell number = 1
- Heat struct = 3
- Geometry = wall
- HS elev. = -3.5200 m
- LHS Cell bottom = -3.5200 m
- LHS Cell top = 3.5200 m
- Cell height = 7.0 m
- Charact. length = 7.0 m hs00103000 13 1 1 hs00103001 hs_conw1 hs00103002 -3.5200000 1.000 hs00103003 1.
hs00103100 -1 1.0000 hs00103102.3500E-03 2 hs00103103.1000E-02 3 hs00103104.2000E-02 4 hs00103105.4000E-02 5 hs00103106.8000E-02 6 hs00103107.1600E-01 7 hs00103108.3000E-01 8 hs00103109.6000E-01 9 hs00103110.1200 10 hs00103111.2400 11 hs00103112.4800 12 hs00103113.8000 13 hs00103200 -1 hs00103201 concrete 1 hs00103202 concrete 2 hs00103203 concrete 3 hs00103204 concrete 4 hs00103205 concrete 5 hs00103206 concrete 6 hs00103207 concrete 7 hs00103208 concrete 8 hs00103209 concrete 9 hs00103210 concrete 10 hs00103211 concrete 11 hs00103212 concrete 12 hs00103300 -1 hs00103400 1 1 ext.5.5 Appendix C 52
hs00103401 0.800 equiv-band 0.20 hs00103500 133.4 7.000 7.000 hs00103600 0 -1 ext.5.5
- hs00103800 -1
- hs00103801 311.0 13
- hs_istrf *
- Type = top of hemisphere
- Cell number = 1
- Heat struct = 4
- Geometry = h_sphere
- HS elev. = 1.0440 m
- LHS Cell bottom = -3.5200 m
- LHS Cell top = 3.5200 m
- Cell height = 7.0 m
- Charact. length = 2.5 m hs00104000 12 5 1 hs00104001 hs_istrf hs00104002 1.0440.0000 hs00104003 1.
hs00104100 -1 1 2.26 hs00104111 2.476 12 hs00104110 2.47565 11 hs00104109 2.475 10 hs00104108 2.473 9 hs00104107 2.469 8 hs00104106 2.461 7 hs00104105 2.445 6 hs00104104 2.423 5 hs00104103 2.400 4 hs00104102 2.380 3 hs00104101 2.320 2 hs00104200 -1 hs00104211 insul 11 hs00104210 insul 10 hs00104209 insul 9 hs00104208 insul 8 hs00104207 insul 7 hs00104206 insul 6 hs00104205 insul 5 hs00104204 insul 4 hs00104203 'CARBON STEEL' 3 hs00104202 'CARBON STEEL' 2 hs00104201 'CARBON STEEL' 1 hs00104300 -1 hs00104400 1 1 ext.5.5 hs00104401.800 equiv-band 5.74 hs00104500 1.000 2.476 2.476 hs00104600 2110 -1 ext.5.5
- hs00104800 -1
- hs00104801 616.0 12
- hs_istw1 *
- Type = slab
- Cell number = 1
- Heat struct = 5 Appendix C 53
- Geometry = wall
- HS elev. = -3.5200 m
- LHS Cell bottom = -3.5200 m
- LHS Cell top = 3.5200 m
- Cell height = 7.0 m
- Charact. length = 7.0 m hs00105000 13 1 1 hs00105001 hs_istw1 hs00105002 -3.5200000 1.000 hs00105003 1.
hs00105100 -1 1.0000 hs00105102.3500E-03 2 hs00105103.1000E-02 3 hs00105104.2000E-02 4 hs00105105.4000E-02 5 hs00105106.8000E-02 6 hs00105107.1600E-01 7 hs00105108.3000E-01 8 hs00105109.5000E-01 9 hs00105110.7600E-01 10 hs00105111.1020 11 hs00105112.1400 12 hs00105113.2160 13 hs00105200 -1 hs00105201 insul 1 hs00105202 insul 2 hs00105203 insul 3 hs00105204 insul 4 hs00105205 insul 5 hs00105206 insul 6 hs00105207 insul 7 hs00105208 insul 8 hs00105209 insul 9 hs00105210 'CARBON STEEL' 10 hs00105211 'CARBON STEEL' 11 hs00105212 'CARBON STEEL' 12 hs00105300 -1 hs00105400 1 1 ext.5.5 hs00105401 0.800 equiv-band 0.20 hs00105500 126.4 7.000 7.000 hs00105600 2110 -1 ext.5.5
- hs00105800 -1
- hs00105801 616.0 13
- hs_lcell *
- Type = slab
- Cell number = 1
- Heat struct = 6
- Geometry = floor
- HS elev. = -7.1070 m
- LHS Cell bottom = -3.5200 m
- LHS Cell top = 3.5200 m
- Cell height = 7.0 m
- Charact. length = 7.7 m = sqrt(59.2 m2) hs00106000 13 1 1 hs00106001 hs_lcell Appendix C 54
hs00106002 -7.1070 -1.e-07 hs00106003 1.
hs00106100 -1 1.0000 hs00106102 0.0500 2 hs00106103 0.1000 3 hs00106104 0.2000 4 hs00106105 0.3000 5 hs00106106 0.4000 6 hs00106107 0.5000 7 hs00106108 1.0000 8 hs00106109 1.5000 9 hs00106110 2.0000 10 hs00106111 2.5000 11 hs00106112 3.0000 12 hs00106113 3.5870 13 hs00106200 -1 hs00106201 concrete 1 hs00106202 concrete 2 hs00106203 concrete 3 hs00106204 concrete 4 hs00106205 concrete 5 hs00106206 concrete 6 hs00106207 concrete 7 hs00106208 concrete 8 hs00106209 concrete 9 hs00106210 concrete 10 hs00106211 concrete 11 hs00106212 concrete 12 hs00106300 -1 hs00106400 1 1 ext.5.5 hs00106401 0.800 equiv-band 5.74 hs00106500 59.20 7.900 7.900 hs00106600 0 -1 ext.5.5
- hs00106800 -1
- hs00106801 311.0 13
- hs_conr2 *
- Type = slab
- Cell number = 2
- Heat struct = 1
- Geometry = roof
- HS elev. = 32.6000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 3.5 m hs00201000 12 1 1 hs00201001 hs_conr2 hs00201002 32.600.0000 hs00201003 1.
hs00201100 -1 1.0000 hs00201102.3500E-03 2 hs00201103.1000E-02 3 hs00201104.2000E-02 4 hs00201105.4000E-02 5 hs00201106.8000E-02 6 hs00201107.1600E-01 7 hs00201108.3000E-01 8 hs00201109.6000E-01 9 Appendix C 55
hs00201110.1200 10 hs00201111.2000 11 hs00201112.2700 12 hs00201200 -1 hs00201201 concrete 1 hs00201202 concrete 2 hs00201203 concrete 3 hs00201204 concrete 4 hs00201205 concrete 5 hs00201206 concrete 6 hs00201207 concrete 7 hs00201208 concrete 8 hs00201209 concrete 9 hs00201210 concrete 10 hs00201211 concrete 11 hs00201300 -1 hs00201400 1 2 ext.5.5 hs00201401 0.800 equiv-band 3.47 hs00201500 39.05 3.500 3.500 hs00201600 0 -1 ext.5.5
- hs00201800 -1
- hs00201801 311.0 12
- hs_conf2 *
- Type = slab
- Cell number = 2
- Heat struct = 2
- Geometry = floor
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 3.5 m hs00202000 12 1 1 hs00202001 hs_conf2 hs00202002 21.400 -.1000E-06 hs00202003 1.
hs00202100 -1 1.0000 hs00202102.3500E-03 2 hs00202103.1000E-02 3 hs00202104.2000E-02 4 hs00202105.4000E-02 5 hs00202106.8000E-02 6 hs00202107.1600E-01 7 hs00202108.3000E-01 8 hs00202109.6000E-01 9 hs00202110.1200 10 hs00202111.2000 11 hs00202112.2700 12 hs00202200 -1 hs00202201 concrete 1 hs00202202 concrete 2 hs00202203 concrete 3 hs00202204 concrete 4 hs00202205 concrete 5 hs00202206 concrete 6 hs00202207 concrete 7 hs00202208 concrete 8 Appendix C 56
hs00202209 concrete 9 hs00202210 concrete 10 hs00202211 concrete 11 hs00202300 -1 hs00202400 1 2 ext.5.5 hs00202401.800 equiv-band 3.47 hs00202500 23.05 3.500 3.500 hs00202600 0 -1 ext.5.5
- hs00202800 -1
- hs00202801 311.0 12
- hs_conw2 *
- Type = slab
- Cell number = 2
- Heat struct = 3
- Geometry = wall
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 5.5 m hs00203000 12 1 1 hs00203001 hs_conw2 hs00203002 21.400 1.000 hs00203003 1.
hs00203100 -1 1.0000 hs00203102.3500E-03 2 hs00203103.1000E-02 3 hs00203104.2000E-02 4 hs00203105.4000E-02 5 hs00203106.8000E-02 6 hs00203107.1600E-01 7 hs00203108.3000E-01 8 hs00203109.6000E-01 9 hs00203110.1200 10 hs00203111.2000 11 hs00203112.2700 12 hs00203200 -1 hs00203201 concrete 1 hs00203202 concrete 2 hs00203203 concrete 3 hs00203204 concrete 4 hs00203205 concrete 5 hs00203206 concrete 6 hs00203207 concrete 7 hs00203208 concrete 8 hs00203209 concrete 9 hs00203210 concrete 10 hs00203211 concrete 11 hs00203300 -1 hs00203400 1 2 ext.5.5 hs00203401.800 equiv-band 3.47 hs00203500 142.0 5.500 5.500 hs00203600 0 -1 ext.5.5
- hs00203800 -1
- hs00203801 311.0 12 Appendix C 57
- hs_stw2 *
- Type = slab
- Cell number = 2
- Heat struct = 4
- Geometry = wall
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 5.5 m hs00204000 10 1 1 hs00204001 hs_stw2 hs00204002 21.400 1.000 hs00204003 1.
hs00204100 -1 1.0000 hs00204102.3500E-03 2 hs00204103.1000E-02 3 hs00204104.2000E-02 4 hs00204105.4000E-02 5 hs00204106.8000E-02 6 hs00204107.1600E-01 7 hs00204108.3000E-01 8 hs00204109.5000E-01 9 hs00204110.6900E-01 10 hs00204200 -1 hs00204201 'CARBON STEEL' 1 hs00204202 'CARBON STEEL' 2 hs00204203 'CARBON STEEL' 3 hs00204204 'CARBON STEEL' 4 hs00204205 'CARBON STEEL' 5 hs00204206 'CARBON STEEL' 6 hs00204207 'CARBON STEEL' 7 hs00204208 'CARBON STEEL' 8 hs00204209 'CARBON STEEL' 9 hs00204300 -1 hs00204400 1 2 ext.5.5 hs00204401.800 equiv-band 3.47 hs00204500 172.0 5.500 5.500 hs00204600 0 -1 ext.5.5
- hs00204800 -1
- hs00204801 311.0 10
- hs_conr3 *
- Type = slab
- Cell number = 3
- Heat struct = 1
- Geometry = roof
- HS elev. = 32.6000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 3.5 m hs00301000 12 1 1 hs00301001 hs_conr3 hs00301002 32.600.0000 hs00301003 1.
Appendix C 58
hs00301100 -1 1.0000 hs00301102.3500E-03 2 hs00301103.1000E-02 3 hs00301104.2000E-02 4 hs00301105.4000E-02 5 hs00301106.8000E-02 6 hs00301107.1600E-01 7 hs00301108.3000E-01 8 hs00301109.6000E-01 9 hs00301110.1200 10 hs00301111.2000 11 hs00301112.2700 12 hs00301200 -1 hs00301201 concrete 1 hs00301202 concrete 2 hs00301203 concrete 3 hs00301204 concrete 4 hs00301205 concrete 5 hs00301206 concrete 6 hs00301207 concrete 7 hs00301208 concrete 8 hs00301209 concrete 9 hs00301210 concrete 10 hs00301211 concrete 11 hs00301300 -1 hs00301400 1 3 ext.5.5 hs00301401 0.800 equiv-band 3.47 hs00301500 39.05 3.500 3.500 hs00301600 0 -1 ext.5.5
- hs00301800 -1
- hs00301801 311.0 12
- hs_conf3 *
- Type = slab
- Cell number = 3
- Heat struct = 2
- Geometry = floor
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 3.5 m hs00302000 12 1 1 hs00302001 hs_conf3 hs00302002 21.400 -.1000E-06 hs00302003 1.
hs00302100 -1 1.0000 hs00302102.3500E-03 2 hs00302103.1000E-02 3 hs00302104.2000E-02 4 hs00302105.4000E-02 5 hs00302106.8000E-02 6 hs00302107.1600E-01 7 hs00302108.3000E-01 8 hs00302109.6000E-01 9 hs00302110.1200 10 hs00302111.2000 11 hs00302112.2700 12 hs00302200 -1 Appendix C 59
hs00302201 concrete 1 hs00302202 concrete 2 hs00302203 concrete 3 hs00302204 concrete 4 hs00302205 concrete 5 hs00302206 concrete 6 hs00302207 concrete 7 hs00302208 concrete 8 hs00302209 concrete 9 hs00302210 concrete 10 hs00302211 concrete 11 hs00302300 -1 hs00302400 1 3 ext.5.5 hs00302401.800 equiv-band 3.47 hs00302500 23.05 3.500 3.500 hs00302600 0 -1 ext.5.5
- hs00302800 -1
- hs00302801 311.0 12
- hs_conw3 *
- Type = slab
- Cell number = 3
- Heat struct = 3
- Geometry = wall
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 5.5 m hs00303000 12 1 1 hs00303001 hs_conw3 hs00303002 21.400 1.000 hs00303003 1.
hs00303100 -1 1.0000 hs00303102.3500E-03 2 hs00303103.1000E-02 3 hs00303104.2000E-02 4 hs00303105.4000E-02 5 hs00303106.8000E-02 6 hs00303107.1600E-01 7 hs00303108.3000E-01 8 hs00303109.6000E-01 9 hs00303110.1200 10 hs00303111.2000 11 hs00303112.2700 12 hs00303200 -1 hs00303201 concrete 1 hs00303202 concrete 2 hs00303203 concrete 3 hs00303204 concrete 4 hs00303205 concrete 5 hs00303206 concrete 6 hs00303207 concrete 7 hs00303208 concrete 8 hs00303209 concrete 9 hs00303210 concrete 10 hs00303211 concrete 11 hs00303300 -1 hs00303400 1 3 ext.5.5 Appendix C 60
hs00303401.800 equiv-band 3.47 hs00303500 142.0 5.500 5.500 hs00303600 0 -1 ext.5.5
- hs00303800 -1
- hs00303801 311.0 12
- hs_stw3 *
- Type = slab
- Cell number = 3
- Heat struct = 4
- Geometry = wall
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 5.5 m hs00304000 10 1 1 hs00304001 hs_stw3 hs00304002 21.400 1.000 hs00304003 1.
hs00304100 -1 1.0000 hs00304102.3500E-03 2 hs00304103.1000E-02 3 hs00304104.2000E-02 4 hs00304105.4000E-02 5 hs00304106.8000E-02 6 hs00304107.1600E-01 7 hs00304108.3000E-01 8 hs00304109.5000E-01 9 hs00304110.6900E-01 10 hs00304200 -1 hs00304201 'CARBON STEEL' 1 hs00304202 'CARBON STEEL' 2 hs00304203 'CARBON STEEL' 3 hs00304204 'CARBON STEEL' 4 hs00304205 'CARBON STEEL' 5 hs00304206 'CARBON STEEL' 6 hs00304207 'CARBON STEEL' 7 hs00304208 'CARBON STEEL' 8 hs00304209 'CARBON STEEL' 9 hs00304300 -1 hs00304400 1 3 ext.5.5 hs00304401.800 equiv-band 3.47 hs00304500 172.0 5.500 5.500 hs00304600 0 -1 ext.5.5
- hs00304800 -1
- hs00304801 311.0 10
- hs_conr4 *
- Type = slab
- Cell number = 4
- Heat struct = 1
- Geometry = roof
- HS elev. = 32.6000 m
- LHS Cell bottom = 21.4000 m Appendix C 61
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 3.5 m hs00401000 12 1 1 hs00401001 hs_conr4 hs00401002 32.600.0000 hs00401003 1.
hs00401100 -1 1.0000 hs00401102.3500E-03 2 hs00401103.1000E-02 3 hs00401104.2000E-02 4 hs00401105.4000E-02 5 hs00401106.8000E-02 6 hs00401107.1600E-01 7 hs00401108.3000E-01 8 hs00401109.6000E-01 9 hs00401110.1200 10 hs00401111.2000 11 hs00401112.2700 12 hs00401200 -1 hs00401201 concrete 1 hs00401202 concrete 2 hs00401203 concrete 3 hs00401204 concrete 4 hs00401205 concrete 5 hs00401206 concrete 6 hs00401207 concrete 7 hs00401208 concrete 8 hs00401209 concrete 9 hs00401210 concrete 10 hs00401211 concrete 11 hs00401300 -1 hs00401400 1 4 ext.5.5 hs00401401 0.800 equiv-band 3.47 hs00401500 39.05 3.500 3.500 hs00401600 0 -1 ext.5.5
- hs00401800 -1
- hs00401801 311.0 12
- hs_conf4 *
- Type = slab
- Cell number = 4
- Heat struct = 2
- Geometry = floor
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 3.5 m hs00402000 12 1 1 hs00402001 hs_conf4 hs00402002 21.400 -.1000E-06 hs00402003 1.
hs00402100 -1 1.0000 hs00402102.3500E-03 2 hs00402103.1000E-02 3 hs00402104.2000E-02 4 hs00402105.4000E-02 5 Appendix C 62
hs00402106.8000E-02 6 hs00402107.1600E-01 7 hs00402108.3000E-01 8 hs00402109.6000E-01 9 hs00402110.1200 10 hs00402111.2000 11 hs00402112.2700 12 hs00402200 -1 hs00402201 concrete 1 hs00402202 concrete 2 hs00402203 concrete 3 hs00402204 concrete 4 hs00402205 concrete 5 hs00402206 concrete 6 hs00402207 concrete 7 hs00402208 concrete 8 hs00402209 concrete 9 hs00402210 concrete 10 hs00402211 concrete 11 hs00402300 -1 hs00402400 1 4 ext.5.5 hs00402401.800 equiv-band 3.47 hs00402500 23.05 3.500 3.500 hs00402600 0 -1 ext.5.5
- hs00402800 -1
- hs00402801 311.0 12
- hs_conw4 *
- Type = slab
- Cell number = 4
- Heat struct = 3
- Geometry = wall
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 5.5 m hs00403000 12 1 1 hs00403001 hs_conw4 hs00403002 21.400 1.000 hs00403003 1.
hs00403100 -1 1.0000 hs00403102.3500E-03 2 hs00403103.1000E-02 3 hs00403104.2000E-02 4 hs00403105.4000E-02 5 hs00403106.8000E-02 6 hs00403107.1600E-01 7 hs00403108.3000E-01 8 hs00403109.6000E-01 9 hs00403110.1200 10 hs00403111.2000 11 hs00403112.2700 12 hs00403200 -1 hs00403201 concrete 1 hs00403202 concrete 2 hs00403203 concrete 3 hs00403204 concrete 4 hs00403205 concrete 5 Appendix C 63
hs00403206 concrete 6 hs00403207 concrete 7 hs00403208 concrete 8 hs00403209 concrete 9 hs00403210 concrete 10 hs00403211 concrete 11 hs00403300 -1 hs00403400 1 4 ext.5.5 hs00403401.800 equiv-band 3.47 hs00403500 142.0 5.500 5.500 hs00403600 0 -1 ext.5.5
- hs00403800 -1
- hs00403801 311.0 12
- hs_stw4 *
- Type = slab
- Cell number = 4
- Heat struct = 4
- Geometry = wall
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 5.5 m hs00404000 10 1 1 hs00404001 hs_stw4 hs00404002 21.400 1.000 hs00404003 1.
hs00404100 -1 1.0000 hs00404102.3500E-03 2 hs00404103.1000E-02 3 hs00404104.2000E-02 4 hs00404105.4000E-02 5 hs00404106.8000E-02 6 hs00404107.1600E-01 7 hs00404108.3000E-01 8 hs00404109.5000E-01 9 hs00404110.6900E-01 10 hs00404200 -1 hs00404201 'CARBON STEEL' 1 hs00404202 'CARBON STEEL' 2 hs00404203 'CARBON STEEL' 3 hs00404204 'CARBON STEEL' 4 hs00404205 'CARBON STEEL' 5 hs00404206 'CARBON STEEL' 6 hs00404207 'CARBON STEEL' 7 hs00404208 'CARBON STEEL' 8 hs00404209 'CARBON STEEL' 9 hs00404300 -1 hs00404400 1 4 ext.5.5 hs00404401.800 equiv-band 3.47 hs00404500 172.0 5.500 5.500 hs00404600 0 -1 ext.5.5
- hs00404800 -1
- hs00404801 311.0 10
- hs_conr5
- Appendix C 64
- Type = slab
- Cell number = 5
- Heat struct = 1
- Geometry = roof
- HS elev. = 32.6000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 3.5 m hs00501000 12 1 1 hs00501001 hs_conr5 hs00501002 32.600.0000 hs00501003 1.
hs00501100 -1 1.0000 hs00501102.3500E-03 2 hs00501103.1000E-02 3 hs00501104.2000E-02 4 hs00501105.4000E-02 5 hs00501106.8000E-02 6 hs00501107.1600E-01 7 hs00501108.3000E-01 8 hs00501109.6000E-01 9 hs00501110.1200 10 hs00501111.2000 11 hs00501112.2700 12 hs00501200 -1 hs00501201 concrete 1 hs00501202 concrete 2 hs00501203 concrete 3 hs00501204 concrete 4 hs00501205 concrete 5 hs00501206 concrete 6 hs00501207 concrete 7 hs00501208 concrete 8 hs00501209 concrete 9 hs00501210 concrete 10 hs00501211 concrete 11 hs00501300 -1 hs00501400 1 5 ext.5.5 hs00501401 0.800 equiv-band 3.47 hs00501500 39.05 3.500 3.500 hs00501600 0 -1 ext.5.5
- hs00501800 -1
- hs00501801 311.0 12
- hs_conf5 *
- Type = slab
- Cell number = 5
- Heat struct = 2
- Geometry = floor
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 3.5 m hs00502000 12 1 1 Appendix C 65
hs00502001 hs_conf5 hs00502002 21.400 -.1000E-06 hs00502003 1.
hs00502100 -1 1.0000 hs00502102.3500E-03 2 hs00502103.1000E-02 3 hs00502104.2000E-02 4 hs00502105.4000E-02 5 hs00502106.8000E-02 6 hs00502107.1600E-01 7 hs00502108.3000E-01 8 hs00502109.6000E-01 9 hs00502110.1200 10 hs00502111.2000 11 hs00502112.2700 12 hs00502200 -1 hs00502201 concrete 1 hs00502202 concrete 2 hs00502203 concrete 3 hs00502204 concrete 4 hs00502205 concrete 5 hs00502206 concrete 6 hs00502207 concrete 7 hs00502208 concrete 8 hs00502209 concrete 9 hs00502210 concrete 10 hs00502211 concrete 11 hs00502300 -1 hs00502400 1 5 ext.5.5 hs00502401.800 equiv-band 3.47 hs00502500 23.05 3.500 3.500 hs00502600 0 -1 ext.5.5
- hs00502800 -1
- hs00502801 311.0 12
- hs_conw5 *
- Type = slab
- Cell number = 5
- Heat struct = 3
- Geometry = wall
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 5.5 m hs00503000 12 1 1 hs00503001 hs_conw5 hs00503002 21.400 1.000 hs00503003 1.
hs00503100 -1 1.0000 hs00503102.3500E-03 2 hs00503103.1000E-02 3 hs00503104.2000E-02 4 hs00503105.4000E-02 5 hs00503106.8000E-02 6 hs00503107.1600E-01 7 hs00503108.3000E-01 8 hs00503109.6000E-01 9 Appendix C 66
hs00503110.1200 10 hs00503111.2000 11 hs00503112.2700 12 hs00503200 -1 hs00503201 concrete 1 hs00503202 concrete 2 hs00503203 concrete 3 hs00503204 concrete 4 hs00503205 concrete 5 hs00503206 concrete 6 hs00503207 concrete 7 hs00503208 concrete 8 hs00503209 concrete 9 hs00503210 concrete 10 hs00503211 concrete 11 hs00503300 -1 hs00503400 1 5 ext.5.5 hs00503401.800 equiv-band 3.47 hs00503500 142.0 5.500 5.500 hs00503600 0 -1 ext.5.5
- hs00503800 -1
- hs00503801 311.0 12
- hs_stw5 *
- Type = slab
- Cell number = 5
- Heat struct = 4
- Geometry = wall
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 5.5 m hs00504000 10 1 1 hs00504001 hs_stw5 hs00504002 21.400 1.000 hs00504003 1.
hs00504100 -1 1.0000 hs00504102.3500E-03 2 hs00504103.1000E-02 3 hs00504104.2000E-02 4 hs00504105.4000E-02 5 hs00504106.8000E-02 6 hs00504107.1600E-01 7 hs00504108.3000E-01 8 hs00504109.5000E-01 9 hs00504110.6900E-01 10 hs00504200 -1 hs00504201 'CARBON STEEL' 1 hs00504202 'CARBON STEEL' 2 hs00504203 'CARBON STEEL' 3 hs00504204 'CARBON STEEL' 4 hs00504205 'CARBON STEEL' 5 hs00504206 'CARBON STEEL' 6 hs00504207 'CARBON STEEL' 7 hs00504208 'CARBON STEEL' 8 hs00504209 'CARBON STEEL' 9 hs00504300 -1 hs00504400 1 5 ext.5.5 Appendix C 67
hs00504401.800 equiv-band 3.47 hs00504500 172.0 5.500 5.500 hs00504600 0 -1 ext.5.5
- hs00504800 -1
- hs00504801 311.0 10
- hs_conr6 *
- Type = slab
- Cell number = 6
- Heat struct = 1
- Geometry = roof
- HS elev. = 19.9000 m
- LHS Cell bottom = 12.1000 m
- LHS Cell top = 19.9000 m
- Cell height = 7.8 m
- Charact. length = 8.1 m hs00601000 13 1 1 hs00601001 hs_conr6 hs00601002 19.900.0000 hs00601003 1.
hs00601100 -1 1.0000 hs00601102.3500E-03 2 hs00601103.1000E-02 3 hs00601104.2000E-02 4 hs00601105.4000E-02 5 hs00601106.8000E-02 6 hs00601107.1600E-01 7 hs00601108.3000E-01 8 hs00601109.6000E-01 9 hs00601110.1200 10 hs00601111.2400 11 hs00601112.4100 12 hs00601113.6300 13 hs00601200 -1 hs00601201 concrete 1 hs00601202 concrete 2 hs00601203 concrete 3 hs00601204 concrete 4 hs00601205 concrete 5 hs00601206 concrete 6 hs00601207 concrete 7 hs00601208 concrete 8 hs00601209 concrete 9 hs00601210 concrete 10 hs00601211 concrete 11 hs00601212 concrete 12 hs00601300 -1 hs00601400 1 6 ext.5.5 hs00601401 0.800 equiv-band 3.95 hs00601500 51.50 8.100 8.100 hs00601600 0 -1 ext.5.5
- hs00601800 -1
- hs00601801 311.0 13
- hs_conf6 *
- Type = slab Appendix C 68
- Cell number = 6
- Heat struct = 2
- Geometry = floor
- HS elev. = 12.1000 m
- LHS Cell bottom = 12.1000 m
- LHS Cell top = 19.9000 m
- Cell height = 7.8 m
- Charact. length = 1.6 m hs00602000 13 1 1 hs00602001 hs_conf6 hs00602002 12.100 -.1000E-06 hs00602003 1.
hs00602100 -1 1.0000 hs00602102.3500E-03 2 hs00602103.1000E-02 3 hs00602104.2000E-02 4 hs00602105.4000E-02 5 hs00602106.8000E-02 6 hs00602107.1600E-01 7 hs00602108.3000E-01 8 hs00602109.6000E-01 9 hs00602110.1200 10 hs00602111.2400 11 hs00602112.4100 12 hs00602113.6300 13 hs00602200 -1 hs00602201 concrete 1 hs00602202 concrete 2 hs00602203 concrete 3 hs00602204 concrete 4 hs00602205 concrete 5 hs00602206 concrete 6 hs00602207 concrete 7 hs00602208 concrete 8 hs00602209 concrete 9 hs00602210 concrete 10 hs00602211 concrete 11 hs00602212 concrete 12 hs00602300 -1 hs00602400 1 6 ext.5.5 hs00602401.800 equiv-band 3.95 hs00602500 32.50 1.600 1.600 hs00602600 0 -1 ext.5.5
- hs00602800 -1
- hs00602801 311.0 13
- HS did not fit inside of volume
- Cell height = 9.4000 m
- Reset to = 7.8000 m
- hs_conw6 *
- Type = slab
- Cell number = 6
- Heat struct = 3
- Geometry = wall
- HS elev. = 12.1000 m
- LHS Cell bottom = 12.1000 m
- LHS Cell top = 19.9000 m Appendix C 69
- Cell height = 7.8 m
- Charact. length = 7.8 m hs00603000 13 1 1 hs00603001 hs_conw6 hs00603002 12.100 1.000 hs00603003 1.
hs00603100 -1 1.0000 hs00603102.3500E-03 2 hs00603103.1000E-02 3 hs00603104.2000E-02 4 hs00603105.4000E-02 5 hs00603106.8000E-02 6 hs00603107.1600E-01 7 hs00603108.3000E-01 8 hs00603109.6000E-01 9 hs00603110.1200 10 hs00603111.2400 11 hs00603112.4100 12 hs00603113.6300 13 hs00603200 -1 hs00603201 concrete 1 hs00603202 concrete 2 hs00603203 concrete 3 hs00603204 concrete 4 hs00603205 concrete 5 hs00603206 concrete 6 hs00603207 concrete 7 hs00603208 concrete 8 hs00603209 concrete 9 hs00603210 concrete 10 hs00603211 concrete 11 hs00603212 concrete 12 hs00603300 -1 hs00603400 1 6 ext.5.5 hs00603401.800 equiv-band 3.95 hs00603500 240.0 7.7999 7.7999 hs00603600 0 -1 ext.5.5
- hs00603800 -1
- hs00603801 311.0 13
- hs_istw6 *
- Type = slab
- Cell number = 6
- Heat struct = 4
- Geometry = wall
- HS elev. = 12.1000 m
- LHS Cell bottom = 12.1000 m
- LHS Cell top = 19.9000 m
- Cell height = 7.8 m
- Charact. length = 4.1 m hs00604000 13 1 1 hs00604001 hs_istw6 hs00604002 12.100 1.000 hs00604003 1.
hs00604100 -1 1.0000 hs00604102.3500E-03 2 hs00604103.1000E-02 3 hs00604104.2000E-02 4 Appendix C 70
hs00604105.4000E-02 5 hs00604106.8000E-02 6 hs00604107.1600E-01 7 hs00604108.3000E-01 8 hs00604109.5000E-01 9 hs00604110.7600E-01 10 hs00604111.1020 11 hs00604112.1540 12 hs00604113.2410 13 hs00604200 -1 hs00604201 insul 1 hs00604202 insul 2 hs00604203 insul 3 hs00604204 insul 4 hs00604205 insul 5 hs00604206 insul 6 hs00604207 insul 7 hs00604208 insul 8 hs00604209 insul 9 hs00604210 'CARBON STEEL' 10 hs00604211 'CARBON STEEL' 11 hs00604212 'CARBON STEEL' 12 hs00604300 -1 hs00604400 1 6 ext.5.5 hs00604401.800 equiv-band 3.95 hs00604500 57.20 4.100 4.100 hs00604600 2110 -1 ext.5.5
- hs00604800 -1
- hs00604801 616.0 13
- hs_istf6 *
- Type = slab
- Cell number = 6
- Heat struct = 5
- Geometry = floor
- HS elev. = 12.1000 m
- LHS Cell bottom = 12.1000 m
- LHS Cell top = 19.9000 m
- Cell height = 7.8 m
- Charact. length = 4.9 m hs00605000 13 1 1 hs00605001 hs_istf6 hs00605002 12.100 -.1000E-06 hs00605003 1.
hs00605100 -1 1.0000 hs00605102.3500E-03 2 hs00605103.1000E-02 3 hs00605104.2000E-02 4 hs00605105.4000E-02 5 hs00605106.8000E-02 6 hs00605107.1600E-01 7 hs00605108.3000E-01 8 hs00605109.5000E-01 9 hs00605110.7600E-01 10 hs00605111.1020 11 hs00605112.1540 12 hs00605113.2410 13 hs00605200 -1 hs00605201 insul 1 Appendix C 71
hs00605202 insul 2 hs00605203 insul 3 hs00605204 insul 4 hs00605205 insul 5 hs00605206 insul 6 hs00605207 insul 7 hs00605208 insul 8 hs00605209 insul 9 hs00605210 'CARBON STEEL' 10 hs00605211 'CARBON STEEL' 11 hs00605212 'CARBON STEEL' 12 hs00605300 -1 hs00605400 1 6 ext.5.5 hs00605401.800 equiv-band 3.95 hs00605500 19.00 4.900 4.900 hs00605600 2110 -1 ext.5.5
- hs00605800 -1
- hs00605801 616.0 13
- hs_conw7 *
- Type = slab
- Cell number = 7
- Heat struct = 1
- Geometry = wall
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 5.5 m hs00701000 12 1 1 hs00701001 hs_conw7 hs00701002 21.400 1.000 hs00701003 1.
hs00701100 -1 1.0000 hs00701102.3500E-03 2 hs00701103.1000E-02 3 hs00701104.2000E-02 4 hs00701105.4000E-02 5 hs00701106.8000E-02 6 hs00701107.1600E-01 7 hs00701108.3000E-01 8 hs00701109.6000E-01 9 hs00701110.1200 10 hs00701111.2000 11 hs00701112.2700 12 hs00701200 -1 hs00701201 concrete 1 hs00701202 concrete 2 hs00701203 concrete 3 hs00701204 concrete 4 hs00701205 concrete 5 hs00701206 concrete 6 hs00701207 concrete 7 hs00701208 concrete 8 hs00701209 concrete 9 hs00701210 concrete 10 hs00701211 concrete 11 hs00701300 -1 hs00701400 1 7 ext.5.5 Appendix C 72
hs00701401 0.800 equiv-band 3.47 hs00701500 64.00 5.500 5.500 hs00701600 0 -1 ext.5.5
- hs00701800 -1
- hs00701801 311.0 12
- hs_stw7 *
- Type = slab
- Cell number = 7
- Heat struct = 2
- Geometry = wall
- HS elev. = 21.4000 m
- LHS Cell bottom = 21.4000 m
- LHS Cell top = 32.6000 m
- Cell height = 11. m
- Charact. length = 5.5 m hs00702000 10 1 1 hs00702001 hs_stw7 hs00702002 21.400 1.000 hs00702003 1.
hs00702100 -1 1.0000 hs00702102.3500E-03 2 hs00702103.1000E-02 3 hs00702104.2000E-02 4 hs00702105.4000E-02 5 hs00702106.8000E-02 6 hs00702107.1600E-01 7 hs00702108.3000E-01 8 hs00702109.5000E-01 9 hs00702110.6900E-01 10 hs00702200 -1 hs00702201 'CARBON STEEL' 1 hs00702202 'CARBON STEEL' 2 hs00702203 'CARBON STEEL' 3 hs00702204 'CARBON STEEL' 4 hs00702205 'CARBON STEEL' 5 hs00702206 'CARBON STEEL' 6 hs00702207 'CARBON STEEL' 7 hs00702208 'CARBON STEEL' 8 hs00702209 'CARBON STEEL' 9 hs00702300 -1 hs00702400 1 7 ext.5.5 hs00702401.800 equiv-band 3.47 hs00702500 64.00 5.500 5.500 hs00702600 0 -1 ext.5.5
- hs00702800 -1
- hs00702801 311.0 10
- hs_conr8 *
- Type = slab
- Cell number = 8
- Heat struct = 1
- Geometry = roof
- HS elev. = 19.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m Appendix C 73
- Cell height = 14. m
- Charact. length = 6.7 m hs00801000 12 1 1 hs00801001 hs_conr8 hs00801002 19.300.0000 hs00801003 1.
hs00801100 -1 1.0000 hs00801102.3500E-03 2 hs00801103.1000E-02 3 hs00801104.2000E-02 4 hs00801105.4000E-02 5 hs00801106.8000E-02 6 hs00801107.1600E-01 7 hs00801108.3000E-01 8 hs00801109.6000E-01 9 hs00801110.1200 10 hs00801111.2400 11 hs00801112.3600 12 hs00801200 -1 hs00801201 concrete 1 hs00801202 concrete 2 hs00801203 concrete 3 hs00801204 concrete 4 hs00801205 concrete 5 hs00801206 concrete 6 hs00801207 concrete 7 hs00801208 concrete 8 hs00801209 concrete 9 hs00801210 concrete 10 hs00801211 concrete 11 hs00801300 -1 hs00801400 1 8 ext.5.5 hs00801401.800 equiv-band 3.22 hs00801500 124.0 6.700 6.700 hs00801600 0 -1 ext.5.5
- hs00801800 -1
- hs00801801 311.0 12
- HS did not fit inside of volume
- Cell height = 14.0000 m
- Reset to = 14.0000 m
- hs_conw8 *
- Type = slab
- Cell number = 8
- Heat struct = 2
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 14. m hs00802000 12 1 1 hs00802001 hs_conw8 hs00802002 5.3000 1.000 hs00802003 1.
hs00802100 -1 1.0000 Appendix C 74
hs00802102.3500E-03 2 hs00802103.1000E-02 3 hs00802104.2000E-02 4 hs00802105.4000E-02 5 hs00802106.8000E-02 6 hs00802107.1600E-01 7 hs00802108.3000E-01 8 hs00802109.6000E-01 9 hs00802110.1200 10 hs00802111.2400 11 hs00802112.3600 12 hs00802200 -1 hs00802201 concrete 1 hs00802202 concrete 2 hs00802203 concrete 3 hs00802204 concrete 4 hs00802205 concrete 5 hs00802206 concrete 6 hs00802207 concrete 7 hs00802208 concrete 8 hs00802209 concrete 9 hs00802210 concrete 10 hs00802211 concrete 11 hs00802300 -1 hs00802400 1 8 ext.5.5 hs00802401.800 equiv-band 3.22 hs00802500 727.0 14.00 14.00 hs00802600 0 -1 ext.5.5
- hs00802800 -1
- hs00802801 311.0 12
- HS did not fit inside of volume
- Cell height = 14.0000 m
- Reset to = 14.0000 m
- hs_stw8 *
- Type = slab
- Cell number = 8
- Heat struct = 3
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 14. m hs00803000 10 1 1 hs00803001 hs_stw8 hs00803002 5.3000 1.000 hs00803003 1.
hs00803100 -1 1.0000 hs00803102.3500E-03 2 hs00803103.1000E-02 3 hs00803104.2000E-02 4 hs00803105.4000E-02 5 hs00803106.8000E-02 6 hs00803107.1600E-01 7 hs00803108.3000E-01 8 hs00803109.5000E-01 9 Appendix C 75
hs00803110.6900E-01 10 hs00803200 -1 hs00803201 'CARBON STEEL' 1 hs00803202 'CARBON STEEL' 2 hs00803203 'CARBON STEEL' 3 hs00803204 'CARBON STEEL' 4 hs00803205 'CARBON STEEL' 5 hs00803206 'CARBON STEEL' 6 hs00803207 'CARBON STEEL' 7 hs00803208 'CARBON STEEL' 8 hs00803209 'CARBON STEEL' 9 hs00803300 -1 hs00803400 1 8 ext.5.5 hs00803401.800 equiv-band 3.22 hs00803500 784.3 14.00 14.00 hs00803600 0 -1 ext.5.5
- hs00803800 -1
- hs00803801 311.0 10
- hs_lcell *
- Type = slab
- Cell number = 8
- Heat struct = 4
- Geometry = floor
- HS elev. = 1.6800 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 11.1 m
- Charact. length = 11.1 m = sqrt(124 m2) hs00804000 13 1 1 hs00804001 hs_lcell hs00804002 1.6900 -1.e-7 hs00804003 1.
hs00804100 -1 1.0000 hs00804102 0.0500 2 hs00804103 0.1000 3 hs00804104 0.2000 4 hs00804105 0.3000 5 hs00804106 0.4000 6 hs00804107 0.5000 7 hs00804108 1.0000 8 hs00804109 1.5000 9 hs00804110 2.0000 10 hs00804111 2.5000 11 hs00804112 3.0000 12 hs00804113 3.6200 13 hs00804200 -1 hs00804201 concrete 1 hs00804202 concrete 2 hs00804203 concrete 3 hs00804204 concrete 4 hs00804205 concrete 5 hs00804206 concrete 6 hs00804207 concrete 7 hs00804208 concrete 8 hs00804209 concrete 9 hs00804210 concrete 10 hs00804211 concrete 11 Appendix C 76
hs00804212 concrete 12 hs00804300 -1 hs00804400 1 8 ext.5.5 hs00804401 0.800 equiv-band 3.22 hs00804500 124.0 11.100 11.100 hs00804600 0 -1 ext.5.5
- hs00804800 -1
- hs00804801 311.0 13
- hs_conr9 *
- Type = slab
- Cell number = 9
- Heat struct = 1
- Geometry = roof
- HS elev. = 19.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 6.7 m hs00901000 12 1 1 hs00901001 hs_conr9 hs00901002 19.300.0000 hs00901003 1.
hs00901100 -1 1.0000 hs00901102.3500E-03 2 hs00901103.1000E-02 3 hs00901104.2000E-02 4 hs00901105.4000E-02 5 hs00901106.8000E-02 6 hs00901107.1600E-01 7 hs00901108.3000E-01 8 hs00901109.6000E-01 9 hs00901110.1200 10 hs00901111.2400 11 hs00901112.3600 12 hs00901200 -1 hs00901201 concrete 1 hs00901202 concrete 2 hs00901203 concrete 3 hs00901204 concrete 4 hs00901205 concrete 5 hs00901206 concrete 6 hs00901207 concrete 7 hs00901208 concrete 8 hs00901209 concrete 9 hs00901210 concrete 10 hs00901211 concrete 11 hs00901300 -1 hs00901400 1 9 ext.5.5 hs00901401.800 equiv-band 3.22 hs00901500 106.0 6.700 6.700 hs00901600 0 -1 ext.5.5
- hs00901800 -1
- hs00901801 311.0 12
- HS did not fit inside of volume
- Cell height = 14.0000 m
- Reset to = 14.0000 m Appendix C 77
- hs_conw9 *
- Type = slab
- Cell number = 9
- Heat struct = 2
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 14. m hs00902000 12 1 1 hs00902001 hs_conw9 hs00902002 5.3000 1.000 hs00902003 1.
hs00902100 -1 1.0000 hs00902102.3500E-03 2 hs00902103.1000E-02 3 hs00902104.2000E-02 4 hs00902105.4000E-02 5 hs00902106.8000E-02 6 hs00902107.1600E-01 7 hs00902108.3000E-01 8 hs00902109.6000E-01 9 hs00902110.1200 10 hs00902111.2400 11 hs00902112.3600 12 hs00902200 -1 hs00902201 concrete 1 hs00902202 concrete 2 hs00902203 concrete 3 hs00902204 concrete 4 hs00902205 concrete 5 hs00902206 concrete 6 hs00902207 concrete 7 hs00902208 concrete 8 hs00902209 concrete 9 hs00902210 concrete 10 hs00902211 concrete 11 hs00902300 -1 hs00902400 1 9 ext.5.5 hs00902401.800 equiv-band 3.22 hs00902500 623.0 14.00 14.00 hs00902600 0 -1 ext.5.5
- hs00902800 -1
- hs00902801 311.0 12
- HS did not fit inside of volume
- Cell height = 14.0000 m
- Reset to = 14.0000 m
- hs_stw9 *
- Type = slab
- Cell number = 9
- Heat struct = 3 Appendix C 78
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 14. m hs00903000 10 1 1 hs00903001 hs_stw9 hs00903002 5.3000 1.000 hs00903003 1.
hs00903100 -1 1.0000 hs00903102.3500E-03 2 hs00903103.1000E-02 3 hs00903104.2000E-02 4 hs00903105.4000E-02 5 hs00903106.8000E-02 6 hs00903107.1600E-01 7 hs00903108.3000E-01 8 hs00903109.5000E-01 9 hs00903110.6900E-01 10 hs00903200 -1 hs00903201 'CARBON STEEL' 1 hs00903202 'CARBON STEEL' 2 hs00903203 'CARBON STEEL' 3 hs00903204 'CARBON STEEL' 4 hs00903205 'CARBON STEEL' 5 hs00903206 'CARBON STEEL' 6 hs00903207 'CARBON STEEL' 7 hs00903208 'CARBON STEEL' 8 hs00903209 'CARBON STEEL' 9 hs00903300 -1 hs00903400 1 9 ext.5.5 hs00903401.800 equiv-band 3.22 hs00903500 681.3 14.00 14.00 hs00903600 0 -1 ext.5.5
- hs00903800 -1
- hs00903801 311.0 10
- hs_lcell *
- Type = slab
- Cell number = 9
- Heat struct = 4
- Geometry = floor
- HS elev. = 1.6800 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 10.2 m
- Charact. length = 10.2 m = sqrt(106 m2) hs00904000 13 1 1 hs00904001 hs_lcell hs00904002 1.6900 -1.e-7 hs00904003 1.
hs00904100 -1 1.0000 hs00904102 0.0500 2 hs00904103 0.1000 3 hs00904104 0.2000 4 hs00904105 0.3000 5 hs00904106 0.4000 6 Appendix C 79
hs00904107 0.5000 7 hs00904108 1.0000 8 hs00904109 1.5000 9 hs00904110 2.0000 10 hs00904111 2.5000 11 hs00904112 3.0000 12 hs00904113 3.6200 13 hs00904200 -1 hs00904201 concrete 1 hs00904202 concrete 2 hs00904203 concrete 3 hs00904204 concrete 4 hs00904205 concrete 5 hs00904206 concrete 6 hs00904207 concrete 7 hs00904208 concrete 8 hs00904209 concrete 9 hs00904210 concrete 10 hs00904211 concrete 11 hs00904212 concrete 12 hs00904300 -1 hs00904400 1 9 ext.5.5 hs00904401 0.800 equiv-band 3.22 hs00904500 106.0 10.200 10.200 hs00904600 0 -1 ext.5.5
- hs00904800 -1
- hs00904801 311.0 13
- hs_conr1 *
- Type = slab
- Cell number = 10
- Heat struct = 1
- Geometry = roof
- HS elev. = 19.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 6.7 m hs01001000 12 1 1 hs01001001 hs_conr1 hs01001002 19.300.0000 hs01001003 1.
hs01001100 -1 1.0000 hs01001102.3500E-03 2 hs01001103.1000E-02 3 hs01001104.2000E-02 4 hs01001105.4000E-02 5 hs01001106.8000E-02 6 hs01001107.1600E-01 7 hs01001108.3000E-01 8 hs01001109.6000E-01 9 hs01001110.1200 10 hs01001111.2400 11 hs01001112.3600 12 hs01001200 -1 hs01001201 concrete 1 hs01001202 concrete 2 hs01001203 concrete 3 hs01001204 concrete 4 Appendix C 80
hs01001205 concrete 5 hs01001206 concrete 6 hs01001207 concrete 7 hs01001208 concrete 8 hs01001209 concrete 9 hs01001210 concrete 10 hs01001211 concrete 11 hs01001300 -1 hs01001400 1 10 ext.5.5 hs01001401.800 equiv-band 3.22 hs01001500 124.0 6.700 6.700 hs01001600 0 -1 ext.5.5
- hs01001800 -1
- hs01001801 311.0 12
- HS did not fit inside of volume
- Cell height = 14.0000 m
- Reset to = 14.0000 m
- hs_conw1 *
- Type = slab
- Cell number = 10
- Heat struct = 2
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 14. m hs01002000 12 1 1 hs01002001 hs_conw1 hs01002002 5.3000 1.000 hs01002003 1.
hs01002100 -1 1.0000 hs01002102.3500E-03 2 hs01002103.1000E-02 3 hs01002104.2000E-02 4 hs01002105.4000E-02 5 hs01002106.8000E-02 6 hs01002107.1600E-01 7 hs01002108.3000E-01 8 hs01002109.6000E-01 9 hs01002110.1200 10 hs01002111.2400 11 hs01002112.3600 12 hs01002200 -1 hs01002201 concrete 1 hs01002202 concrete 2 hs01002203 concrete 3 hs01002204 concrete 4 hs01002205 concrete 5 hs01002206 concrete 6 hs01002207 concrete 7 hs01002208 concrete 8 hs01002209 concrete 9 hs01002210 concrete 10 hs01002211 concrete 11 Appendix C 81
hs01002300 -1 hs01002400 1 10 ext.5.5 hs01002401.800 equiv-band 3.22 hs01002500 727.0 14.00 14.00 hs01002600 0 -1 ext.5.5
- hs01002800 -1
- hs01002801 311.0 12
- HS did not fit inside of volume
- Cell height = 14.0000 m
- Reset to = 14.0000 m
- hs_stw10 *
- Type = slab
- Cell number = 10
- Heat struct = 3
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 14. m hs01003000 10 1 1 hs01003001 hs_stw10 hs01003002 5.3000 1.000 hs01003003 1.
hs01003100 -1 1.0000 hs01003102.3500E-03 2 hs01003103.1000E-02 3 hs01003104.2000E-02 4 hs01003105.4000E-02 5 hs01003106.8000E-02 6 hs01003107.1600E-01 7 hs01003108.3000E-01 8 hs01003109.5000E-01 9 hs01003110.6900E-01 10 hs01003200 -1 hs01003201 'CARBON STEEL' 1 hs01003202 'CARBON STEEL' 2 hs01003203 'CARBON STEEL' 3 hs01003204 'CARBON STEEL' 4 hs01003205 'CARBON STEEL' 5 hs01003206 'CARBON STEEL' 6 hs01003207 'CARBON STEEL' 7 hs01003208 'CARBON STEEL' 8 hs01003209 'CARBON STEEL' 9 hs01003300 -1 hs01003400 1 10 ext.5.5 hs01003401.800 equiv-band 3.22 hs01003500 784.3 14.00 14.00 hs01003600 0 -1 ext.5.5
- hs01003800 -1
- hs01003801 311.0 10
- hs_lcell
- Appendix C 82
- Type = slab
- Cell number = 8
- Heat struct = 4
- Geometry = floor
- HS elev. = 1.6800 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 11.1 m
- Charact. length = 11.1 m = sqrt(124 m2) hs01004000 13 1 1 hs01004001 hs_lcell hs01004002 1.6900 -1.e-7 hs01004003 1.
hs01004100 -1 1.0000 hs01004102 0.0500 2 hs01004103 0.1000 3 hs01004104 0.2000 4 hs01004105 0.3000 5 hs01004106 0.4000 6 hs01004107 0.5000 7 hs01004108 1.0000 8 hs01004109 1.5000 9 hs01004110 2.0000 10 hs01004111 2.5000 11 hs01004112 3.0000 12 hs01004113 3.6200 13 hs01004200 -1 hs01004201 concrete 1 hs01004202 concrete 2 hs01004203 concrete 3 hs01004204 concrete 4 hs01004205 concrete 5 hs01004206 concrete 6 hs01004207 concrete 7 hs01004208 concrete 8 hs01004209 concrete 9 hs01004210 concrete 10 hs01004211 concrete 11 hs01004212 concrete 12 hs01004300 -1 hs01004400 1 10 ext.5.5 hs01004401 0.800 equiv-band 3.22 hs01004500 124.0 11.100 11.100 hs01004600 0 -1 ext.5.5
- hs01004800 -1
- hs01004801 311.0 13
- hs_conr1 *
- Type = slab
- Cell number = 11
- Heat struct = 1
- Geometry = roof
- HS elev. = 19.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 3.9 m Appendix C 83
hs01101000 12 1 1 hs01101001 hs_conr1 hs01101002 19.300.0000 hs01101003 1.
hs01101100 -1 1.0000 hs01101102.3500E-03 2 hs01101103.1000E-02 3 hs01101104.2000E-02 4 hs01101105.4000E-02 5 hs01101106.8000E-02 6 hs01101107.1600E-01 7 hs01101108.3000E-01 8 hs01101109.6000E-01 9 hs01101110.1200 10 hs01101111.2400 11 hs01101112.3600 12 hs01101200 -1 hs01101201 concrete 1 hs01101202 concrete 2 hs01101203 concrete 3 hs01101204 concrete 4 hs01101205 concrete 5 hs01101206 concrete 6 hs01101207 concrete 7 hs01101208 concrete 8 hs01101209 concrete 9 hs01101210 concrete 10 hs01101211 concrete 11 hs01101300 -1 hs01101400 1 11 ext.5.5 hs01101401.800 equiv-band 1.89 hs01101500 215.0 3.900 3.900 hs01101600 0 -1 ext.5.5
- hs01101800 -1
- hs01101801 311.0 12
- hs_conf1 *
- Type = slab
- Cell number = 11
- Heat struct = 2
- Geometry = floor
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 3.9 m hs01102000 12 1 1 hs01102001 hs_conf1 hs01102002 5.3000 -.1000E-06 hs01102003 1.
hs01102100 -1 1.0000 hs01102102.3500E-03 2 hs01102103.1000E-02 3 hs01102104.2000E-02 4 hs01102105.4000E-02 5 hs01102106.8000E-02 6 hs01102107.1600E-01 7 Appendix C 84
hs01102108.3000E-01 8 hs01102109.6000E-01 9 hs01102110.1200 10 hs01102111.2400 11 hs01102112.3600 12 hs01102200 -1 hs01102201 concrete 1 hs01102202 concrete 2 hs01102203 concrete 3 hs01102204 concrete 4 hs01102205 concrete 5 hs01102206 concrete 6 hs01102207 concrete 7 hs01102208 concrete 8 hs01102209 concrete 9 hs01102210 concrete 10 hs01102211 concrete 11 hs01102300 -1 hs01102400 1 11 ext.5.5 hs01102401.800 equiv-band 1.89 hs01102500 215.0 3.900 3.900 hs01102600 0 -1 ext.5.5
- hs01102800 -1
- hs01102801 311.0 12
- hs_conw1 *
- Type = slab
- Cell number = 11
- Heat struct = 3
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 7.0 m hs01103000 12 1 1 hs01103001 hs_conw1 hs01103002 5.3000 1.000 hs01103003 1.
hs01103100 -1 1.0000 hs01103102.3500E-03 2 hs01103103.1000E-02 3 hs01103104.2000E-02 4 hs01103105.4000E-02 5 hs01103106.8000E-02 6 hs01103107.1600E-01 7 hs01103108.3000E-01 8 hs01103109.6000E-01 9 hs01103110.1200 10 hs01103111.2400 11 hs01103112.3600 12 hs01103200 -1 hs01103201 concrete 1 hs01103202 concrete 2 hs01103203 concrete 3 hs01103204 concrete 4 hs01103205 concrete 5 hs01103206 concrete 6 hs01103207 concrete 7 Appendix C 85
hs01103208 concrete 8 hs01103209 concrete 9 hs01103210 concrete 10 hs01103211 concrete 11 hs01103300 -1 hs01103400 1 11 ext.5.5 hs01103401.800 equiv-band 1.89 hs01103500 627.0 7.000 7.000 hs01103600 0 -1 ext.5.5
- hs01103800 -1
- hs01103801 311.0 12
- HS did not fit inside of volume
- Cell height = 14.0000 m
- Reset to = 14.0000 m
- hs_stw11 *
- Type = slab
- Cell number = 11
- Heat struct = 4
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 14. m hs01104000 9 1 1 hs01104001 hs_stw11 hs01104002 5.3000 1.000 hs01104003 1.
hs01104100 -1 1.0000 hs01104102.3500E-03 2 hs01104103.1000E-02 3 hs01104104.2000E-02 4 hs01104105.4000E-02 5 hs01104106.8000E-02 6 hs01104107.1300E-01 7 hs01104108.2100E-01 8 hs01104109.3100E-01 9 hs01104200 -1 hs01104201 'CARBON STEEL' 1 hs01104202 'CARBON STEEL' 2 hs01104203 'CARBON STEEL' 3 hs01104204 'CARBON STEEL' 4 hs01104205 'CARBON STEEL' 5 hs01104206 'CARBON STEEL' 6 hs01104207 'CARBON STEEL' 7 hs01104208 'CARBON STEEL' 8 hs01104300 -1 hs01104400 1 11 ext.5.5 hs01104401.800 equiv-band 1.89 hs01104500 595.0 14.00 14.00 hs01104600 0 -1 ext.5.5
- hs01104800 -1
- hs01104801 311.0 9
- hs_conr1
- Appendix C 86
- Type = slab
- Cell number = 12
- Heat struct = 1
- Geometry = roof
- HS elev. = 19.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 3.9 m hs01201000 12 1 1 hs01201001 hs_conr1 hs01201002 19.300.0000 hs01201003 1.
hs01201100 -1 1.0000 hs01201102.3500E-03 2 hs01201103.1000E-02 3 hs01201104.2000E-02 4 hs01201105.4000E-02 5 hs01201106.8000E-02 6 hs01201107.1600E-01 7 hs01201108.3000E-01 8 hs01201109.6000E-01 9 hs01201110.1200 10 hs01201111.2400 11 hs01201112.3600 12 hs01201200 -1 hs01201201 concrete 1 hs01201202 concrete 2 hs01201203 concrete 3 hs01201204 concrete 4 hs01201205 concrete 5 hs01201206 concrete 6 hs01201207 concrete 7 hs01201208 concrete 8 hs01201209 concrete 9 hs01201210 concrete 10 hs01201211 concrete 11 hs01201300 -1 hs01201400 1 12 ext.5.5 hs01201401.800 equiv-band 1.88 hs01201500 211.0 3.900 3.900 hs01201600 0 -1 ext.5.5
- hs01201800 -1
- hs01201801 311.0 12
- hs_conf1 *
- Type = slab
- Cell number = 12
- Heat struct = 2
- Geometry = floor
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 3.9 m hs01202000 12 1 1 Appendix C 87
hs01202001 hs_conf1 hs01202002 5.3000 -.1000E-06 hs01202003 1.
hs01202100 -1 1.0000 hs01202102.3500E-03 2 hs01202103.1000E-02 3 hs01202104.2000E-02 4 hs01202105.4000E-02 5 hs01202106.8000E-02 6 hs01202107.1600E-01 7 hs01202108.3000E-01 8 hs01202109.6000E-01 9 hs01202110.1200 10 hs01202111.2400 11 hs01202112.3600 12 hs01202200 -1 hs01202201 concrete 1 hs01202202 concrete 2 hs01202203 concrete 3 hs01202204 concrete 4 hs01202205 concrete 5 hs01202206 concrete 6 hs01202207 concrete 7 hs01202208 concrete 8 hs01202209 concrete 9 hs01202210 concrete 10 hs01202211 concrete 11 hs01202300 -1 hs01202400 1 12 ext.5.5 hs01202401.800 equiv-band 1.88 hs01202500 211.0 3.900 3.900 hs01202600 0 -1 ext.5.5
- hs01202800 -1
- hs01202801 311.0 12
- hs_conw1 *
- Type = slab
- Cell number = 12
- Heat struct = 3
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 7.0 m hs01203000 12 1 1 hs01203001 hs_conw1 hs01203002 5.3000 1.000 hs01203003 1.
hs01203100 -1 1.0000 hs01203102.3500E-03 2 hs01203103.1000E-02 3 hs01203104.2000E-02 4 hs01203105.4000E-02 5 hs01203106.8000E-02 6 hs01203107.1600E-01 7 hs01203108.3000E-01 8 hs01203109.6000E-01 9 hs01203110.1200 10 Appendix C 88
hs01203111.2400 11 hs01203112.3600 12 hs01203200 -1 hs01203201 concrete 1 hs01203202 concrete 2 hs01203203 concrete 3 hs01203204 concrete 4 hs01203205 concrete 5 hs01203206 concrete 6 hs01203207 concrete 7 hs01203208 concrete 8 hs01203209 concrete 9 hs01203210 concrete 10 hs01203211 concrete 11 hs01203300 -1 hs01203400 1 12 ext.5.5 hs01203401.800 equiv-band 1.88 hs01203500 613.0 7.000 7.000 hs01203600 0 -1 ext.5.5
- hs01203800 -1
- hs01203801 311.0 12
- HS did not fit inside of volume
- Cell height = 14.0000 m
- Reset to = 14.0000 m
- hs_stw12 *
- Type = slab
- Cell number = 12
- Heat struct = 4
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 14. m hs01204000 9 1 1 hs01204001 hs_stw12 hs01204002 5.3000 1.000 hs01204003 1.
hs01204100 -1 1.0000 hs01204102.3500E-03 2 hs01204103.1000E-02 3 hs01204104.2000E-02 4 hs01204105.4000E-02 5 hs01204106.8000E-02 6 hs01204107.1300E-01 7 hs01204108.2100E-01 8 hs01204109.3100E-01 9 hs01204200 -1 hs01204201 'CARBON STEEL' 1 hs01204202 'CARBON STEEL' 2 hs01204203 'CARBON STEEL' 3 hs01204204 'CARBON STEEL' 4 hs01204205 'CARBON STEEL' 5 hs01204206 'CARBON STEEL' 6 hs01204207 'CARBON STEEL' 7 hs01204208 'CARBON STEEL' 8 Appendix C 89
hs01204300 -1 hs01204400 1 12 ext.5.5 hs01204401.800 equiv-band 1.88 hs01204500 583.0 14.00 14.00 hs01204600 0 -1 ext.5.5
- hs01204800 -1
- hs01204801 311.0 9
- hs_conr1 *
- Type = slab
- Cell number = 13
- Heat struct = 1
- Geometry = roof
- HS elev. = 19.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 3.9 m hs01301000 12 1 1 hs01301001 hs_conr1 hs01301002 19.300.0000 hs01301003 1.
hs01301100 -1 1.0000 hs01301102.3500E-03 2 hs01301103.1000E-02 3 hs01301104.2000E-02 4 hs01301105.4000E-02 5 hs01301106.8000E-02 6 hs01301107.1600E-01 7 hs01301108.3000E-01 8 hs01301109.6000E-01 9 hs01301110.1200 10 hs01301111.2400 11 hs01301112.3600 12 hs01301200 -1 hs01301201 concrete 1 hs01301202 concrete 2 hs01301203 concrete 3 hs01301204 concrete 4 hs01301205 concrete 5 hs01301206 concrete 6 hs01301207 concrete 7 hs01301208 concrete 8 hs01301209 concrete 9 hs01301210 concrete 10 hs01301211 concrete 11 hs01301300 -1 hs01301400 1 13 ext.5.5 hs01301401.800 equiv-band 1.88 hs01301500 237.4 3.900 3.900 hs01301600 0 -1 ext.5.5
- hs01301800 -1
- hs01301801 311.0 12
- hs_conf1 *
- Type = slab Appendix C 90
- Cell number = 13
- Heat struct = 2
- Geometry = floor
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 3.9 m hs01302000 12 1 1 hs01302001 hs_conf1 hs01302002 5.3000 -.1000E-06 hs01302003 1.
hs01302100 -1 1.0000 hs01302102.3500E-03 2 hs01302103.1000E-02 3 hs01302104.2000E-02 4 hs01302105.4000E-02 5 hs01302106.8000E-02 6 hs01302107.1600E-01 7 hs01302108.3000E-01 8 hs01302109.6000E-01 9 hs01302110.1200 10 hs01302111.2400 11 hs01302112.3600 12 hs01302200 -1 hs01302201 concrete 1 hs01302202 concrete 2 hs01302203 concrete 3 hs01302204 concrete 4 hs01302205 concrete 5 hs01302206 concrete 6 hs01302207 concrete 7 hs01302208 concrete 8 hs01302209 concrete 9 hs01302210 concrete 10 hs01302211 concrete 11 hs01302300 -1 hs01302400 1 13 ext.5.5 hs01302401.800 equiv-band 1.88 hs01302500 237.4 3.900 3.900 hs01302600 0 -1 ext.5.5
- hs01302800 -1
- hs01302801 311.0 12
- hs_conw1 *
- Type = slab
- Cell number = 13
- Heat struct = 3
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 7.0 m hs01303000 12 1 1 hs01303001 hs_conw1 hs01303002 5.3000 1.000 hs01303003 1.
Appendix C 91
hs01303100 -1 1.0000 hs01303102.3500E-03 2 hs01303103.1000E-02 3 hs01303104.2000E-02 4 hs01303105.4000E-02 5 hs01303106.8000E-02 6 hs01303107.1600E-01 7 hs01303108.3000E-01 8 hs01303109.6000E-01 9 hs01303110.1200 10 hs01303111.2400 11 hs01303112.3600 12 hs01303200 -1 hs01303201 concrete 1 hs01303202 concrete 2 hs01303203 concrete 3 hs01303204 concrete 4 hs01303205 concrete 5 hs01303206 concrete 6 hs01303207 concrete 7 hs01303208 concrete 8 hs01303209 concrete 9 hs01303210 concrete 10 hs01303211 concrete 11 hs01303300 -1 hs01303400 1 13 ext.5.5 hs01303401.800 equiv-band 1.88 hs01303500 690.2 7.000 7.000 hs01303600 0 -1 ext.5.5
- hs01303800 -1
- hs01303801 311.0 12
- HS did not fit inside of volume
- Cell height = 14.0000 m
- Reset to = 14.0000 m
- hs_stw13 *
- Type = slab
- Cell number = 13
- Heat struct = 4
- Geometry = wall
- HS elev. = 5.3000 m
- LHS Cell bottom = 5.3000 m
- LHS Cell top = 19.3000 m
- Cell height = 14. m
- Charact. length = 14. m hs01304000 9 1 1 hs01304001 hs_stw13 hs01304002 5.3000 1.000 hs01304003 1.
hs01304100 -1 1.0000 hs01304102.3500E-03 2 hs01304103.1000E-02 3 hs01304104.2000E-02 4 hs01304105.4000E-02 5 hs01304106.8000E-02 6 hs01304107.1300E-01 7 Appendix C 92
hs01304108.2100E-01 8 hs01304109.3100E-01 9 hs01304200 -1 hs01304201 'CARBON STEEL' 1 hs01304202 'CARBON STEEL' 2 hs01304203 'CARBON STEEL' 3 hs01304204 'CARBON STEEL' 4 hs01304205 'CARBON STEEL' 5 hs01304206 'CARBON STEEL' 6 hs01304207 'CARBON STEEL' 7 hs01304208 'CARBON STEEL' 8 hs01304300 -1 hs01304400 1 13 ext.5.5 hs01304401.800 equiv-band 1.88 hs01304500 656.0 14.00 14.00 hs01304600 0 -1 ext.5.5
- hs01304800 -1
- hs01304801 311.0 9
- hs_stw14 *
- Type = slab
- Cell number = 14
- Heat struct = 1
- Geometry = wall
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length = 2.5 m hs01401000 7 1 1 hs01401001 hs_stw14 hs01401002 17.750 1.000 hs01401003 1.
hs01401100 -1 1.0000 hs01401102.3500E-03 2 hs01401103.1000E-02 3 hs01401104.2000E-02 4 hs01401105.4000E-02 5 hs01401106.8000E-02 6 hs01401107.1300E-01 7 hs01401200 -1 hs01401201 'CARBON STEEL' 1 hs01401202 'CARBON STEEL' 2 hs01401203 'CARBON STEEL' 3 hs01401204 'CARBON STEEL' 4 hs01401205 'CARBON STEEL' 5 hs01401206 'CARBON STEEL' 6 hs01401300 -1 hs01401400 1 14 ext.5.5 hs01401401.800 equiv-band 0.76 hs01401500 70.00 2.500 2.500 hs01401600 0 -1 ext.5.5
- hs01401800 -1
- hs01401801 274.5 7
- hs_stw14
- Appendix C 93
- Type = slab
- Cell number = 14
- Heat struct = 2
- Geometry = wall
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length =.20 m hs01402000 7 1 1 hs01402001 hs_stw14 hs01402002 17.750 1.000 hs01402003 1.
hs01402100 -1 1.0000 hs01402102.3500E-03 2 hs01402103.1000E-02 3 hs01402104.2000E-02 4 hs01402105.4000E-02 5 hs01402106.6000E-02 6 hs01402107.8100E-02 7 hs01402200 -1 hs01402201 'CARBON STEEL' 1 hs01402202 'CARBON STEEL' 2 hs01402203 'CARBON STEEL' 3 hs01402204 'CARBON STEEL' 4 hs01402205 'CARBON STEEL' 5 hs01402206 'CARBON STEEL' 6 hs01402300 -1 hs01402400 1 14 ext.5.5 hs01402401.800 equiv-band 0.76 hs01402500 665.0.2000.2000 hs01402600 0 -1 ext.5.5
- hs01402800 -1
- hs01402801 274.5 7
- hs_conf1 *
- Type = slab
- Cell number = 14
- Heat struct = 3
- Geometry = floor
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length = 3.2 m hs01403000 13 1 1 hs01403001 hs_conf1 hs01403002 17.750 -.1000E-06 hs01403003 1.
hs01403100 -1 1.0000 hs01403102.3500E-03 2 hs01403103.1000E-02 3 hs01403104.2000E-02 4 hs01403105.4000E-02 5 hs01403106.8000E-02 6 hs01403107.1600E-01 7 hs01403108.3200E-01 8 hs01403109.6400E-01 9 Appendix C 94
hs01403110.1300 10 hs01403111.2600 11 hs01403112.5000 12 hs01403113.7500 13 hs01403200 -1 hs01403201 concrete 1 hs01403202 concrete 2 hs01403203 concrete 3 hs01403204 concrete 4 hs01403205 concrete 5 hs01403206 concrete 6 hs01403207 concrete 7 hs01403208 concrete 8 hs01403209 concrete 9 hs01403210 concrete 10 hs01403211 concrete 11 hs01403212 concrete 12 hs01403300 -1 hs01403400 1 14 ext.5.5 hs01403401.800 equiv-band 0.76 hs01403500 77.50 3.200 3.200 hs01403600 0 -1 ext.5.5
- hs01403800 -1
- hs01403801 274.5 13
- hs_stw15 *
- Type = slab
- Cell number = 15
- Heat struct = 1
- Geometry = wall
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length = 2.5 m hs01501000 7 1 1 hs01501001 hs_stw15 hs01501002 17.750 1.000 hs01501003 1.
hs01501100 -1 1.0000 hs01501102.3500E-03 2 hs01501103.1000E-02 3 hs01501104.2000E-02 4 hs01501105.4000E-02 5 hs01501106.8000E-02 6 hs01501107.1300E-01 7 hs01501200 -1 hs01501201 'CARBON STEEL' 1 hs01501202 'CARBON STEEL' 2 hs01501203 'CARBON STEEL' 3 hs01501204 'CARBON STEEL' 4 hs01501205 'CARBON STEEL' 5 hs01501206 'CARBON STEEL' 6 hs01501300 -1 hs01501400 1 15 ext.5.5 hs01501401.800 equiv-band 0.76 hs01501500 70.00 2.500 2.500 hs01501600 0 -1 ext.5.5 Appendix C 95
- hs01501800 -1
- hs01501801 274.5 7
- hs_stw15 *
- Type = slab
- Cell number = 15
- Heat struct = 2
- Geometry = wall
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length =.20 m hs01502000 7 1 1 hs01502001 hs_stw15 hs01502002 17.750 1.000 hs01502003 1.
hs01502100 -1 1.0000 hs01502102.3500E-03 2 hs01502103.1000E-02 3 hs01502104.2000E-02 4 hs01502105.4000E-02 5 hs01502106.6000E-02 6 hs01502107.8100E-02 7 hs01502200 -1 hs01502201 'CARBON STEEL' 1 hs01502202 'CARBON STEEL' 2 hs01502203 'CARBON STEEL' 3 hs01502204 'CARBON STEEL' 4 hs01502205 'CARBON STEEL' 5 hs01502206 'CARBON STEEL' 6 hs01502300 -1 hs01502400 1 15 ext.5.5 hs01502401.800 equiv-band 0.76 hs01502500 665.0.2000.2000 hs01502600 0 -1 ext.5.5
- hs01502800 -1
- hs01502801 274.5 7
- hs_conf1 *
- Type = slab
- Cell number = 15
- Heat struct = 3
- Geometry = floor
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length = 3.2 m hs01503000 13 1 1 hs01503001 hs_conf1 hs01503002 17.750 -.1000E-06 hs01503003 1.
hs01503100 -1 1.0000 hs01503102.3500E-03 2 Appendix C 96
hs01503103.1000E-02 3 hs01503104.2000E-02 4 hs01503105.4000E-02 5 hs01503106.8000E-02 6 hs01503107.1600E-01 7 hs01503108.3200E-01 8 hs01503109.6400E-01 9 hs01503110.1300 10 hs01503111.2600 11 hs01503112.5000 12 hs01503113.7500 13 hs01503200 -1 hs01503201 concrete 1 hs01503202 concrete 2 hs01503203 concrete 3 hs01503204 concrete 4 hs01503205 concrete 5 hs01503206 concrete 6 hs01503207 concrete 7 hs01503208 concrete 8 hs01503209 concrete 9 hs01503210 concrete 10 hs01503211 concrete 11 hs01503212 concrete 12 hs01503300 -1 hs01503400 1 15 ext.5.5 hs01503401.800 equiv-band 0.76 hs01503500 77.50 3.200 3.200 hs01503600 0 -1 ext.5.5
- hs01503800 -1
- hs01503801 274.5 13
- hs_stw16 *
- Type = slab
- Cell number = 16
- Heat struct = 1
- Geometry = wall
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length = 2.5 m hs01601000 7 1 1 hs01601001 hs_stw16 hs01601002 17.750 1.000 hs01601003 1.
hs01601100 -1 1.0000 hs01601102.3500E-03 2 hs01601103.1000E-02 3 hs01601104.2000E-02 4 hs01601105.4000E-02 5 hs01601106.8000E-02 6 hs01601107.1300E-01 7 hs01601200 -1 hs01601201 'CARBON STEEL' 1 hs01601202 'CARBON STEEL' 2 hs01601203 'CARBON STEEL' 3 hs01601204 'CARBON STEEL' 4 hs01601205 'CARBON STEEL' 5 Appendix C 97
hs01601206 'CARBON STEEL' 6 hs01601300 -1 hs01601400 1 16 ext.5.5 hs01601401.800 equiv-band 0.76 hs01601500 70.00 2.500 2.500 hs01601600 0 -1 ext.5.5
- hs01601800 -1
- hs01601801 274.5 7
- hs_stw16 *
- Type = slab
- Cell number = 16
- Heat struct = 2
- Geometry = wall
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length =.20 m hs01602000 7 1 1 hs01602001 hs_stw16 hs01602002 17.750 1.000 hs01602003 1.
hs01602100 -1 1.0000 hs01602102.3500E-03 2 hs01602103.1000E-02 3 hs01602104.2000E-02 4 hs01602105.4000E-02 5 hs01602106.6000E-02 6 hs01602107.8100E-02 7 hs01602200 -1 hs01602201 'CARBON STEEL' 1 hs01602202 'CARBON STEEL' 2 hs01602203 'CARBON STEEL' 3 hs01602204 'CARBON STEEL' 4 hs01602205 'CARBON STEEL' 5 hs01602206 'CARBON STEEL' 6 hs01602300 -1 hs01602400 1 16 ext.5.5 hs01602401.800 equiv-band 0.76 hs01602500 665.0.2000.2000 hs01602600 0 -1 ext.5.5
- hs01602800 -1
- hs01602801 274.5 7
- hs_conf1 *
- Type = slab
- Cell number = 16
- Heat struct = 3
- Geometry = floor
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length = 3.2 m Appendix C 98
hs01603000 13 1 1 hs01603001 hs_conf1 hs01603002 17.750 -.1000E-06 hs01603003 1.
hs01603100 -1 1.0000 hs01603102.3500E-03 2 hs01603103.1000E-02 3 hs01603104.2000E-02 4 hs01603105.4000E-02 5 hs01603106.8000E-02 6 hs01603107.1600E-01 7 hs01603108.3200E-01 8 hs01603109.6400E-01 9 hs01603110.1300 10 hs01603111.2600 11 hs01603112.5000 12 hs01603113.7500 13 hs01603200 -1 hs01603201 concrete 1 hs01603202 concrete 2 hs01603203 concrete 3 hs01603204 concrete 4 hs01603205 concrete 5 hs01603206 concrete 6 hs01603207 concrete 7 hs01603208 concrete 8 hs01603209 concrete 9 hs01603210 concrete 10 hs01603211 concrete 11 hs01603212 concrete 12 hs01603300 -1 hs01603400 1 16 ext.5.5 hs01603401.800 equiv-band 0.76 hs01603500 77.50 3.200 3.200 hs01603600 0 -1 ext.5.5
- hs01603800 -1
- hs01603801 274.5 13
- hs_stw17 *
- Type = slab
- Cell number = 17
- Heat struct = 1
- Geometry = wall
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length = 2.5 m hs01701000 7 1 1 hs01701001 hs_stw17 hs01701002 17.750 1.000 hs01701003 1.
hs01701100 -1 1.0000 hs01701102.3500E-03 2 hs01701103.1000E-02 3 hs01701104.2000E-02 4 hs01701105.4000E-02 5 hs01701106.8000E-02 6 Appendix C 99
hs01701107.1300E-01 7 hs01701200 -1 hs01701201 'CARBON STEEL' 1 hs01701202 'CARBON STEEL' 2 hs01701203 'CARBON STEEL' 3 hs01701204 'CARBON STEEL' 4 hs01701205 'CARBON STEEL' 5 hs01701206 'CARBON STEEL' 6 hs01701300 -1 hs01701400 1 17 ext.5.5 hs01701401.800 equiv-band 0.76 hs01701500 70.00 2.500 2.500 hs01701600 0 -1 ext.5.5
- hs01701800 -1
- hs01701801 274.5 7
- hs_stw17 *
- Type = slab
- Cell number = 17
- Heat struct = 2
- Geometry = wall
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length =.20 m hs01702000 7 1 1 hs01702001 hs_stw17 hs01702002 17.750 1.000 hs01702003 1.
hs01702100 -1 1.0000 hs01702102.3500E-03 2 hs01702103.1000E-02 3 hs01702104.2000E-02 4 hs01702105.4000E-02 5 hs01702106.6000E-02 6 hs01702107.8100E-02 7 hs01702200 -1 hs01702201 'CARBON STEEL' 1 hs01702202 'CARBON STEEL' 2 hs01702203 'CARBON STEEL' 3 hs01702204 'CARBON STEEL' 4 hs01702205 'CARBON STEEL' 5 hs01702206 'CARBON STEEL' 6 hs01702300 -1 hs01702400 1 17 ext.5.5 hs01702401.800 equiv-band 0.76 hs01702500 665.0.2000.2000 hs01702600 0 -1 ext.5.5
- hs01702800 -1
- hs01702801 274.5 7
- hs_conf1 *
- Type = slab
- Cell number = 17
- Heat struct = 3 Appendix C 100
- Geometry = floor
- HS elev. = 17.7500 m
- LHS Cell bottom = 17.7500 m
- LHS Cell top = 20.2500 m
- Cell height = 2.5 m
- Charact. length = 3.2 m hs01703000 13 1 1 hs01703001 hs_conf1 hs01703002 17.750 -.1000E-06 hs01703003 1.
hs01703100 -1 1.0000 hs01703102.3500E-03 2 hs01703103.1000E-02 3 hs01703104.2000E-02 4 hs01703105.4000E-02 5 hs01703106.8000E-02 6 hs01703107.1600E-01 7 hs01703108.3200E-01 8 hs01703109.6400E-01 9 hs01703110.1300 10 hs01703111.2600 11 hs01703112.5000 12 hs01703113.7500 13 hs01703200 -1 hs01703201 concrete 1 hs01703202 concrete 2 hs01703203 concrete 3 hs01703204 concrete 4 hs01703205 concrete 5 hs01703206 concrete 6 hs01703207 concrete 7 hs01703208 concrete 8 hs01703209 concrete 9 hs01703210 concrete 10 hs01703211 concrete 11 hs01703212 concrete 12 hs01703300 -1 hs01703400 1 17 ext.5.5 hs01703401.800 equiv-band 0.76 hs01703500 77.50 3.200 3.200 hs01703600 0 -1 ext.5.5
- hs01703800 -1
- hs01703801 274.5 13
- hs_stf18 *
- Type = slab
- Cell number = 18
- Heat struct = 1
- Geometry = floor
- HS elev. = 20.4000 m
- LHS Cell bottom = 20.4000 m
- LHS Cell top = 35.0000 m
- Cell height = 15. m
- Charact. length = 3.0 m hs01801000 4 1 1 hs01801001 hs_stf18 hs01801002 20.400 -.1000E-06 Appendix C 101
hs01801003 1.
hs01801100 -1 1.0000 hs01801102.3500E-03 2 hs01801103.1000E-02 3 hs01801104.2000E-02 4 hs01801200 -1 hs01801201 'CARBON STEEL' 1 hs01801202 'CARBON STEEL' 2 hs01801203 'CARBON STEEL' 3 hs01801300 -1 hs01801400 1 18 ext.5.5 hs01801401.800 equiv-band 0.76 hs01801500 40.75 3.000 3.000 hs01801600 0 -1 ext.5.5
- hs01801800 -1
- hs01801801 274.5 4
- HS did not fit inside of volume
- Cell height = 14.6000 m
- Reset to = 14.6000 m
- hs_stw18 *
- Type = slab
- Cell number = 18
- Heat struct = 2
- Geometry = wall
- HS elev. = 20.4000 m
- LHS Cell bottom = 20.4000 m
- LHS Cell top = 35.0000 m
- Cell height = 15. m
- Charact. length = 15. m hs01802000 7 1 1 hs01802001 hs_stw18 hs01802002 20.400 1.000 hs01802003 1.
hs01802100 -1 1.0000 hs01802102.3500E-03 2 hs01802103.1000E-02 3 hs01802104.2000E-02 4 hs01802105.4000E-02 5 hs01802106.8000E-02 6 hs01802107.1220E-01 7 hs01802200 -1 hs01802201 'CARBON STEEL' 1 hs01802202 'CARBON STEEL' 2 hs01802203 'CARBON STEEL' 3 hs01802204 'CARBON STEEL' 4 hs01802205 'CARBON STEEL' 5 hs01802206 'CARBON STEEL' 6 hs01802300 -1 hs01802400 1 18 ext.5.5 hs01802401.800 equiv-band 0.326 hs01802500 514.5 14.60 14.60 hs01802600 0 -1 ext.5.5
- hs01802800 -1
- hs01802801 274.5 7 Appendix C 102
- hs_stf19 *
- Type = slab
- Cell number = 19
- Heat struct = 1
- Geometry = floor
- HS elev. = 20.4000 m
- LHS Cell bottom = 20.4000 m
- LHS Cell top = 35.0000 m
- Cell height = 15. m
- Charact. length = 3.0 m hs01901000 4 1 1 hs01901001 hs_stf19 hs01901002 20.400 -.1000E-06 hs01901003 1.
hs01901100 -1 1.0000 hs01901102.3500E-03 2 hs01901103.1000E-02 3 hs01901104.2000E-02 4 hs01901200 -1 hs01901201 'CARBON STEEL' 1 hs01901202 'CARBON STEEL' 2 hs01901203 'CARBON STEEL' 3 hs01901300 -1 hs01901400 1 19 ext.5.5 hs01901401.800 equiv-band 0.326 hs01901500 40.75 3.000 3.000 hs01901600 0 -1 ext.5.5
- hs01901800 -1
- hs01901801 274.5 4
- HS did not fit inside of volume
- Cell height = 14.6000 m
- Reset to = 14.6000 m
- hs_stw19 *
- Type = slab
- Cell number = 19
- Heat struct = 2
- Geometry = wall
- HS elev. = 20.4000 m
- LHS Cell bottom = 20.4000 m
- LHS Cell top = 35.0000 m
- Cell height = 15. m
- Charact. length = 15. m hs01902000 7 1 1 hs01902001 hs_stw19 hs01902002 20.400 1.000 hs01902003 1.
hs01902100 -1 1.0000 hs01902102.3500E-03 2 hs01902103.1000E-02 3 hs01902104.2000E-02 4 hs01902105.4000E-02 5 hs01902106.8000E-02 6 Appendix C 103
hs01902107.1220E-01 7 hs01902200 -1 hs01902201 'CARBON STEEL' 1 hs01902202 'CARBON STEEL' 2 hs01902203 'CARBON STEEL' 3 hs01902204 'CARBON STEEL' 4 hs01902205 'CARBON STEEL' 5 hs01902206 'CARBON STEEL' 6 hs01902300 -1 hs01902400 1 19 ext.5.5 hs01902401.800 equiv-band 0.326 hs01902500 514.5 14.60 14.60 hs01902600 0 -1 ext.5.5
- hs01902800 -1
- hs01902801 274.5 7
- hs_stf20 *
- Type = slab
- Cell number = 20
- Heat struct = 1
- Geometry = floor
- HS elev. = 20.4000 m
- LHS Cell bottom = 20.4000 m
- LHS Cell top = 35.0000 m
- Cell height = 15. m
- Charact. length = 3.0 m hs02001000 4 1 1 hs02001001 hs_stf20 hs02001002 20.400 -.1000E-06 hs02001003 1.
hs02001100 -1 1.0000 hs02001102.3500E-03 2 hs02001103.1000E-02 3 hs02001104.2000E-02 4 hs02001200 -1 hs02001201 'CARBON STEEL' 1 hs02001202 'CARBON STEEL' 2 hs02001203 'CARBON STEEL' 3 hs02001300 -1 hs02001400 1 20 ext.5.5 hs02001401.800 equiv-band 0.326 hs02001500 40.75 3.000 3.000 hs02001600 0 -1 ext.5.5
- hs02001800 -1
- hs02001801 274.5 4
- HS did not fit inside of volume
- Cell height = 14.6000 m
- Reset to = 14.6000 m
- hs_stw20 *
- Type = slab
- Cell number = 20
- Heat struct = 2 Appendix C 104
- Geometry = wall
- HS elev. = 20.4000 m
- LHS Cell bottom = 20.4000 m
- LHS Cell top = 35.0000 m
- Cell height = 15. m
- Charact. length = 15. m hs02002000 7 1 1 hs02002001 hs_stw20 hs02002002 20.400 1.000 hs02002003 1.
hs02002100 -1 1.0000 hs02002102.3500E-03 2 hs02002103.1000E-02 3 hs02002104.2000E-02 4 hs02002105.4000E-02 5 hs02002106.8000E-02 6 hs02002107.1220E-01 7 hs02002200 -1 hs02002201 'CARBON STEEL' 1 hs02002202 'CARBON STEEL' 2 hs02002203 'CARBON STEEL' 3 hs02002204 'CARBON STEEL' 4 hs02002205 'CARBON STEEL' 5 hs02002206 'CARBON STEEL' 6 hs02002300 -1 hs02002400 1 20 ext.5.5 hs02002401.800 equiv-band 0.326 hs02002500 514.5 14.60 14.60 hs02002600 0 -1 ext.5.5
- hs02002800 -1
- hs02002801 274.5 7
- hs_stf21 *
- Type = slab
- Cell number = 21
- Heat struct = 1
- Geometry = floor
- HS elev. = 20.4000 m
- LHS Cell bottom = 20.4000 m
- LHS Cell top = 35.0000 m
- Cell height = 15. m
- Charact. length = 3.0 m hs02101000 4 1 1 hs02101001 hs_stf21 hs02101002 20.400 -.1000E-06 hs02101003 1.
hs02101100 -1 1.0000 hs02101102.3500E-03 2 hs02101103.1000E-02 3 hs02101104.2000E-02 4 hs02101200 -1 hs02101201 'CARBON STEEL' 1 hs02101202 'CARBON STEEL' 2 hs02101203 'CARBON STEEL' 3 hs02101300 -1 hs02101400 1 21 ext.5.5 hs02101401.800 equiv-band 0.326 hs02101500 40.75 3.000 3.000 Appendix C 105
hs02101600 0 -1 ext.5.5
- hs02101800 -1
- hs02101801 274.5 4
- HS did not fit inside of volume
- Cell height = 14.6000 m
- Reset to = 14.6000 m
- hs_stw21 *
- Type = slab
- Cell number = 21
- Heat struct = 2
- Geometry = wall
- HS elev. = 20.4000 m
- LHS Cell bottom = 20.4000 m
- LHS Cell top = 35.0000 m
- Cell height = 15. m
- Charact. length = 15. m hs02102000 7 1 1 hs02102001 hs_stw21 hs02102002 20.400 1.000 hs02102003 1.
hs02102100 -1 1.0000 hs02102102.3500E-03 2 hs02102103.1000E-02 3 hs02102104.2000E-02 4 hs02102105.4000E-02 5 hs02102106.8000E-02 6 hs02102107.1220E-01 7 hs02102200 -1 hs02102201 'CARBON STEEL' 1 hs02102202 'CARBON STEEL' 2 hs02102203 'CARBON STEEL' 3 hs02102204 'CARBON STEEL' 4 hs02102205 'CARBON STEEL' 5 hs02102206 'CARBON STEEL' 6 hs02102300 -1 hs02102400 1 21 ext.5.5 hs02102401.800 equiv-band 0.326 hs02102500 514.5 14.60 14.60 hs02102600 0 -1 ext.5.5
- hs02102800 -1
- hs02102801 274.5 7
- hs_stf22 *
- Type = slab
- Cell number = 22
- Heat struct = 1
- Geometry = floor
- HS elev. = 35.1000 m
- LHS Cell bottom = 35.1000 m
- LHS Cell top = 40.1000 m
- Cell height = 5.0 m
- Charact. length = 3.5 m Appendix C 106
hs02201000 7 1 1 hs02201001 hs_stf22 hs02201002 35.100 -.1000E-06 hs02201003 1.
hs02201100 -1 1.0000 hs02201102.3500E-03 2 hs02201103.1000E-02 3 hs02201104.2000E-02 4 hs02201105.4000E-02 5 hs02201106.8000E-02 6 hs02201107.1300E-01 7 hs02201200 -1 hs02201201 'CARBON STEEL' 1 hs02201202 'CARBON STEEL' 2 hs02201203 'CARBON STEEL' 3 hs02201204 'CARBON STEEL' 4 hs02201205 'CARBON STEEL' 5 hs02201206 'CARBON STEEL' 6 hs02201300 -1 hs02201400 1 22 ext.5.5 hs02201401.800 equiv-band 3.78 hs02201500 133.0 3.500 3.500 hs02201600 0 -1 ext.5.5
- hs02201800 -1
- hs02201801 274.5 7
- hs_stw22 *
- Type = slab
- Cell number = 22
- Heat struct = 2
- Geometry = wall
- HS elev. = 35.1000 m
- LHS Cell bottom = 35.1000 m
- LHS Cell top = 40.1000 m
- Cell height = 5.0 m
- Charact. length = 5.0 m hs02202000 7 1 1 hs02202001 hs_stw22 hs02202002 35.100 1.000 hs02202003 1.
hs02202100 -1 1.0000 hs02202102.3500E-03 2 hs02202103.1000E-02 3 hs02202104.2000E-02 4 hs02202105.4000E-02 5 hs02202106.8000E-02 6 hs02202107.1300E-01 7 hs02202200 -1 hs02202201 'CARBON STEEL' 1 hs02202202 'CARBON STEEL' 2 hs02202203 'CARBON STEEL' 3 hs02202204 'CARBON STEEL' 4 hs02202205 'CARBON STEEL' 5 hs02202206 'CARBON STEEL' 6 hs02202300 -1 hs02202400 1 22 ext.5.5 hs02202401.800 equiv-band 3.78 hs02202500 500.0 5.000 5.000 hs02202600 0 -1 ext.5.5 Appendix C 107
- hs02202800 -1
- hs02202801 274.5 7
- hs_stf23 *
- Type = slab
- Cell number = 23
- Heat struct = 1
- Geometry = floor
- HS elev. = 35.1000 m
- LHS Cell bottom = 35.1000 m
- LHS Cell top = 40.1000 m
- Cell height = 5.0 m
- Charact. length = 3.5 m hs02301000 7 1 1 hs02301001 hs_stf23 hs02301002 35.100 -.1000E-06 hs02301003 1.
hs02301100 -1 1.0000 hs02301102.3500E-03 2 hs02301103.1000E-02 3 hs02301104.2000E-02 4 hs02301105.4000E-02 5 hs02301106.8000E-02 6 hs02301107.1300E-01 7 hs02301200 -1 hs02301201 'CARBON STEEL' 1 hs02301202 'CARBON STEEL' 2 hs02301203 'CARBON STEEL' 3 hs02301204 'CARBON STEEL' 4 hs02301205 'CARBON STEEL' 5 hs02301206 'CARBON STEEL' 6 hs02301300 -1 hs02301400 1 23 ext.5.5 hs02301401.800 equiv-band 3.78 hs02301500 133.0 3.500 3.500 hs02301600 0 -1 ext.5.5
- hs02301800 -1
- hs02301801 274.5 7
- hs_stw23 *
- Type = slab
- Cell number = 23
- Heat struct = 2
- Geometry = wall
- HS elev. = 35.1000 m
- LHS Cell bottom = 35.1000 m
- LHS Cell top = 40.1000 m
- Cell height = 5.0 m
- Charact. length = 5.0 m hs02302000 7 1 1 hs02302001 hs_stw23 hs02302002 35.100 1.000 hs02302003 1.
hs02302100 -1 1.0000 hs02302102.3500E-03 2 Appendix C 108
hs02302103.1000E-02 3 hs02302104.2000E-02 4 hs02302105.4000E-02 5 hs02302106.8000E-02 6 hs02302107.1300E-01 7 hs02302200 -1 hs02302201 'CARBON STEEL' 1 hs02302202 'CARBON STEEL' 2 hs02302203 'CARBON STEEL' 3 hs02302204 'CARBON STEEL' 4 hs02302205 'CARBON STEEL' 5 hs02302206 'CARBON STEEL' 6 hs02302300 -1 hs02302400 1 23 ext.5.5 hs02302401.800 equiv-band 3.78 hs02302500 500.0 5.000 5.000 hs02302600 0 -1 ext.5.5
- hs02302800 -1
- hs02302801 274.5 7
- hs_str24 *
- Type = slab
- Cell number = 24
- Heat struct = 1
- Geometry = roof
- HS elev. = 54.7000 m
- LHS Cell bottom = 33.7000 m
- LHS Cell top = 54.7000 m
- Cell height = 21. m
- Charact. length = 18. m hs02401000 7 1 1 hs02401001 hs_str24 hs02401002 54.700.0000 hs02401003 1.
hs02401100 -1 1.0000 hs02401102.3500E-03 2 hs02401103.1000E-02 3 hs02401104.2000E-02 4 hs02401105.4000E-02 5 hs02401106.8000E-02 6 hs02401107.1270E-01 7 hs02401200 -1 hs02401201 'CARBON STEEL' 1 hs02401202 'CARBON STEEL' 2 hs02401203 'CARBON STEEL' 3 hs02401204 'CARBON STEEL' 4 hs02401205 'CARBON STEEL' 5 hs02401206 'CARBON STEEL' 6 hs02401300 -1 hs02401400 1 24 ext.5.5 hs02401401.800 equiv-band 10.40 hs02401500 881.0 17.50 17.50 hs02401600 0 -1 ext.5.5
- hs02401800 -1
- hs02401801 303.0 7
- hs_stw24
- Appendix C 109
- Type = slab
- Cell number = 24
- Heat struct = 2
- Geometry = wall
- HS elev. = 33.7000 m
- LHS Cell bottom = 33.7000 m
- LHS Cell top = 54.7000 m
- Cell height = 21. m
- Charact. length = 8.0 m hs02402000 7 1 1 hs02402001 hs_stw24 hs02402002 33.700 1.000 hs02402003 1.
hs02402100 -1 1.0000 hs02402102.3500E-03 2 hs02402103.1000E-02 3 hs02402104.2000E-02 4 hs02402105.4000E-02 5 hs02402106.8000E-02 6 hs02402107.1300E-01 7 hs02402200 -1 hs02402201 'CARBON STEEL' 1 hs02402202 'CARBON STEEL' 2 hs02402203 'CARBON STEEL' 3 hs02402204 'CARBON STEEL' 4 hs02402205 'CARBON STEEL' 5 hs02402206 'CARBON STEEL' 6 hs02402300 -1 hs02402400 1 24 ext.5.5 hs02402401.800 equiv-band 10.40 hs02402500 910.0 8.000 8.000 hs02402600 0 -1 ext.5.5
- hs02402800 -1
- hs02402801 303.0 7
- hs_stf24 *
- Type = slab
- Cell number = 24
- Heat struct = 3
- Geometry = floor
- HS elev. = 33.7000 m
- LHS Cell bottom = 33.7000 m
- LHS Cell top = 54.7000 m
- Cell height = 21. m
- Charact. length = 3.7 m hs02403000 7 1 1 hs02403001 hs_stf24 hs02403002 33.700 -.1000E-06 hs02403003 1.
hs02403100 -1 1.0000 hs02403102.3500E-03 2 hs02403103.1000E-02 3 hs02403104.2000E-02 4 hs02403105.4000E-02 5 hs02403106.8000E-02 6 hs02403107.1300E-01 7 hs02403200 -1 Appendix C 110
hs02403201 'CARBON STEEL' 1 hs02403202 'CARBON STEEL' 2 hs02403203 'CARBON STEEL' 3 hs02403204 'CARBON STEEL' 4 hs02403205 'CARBON STEEL' 5 hs02403206 'CARBON STEEL' 6 hs02403300 -1 hs02403400 1 24 ext.5.5 hs02403401.800 equiv-band 10.40 hs02403500 90.00 3.700 3.700 hs02403600 0 -1 ext.5.5
- hs02403800 -1
- hs02403801 303.0 7
- hs_conw2 *
- Type = slab
- Cell number = 24
- Heat struct = 4
- Geometry = wall
- HS elev. = 33.7000 m
- LHS Cell bottom = 33.7000 m
- LHS Cell top = 54.7000 m
- Cell height = 21. m
- Charact. length = 5.5 m hs02404000 13 1 1 hs02404001 hs_conw2 hs02404002 33.700 1.000 hs02404003 1.
hs02404100 -1 1.0000 hs02404102.3500E-03 2 hs02404103.1000E-02 3 hs02404104.2000E-02 4 hs02404105.4000E-02 5 hs02404106.8000E-02 6 hs02404107.1600E-01 7 hs02404108.3000E-01 8 hs02404109.6000E-01 9 hs02404110.1200 10 hs02404111.2400 11 hs02404112.4800 12 hs02404113.9100 13 hs02404200 -1 hs02404201 concrete 1 hs02404202 concrete 2 hs02404203 concrete 3 hs02404204 concrete 4 hs02404205 concrete 5 hs02404206 concrete 6 hs02404207 concrete 7 hs02404208 concrete 8 hs02404209 concrete 9 hs02404210 concrete 10 hs02404211 concrete 11 hs02404212 concrete 12 hs02404300 -1 hs02404400 1 24 ext.5.5 hs02404401.800 equiv-band 10.40 hs02404500 217.5 5.500 5.500 Appendix C 111
hs02404600 0 -1 ext.5.5
- hs02404800 -1
- hs02404801 303.0 13
- hs_conf2 *
- Type = slab
- Cell number = 24
- Heat struct = 5
- Geometry = floor
- HS elev. = 33.7000 m
- LHS Cell bottom = 33.7000 m
- LHS Cell top = 54.7000 m
- Cell height = 21. m
- Charact. length = 10. m hs02405000 13 1 1 hs02405001 hs_conf2 hs02405002 33.700 -.1000E-06 hs02405003 1.
hs02405100 -1 1.0000 hs02405102.3500E-03 2 hs02405103.1000E-02 3 hs02405104.2000E-02 4 hs02405105.4000E-02 5 hs02405106.8000E-02 6 hs02405107.1600E-01 7 hs02405108.3000E-01 8 hs02405109.6000E-01 9 hs02405110.1200 10 hs02405111.2400 11 hs02405112.4800 12 hs02405113.9100 13 hs02405200 -1 hs02405201 concrete 1 hs02405202 concrete 2 hs02405203 concrete 3 hs02405204 concrete 4 hs02405205 concrete 5 hs02405206 concrete 6 hs02405207 concrete 7 hs02405208 concrete 8 hs02405209 concrete 9 hs02405210 concrete 10 hs02405211 concrete 11 hs02405212 concrete 12 hs02405300 -1 hs02405400 1 24 ext.5.5 hs02405401.800 equiv-band 10.40 hs02405500 107.0 10.00 10.00 hs02405600 0 -1 ext.5.5
- hs02405800 -1
- hs02405801 303.0 13
- hs_str25 *
- Type = slab
- Cell number = 25
- Heat struct = 1 Appendix C 112
- Geometry = roof
- HS elev. = 54.7000 m
- LHS Cell bottom = 33.7000 m
- LHS Cell top = 54.7000 m
- Cell height = 21. m
- Charact. length = 18. m hs02501000 7 1 1 hs02501001 hs_str25 hs02501002 54.700.0000 hs02501003 1.
hs02501100 -1 1.0000 hs02501102.3500E-03 2 hs02501103.1000E-02 3 hs02501104.2000E-02 4 hs02501105.4000E-02 5 hs02501106.8000E-02 6 hs02501107.1270E-01 7 hs02501200 -1 hs02501201 'CARBON STEEL' 1 hs02501202 'CARBON STEEL' 2 hs02501203 'CARBON STEEL' 3 hs02501204 'CARBON STEEL' 4 hs02501205 'CARBON STEEL' 5 hs02501206 'CARBON STEEL' 6 hs02501300 -1 hs02501400 1 25 ext.5.5 hs02501401.800 equiv-band 10.40 hs02501500 881.0 17.50 17.50 hs02501600 0 -1 ext.5.5
- hs02501800 -1
- hs02501801 303.0 7
- hs_stw25 *
- Type = slab
- Cell number = 25
- Heat struct = 2
- Geometry = wall
- HS elev. = 33.7000 m
- LHS Cell bottom = 33.7000 m
- LHS Cell top = 54.7000 m
- Cell height = 21. m
- Charact. length = 8.0 m hs02502000 7 1 1 hs02502001 hs_stw25 hs02502002 33.700 1.000 hs02502003 1.
hs02502100 -1 1.0000 hs02502102.3500E-03 2 hs02502103.1000E-02 3 hs02502104.2000E-02 4 hs02502105.4000E-02 5 hs02502106.8000E-02 6 hs02502107.1300E-01 7 hs02502200 -1 hs02502201 'CARBON STEEL' 1 hs02502202 'CARBON STEEL' 2 hs02502203 'CARBON STEEL' 3 hs02502204 'CARBON STEEL' 4 Appendix C 113
hs02502205 'CARBON STEEL' 5 hs02502206 'CARBON STEEL' 6 hs02502300 -1 hs02502400 1 25 ext.5.5 hs02502401.800 equiv-band 10.40 hs02502500 910.0 8.000 8.000 hs02502600 0 -1 ext.5.5
- hs02502800 -1
- hs02502801 303.0 7
- hs_stf25 *
- Type = slab
- Cell number = 25
- Heat struct = 3
- Geometry = floor
- HS elev. = 33.7000 m
- LHS Cell bottom = 33.7000 m
- LHS Cell top = 54.7000 m
- Cell height = 21. m
- Charact. length = 3.7 m hs02503000 7 1 1 hs02503001 hs_stf25 hs02503002 33.700 -.1000E-06 hs02503003 1.
hs02503100 -1 1.0000 hs02503102.3500E-03 2 hs02503103.1000E-02 3 hs02503104.2000E-02 4 hs02503105.4000E-02 5 hs02503106.8000E-02 6 hs02503107.1300E-01 7 hs02503200 -1 hs02503201 'CARBON STEEL' 1 hs02503202 'CARBON STEEL' 2 hs02503203 'CARBON STEEL' 3 hs02503204 'CARBON STEEL' 4 hs02503205 'CARBON STEEL' 5 hs02503206 'CARBON STEEL' 6 hs02503300 -1 hs02503400 1 25 ext.5.5 hs02503401.800 equiv-band 10.40 hs02503500 90.00 3.700 3.700 hs02503600 0 -1 ext.5.5
- hs02503800 -1
- hs02503801 303.0 7
- hs_conw2 *
- Type = slab
- Cell number = 25
- Heat struct = 4
- Geometry = wall
- HS elev. = 33.7000 m
- LHS Cell bottom = 33.7000 m
- LHS Cell top = 54.7000 m
- Cell height = 21. m
- Charact. length = 5.5 m Appendix C 114
hs02504000 13 1 1 hs02504001 hs_conw2 hs02504002 33.700 1.000 hs02504003 1.
hs02504100 -1 1.0000 hs02504102.3500E-03 2 hs02504103.1000E-02 3 hs02504104.2000E-02 4 hs02504105.4000E-02 5 hs02504106.8000E-02 6 hs02504107.1600E-01 7 hs02504108.3000E-01 8 hs02504109.6000E-01 9 hs02504110.1200 10 hs02504111.2400 11 hs02504112.4800 12 hs02504113.9100 13 hs02504200 -1 hs02504201 concrete 1 hs02504202 concrete 2 hs02504203 concrete 3 hs02504204 concrete 4 hs02504205 concrete 5 hs02504206 concrete 6 hs02504207 concrete 7 hs02504208 concrete 8 hs02504209 concrete 9 hs02504210 concrete 10 hs02504211 concrete 11 hs02504212 concrete 12 hs02504300 -1 hs02504400 1 25 ext.5.5 hs02504401.800 equiv-band 10.40 hs02504500 217.5 5.500 5.500 hs02504600 0 -1 ext.5.5
- hs02504800 -1
- hs02504801 303.0 13
- hs_conf2 *
- Type = slab
- Cell number = 25
- Heat struct = 5
- Geometry = floor
- HS elev. = 33.7000 m
- LHS Cell bottom = 33.7000 m
- LHS Cell top = 54.7000 m
- Cell height = 21. m
- Charact. length = 10. m hs02505000 13 1 1 hs02505001 hs_conf2 hs02505002 33.700 -.1000E-06 hs02505003 1.
hs02505100 -1 1.0000 hs02505102.3500E-03 2 hs02505103.1000E-02 3 hs02505104.2000E-02 4 hs02505105.4000E-02 5 hs02505106.8000E-02 6 Appendix C 115
hs02505107.1600E-01 7 hs02505108.3000E-01 8 hs02505109.6000E-01 9 hs02505110.1200 10 hs02505111.2400 11 hs02505112.4800 12 hs02505113.9100 13 hs02505200 -1 hs02505201 concrete 1 hs02505202 concrete 2 hs02505203 concrete 3 hs02505204 concrete 4 hs02505205 concrete 5 hs02505206 concrete 6 hs02505207 concrete 7 hs02505208 concrete 8 hs02505209 concrete 9 hs02505210 concrete 10 hs02505211 concrete 11 hs02505212 concrete 12 hs02505300 -1 hs02505400 1 25 ext.5.5 hs02505401.800 equiv-band 10.40 hs02505500 107.0 10.00 10.00 hs02505600 0 -1 ext.5.5
- hs02505800 -1
- hs02505801 303.0 13
- hs_conw2 *
- Type = slab
- Cell number = 26
- Heat struct = 1
- Geometry = wall
- HS elev. = 17.9000 m
- LHS Cell bottom = 17.9000 m
- LHS Cell top = 34.1000 m
- Cell height = 16. m
- Charact. length = 14. m hs02601000 13 1 1 hs02601001 hs_conw2 hs02601002 17.900 1.000 hs02601003 1.
hs02601100 -1 1.0000 hs02601102.3500E-03 2 hs02601103.1000E-02 3 hs02601104.2000E-02 4 hs02601105.4000E-02 5 hs02601106.8000E-02 6 hs02601107.1600E-01 7 hs02601108.3000E-01 8 hs02601109.6000E-01 9 hs02601110.1200 10 hs02601111.2400 11 hs02601112.4800 12 hs02601113.9100 13 hs02601200 -1 hs02601201 concrete 1 hs02601202 concrete 2 hs02601203 concrete 3 Appendix C 116
hs02601204 concrete 4 hs02601205 concrete 5 hs02601206 concrete 6 hs02601207 concrete 7 hs02601208 concrete 8 hs02601209 concrete 9 hs02601210 concrete 10 hs02601211 concrete 11 hs02601212 concrete 12 hs02601300 -1 hs02601400 1 26 ext.5.5 hs02601401.800 equiv-band 9.21 hs02601500 1884. 14.00 14.00 hs02601600 0 -1 ext.5.5
- hs02601800 -1
- hs02601801 303.0 13
- hs_conf2 *
- Type = slab
- Cell number = 26
- Heat struct = 2
- Geometry = floor
- HS elev. = 17.9000 m
- LHS Cell bottom = 17.9000 m
- LHS Cell top = 34.1000 m
- Cell height = 16. m
- Charact. length = 10. m hs02602000 13 1 1 hs02602001 hs_conf2 hs02602002 17.900 -.1000E-06 hs02602003 1.
hs02602100 -1 1.0000 hs02602102.3500E-03 2 hs02602103.1000E-02 3 hs02602104.2000E-02 4 hs02602105.4000E-02 5 hs02602106.8000E-02 6 hs02602107.1600E-01 7 hs02602108.3000E-01 8 hs02602109.6000E-01 9 hs02602110.1200 10 hs02602111.2400 11 hs02602112.4800 12 hs02602113.9100 13 hs02602200 -1 hs02602201 concrete 1 hs02602202 concrete 2 hs02602203 concrete 3 hs02602204 concrete 4 hs02602205 concrete 5 hs02602206 concrete 6 hs02602207 concrete 7 hs02602208 concrete 8 hs02602209 concrete 9 hs02602210 concrete 10 hs02602211 concrete 11 hs02602212 concrete 12 hs02602300 -1 hs02602400 1 26 ext.5.5 Appendix C 117
hs02602401.800 equiv-band 9.21 hs02602500 403.0 10.00 10.00 hs02602600 0 -1 ext.5.5
- hs02602800 -1
- hs02602801 303.0 13
- HS Input to Model Ice in Baskets
- HS numbering is: HSacvnn, where,
- a = 9 (identifies hs as ice)
- cv = cv number for ice condensor
- nn = counter
- Typical models for PWR ice condensors suggest using a cylindrical geometry
- with outer radius of 15 cm.
- Calculate geometry based on Sequoyah CONTAIN Input of:
- Total Ice Bed Mass = 2.775e5 kg/compartment (total of 4)
- Height of Ice Bed = 14.53 m
- Surface Area of Ice Bed = 6200.0 m2
- Define:
- z = multiplicity
- h = height of ice bed (14.53 m)
- m = mass of ice bed (2.775e5 kg)
- a = surface area of ice bed (6200. m2)
- v = Total volume of ice (m3)
- r = radius of cylindrical heat structure (0.15 m)
- p = density of granulated ice (kg/m3)
- a = z
- 2
- pi
- r
- h, solve for z
- z = 6200. / (2
- pi
- 0.15
- 14.53) = 452.75
- v = m / p = z
- h
- pi
- r
- r
- solve for p
- p = 2.775e5 / (452.75
- 14.53
- pi
- 0.15
- 0.15) = 596.77 kg/m3
- Radiation emmissivity and path length from NRC's Cook model
- Heat transfer characteristic length from NRC's Cook model
- Nu multiplier & gas source heat of reaction from NRC's Cook model hs01809000 2 2 -1 hs01809001 'ic1-ice' hs01809002 20.47 1.
hs01809003 452.75 hs01809100 -1 1 0.
hs01809101 0.15 2 hs01809200 -1 hs01809201 'ice' 1 hs01809300 0 hs01809400 0 hs01809600 1 18 ICE 1.0 1.0
- to atm only hs01809601 0.985 'EQUIV BAND' 0.05 hs01809700 6200.0 0.05 14.53 hs01809800 -1 hs01809801 275.1 2 Appendix C 118
hsdg018090 01809 1 'POOL' hsdg018091 596.77 5.13e+05 277. 320. 5.0 0.05 1.
hs01909000 2 2 -1 hs01909001 'ic2-ice' hs01909002 20.47 1.
hs01909003 452.75 hs01909100 -1 1 0.
hs01909101 0.15 2 hs01909200 -1 hs01909201 'ice' 1 hs01909300 0 hs01909400 0 hs01909600 1 19 ICE 1.0 1.0
- to atm only hs01909601 0.985 'EQUIV BAND' 0.05 hs01909700 6200.0 0.05 14.53 hs01909800 -1 hs01909801 275.1 2 hsdg019090 01909 1 'POOL' hsdg019091 596.77 5.13e+05 277. 320. 5.0 0.05 1.
hs02009000 2 2 -1 hs02009001 'ic3-ice' hs02009002 20.47 1.
hs02009003 452.75 hs02009100 -1 1 0.
hs02009101 0.15 2 hs02009200 -1 hs02009201 'ice' 1 hs02009300 0 hs02009400 0 hs02009600 1 20 ICE 1.0 1.0
- to atm only hs02009601 0.985 'EQUIV BAND' 0.05 hs02009700 6200.0 0.05 14.53 hs02009800 -1 hs02009801 275.1 2 hsdg020090 02009 1 'POOL' hsdg020091 596.77 5.13e+05 277. 320. 5.0 0.05 1.
hs02109000 2 2 -1 hs02109001 'ic4-ice' hs02109002 20.47 1.
hs02109003 452.75 hs02109100 -1 1 0.
hs02109101 0.15 2 hs02109200 -1 hs02109201 'ice' 1 hs02109300 0 hs02109400 0 hs02109600 1 21 ICE 1.0 1.0
- to atm only hs02109601 0.985 'EQUIV BAND' 0.05 hs02109700 6200.0 0.05 14.53 hs02109800 -1 hs02109801 275.1 2 hsdg021090 02109 1 'POOL' hsdg021091 596.77 5.13e+05 277. 320. 5.0 0.05 1.
- End of Input Appendix C 119
- Environment heat structure added for RN deposition Ahill *
- Type = slab
- Cell number = 1
- Heat struct = 6
- Geometry = floor
- HS elev. = 0.0 m
- LHS Cell bottom = 0.0 m
- LHS Cell top = 1e10 m
- Cell height = 1e10 m
- Charact. length = 10.0 m = sqrt(100.0 m2)
HS02801000 13 1 1 HS02801001 Environment HS02801002 0.0 1.e-06 HS02801003 1.
HS02801100 -1 1.0000 HS02801102 0.0500 2 HS02801103 0.1000 3 HS02801104 0.2000 4 HS02801105 0.3000 5 HS02801106 0.4000 6 HS02801107 0.5000 7 HS02801108 1.0000 8 HS02801109 1.5000 9 HS02801110 2.0000 10 HS02801111 2.5000 11 HS02801112 3.0000 12 HS02801113 3.5870 13 HS02801200 -1 HS02801201 concrete 1 HS02801202 concrete 2 HS02801203 concrete 3 HS02801204 concrete 4 HS02801205 concrete 5 HS02801206 concrete 6 HS02801207 concrete 7 HS02801208 concrete 8 HS02801209 concrete 9 HS02801210 concrete 10 HS02801211 concrete 11 HS02801212 concrete 12 HS02801300 -1 HS02801400 0 -1 ext.5.5 HS02801600 1 28 ext.5.5 HS02801601 0.800 equiv-band 5.74 HS02801700 100.0 10.0 10.0 MELCOR FILE:
SBO.COR
- MELCOR Input *
- 26-cell test problem
- Appendix C 120
Appendix C 121 title 'STSBO_L Containment' restartf SBO_Case1.rst outputf SBO_Case1.out diagf SBO_Case1_g.dia plotf SBO_Case1.ptf messagef SBO_Case1.mes crtout cpulim 20000.0 cpuleft 30.0 restart 0 dttime 0.01 tend 23000.0
- time dtmax dtmin dtedit dtplot dtrest time1 0.0 2.0 0.001 100.0 20.0 500.0 time2 1000. 5.0 0.001 500.0 100.0 500.0 time3 10000. 5.0 0.001 500.0 30.0 1000.0 time4 32000. 5.0 0.001 500.0 200.0 5000.0
.