ML031340577

From kanterella
Jump to navigation Jump to search
Transmittal of Revision 41 Improved Technical Specifications Bases Manuals Unit 2
ML031340577
Person / Time
Site: Susquehanna 
Issue date: 05/07/2003
From:
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML031340577 (8)


Text

May. 07, 2003 Page 1

of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2003-23185 USER INFORMATION:

GE H *RO /

M EMPL#:28401 CA#: 0363 Address NUCSA2 Ph t259 4

TRANSMITTAL INFORMATION:

TO:

.tmni.

05/07/2003 LOCATION:

USNRC--

FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

<_THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:

ITSB2 -

IMPROVED TECHNICAL SPECIFICATIONS BASES MANUALS UNIT 2 REMOVE MANUAL TABLE OF CONTENTS DATE: 04/22/2003 ADD MANUAL TABLE OF CONTENTS DATE: 05/06/2003 CATEGORY: DOCUMENTS TYPE: ITSB2 ID:

ITSB2 REMOVE:

REV:40 ADD:

REV: 41 UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

2

TSB APPROVED AMENDMENT TO THE UNIT 2 TECHNICAL SPECIFICATIONS BASES MANUAL REVISION 41 Replace the following pages of the Technical Specifications Bases Manual with the enclosed pages. The revised pages are identified by Revision Number and contain vertical lines indicating the area of change.

g:Aic docs\\Js-wp51\\ts-manuaR0.00 Iists\\tsb rem ins.u1 u2.doc 4/30/03 REMOVE PAGES INSERT PAGES REV. #

TS / B LOES through TS B LOES 5 TS B LOES 1 through TS B LOES 5 41 TS I B 3.6-88 TS I B 3.6-88 2

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision TOC Table of Contents, 1

B 2.0 SAFETY LIMITS BASES Page TS I B 2.0-1 1

Pages TS / B 2.0-2 through TS B 2.0-4 2

Page TS I B 2.0-5 1

Pages B 2.0-6 through B 2.0-8 0

B 3.0 LCO AND SR APPLICABILITY BASES Pages B 3.0-1 through B 3.0-7 0

Pages TS I B 3.0-8 and TS / B 3.0-9 1

Pages B 3.0-10 through B 3.0-12 0

Pages TS I B 3.0-13 through TS I B 3.0-15 1

B 3.1 REACTIVITY CONTROL BASES Pages B 3.1-1 through B 3.1-51 0

B 3.2 POWER DISTRIBUTION LIMITS.B S S

Pages TS I B 3.2-1 through

- lS'243 1

Pages TS I B 3.2-5 and TS

3. 3-6' 2

Pages TS I B 3.2-7 aridMPS B.- 8 1

Page TS I B 3.2-9 K 2

Pages TS I B 3.2-1Ot hTS I B 3.2-19 1

B 3.3 INSTRUMENTAION-<

Pages TSi=B3-1 through TS I B 3.3-10 1

Page TSl 3' -11 2

Page B'3.3-12 through TS I B 3.3-27 1

Pag,es TS/ B'3.3-28 through TS I B 3.3-30 2

PagesTS4B 3.3-31

(

Pages TS/ B 3.3-32 and TS I B 3.3-33 2

,Pa,es TS / B 3.3-34 through TS I B 3.3-54 1

tkages B 3.3-55 through B 3.3-63 0

Pages TS / B 3.3-64 and TS / B 3.3-65 2

Page TS / B 3.3-66 3

Page TS / B 3.3-67 2

Page TS / B 3.3-68

.3 Pages TS / 3.3-69 through TS I B 3.3-75 2

Page TS I B 3.3-75a 4

Pages TS / B 3.3-75b through TS / B 3.3-75c 3

Pages B 3.3-76 through B 3.3-91 0

Pages.TS I B 3.3-92 through TS / B 3.3-103 1

Page TS / B 3.3-104 2

SUSQUEHANNA - UNIT 2 i

TS / B LOES-1 Revision 41

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.3-105 and TS I B 3.3-106 1

Page TS / B 3.3-107 2

Page TS I B 3.3-108 1

Page TS / B 3.3-109 2

Pages TS / B 3.3-110 through TS I B 3.3-115 1

Pages TS / B 3.3-116 and TS / B 3.3-117 2

Pages TS / B 3.3-118 through TS I B 3.3-123 1

Page TS / B 3.3-124 2

Page TS / B 3.3-124a 0

Pages TS I B 3.3-125 and TS / B3.3-126 1

Page TS I B 3.3-127 2

Pages TS I B 3.3-128 through TS I B 3.3-131 1

Page TS I B 3.3-132 2

Pages TS I B 3.3-133 and TS I B 3.3-134 1

Pages B 3.3-135 through B 3.3-137 0

Page TS / B 3.3-138 1

Pages B 3.3-139 through B 3.3-162 0

Page TS /B 3.3-163 1

Pages.B 3.3-164 through B 3.3-177 0

Pages TS/B 3.3-178 and TS/B 3.3-179 1

Page TS/B 3.3-179a 0

Pages TS / B 3.3-180 through TS / B 3.3-191 1

Pages B 3.3-192 through B 3.3-220 0

B 3.4 REACTOR COOLANT SYSTEM BASES Pages TS / B 3.4-1 through TS / B 3.4-9 1

Pages B 3.4-10 through B 3.4-14 0

Page TS I B 3.4-15 1

Pages TS / B 3.4-16 and TS / B 3.4-17 2

Page TS I B 3.4-18 1

Pages B 3.4-19 through B 3.4-28 0

Page TS I B 3.4-29 1

Pages B 3.3-30 through B 3.3-48 0

Page TS I B 3.4-49 2

Page TS / B 3.4-50 1

Page TS / B 3.4-51 2

Pages TS / B 3.4-52 and TS I B 3.4-53 1

Pages TS / B 3.4-54 and TS I B 3.4-55 2

Pages TS I B 3.4-56 through TS / B 3.4-60 1

B 3.5 ECCS AND RCIC BASES Pages TS I B 3.5-1 and TS I B 3.5-2 1

Page TS I B 3.5-3 2

SUSQUEHANNA - UNIT 2 TS / B LOES-2

-Revision 41

SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Title Revision Pages TS / B 3.5-4 through TS / B 3.5-10 1

Page TS / B 3.5-11 2

Pages TS I B 3.5-12 through TS I B 3.5-14 1

Pages TS I B 3.5-15 through TS / B.3.5-17 2

PageTS/B3.18 1

Pages B 3.5-19 through B 3.5-24 0

Page TS / B 3.5-25 1

Pages B 3.5-26 through B 3.5-31 0

B 3.6 CONTAINMENT SYSTEMS BASES Page TS / B 3.6-1 2

Page TS / B 3.6-la 3

Pages TS / B 3.6-2 through TS / B 3.6-5 2

Page TS / B 3.6-6 3

Pages TS / B 3.6-6a and TS B 3.6-6b 2

Page TS / B 3.6-6c 0

Pages B 3.6-7 through B 3.6-14 0

Page TS / B 3.6-15 3

Pages TS I B 3.6-15a and TS I B 3.6-15b 0

Page TS / B 3.6-16 1

Page TS / B 3.6-17 2

Page TS / B 3.6-17a 0

Pages TS / B 3.6-18 through TS / B 3.6-19 1

Page TS / B 3.6-20 2

Page TS / B 3.6-21 3

Pages TS / B 3.6-21a and TS / B 3.6-21b 0

Pages TS / B 3.6-22 and TS I B 3.6-23 2

Pages TS / B 3.6-24 through TS I B 3.6-26 1

Page TS / B 3.6-27 3

Page TS I B 3.6-28 6

Page TS I B 3.6-29 3

Page TS I B 3.6-29a 0

Page TS I B 3.6-30 2

Page TS I B 3.6-31 3

Pages TS / B 3.6-32 through TS 1 B 3.6-34 1

Pages TS B 3.6-35 through TS I B 3.6-37 2

Page TS I B 3.6-38 1

Page TS I B 3.6-39 3

Pages B 3.6-40 through B 3.6-42 0

Pages TS / B 3.6-43 through TS I B 3.6-50 1

PageTS/B3.6-51 2

Pages B 3.6-52 through B 3.6-62 0

Page TS I B 3.6-63 1

SUSQUEHANNA - UNIT 2 TS/B LOES-3 Revision 41 SUSQUEHANNA - UNIT 2 TS B LOES-3 Revision 41

-V SUSQUEHANNA STEAM ELECTRIC STATION LIST OFEFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Titte Revision Pages B 3.6-64 through B 3.6-82 0

Page TS I B 3.6-83 2

Pages TS / B 3.6-84 through TS / B 3.6-87 1

Page TS / B 3.6-87a I

Page TS / B 3.6-88 2

Pages TS / B 3.6-89 through TS I B 3.6-99 1

Pages B 3.6-100 through B 3.6-106 0

B 3.7 PLANT SYSTEMS BASES Pages TS / B 3.7-1 through TS / B 3.7-6 2

Page TS I B 3.7-6a 2

Pages TS I B 3.7-6b and TS / B 3.7-6c 0

Pages TS / B 3.7-7 and TS / B 3.7-8 1

Pages B 3.7-9 through B 3.7-11 0

Pages TS I B 3.7-12 and TS / B 3.7-13 1

Pages TS I B 3.7-14 through TS I B 3.7-18 2

Page TS I B 3.7-18a 0

Pages TS 1 B 3.7-19 through TS I B 3.7-23 1

Pages B 3.7-24 through B 3.7-33 0

B 3.8 ELECTRICAL POWER SYSTEMS BASES Pages B 3.8-1 through B 3.8-4 0

Page TS/B 3.8-5 1

Pages B 3.8-6 through B 3.8-18 0

Page TSI/ B 3.8-19 1

Pages B 3.8-20 through B 3.8-22 0

Page TS / B 3.8-23 1

Page B 3.8-24 0

Pages TS / B 3.8-25 and TS / B 3.8-26 1

Pages B 3.8-27 through B 3.8-37 0

Page TS I B 3.8-38 1

Pages TS / B 3.8-39 through TS / B 3.8-55 0

Pages TS / B 3.8-56 through TS I B 3.8-64 1

Page TS B 3.8-65 2

Page TS B 3.8-66 2

Pages TS I B 3.8-67 through TS I B 3.8-68 1

Page TS / B 3.8-69 2

Pages B 3.8-70 through B 3.8-99 0

B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS / B 3.9-2 1

Page TS I B 3.9-2a 1

Pages TS / B 3.9-3 and TS I B 3.9-4 1

SUSQUEHANNA - UNIT 2 TS/BLOES-4 Revision 41 SUSQUEHANNA - UNIT 2 TS / B LOES-4 Revision 41

r SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)

Section Titte Pages B 3.9-5 through B 3.9-30 B 3.10 SPECIAL OPERATIONS BASES Page TS / B 3.10-1 Pages B 3.10-2 through B 3.10-39 g:\\LicDocs\\TS-WP51\\TSManua\\0.00 LstsU2-TSB LOES.doc SUSQUEHANNA - UNIT 2 Revision 0

0 TS / B LOES-5 Revision 41

PPL Rev. 0 Secondary Containment B 3.6.4.1 BASES SURVEILLANCE REQUIREMENTS (continued)

SR 3.6.4.1.4 and SR 3.6.4.1.5 The SGT System exhausts the secondary containment atmosphere to the environment through appropriate treatment equipment. To ensure that all fission products are treated, SR 3.6.4.1.4 verifies that the SGT System will rapidly establish and maintain a pressure in the secondary containment that is less than the pressure external to the secondary containment boundary.

This is confirmed by demonstrating that one SGT subsystem will draw down the secondary containment to > 0.25 inches of vacuum water gauge in less than or equal to the maximum time allowed. This cannot be accomplished if the secondary containment boundary is not intact. SR 3.6.4.1.5 demonstrates that one SGT subsystem can maintain 2 0.25 inches of vacuum water gauge for at least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at less than or equal to the maximum flow rate permitted for the secondary containment configuration that is operable. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> test period allows secondary containment to be in thermal equilibrium at steady state conditions. As noted, both SR 3.6.4.1.4 and SR 3.6.4.1.5 acceptance limits are dependent upon the secondary containment configuration when testing is being performed. The acceptance criteria for the SRs based on secondary containment configuration is defined as follows:

SECONDARY MAXIMUM DRAWNDOWN TIME(SEC)

MAXIMUM FLOW RATE (CFM)

CONTAINMENT (SR 3.6.4.1.4 (SR 3.6.4.1.5 CONFIGURATION ACCEPTANCE CRITERIA)

ACCEPTANCE CRITERIA)

Three Zone Operation with

<15 Seconds

<2960 CFM From Zones II and III Zone I OPERABLE.

(Zones II and ll)

(Verify by calculation that one SGT subsystem will maintain 2.25 inches of vacuum water gauge in secondary containment at a flow rate of < 4000 CFM (From Zones I II, and III.)

Three Zone Operation with

< 125 Seconds s 4000 CFM Zones I, II and IlIl.

(Zones I, II, and Ill)

(From Zones I, II, and Ill)

Two Zone Operation with 1 8 Seconds s 2960 CFM Unit 1.Shutdown and (Zones II and ll)

(From Zones II and III)

Zone I isolated.

Only one of the above listed configurations needs to be tested to confirm secondary containment OPERABILITY.

(continued)

SUSQUEHANNA - UNIT 2 n

. 17 1

i 11 I

TS/IB 3.6-88 Revision 2