May. 07, 2003 Page 1
of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2003-23059 USER INFORMATION:
GER EMPL#:28401 CA#: 0363 Addre NUCSA2 P+/-.i1#: 2'Nc39 TRANSMITTAL INFORMATION:
TO:
prfLAOIIrr & M 05/07/2003 LOCATION:
USNRC-g FROM:
NUCLEAR RECORDS DOCUMENT CONTROL CENTER
- NUCSA-2)
\\---HE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:
ITSB1 -
IMPROVED TECHNICAL SPECIFICATIONS MANUAL BASES UNIT 1 REMOVE MANUAL TABLE OF CONTENTS DATE: 04/22/2003 ADD MANUAL TABLE OF CONTENTS DATE: 05/06/2003 CATEGORY: DOCUMENTS TYPE: ITSB1 ID:
ITSB1 REMOVE:
REV:42 ADD:
REV: 43 UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
tObO
TSB APPROVED AMENDMENT TO THE UNIT I TECHNICAL SPECIFICATIONS BASES MANUAL REVISION 43 Replace the following pages of the Technical Specifications Bases Manual with the enclosed pages. The revised pages are identified by Revision Number and contain vertical lines indicating the area of change.
REMOVE PAGES INSERT PAGES REV. #
TS / B LOES 1 through TS / B LOES 5 TS / B LOES 1 through TS / B LOES 5 43 TS I B 3.6-89 TS / B 3.6-89 2
g:Uic docs\\ts-wp51ts-manuaO.OO lists\\tsb rem ins.ulu2.doc 4t30103
SUSQUEHANNA STEAM ELECTRIC STATION LST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Tite Revision TOC Table of Contents 1
B 2.0 SAFETY LIMITS BASES Page B 2.0-1 0
Page TS/B 2.0-2 1
Pages TS/B 2.0-3 through TSB 2.0-5 1
corrected Page TS/B 2.0-6 1
Pages B 2.0-7 through B 2.0-9 0
B 3.0 LCO AND SR APPLICABILITY BASES Pages B 3.0-1 through B 3.0-7
/
0 Pages TS / B 3.0-8 and TS / B 3.0-9
,1.,-
I Page B 3.0-10 through B 3.0-12 0
Pages TS /B 3.0-13 through TS I B 3.0-15 1
B 3.1 REACTIVITY CONTROL BASES Pages B 3.1-1 through B 3.1-51 0
0 B 3.2 POWER DISTRIBUTION LIMITS BASES'N.,'
Page B 3.2-1 j
10 Page TS/B 3.2-2 1
I Page B 3.2-3 0
K)
Pages TS/B 3.2-4through TS/B 3.2-6 1
Pages B 3.2-7 and B 3.2-8, 'i 0
Page TS/B 3.29 < I Page B 3.2-10 0
Page TS/B 3.2-11 1
PageB 2-12,2'"
0 Page TS/B 3.2-13 1
Pages B 3.2-14 and B 3.2-15 0
, < Page,TS/B 3.2-16 1
r, rtPagesB 3.2-17 and 3.2-18 0
,,Page,TS/B 3.2-19 1
B 3.3 INSTRUMENTATION Pages TS / B 3.3-1 through TS I B 3.3-10 1
Page TS I B 3.3-11 2
Pages TS / B 3.3-12 through TS / B 3.3-27 1
Pages TS / B 3.3-28 through TS / B 3.3-31 2
Pages TS / B 3.3-32 and TS / B 3.3-33 3
Pages TS I B 3.3-34 through TS I B 3.3-54 1
Pages B 3.3-55 through B 3.3-63 0
Pages TS B 3.3-64 and TS B 3.3-65 2
Page TS B 3.3-66 3
Page TS / B 3.3-67 2
Page TS / B 3.3-68 3
V ~
SSUHNA-UI S/BLE-eiin4 SUSQUEHANNA -UNIT 1 -
TS / B LOES-1 Revision 43
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Corrected Pages TS / B 3.3-69 through TS I B 3.3-75 2
Page TS / B 3.3-75a 4
Pages TS / B 3.3-75b through TS / B 3.3-75c 3
Pages B 3.3-76 through B 3.3-91 0
Page TS / B 3.3-92 through TS / B 3.3-1 00 1
Pages B 3.3-101 through B 3.3-103 0
Page TS / B 3.3-104 1
Pages B 3.3-105 and B 3.3-106 0
Page TS / B 3.3-107 1
Page B 3.3-108 0
Page TS / B 3.3-109 1
Pages B 3.3-110 and B 3.3-111 0
Pages TS/B 3.3-112 and TS/B 3.3-112a 1
Pages B 3.3-113 and B 3.3-114 0
Page TS I B 3.3-115 1
Page TS B3.3-116 2
Page TS B 3.3-117 1
Pages B 3.3-118 through B 3.3-122 0
Pages TS / B 3.3-123 through TS I B 3.3-124 1
Page TS / B 3.3-124a 0
Pages B 3.3-125 and B 3.3-126 0
Page TS / B 3.3-127 1
Pages B 3.3-128 through B 3.3-130 0
Page TS /B3.3-131 1
Pages B 3.3-132 through B 3.3-137 0
Page TS / B 3.3-138 1
Pages B 3.3-139 through B 3.3-162 0
Page TS / B 3.3-163 1
Pages B 3.3-164 through B 3.3-177 0
Pages B 3.3-178 and B 3.3-179 1
Page B 3.3-179a 0
Pages TS / B 3.3-180 through TS I B 3.3-191 1
Pages B 3.3-192 through B 3.3-219 0
B 3.4 REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 and B 3.4-2 0
Pages TSIB 3.4-3 and TS/B 3.4-4 1
Pages B 3.4-5 through B 3.4-14 0
Page TS / B 3.4-15 1
Pages TS /
3.4-16 and TS /B 3.4-17 2
Page TS /B3.4-18 1
Pages B 3.4-19 through B 3.4-28 0
Page TS B 3.4-29 1
Pages B 3.4-30 through B 3.4-48 0
Page TS B 3.4-49 2
Page TS/ B 3.4-50 1
SUSQUEHANNA - UNIT 1 TS / B LOES-2 Revision 43
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
USection Title Revision Page TS I B 3.4-51 2
Pages TS / B 3.4-52 and TS I B 3.4-53 1
Page TS I B 3.4-54 2
Page TS I B 3.4-55 2
Page TS I B 3.4-56 1
Page TS I B 3.4-57 2
Pages TS / B 3.4-58 through TS I B 3.4-60 1
B 3.5 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 0
Page TS / B 3.5-3 2
Pages B 3.5-4 through B 3.5-10 0
Page TS / B 3.5-11 1
Pages B 3.5-12 through B 3.5-15 0
Pages TS / B 3.5-16 through TS / B 3.5-18 1
Pages B 3.5-19 through B 3.5-24 0
Page TS / B 3.5-25 1
Pages B 3.5-26 through B 3.5-31 0
B 3.6 CONTAINMENT SYSTEMS BASES Page TS / B 3.6-1 2
Page TS / B 3.6-1 a 3
Pages TS / B 3.6-2 through TS I B 3.6-5 2
Page TS / B 3.6-6 3
Pages TS / B 3.6-6a and TS / B 3.6-6b 2
Page TS / B 3.6-6c 0
Pages B 3.6-7 through B 3.6-14 0
Page TS I B 3.6-15 2
Pages TS I B 3.6-15a and TS I B 3.6-15b 0
Page B 3.6-16 0
Page TS / B 3.6-17 1
Page TS / B 3.6-17a 0
Pages TS / B 3.6-18 and TS I B 3.6-19 0
Page TS / B 3.6-20 1
Page TS / B 3.6-21 2
Page TS / B 3.6-22 1
Page TS I B 3.6-22a 0-Page TS / B 3.6-23 1
Pages TS / B 3.6-24 through TS / B 3.6-25 0
Page TS/B 3.6-26 0
Corrected Page TS / B 3.6-27 2
Page TS / B 3.6-28 5
Page TS / B 3.6-29 1
Page TS/B 3.6-30 1
Page TS / B 3.6-31 3
Pages B 3.6-32 through B 3.6-35 0
SUSQUEHANNA - UNIT I TS I B LOES-3 Revision 43 SUSQUEHANNA - UNIT 1 TS / B LOES-3 Revision 43
s N
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Page TS / B 3.6-36 1
Page B 3.6-37 0
Page TS/B 3.6-38 1
Page B 3.6-39 0
Page TS I B 3.6-40 2
Pages B 3.6-41 through B 3.6-43 0
Pages TS I B 3.6-44 through TS I B 3.6-51 1
Page TS / B 3.6-52 2
Pages B 3.6-53 through B 3.6-63 0
Page TS I B 3.6-64 1
Pages B 3.6-65 through B 3.6-83 0
Pages TS / B 3.6-84 2
Pages TS / B 3.6-85 through TS I B 3.6-88 1
Page TS / B 3.6-88a Page TS I B 3.6-89 2
Pages TS / B 3.6-90 through TS I B 3.6-100 1
Pages B 3.6-101 through B 3.6-107 0
B 3.7 PLANT SYSTEMS BASES Pages TS / B 3.7-1 through TS I B 3.7-6 2
Page TS / B 3.7-6a 2
Pages TS 1 13 3.7-6b and TS I B 3.7-6c 0
Pages TS I B 3.7-7 through TS I B 3.7-11 Pages TS I B 3.7-12 and TS I B 3.7-13 1
Pages TS B 3.7-14 through TS I B 3.7-18 2
Page TS / B 3.7-18a 0
Pages TS / B 3.7-19 through TS / B 3.7-23 1
Pages B 3.7-24 through B 3.7-26 0
Pages TS / B 3.7-27 through TS I B 3.7-29 2
Page TS / B 3.7-30 1
Pages B 3.7-31 through B 3.7-33 0
B 3.8 ELECTRICAL POWER SYSTEMS BASES Pages TS I B 3.8-1 through TS I B 3.8-4 2
Page TS / B 3.8-5 3
Pages TS / B 3.8-6 through TSIB 3.8-17 2
Page TS I B 3.8-18 3
Pages TS I B 3.8-19 through TS B 3.8-21 2
Pages TS I B 3.8-22 and TS I B 3.8-23 3
Pages TS I B 3.8-24 through TS / B 3.8-37 2
Pages B 3.8-38 through B 3.8-53 0
Pages TS I B 3.8-54 through TS I B 3.8-61 1
Page TS / B 3.8-62 2
Page TS / B 3.8-63 2
Page TS / B 3.8-64 1
Page TS / B 3.8-65 2
Pages TSIB 3.8-66 through B 3.8-90 0
SUSQUEHANNA - UNIT I TS/B LOES-4 Revision 43 Revision 43 SUSQUEHANNA - UNIT 1 TS B LOES-4
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Titte B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS / B 3.9-1 a Pages TS / B 3.9-2 through TS / B 3.9-4 Pages B 3.9-5 through B 3.9-30 B 3.10 SPECIAL OPERATIONS BASES Page TS I B 3.10-1 Pages B 3.10-2 through B 3.10-38 g:\\LicDocs\\TS-WP51\\TS-Manual\\0.00 Lists\\U1-TSB LOES.doc SUSQUEHANNA - UNIT 1 Revision I
I 0
1 0
TS / B LOES-5 Revision 43
PPL Rev. 0 Secondary Containment B 3.6.4.1 BASES SURVEILLANCE REQUIREMENTS (continued)
SR 3.6.4.1.4 and SR 3.6.4.1.5 The SGT System exhausts the secondary containment atmosphere to the environment through appropriate treatment equipment. To ensure that all fission products are treated, SR 3.6.4.1.4 verifies that the SGT System will rapidly establish and maintain a pressure in the secondary containment that is less than the pressure extemal to the secondary containment boundary.
This is confirmed by demonstrating that one SGT subsystem will draw down the secondary containment to 2 0.25 inches of vacuum water gauge in less than or equal to the maximum time allowed. This cannot be accomplished f the secondary containment boundary is not intact. SR 3.6.4.1.5 demonstrates that one SGT subsystem can maintain 2 0.25 inches of vacuum water gauge for at least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at less than or equal to the maximum flow rate permitted for the secondary containment configuration that is operable. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> test period allows secondary containment to be in thermal equilibrium at steady state conditions. As noted, both SR 3.6.4.1.4 and SR 3.6.4.1.5 acceptance limits are dependent upon the secondary containment configuration when testing is being performed. The acceptance criteria for the SRs based on secondary containment configuration is defined as follows:
SECONDARY MAXIMUM DRAWNDOWN TIME(SEC)
MAXIMUM FLOW RATE (CFM)
CONTAINMENT (SR 3.6.4.1.4 (SR 3.6.4.1.5 CONFIGURATION ACCEPTANCE CRITERIA)
ACCEPTANCE CRITERIA)
Three Zone Operation with s15 Seconds
< 2885 CFM From Zones I and IlIl Zone OPERABLE.
(Zones I and ll)
(Verify by calculation that one SGT subsystem will maintain Ž.25 inches of vacuum water gauge in secondary containment at a flow rate of < 4000 CFM (From Zones I, II, and 1II)).
Three Zone Operation with
- 125 Seconds
< 4000 CFM Zones, ll and ll.
(Zones, ll, and ll)
(From Zones, ll, and ll)
Two Zone Operation with
< 117 Seconds
< 2885 CFM Unit 2 Shutdown and (Zones I and 1II)
(From Zones I and 1II)
Zone ll isolated.
(continued)
SUSQUEHANNA - UNIT I I
I TS / B3.6-89 Revision 2