[ Robert Tregoning - Dimensioned Photos of the DB Cavity "Dental" Mold
-___!Page 1 From:
Mark Kirk /
To:
Bass, Richard - ORNL; Williams, Paul - ORNL Date:
10/24/02 10:05AM
Subject:
Dimensioned Photos of the DB Cavity "Dental" Mold All -
I am pleased to attach a file i received from Mike Leisure at Davis Besse Licensing. Some time ago Mike had agreed to work with personnel at the Framatome hot cells to obtain dimensioned photos of the "Dental" mold of the Davis Besse Cavity. Attach you will find the results of his efforts. These photos should be of great benefit to us in developing an finite element representation of the wastage cavity that has both true size and shape.
Enjoy!
Mark CC:
Deborah Jackson; Gary Demoss; Jon Hopkins; Michael Mayfield; Nilesh Chokshi; Robert Tregoning; Steven Long; William Cullen
>>> <mkleisure@firstenergycorp.com> 10/23/02 06:41AM >>>
Mark Kirk-Attached are the four photos you requested of the Davis-Besse reactor head cavity mold.
(See attached file: Mold Macros 10-22-02.doc)
Mike Leisure Davis-Besse Licensing (419)321-7168 9O0 I
) 4I1800 Ij 00 Place exposed cladding surface Flat down on table 2700 I
Orientation of photos on following pages.
Davis-Besse Cavity Mold at O° -0.52X Davis-Besse Cavity Mold at Y0- -0.5 /A
Davis-Besse Cavity Mold at 2700 0.55X