ML031600872
| ML031600872 | |
| Person / Time | |
|---|---|
| Site: | McGuire, Mcguire (NPF-009, NPF-017) |
| Issue date: | 06/06/2003 |
| From: | NRC/NRR/DLPM |
| To: | |
| References | |
| TAC MB6911, TAC MB6912 | |
| Download: ML031600872 (4) | |
Text
Reportability 5.1 5.0 ADMINISTRATIVE CONTROLS 5.1 Responsibility 5.1.1 5.1.2 The Station Manager shall be responsible for overall unit operation and shall delegate in writing the succession to this responsibility during his absence.
The Control Room Senior Reactor Operator (CRSRO) shall be responsible for the control room command function. During any absence of the CRSRO from the control room while the unit is in MODE 1, 2, 3, or 4, an individual [other than the Shift Technical Advisor (STA)] with an active Senior Reactor Operator (SRO) license shall be designated to assume the control room command function. During any absence of the CRSRO from the control room while the unit is in MODE 5 or 6, an individual with an active SRO license or Reactor Operator license shall be designated to assume the control room command function.
On occasion when there is a need for both the CRSRO and the relief SRO to be absent from the control room in MODE 1, 2, 3, or 4, the STA shall be allowed to assume the control room command function and serve as the SRO in the control room provided that:
- a.
the CRSRO or the relief SRO is available to return to the control room within 10 minutes,
- b.
the assumption of SRO duties by the STA is limited to periods not in excess of 15 minutes duration-and a total time not to exceed 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> during any shift, and
- c.
the STA has a SRO license on the unit.
McGuire Units 1 and 2
....~0 -
. I..
I 213 and 194 5.1 -1
A Organization 5.2 5.2 Organization 5.2.2 Unit Staff (continued)
- 2.
An individual should not be permitted to work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in any 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period, nor more than 28 hours3.240741e-4 days <br />0.00778 hours <br />4.62963e-5 weeks <br />1.0654e-5 months <br /> in any 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> period, nor more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in any 7 day period, all excluding shift turnover time;
- 3.
A break of at least 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> should be allowed between work periods, including shift turnover time;
- 4.
Except during extended shutdown periods, the use of overtime should be considered on an individual basis and not for the entire staff on a shift.
Any deviation from the above guidelines shall be authorized in advance by the Station Manager or his designee, in accordance with approved administrative procedures, or by higher levels of management, in accordance with established procedures and with documentation of the basis for granting the deviation.
Controls shall be included in the procedures such that individual overtime shall be reviewed monthly by the Station Manager or his designee to ensure that excessive hours have not been assigned.
Routine deviation from the above guidelines is not authorized.
- f.
The Operations Manager shall hold or have held an SRO license.
- g. The Shift Technical Advisor (STA) shall provide advisory technical support to the Control Room Senior Reactor Operator (CRSRO) in the areas of thermal hydraulics, reactor engineering, and plant analysis with regard to the safe operation of the unit.
(continued)
McGuire Units 1 and 2 5.2-3 213 and 194
Unit Staff Qualifications 5.3 5.0 ADMINISTRATIVE CONTROLS 5.3 Unit Staff Qualifications 5.3.1 Each member of the unit staff shall meet or exceed the minimum qualifications of ANSI-N18.1-1 971 for comparable positions, except the Radiation Protection Manager, who shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975.
McGuire Units 1 and 2 5.3-1 213 and 194
High Radiation Area 5.7 5.0 ADMINISTRATIVE CONTROLS 5.7 High Radiation Area 5.7.1 Pursuant to 10 CFR 20, paragraph 20.1601 (c), in lieu of the requirements of 10 CFR 20.1601, each high radiation area, as defined in 10 CFR 20, in which the intensity of radiation is > 100 mrem/hr but c 1000 mrem/hr at 30 cm (12 in.) from the radiation source or from any surface which the radiation penetrates, shall be barricaded and conspicuously posted as a high radiation area and entrance thereto shall be controlled by requiring issuance of a Radiation Work Permit (RWP). Individuals qualified in radiation protection procedures (e.g., Radiation Protection Technicians) or personnel continuously escorted by such individuals may be exempt from the RWP issuance requirement during the performance of their assigned duties in high radiation areas with exposure rates
< 1000 mrem/hr, provided they are otherwise following plant radiation protection procedures for entry into such high radiation areas.
Any individual or group of individuals permitted to enter such areas shall be provided with or accompanied by one or more of the following:
- a.
A radiation monitoring device that continuously indicates the radiation dose rate in the area.
- b.
A radiation monitoring device that continuously integrates the radiation dose rate in the area and alarms when a preset integrated dose is received. Entry into such areas with this monitoring device may be made after the dose rate levels in the area have been established and personnel are aware of them.
- c.
An individual qualified in radiation protection procedures with a radiation dose rate monitoring device, who is responsible for providing positive control over the activities within the area and shall perform periodic radiation surveillance at the frequency specified by the Radiation Protection Manager in the RWP.
5.7.2 In addition to the requirements of Specification 5.7.1, areas with radiation levels
> 1000 mrem/hr at 30 cm (12 in.) from the radiation source or from any surface which the radiation penetrates shall be provided with locked or continuously guarded doors to prevent unauthorized entry and the keys shall be maintained under the administrative control of the Operations Shift Manager, Radiation Protection Manager, or his or her designee. Doors shall remain locked except during periods of access by personnel under an approved RWP that shall specify the dose rate levels in the immediate work areas and the maximum allowable stay times for individuals in those areas. In lieu of the stay time specification of the RWP, direct or remote (such as closed circuit TV cameras) continuous surveillance may be made by personnel qualified in radiation protection procedures to provide positive exposure control over the activities being performed within the area.
(continued)
McGuire Units 1 and 2 5.7-1 213 and 194