ML031250063

From kanterella
Jump to navigation Jump to search
Registration of Use of Dry Spent Fuel Transportable Storage Canister Identification No. AMZDFX002
ML031250063
Person / Time
Site: Palo Verde  
Issue date: 04/25/2003
From: Bauer S
Arizona Public Service Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
-RFPFR, 102-04932-SAB/TNW/GAM
Download: ML031250063 (2)


Text

A Sct A10 CFR 72.212(b)(1)(ii) 1h~A~Scott A. Bauer Department Leader Regulatory Affairs Tel 623/393-5978 Mail Station 7636 Palo Verde Nuclear Fax 623/393-5442 P O Box 52034 Generating Station e-mail sbauer~apsc corn Phoenix, AZ 85072-2034 102-04932-SAB/TNW/GAM April 25, 2003 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-37 Washington, DC 20555-0001

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 2 and Independent Spent Fuel Storage Installation (ISFSI)

Docket Nos. STN 50-529 and 72 -/- /0/I Registration of Use of Dry Spent Fuel Transportable Storage Canister Identification No. AMZDFX002 In accordance with 10 CFR 72.212(b)(1)(ii), Arizona Public Service Company (APS) is registering the use of a dry spent fuel storage cask to store spent fuel under a 10 CFR Part 72 general license at the PVNGS Independent Spent Fuel Storage Installation (ISFSI). The information below is provided for transportable storage canister (TSC) identification no. AMZDFX002 used to store spent fuel within vertical concrete cask (VCC) no. AMZDNE002 beginning on April 15, 2003.

Licensee's Name:

Arizona Public Service Company (APS) is the operating agent for the seven PVNGS owner licensees.

PVNGS Units 1, 2, and 3 have seven owners who are licensees. The owners/licensees are APS, Salt River Project Agricultural Improvement and Power District, El Paso Electric Company, Southern California Edison Company, Public Service Company of New Mexico, Los Angeles Department of Water and Power, and Southern California Public Power Authority. According to the PVNGS operating licenses, APS is authorized to act as agent for the PVNGS licensees and has exclusive responsibility and control over the physical construction, operation and maintenance of the facility.

Licensee's Address:

Arizona Public Service Company P. 0. Box 52034 Phoenix, AZ 85072-2034 A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway

  • Comanche Peak
  • Diablo Canyon
  • Palo Verde
  • Wolf Creek

U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Registration of Use of Dry Spent Fuel Storage Canister Page 2 Reactor:

Palo Verde Nuclear Generating Station Unit 2 NPF-51 License Number:

Docket Number:

STN 50-529 Contact Name and

Title:

Thomas N. Weber, Section Leader, Licensing Cask Certificate No.:

Cask Model No.:

Cask Identification Nos.:

Certificate of Compliance No. 1015, Amendment No. 2, December 31, 2001 NAC-UMS Transportable Storage Canister (TSC) Identification No. AMZDFX002 Vertical Concrete Cask (VCC) Identification No.

AMZDNE002 The heat load in this cask is less than 10 kW and therefore does not meet the criteria for reporting the heat transfer characteristics described in the NAC-UMS Technical Specification A 5.3, "Special Requirements for the First System Placed in Service."

No commitments are being made to the NRC by this letter.

Should you have any questions, please contact Thomas N. Weber at (623) 393-5764.

Sincerely, SABITNW/GAM cc:

E. W. Merschoff J. N. Donohew N. L. Salgado S. C. O'Connor A. V. Godwin

[NRC Region IV]

[NRC/NRR Project Manager]

[NRC Senior Resident Inspector]

[NRC SFPO]

[ARRA]