INDEX ADMINISTRATIVE CONTROLS SECTION PAGE 6.9 REPORTING REQUIREMENTS 6.9.1 ROUTINE REPORTS 6-16 STARTUP REPORTS 6-16 ANNUAL REPORTS.....................
6-17 ANNUAL RADIOLOGICAL REPORTS.................
6-18 MONTHLY OPERATING REPORT 6-18 CORE OPERATING LIMITS REPORT 6-18 6.9.2 SPECIAL REPORTS 6-19 6.10 DELETED 6.11 RADIATION PROTECTION PROGRAM 6-20 6.12 HIGH RADIATION AREA 6-20 6.13 SYSTEMS INTEGRITY........................
6-23 6.14 IODINE MONITORING........................
6-23 6.15 RADIOLOGICAL EFFLUENT MONITORING AND OFFSITE DOSE CALCULATION MANUAL (REMODCM) 6-24 6.16 RADIOACTIVE WASTE TREATMENT 6-24 6.17 SECONDARY WATER CHEMISTRY 6-25 6.18 DELETED 6.19 CONTAINMENT LEAKAGE RATE TESTING PROGRAM 6-26 6.20 RADIOACTIVE EFFLUENT CONTROLS PROGRAM..............
6-26 6.21 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM..........
6-28 6.22 REACTOR COOLANT PUMP FLYWHEEL INSPECTION PROGRAM 6-28 6.23 TECHNICAL SPECIFICATION (TS) BASES CONTROL PROGRAM 6-28 MILLSTONE - UNIT 2 XVII Amendment No. 7, 7,
, M, 1, 0832
- log, III, 90 7, 276
ADMINISTRATIVE CONTROLS ANNUAL REPORTS1 6.9.1.4 Annual reports covering the activities of the unit as described below for the previous calendar year shall be submitted in accordance with 10 CFR 50.4.
6.9.1.5a. OCCUPATIONAL RADIATION EXPOSURE REPORT
NOTE--------------------------------------
A single submittal may be made for a multiple unit station.
The submittal should combine sections common to all units at the station.
A tabulation, on an annual basis of the number of station, utility, and other personnel (including contractors), for whom monitoring was performed, receiving an annual deep dose equivalent > 100 mrems and the associated collective deep dose equivalent (reported in person-rem) according to work and job functions (e.g., reactor operations and surveillance, inservice inspection, routine maintenance, special maintenance (describe maintenance), waste processing and refueling).
This tabulation supplements the requirements of 10 CFR 20.2206.
The dose assignments to various duty functions may be estimated based on pocket ionization chamber, thermoluminescence dosimeter (TLD),
electronic dosimeter, or film badge measurements.
Small exposures totaling < 20 percent of the individual total dose need not be accounted for.
In the aggregate, at least 80 percent of the total deep dose equivalent received from external sources should be assigned to specific major work functions.
The report covering the previous calendar year shall be submitted by April 30 each year.
- 6. 9. 1.
5b.
- 6. 9.
1.5c.
The complete results of steam generator tube inservice inspections performed during the report period (reference Specification 4.4.5.1.5.b). The report covering the previous calendar year shall be submitted prior to March 1 of each year.
The results of specific activity analysis in which the primary coolant exceeded the limits of Specification 3.4.8. The following information shall be included:
(1) Reactor power history starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the first sample in which the limit was exceeded; (2) Results of the last isotopic analysis for radioiodine performed prior to exceeding the limit, results of analysis while the limit was exceeded and results of one analysis after the radioiodine activity was reduced to less than the limit.
Each result should include date and time of sampling and the radioiodine concentrations; (3) Clean-up system flow history starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the first sample in which the limit was exceeded; (4) Graph of the I-131 concentration and one other radioiodine isotope concentration in microcuries per gram as a function of time for the duration of the specific activity above the steady-state level; and (5) The time duration when the specific activity of the primary coolant exceeded the radioiodine limit. The report covering the previous calendar year shall be submitted prior to March 1 of each year.
1 A single submittal may be made for a multiple unit station.
The submittal should combine those sections that are common to all units at the station.
MILLSTONE - UNIT 2 0815 6-17 Amendment No. 7f,
- J7Z, 779,276 7Jg, J97,
ADMINISTRATIVE CONTROLS 6.9.1.5d. Documentation of all failures (inability to lift or reclose within the tolerances allowed by the design basis) and challenges to the pressurizer PORVs or safety valves.
The report covering the previous calendar year shall be submitted prior to March 1 of each year.
ANNUAL RADIOLOGICAL REPORTS 6.9.1.6a ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT A single submittal may be made for a multiple unit station.
The submittal shall combine sections common to all units at the station.
The Annual Radiological Environmental Operating Report covering the operation of the unit during the previous calendar year shall be submitted by May 1 of each year. The report shall include summaries, interpretations, and analyses of trends of the results of the Radiological Environmental Monitoring Program for the reporting period.
The material provided shall be consistent with the objectives outlined in the Radiological Effluent Monitoring and Offsite Dose Calculation Manual (REMODCM), and in 10 CFR Part 50, Appendix I, Sections IV.B.2, IV.B.3, and IV.C.
The Annual Radiological Environmental Operating Report shall include the results of analyses of all radiological environmental samples and of all environmental radiation measurements taken during the period pursuant to the locations specified in the table and figures in the REMODCM, as well as summarized and tabulated results of these analyses and measurements. In the event that some individual results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results.
The missing data shall be submitted in the next annual report.
6.9.1.6b RADIOACTIVE EFFLUENT RELEASE REPORT
NOTE----------------------------------------
A single submittal may be made for a multiple unit station.
The submittal shall combine sections common to all units at the station; however, for units with separate radwaste systems, the submittal shall specify the releases of radioactive material from each unit.
The Radioactive Effluent Release Report covering the operation of the unit in the previous year shall be submitted prior-to May 1 of each year in accordance-with 10 CFR 50.36a.
The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit. The material provided shall be consistent with the objectives outlined in the REMODCM and in conformance with 10 CFR 50.36a and 10 CFR Part 50, Appendix I, Section IV.B.I.
MONTHLY OPERATING REPORT 6.9.1.7 Routine reports of operating statistics and shutdown experience shall be submitted on a monthly basis to the U.S.
Nuclear Regulatory Commission, Document Control Desk, Washington, D.C. 20555, one copy to the Regional MILLSTONE - UNIT 2 6-18 Amendment No. Xf, 7, log, }D;,
0815 M,
- 7i7, J70, pg,
, j, I
ADMINISTRATIVE CONTROLS SPECIAL REPORTS (CONT.)
- b. Deleted
- c. Deleted
- d.
ECCS Actuation, Specifications 3.5.2 and 3.5.3.
- e.
Deleted
- f. Deleted
- g.
RCS Overpressure Mitigation, Specification 3.4.9.3.
- h. Deleted
- i.
Degradation of containment structure, Specification 4.6.1.6.4.
- j.
Steam Generator Tube Inspection, Specification 4.4.5.1.5.
- k. Accident Monitoring Instrumentation, Specification 3.3.3.8.
- 1. Radiation Monitoring Instrumentation, Specification 3.3.3.1.
- m.
Deleted 6.10 Deleted 6.11 RADIATION PROTECTION PROGRAM Procedures for personnel radiation protection shall be prepared consistent with the requirements of 10 CFR Part 20 and shall be approved, maintained and adhered to for all operations involving personnel radiation exposure.
6.12 HIGH RADIATION AREA As provided in paragraph 20.1601(c) of 10 CFR Part 20, the following controls shall be applied to high radiation areas in place of the controls required by paragraph 20.1601(a) and (b) of 10 CFR Part 20:
6.12.1 High Radiation Areas with Dose Rates Not Exceeding 1.0 rem/hour at 30 Centimeters from the Radiation Source or from any Surface Penetrated by the Radiation
- a.
Each entryway to such an area shall be barricaded and conspicuously posted as a high radiation area.
Such barricades may be opened as necessary to permit entry or exit of personnel or equipment.
- b. Access to, and activities in, each such area shall be controlled by means of a Radiation Work Permit (RWP) or equivalent that includes specification of radiation dose rates in the immediate work area(s) and other appropriate radiation protection equipment and measures.
MILLSTONE - UNIT 2 6-20 Amendment No. i, }, 7qj,
}X7, 0816
}ii, 79g, 77I, f,
7^, 7i7, Z}i 70 M00, 77276
ADMINISTRATIVE CONTROLS 6.12 HIGH RADIATION AREA (CONT.)
- c.
Individuals qualified in radiation protection procedures and personnel continuously escorted by such individuals may be exempted from the requirement for an RWP or equivalent while performing their assigned duties provided that they are otherwise following plant radiation protection procedures from entry to, exit from, and work in such areas.
- d.
Each individual or group entering such an area shall possess:
- 1. A radiation monitoring device that continuously displays radiation dose rates in the area, or
- 2. A radiation monitoring device that continuously integrates the radiation dose rates in the area and alarms when the device's dose alarm setpoint is reached, with an appropriate alarm setpoint, or
- 3. A radiation monitoring device that continuously transmits dose rate and cumulative dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area, or
- 4. A self-reading dosimeter (e.g., pocket ionization chamber or electronic dosimeter) and, (i) Be under the surveillance, as specified in the RWP or equivalent, while in the area, of an individual qualified in radiation protection procedures, equipped with a radiation monitoring device that continuously displays radiation dose rates in the area; who is responsible for controlling personnel exposure within the area, or (ii) Be under the surveillance as specified in the RWP or equivalent, while in the area, by means of closed circuit television, of personnel qualified in radiation protection procedures, responsible for controlling personnel radiation exposure in the area, and with the means to communicate with individuals in the area who are covered by such surveillance.
- e.
Except for individuals qualified in radiation protection procedures, or personnel continuously escorted by such individuals, entry into such areas shall be made only after dose rates in the area have been determined and entry personnel are knowledgeable of them.
These continuously escorted personnel will receive a pre-job briefing prior to entry into such areas.
This dose rate determination, knowledge, and pre-job briefing does not require documentation prior to initial entry.
MILLSTONE - UNIT 2 6-21 Amendment No. i, 7, 70g, fl;, 799, 0816 7f,
, Z0276
ADMINISTRATIVE CONTROLS 6.12 HIGH RADIATION AREA (CONT.)
6.12.2 High Radiation Areas with Dose Rates Greater than 1.0 rem/hour at 30 Centimeters from the Radiation Source or from any Surface Penetrated by the Radiation, but less than 500 rads/hour at 1 Meter from the Radiation Source or from any Surface Penetrated by the Radiation
- a.
Each entryway to such an area shall be conspicuously posted as a high radiation area and shall be provided with a locked or continuously guarded door or gate that prevents unauthorized entry, and, in addition:
- 1. All such door and gate keys shall be maintained under the administrative control of the shift manager, radiation protection manager, or his or her designees, and
- 2. Doors and gates shall remain locked except during periods of personnel or equipment entry or exit.
- b.
Access to, and activities in, each such area shall be controlled by means of an RWP or equivalent that includes specification of radiation dose rates in the immediate work area(s) and other appropriate radiation protection equipment and measures.
- c.
Individuals qualified in radiation protection procedures may be exempted from the requirement for an RWP or equivalent while performing radiation surveys in such areas provided that they are otherwise following plant radiation protection procedures for entry to, exit from, and work in such areas.
- d.
Each individual group entering such an area shall possess:
- 1. A radiation monitoring device that continuously integrates the radiation dose rates in the area and alarms when the device's dose alarm setpoint is reached, with an appropriate alarm setpoint, or
- 2. A radiation monitoring device that continuously transmits dose rate and cumulative dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area with the means to communicate with and control every individual in the area, or
- 3. A self-reading dosimeter (e.g., pocket ionization chamber or electronic dosimeter) and, (i) Be under the surveillance, as specified in the RWP or equivalent, while in the area, of an individual qualified in radiation protection procedures, equipped with a radiation monitoring device that continuously displays radiation dose rates in the area; who is responsible for controlling personnel exposure within the area, or MILLSTONE - UNIT 2 6-22 Amendment No. i, /, Z J;7, J%g, 0816 If 1, g7276
ADMINISTRATIVE CONTROLS 6.12 HIGH RADIATION AREA (CONT.)
(ii) Be under the surveillance as specified in the RWP or equivalent, while in the area, by means of closed circuit television, of personnel qualified in radiation protection procedures, responsible for controlling personnel radiation exposure in the area, and with the means to communicate with and control every individual in the area.
- 4.
In those cases where options (2) and (3), above, are impractical or determined to be inconsistent with the "As Low As is Reasonably Achievable" principle, a radiation monitoring device that continuously displays radiation dose rates in the area.
- e.
Except for individuals qualified in radiation protection procedures, or personnel continuously escorted by such individuals, entry into such areas shall be made only after dose rates in the area have been determined and entry personnel are knowledgeable of them.
These continuously escorted personnel will receive a pre-job briefing prior to entry into such areas. This dose rate determination, knowledge, and pre-job briefing does not require documentation prior to initial entry.
- f.
Such individual areas that are within a larger area where no enclosure exists for the purpose of locking and where no enclosure can reasonably be constructed around the individual area need not be controlled by a locked door or gate, nor continuously guarded, but shall be barricaded, conspicuously posted, and a clearly visible flashing light shall be activated at the area as a warning device.
6.13 SYSTEMS INTEGRITY The licensee shall implement a program to reduce leakage from systems outside containment that would, or could, contain highly radioactive fluids during a serious transient, or accident, to as low as practical levels.
This program shall include the following:
- 1. Provisions establishing preventive maintenance and periodic visual inspection requirements, and
- 2. Integrated leak test requirements for each system at a frequency not to exceed refueling cycle intervals.
6.14 IODINE MONITORING The licensee shall implement a program which will ensure the capability to accurately determine the airborne iodine concentration in vital areas under accident conditions.
This program shall include the following:
- 1. Training of personnel,
- 2. Procedures for monitoring, and
- 3. Provisions for maintenance of sampling and analysis equipment.
MILLSTONE - UNIT 2 6-23 Amendment No.
, 707, 70 0816 Order 10/24/80 777, 799, 7M, 70,276
ADMINISTRATIVE CONTROLS 6.19 CONTAINMENT LEAKAGE RATE TESTING PROGRAM A program shall be established to implement the leakage rate testing of the primary containment as required by 10CFR50.54(o) and IOCFR50, Appendix J, Option B as modified by approved exemptions.
This program shall be in accordance with the guidelines contained in Regulatory.Guide 1.163, "Performance-Based Containment Leak-Test Program," dated September 1995.
The peak calculated primary Containment internal pressure for the design basis loss of coolant accident is Pa*
The maximum allowable primary containment leakage rate, L at P is 0.5% of primary containment air weight per day.
Leakage rate acceptance criteria are:
- a.
Primary containment overall leakage rate acceptance criterion is < 1.0 La.
During the first unit startup following testing in accordance with this program, the leakage rate acceptance criteria are < 0.60 La for the combined Type B and Type C tests, and < 0.75 La for Type A tests;
- b. Air lock testing acceptance criteria are:
- 1. Overall air lock leakage rate is < 0.05 La when tested at > P.
- 2. For each door, pressure decay is < 0.1 psig when pressurized to > 25 psig for at least 15 minutes.
The provisions of SR 4.0.2 do not apply for test frequencies specified in the Primary Containment Leakage Rate Testing Program.
The provisions of SR 4.0.3 are applicable to the Primary Containment Leakage Rate Testing Program.
6.20 RADIOACTIVE EFFLUENT CONTROLS PROGRAM This program conforms to 10 CFR 50.36a for the control of radioactive effluents and for maintaining the doses to members of the public from radioactive effluents as low as reasonably achievable.
The program shall be contained in the REMODCM, shall be implemented by procedures, and shall include remedial actions to be taken whenever the program limits are exceeded.
The program shall include the following elements:
- a. Limitations on the functional capability of radioactive liquid and gaseous monitoring instrumentation including surveillance tests and setpoint determination in accordance with the methodology in the REMODCM;
- b. Limitations on the concentrations of radioactive material released in liquid effluents to unrestricted areas, conforming to ten times the concentration values in Appendix B, Table 2, Column 2 to 10 CFR 20.1001-20.2402; Amendment No.
- p7X,
?pp, 276 MILLSTONE -
UNIT 2 0817 6 -26
ADMINISTRATIVE CONTROLS 6.20 RADIOACTIVE EFFLUENT CONTROLS PROGRAM (CONT.)
- c. Monitoring, sampling, and analysis of radioactive liquid and gaseous effluents in accordance with 10 CFR 20.1302 and with the methodology and parameters in the REMODCM;
- d. Limitations on the annual and quarterly doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas, conforming to 10 CFR 50, Appendix I;
- e. Determination of cumulative dose contributions from radioactive effluents for the current calendar quarter and current calendar year in accordance with the methodology and parameters in the REMODCM at least every 31 days.
Determination of projected dose contributions from radioactive effluents in accordance with the methodology in the REMODCM at least every 31 days;
- f.
Limitations on the functional capability and use of the liquid and gaseous effluent treatment systems to ensure that appropriate portions of these systems are used to reduce releases of radioactivity when the projected doses in a period of 31 days would exceed 2% of the guidelines for the annual dose or dose commitment, conforming to 10 CFR 50, Appendix I;
- g. Limitations on the dose rate resulting from radioactive material released in gaseous effluents from the site to areas at or beyond the site boundary shall be in accordance with the following:
- 1. For noble gases: a dose rate < 500 mrem/yr to the whole body and a dose rate < 3000 mrem/yr to the skin, and
- 2.
For iodine-131, iodine-133,
- tritium, and all radionuclides in particulate form with half-lives greater than 8 days: a dose rate
< 1500 mrem/yr to any organ;
- h. Limitations on the annual and quarterly air doses resulting from noble gases released in gaseous effluents from each unit to areas beyond the site boundary, conforming to 10 CFR 50, Appendix I;
- i. Limitations on the annual and quarterly doses to a member of the public from iodine-131, iodine-133, tritium, and all radionuclides in particulate form with half lives > 8 days in gaseous effluents released from each unit to areas beyond the site boundary, conforming to 10 CFR 50, Appendix I; and
- j.
Limitations on the annual dose or dose commitment to any member of the public, beyond the site boundary, due to releases of radioactivity and to radiation from uranium fuel cycle sources, conforming to 40 CFR 190.
The provisions of Specification 4.0.2 and Specification 4.0.3 are applicable to the Radioactive Effluent Controls Program surveillance frequency.
Amendment No. 7i0, 276 MILLSTONE - UNIT 2 0817 6-27
ADMINISTRATIVE CONTROLS 6.21 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM A program shall be provided to monitor the radiation and radionuclides in the environs of the plant.
The program shall provided (1) representative measurements of radioactivity in the highest potential exposure pathways, and (2) verification of the accuracy of the effluent monitoring program and modeling of environmental exposure pathways.
The program shall (1) be contained in the REMODCM, (2) conform to that guidance of Appendix I to 10 CFR Part 50, and (3) include the following:
- a. Monitoring,
- sampling, analysis, and reporting of radiation and radionuclides in the environment in accordance with the methodology and parameters in the REMODCM.
- b. A Land Use Census to ensure that changes in the use of areas at and beyond the SITE BOUNDARY are identified and that modifications to the monitoring program are made if required by the results of this census, and
- c. Participation in a Interlaboratory Comparison Program to ensure that independent checks on the precision and accuracy of the measurements of radioactive materials in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring.
6.22 REACTOR COOLANT PUMP FLYWHEEL INSPECTION PROGRAM This program shall provide for the inspection of each reactor coolant pump flywheel by either qualified in-place UT examination over the volume from the inner bore of the flywheel to the circle of one-half the outer radius, or a surface examination (magnetic particle testing and/or penetrant testing) of exposed surfaces defined by the volume of the disassembled flywheels at least once every 10 years.
6.23 TECHNICAL SPECIFICATIONS (TS) BASES CONTROL PROGRAM This program provides a means for processing changes to the Bases of these Technical Specifications.
- a. Changes to the Bases of the TS shall be made under appropriate administrative controls and reviews.
- b. Licensees may make changes to Bases without prior NRC approval provided the changes do not require either of the following:
- 1. A change in the TS incorporated in the license or
- 2. A change in the updated FSAR or Bases that requires NRC approval pursuant to 10 CFR 50.59.
- c. The Bases Control Program shall contain provisions to ensure that the Bases are maintained consistent with the FSAR.
- d. Proposed changes that meet the criteria of Specification 6.23.b above shall be reviewed and approved by the NRC prior to implementation.
Changes to the Bases implemented without prior NRC approval shall be provided to the NRC on a frequency consistent with 10 CFR 50.71(e).
Amendment No. gp, ?P, g7, 276 MILLSTONE - UNIT 2 0817 6-28
INDEX ADMINISTRATIVE CONTROLS SECTION 6.8 PROCEDURES AND PROGRAMS 6.9 REPORTING REQUIREMENTS...............
6.9.1 ROUTINE REPORTS.
Startup Report Annual Reports Occupational Radiation Exposure Report Annual Radiological Environmental Operating Report Annual Radioactive Effluent Release Report Monthly Operating Reports.............
Core Operating Limits Report 6.9.2 SPECIAL REPORTS 6.10
..... 6-17
...... 6-17
...... 6-17
...... 6-18
...... 6-18
...... 6-19
...... 6-19
...... 6-19 6-19a
...... 6-21 DELETED 6.11 RADIATION PROTECTION PROGRAM...........
1 6.12 HIGH RADIATION AREA................
6.13 RADIOLOGICAL EFFLUENT MONITORING AND OFFSITE DOSE CALCULATION MANUAL (REMODCM) 6.14 RADIOACTIVE WASTE TREATMENT............
6.15 RADIOACTIVE EFFLUENT CONTROLS PROGRAM.......
6.16 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM...
6.17 REACTOR COOLANT PUMP FLYWHEEL INSPECTION PROGRAM 6.18 TECHNICAL SPECIFICATIONS (TS) BASES CONTROL PROGRAM 6.19 COMPONENT CYCLIC OR TRANSIENT LIMIT........
MILLSTONE -
UNIT 3 0914 xix Amendment No.
70,,
- 777, 799, ?P9, 7
215 PAGE
. 6-14
AnMTNT.CTRATTVF rQNTRl S Startup Reports shall be submitted within: (1) 90 days following completion of the Startup Test Program, (2) 90 days following resumption or commencement of commercial power operation, or (3) 9 months following initial criticality, whichever is earliest.
If the Startup Report does not cover all three events (i.e., initial criticality, completion of Startup Test Program, and resumption or commencement of commercial operation), supplementary reports shall be submitted at least every 3 months until all three events have been completed.
ANNUAL REPORTS*
6.9.1.2 Annual Reports covering the activities of the unit as described below for the previous calendar year shall be submitted in accordance with 10 CFR 50.4.
6.9.1.2a. OCCUPATIONAL RADIATION EXPOSURE REPORT NOTE---------------------------------------
A single submittal may be made for a multiple unit station. The submittal should combine sections common to all units at the station.
A tabulation on an annual basis of the number of station, utility, and other personnel (including contractors), for whom monitoring was performed, receiving an annual deep dose equivalent > 100 mrems and the associated collective deep dose equivalent (reported in person -
rem) according to work and job functions (e.g., reactor operations and surveillance, inservice inspection, routine maintenance, special maintenance (describe maintenance),
waste processing, and refueling). This tabulation supplements the requirements of 10 CFR 20.2206.
The dose assignments to various duty functions may be estimated based on pocket ionization chamber, thermoluminescence dosimeter (TLD), electronic dosimeter, or film badge measurements.
Small exposures totalling < 20 percent of the individual total dose need not be accounted for. In the aggregate, at least 80 percent of the total deep dose equivalent received from external sources should be assigned to specific major work functions. The report covering the previous calendar year shall be submitted by April 30 of each year.
- 6.
9.1.2b.
The results of specific activity analyses in which the reactor coolant exceeded the limits of Specification 3.4.8.
The following information shall be included: (1) Reactor power history starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the first sample in which the limit was exceeded (in graphic and tabular format); (2) Results of the last isotopic analysis for radioiodine performed prior to exceeding the limit, results of analysis while the limit was exceeded and results of one analysis after the radioiodine activity was reduced to less than limit. Each result should include date and time of sampling and the radioiodine concentrations; (3) Clean-up flow history starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the first sample in which the limit was exceeded; (4) Graph of the 1-131 concentration (Ci/gm) and one other radio-iodine isotope concentration (Ci/gm) as a function of time for the A single submittal may be made for a multiple unit station.
The submittal should combine those sections that are common to all units at the station.
Amendment No. 99, 215 MILLSTONE - UNIT 3 0910 I
6-18
ADMINISTRATIVE CONTROLS ANNUAL REPORTS (Continued) duration of the specific activity above the steady-state level; and (5) The time duration when the specific activity of the reactor coolant exceeded the radioiodine limit.
The report covering the previous calendar year shall be submitted prior to March 1 of each year.
6.9.1.2c.
Documentation of all challenges to the pressurizer power-operated relief valves (PORVs) and safety valves. The report covering the previous calendar year shall be submitted prior to March 1 of each year.
6.9.1.3 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT
NOTE--------------------------------------
A single submittal may be made for a multiple unit station.
The submittal shall combine sections common to all units at the station.
The Annual Radiological Environmental Operating Report covering the operation of the unit during the previous calendar year shall be submitted by May 1 of each year.
The report shall include summaries, interpretations, and analyses of trends of the results of the Radiological Environmental Monitoring Program for the reporting period.
The material provided shall be consistent with the objectives outlined in the Radiological Effluent Monitoring and Offsite Dose Calculation Manual (REMODCM), and in 10 CFR Part 50, Appendix I, Sections IV.B.2, IV.B.3, and IV.C.
The Annual Radiological Environmental Operating Report shall include the results of analyses of all radiological environmental samples and of all environmental radiation measurements taken during the period pursuant to the locations specified in the table and figures in the REMODCM, as well as summarized and tabulated results of these analyses and measurements.
In the event that some individual results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results.
The missing data shall be submitted in the next annual report.
6.9.1.4 RADIOACTIVE EFFLUENT RELEASE REPORT
NOTE----------------------------------------
A single submittal may be made for a multiple unit station.
The submittal shall combine sections common to all units at the station; however, for units with separate radwaste systems, the submittal shall specify the releases of radioactive material from each unit.
The Radioactive Effluent Release Report covering the operation of the unit in the previous year shall be submitted prior to May I of each year in accordance with 10 CFR 50.36a.
The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit.
The material provided shall be consistent with the objectives outlined in the REMODCM and in conformance with 10 CFR 50.36a and 10 CFR Part 50, Appendix I, Section IV.B.1.
MILLSTONE -
UNIT 3 6-19 Amendment No. 7g, 77, ii, 99, 0910 I??, 215
ADMINISTRATIVE CONTROLS 6.9.1.6.c The core ble limits (e.g.
limits, ECCS limits accident analysis 1 operating limits shall be determined so fuel thermal-mechanical
- limits, core
, nuclear limits such as shutdown margin, imits) of the safety analysis are met.
that all applica-thermal-hydraulic and transient and 6.9.1.6.d The CORE OPERATING LIMITS REPORT, or supplements thereto, shall be provided cycle, to the NRC Document Control Desk with trator and Resident Inspector.
including any mid-cycle revisions upon issuance, for each reload copies to the Regional Adminis-SPECIAL REPORTS 6.9.2 Special reports shall be submitted to the Commission, Document Control Desk, Washington, D.C.
Regional Administrator Region I, and one copy to the within the time period specified for each report.
U.S. Nuclear Regulatory 20555, one copy to the NRC Resident Inspector, 6.10 Deleted.
6.11 RADIATION PROTECTION PROGRAM
- 6. 11.1 Procedures for personnel radiation protection consistent with the requirements of 10 CFR Part 20 and maintained, and adhered to for all operations involving exposure.
shall be shall be personnel prepared
.approved, radiation 6.12 HIGH RADIATION AREA As provided in paragraph 20.1601(c) of 10 CFR Part 20, the following controls shall be applied to high radiation areas in place of the controls required by paragraph 20.1601(a) and (b) of 10 CFR Part 20:
6.12.1 High Radiation Areas with Dose Rates Not Exceeding 1.0 rem/hour at 30 Centimeters from the Radiation Source or from any Surface Penetrated by the Radiation
- a. Each entryway to such an area shall be barricaded and conspicuously posted as a high radiation area.
Such barricades may be opened as necessary to permit entry or exit of personnel or equipment.
- b. Access to, and activities in, each such area shall be controlled by means of a Radiation Work Permit (RWP) or equivalent that includes specification of radiation dose rates in the immediate work area(s) and other appropriate radiation protection equipment and measures.
- c. Individuals qualified in radiation protection procedures and personnel continuously escorted by such individuals may be exempted from the requirement for an RWP or equivalent while performing their assigned duties provided that they are otherwise following plant radiation protection procedures for entry to, exit from, and work in such areas.
- d. Each individual or group entering such an area shall possess:
- 1.
A radiation monitoring device that continuously displays radiation dose rates in the area, or MILLSTONE -
UNIT 3 0911 6-21 Amendment No. 7g, go, p0, 0y, 70M, 777, 777, 215
ADMINISTRATIVE CONTROLS 6.12 HIGH RADIATION AREA (cont.)
- 2.
A radiation monitoring device that continuously integrates the radiation dose rates in the area and alarms when the device's dose alarm setpoint is reached, with an appropriate alarm setpoint, or
- 3.
A radiation monitoring device that continuously transmits dose rate and cumulative dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area, or
- 4.
A self-reading dosimeter (e.g., pocket ionization chamber or electronic dosimeter) and, (i) Be under the surveillance, as specified in the RWP or equivalent, while in the area, of an individual qualified in radiation protection procedures, equipped with a radiation monitoring device that continuously displays radiation dose rates in the area; who is responsible for controlling personnel exposure within the area, or (ii) Be under the surveillance as specified in the RWP or equivalent, while in the area, by means of closed circuit television, of personnel qualified in radiation protection procedures, responsible for controlling personnel radiation exposure in the area, and with the means to communicate with individuals in the area who are covered by such surveillance.
- e.
Except for individuals qualified in radiation protection procedures, or personnel continuously escorted by such individuals, entry into such areas shall be made only after dose rates in the area have been determined and entry personnel are knowledgeable of them. These continuously escorted personnel will receive a pre-job briefing prior to entry into such areas. This dose rate determination, knowledge, and pre-job briefing does not require documentation prior to initial entry.
6.12.2 High Radiation Areas with Dose Rates Greater than 1.0 rem/hour at 30 Centimeters from the Radiation Source or from any Surface Penetrated by the Radiation, but less than 500 rads/hour at 1 Meter from the Radiation Source or from any Surface Penetrated by the Radiation
- a.
Each entryway to such an area shall be conspicuously posted as a high radiation area and shall be provided with a locked or continuously guarded door or gate that prevents unauthorized entry, and, in addition:
- 1.
All such door and gate keys shall be maintained under the administrative control of the shift manager, radiation protection manager, or his or her designees, and
- 2.
Doors and gates shall remain locked except during periods of personnel or equipment entry or exit.
- b. Access to, and activities in, each such area shall be controlled by means of an RWP or equivalent that includes specification of MILLSTONE - UNIT 3 6-22 Amendment No.
2, 5 215 0911
ADMINISTRATIVE CONTROLS 6.12 HIGH RADIATION AREA (cont.)
radiation dose rates in the immediate work area(s) and other appropriate radiation protection equipment and measures.
- c. Individuals qualified in radiation protection procedures may be exempted from the requirement for an RWP or equivalent while performing radiation surveys in such areas provided that they are otherwise following plant radiation protection procedures for entry to, exit from, and work in such areas.
- d. Each individual group entering such an area shall possess:
- 1. A radiation monitoring device that continuously integrates the radiation dose rates in the area and alarms when the device's dose alarm setpoint is reached, with an appropriate alarm setpoint, or
- 2. A radiation monitoring device that continuously transmits dose rate and cumulative dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area with the means to communicate with and control every individual in the area, or
- 3. A self-reading dosimeter (e.g., pocket ionization chamber or electronic dosimeter) and, (i) Be under the surveillance, as specified in the RWP or equivalent, while in the area, of an individual qualified in radiation protection procedures, equipped with a radiation monitoring device that continuously displays radiation dose rates in the area; who is responsible for controlling personnel exposure within the area, or (ii) Be under the surveillance as specified in the RWP or equivalent, while in the area, by means of closed circuit television, of personnel qualified in radiation protection procedures, responsible for controlling personnel radiation exposure in the area, and with the means to communicate with and control every individual in the area.
- 4.
In those cases where options (2) and (3), above, are impractical or determined to be inconsistent with the "As Low As is Reasonably Achievable" principle, a radiation monitoring device that continuously displays radiation dose rates in the area.
- e. Except for individuals qualified in radiation protection procedures, or personnel continuously escorted by such individuals, entry into such areas shall be made only after dose rates in the area have been determined and entry personnel are knowledgeable of them.
These continuously escorted personnel will receive a pre-job briefing prior to entry into such areas.
This dose rate determination, knowledge, and pre-job briefing does not require documentation prior to initial entry.
- f. Such individual areas that are within a larger area where no enclosure exists for the purpose of locking and where no enclosure can reasonably be constructed around the individual area need not be controlled by a locked door or gate, nor continuously guarded, but shall be barricaded, conspicuously posted, and a clearly visible flashing light shall be activated at the area as a warning device.
Amendment No. 0R, Z77, 215 MILLSTONE - UNIT 3 0911 6 -23
ADMTNTSTRATTVF CNTROlPS 6.15 RADIOACTIVE EFFLUENT CONTROLS PROGRAM This program conforms to 10 CFR 50.36a for the control of radioactive effluents and for maintaining the doses to members of the public from radioactive effluents as low as reasonably achievable.
The program shall be contained in the REMODCM, shall be implemented by procedures, and shall include remedial actions to be taken whenever the program limits are exceeded.
The program shall include the following elements:
- a. Limitations on the functiona monitoring instrumentation determination in accordance
- b. Limitations on the concent liquid effluents to unrest concentration values in App(
20.2402; 1 capability of radioactive liquid and gaseous including surveillance tests and setpoint with the methodology in the REMODCM; rations of radioactive material released in ricted areas, conforming to ten times the endix B, Table 2, Column 2 to 10 CFR 20.1001-
- c. Monitoring, sampling, and analysis of radioactive liquid and gaseous effluents in accordance with 10 CFR 20.1302 and with the methodology and parameters in the REMODCM; d
Limitations on the annual member of the public from released from each unit to Appendix I; and quarterly doses or dose commitment to a radioactive materials in liquid effluents unrestricted areas, conforming to 10 CFR 50,
- e. Determination of cumulative dose contributions from radioactive effluents for the current calendar quarter and current calendar year in accordance with the methodology and parameters in the REMODCM at least every 31 days.
Determination of projected dose contributions from radioactive effluents in accordance with the methodology in the REMODCM at least every 31 days;
- f. Limitations on the functional capability and use of the liquid and gaseous effluent treatment systems to ensure that appropriate portions of these systems are used to reduce releases of radioactivity when the projected doses in a period of 31 days would exceed 2% of the guidelines for the annual dose or dose commitment, conforming to 10 CFR 50, Appendix I;
- g. Limitations on the dose rate resulting from radioactive material released in gaseous effluents from the site to areas at or beyond the site boundary shall be in accordance with the following:
- 1. For noble gases: a dose rate < 500 mrem/yr to the whole body and a dose rate < 3000 mrem/yr to the skin, and
- 2. For iodine-131, iodine-133,
- tritium, and all particulate form with half-lives greater than 8 1500 mrem/yr to any organ; radionuclides in days: a dose rate <
- h. Limitations on the annual and quarterly air doses resulting from released in gaseous effluents from each unit to areas site boundary, conforming to 10 CFR 50, Appendix I; noble gases beyond the
- i. Limitations on the annual and quarterly doses to a member of the public from iodine-131, iodine-133, tritium, and all radionuclides in particulate form with half lives > 8 days in gaseous effluents released from each unit to areas beyond the site boundary, conforming to 10 CFR 50, Appendix I; and Amendment No. Jgg, 215 MILLSTONE - UNIT 3 0915 I
6-25
ADMINISTRATIVE CONTROLS
- j.
Limitations on the annual dose or dose commitment to any member of the public, beyond the site boundary, due to releases of radioactivity and to radiation from uranium fuel cycle sources, conforming to 40 CFR 190.
The provisions of Specification 4.0.2 and Specification 4.0.3 are applicable to the Radioactive Effluent Controls Program surveillance frequency.
6.16 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM A program shall be provided to monitor the radiation and radionuclides in the environs of the plant.
The program shall provided (1) representative measurements of radioactivity in the highest potential exposure pathways, and (2) verification of the accuracy of the effluent monitoring program and modeling of environmental exposure pathways.
The program shall (1) be contained in the REMODCM, (2) conform to the guidance of Appendix I to 10 CFR Part 50, and (3) include the following:
- a. Monitoring,
- sampling, analysis, and reporting of radiation and radionuclides in the environment in accordance with the methodology and parameters in the REMODCM.
- b. A Land Use Census to ensure that changes in the use of areas at and beyond the SITE BOUNDARY are identified and that modifications to the monitoring program are made if required by the results of this census, and
- c. Participation in a Interlaboratory Comparison Program to ensure that independent checks on the precision and accuracy of the measurements of radioactive materials in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring.
6.17 REACTOR COOLANT PUMP FLYWHEEL INSPECTION PROGRAM This program shall provide for the inspection of each reactor coolant pump flywheel by either qualified in-place UT examination over the volume from the inner bore of the flywheel to the circle of one-half the outer radius or a surface examination (magnetic particle testing and/or penetrant testing) of exposed surfaces defined by the volume of the disassembled flywheels at least once every 10 years.
6.18 TECHNICAL SPECIFICATIONS (TS) BASES CONTROL PROGRAM This program provides a means for processing changes to the Bases of these Technical Specifications:
- a. Changes to the Bases of the TS shall be made under appropriate administrative controls and reviews.
- b. Licensees may make changes to Bases without prior NRC approval provided the changes do not require either of the following:
- 1. A change in the TS incorporated in the license or
- 2. A change to updated FSAR or Bases that requires NRC approval pursuant to 10 CFR 50.59.
Amendment No. 7Z#,
709, g7g, 215 MILLSTONE -
UNIT 3 0915 6-26
ADMINISTRATIVE CONTROLS
- c. The Bases Control Program shall contain provisions to ensure that the Bases are maintained consistent with the FSAR.
- d. Proposed changes that meet the criteria of Specification 6.18.b above shall be reviewed and approved by the NRC prior to implementation.
Changes to the Bases implemented without prior NRC approval shall be provided to the NRC on a frequency consistent with 10 CFR 50.71(e).
6.19 COMPONENT CYCLIC OR TRANSIENT LIMIT This program provided controls to track the FSAR, Section 3.9N, cyclic and transient occurrences to ensure that components are maintained within the design limits.
Amendment No. ?JZ,2l5 MILLSTONE - UNIT 3 0915 6-27