March 2003 Monthly Operating Report for Donald C. Cook Nuclear Plant, Units 1 & 2
ML031070435
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 04/11/2003
From: Jack Giessner
Indiana Michigan Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
AEP:NRC:2691-29
Download: ML031070435 (8)


Text

Indiana Michigan Power Company 500 Circle Drive Buchanan, Ml 49107 1373 INDIANA MICHIGAN POWER April 11, 2003 AEP:NRC:2691-29 Docket Nos. 50-315 50-316 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant Units I and 2 MONTHLY OPERATING REPORT Pursuant to the requirements of Donald C. Cook Nuclear Plant Unit 1 and Unit 2 Technical Specification 6.9.1.8, the attached Monthly Operating Report for March 2003 is submitted.

Sincerely, Director Design Engineering and Regulatory Affairs BWO/rdw Attachment 2*4AC

U. S. Nuclear Regulatory Commission AEP:NRC:2691-29 Page 2 c: ANI Nuclear Engineering Department A. C. Bakken, III L. Brandon - Department of Health M. J. Finissi G. T. Gaffney - Canton J. B. Giessner S. Hamming - Department of Labor RAF Harris INPO Records Center B. Lewis - McGraw-Hill Companies D. H. Malin K. L. Matheny B. A. McIntyre NRC Project Manager - NRR NRC Region III NRC Resident Inspector D. W. Paul - Columbus J. E. Pollock W. H. Schalk

N.R.C. OPERATING DATA REPORT DOCKET NO. 50-315 DATE 4/2103 COMPLETED BY T Pham TELEPHONE 269-465-5901 OPERATING STATUS

1. Unit Name D.C. Cook Unit I Notes:
2. Reporting Period Mar-03
3. Licensed Thermal Power (MWt) 3304
4. Name Plate Rating (Gross MWe) 1152
5. Design Electrical Rating (Net MWe) 1020
6. Maximum Dependable Capacity(GROSS MWe) 1056
7. Maximum Dependable Capacity (Net MWe) 1000
8. If Changes Occur InCapacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If Any (Net MWe)
10. Reasons For Restrictions.

This Mo. Yr. to Date Cumm.

11. Hours in Reporting Period 744.0 2160.0 247608.0
12. No. of Hrs. Reactor Was Critical 744.0 1695.2 169043.8
13. Reactor Reserve Shutdown Hours 0.0 0.0 463.0
14. Hours Generator on Une 744.0 1673.6 166362.5
15. Unit Reserve Shutdown Hours 0.0 0.0 321.0
16. Gross Therm. Energy Gen. (MWH) 2456661.4 5474006.0 495743080.6
17. Gross Elect. Energy Gen. (MWH) 798010.0 1777460.0 161019890.0
18. Net Elect. Energy Gen. (MWH) 771765.0 1718515.5 154993712.0
19. Unit Service Factor 100.0 77.5 67.7
20. Unit Availability Factor 100.0 77.5 67.7
21. Unit Capacity Factor (MDC Net) 103.7 79.6 64.0
22. Unit Capacity Factor (DER Net) 101.7 78.0 62.8
23. Unit Forced Outage Rate 0.0 22.5 19.2
24. Shutdowns Scheduled over Next Six Months (TypeDate,and Duration):
25. If Shut Down At End of Report Period, Est'd Date of Startup: -
26. Units In Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO. 50-315 UNIT ONE DATE 02-Apr-03 COMPLETED BY T Pham TELEPHONE 269-465-5901 MONTH Mar-03 AVERAGE DAILY AVERAGE DAILY DAY POWER LEVEL DAY POWER LEVEL 3/11/03 1040 3/17/03 1037 3/2103 1042 3/18/03 1040 3/3/03 1035 3/19103 1036 3/4/03 1036 3/20/03 1030 3/5/03 1044 3/21/03 1039 3/6/03 1041 3/22/03 1039 317/03 1037 3/23/03 1033 3/8/03 1042 3124/03 1035 3/9/03 1038 3125/03 1037 3/10/03 1042 3/26/03 1035 3/11/03 1035 3/27/03 1031 3/12/03 1036 3/28/03 1034 3113103 1038 3/29/03 1040 3/14/03 1035 3/30/03 1031 3115/03 1036 3/31/03 1046 3/16/03 1038

DOCKET NO. 50-315 UNIT NAME D.C. Cook Unit I DATE April 2, 2003 COMPLETED BY B. O'Rourke TELEPHONE 269-465-5901 PAGE 1of 1 UNIT SHUTDOWNS AND POWER REDUCTIONS - March 2003 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO. DATE TYPE1 HOURS REASON 2 REACTOR 3 REPORT NO. CODE 4 CODE 5 TO PREVENT RECURRENCE None 1 TYPE: 2 REASON: 3 METHOD: 4 SYSTEM: 5 COMPONENT:

F: Forced A: Equipment Failure (Explain) 1: Manual Exhibit G - Instructions Exhibit l: Same Source S: Scheduled B: Maintenance or Test 2: Manual Scram for preparation of data C: Refueling 3: Automatic Scram entry sheets for Licensee D: Regulatory Restriction 4: Other (Explain) Event Report (LER) File E: Operator Training and (NUREG 0161)

License Examination F: Administrative G: Operational Error (Explain)

H: Other (Explain)

N.R.C. OPERATING DATA REPORT DOCKET NO. 50-316 DATE 4/2/03 COMPLETED BY T Pham TELEPHONE 269-465-5901 OPERATING STATUS

1. Unit Name D.C. Cook Unit 2 Notes:
2. Reporting Period Mar-03
3. Licensed Thermal Power (MWt) 3411
4. Name Plate Rating (Gross MWe) 1133
5. Design Electrical Rating (Net MWe) 1090
6. Maximum Dependable Capacity(GROSS MWe) 1100
7. Maximum Dependable Capacity (Net MWe) 1060
8. If Changes Occur InCapacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons
9. Power Level To Which Restricted. If Any (Net MWe)
10. Reasons For Restrictions.

This Mo. Y'r.to Date Cumm.

11. Hours in Reporting Period 744.0 2160.0 221754.0
12. No. of Hrs. Reactor Was Critical 744.0 1884.6 143452.7
13. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
14. Hours Generator on Line 744.0 -1849.1 139589.6
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Therm. Energy Gen. (MWH) 2536498.7 45215442.3 437439139.6
17. Gross Elect. Energy Gen. (MWH) 843740.0 2060580.0 141834280.0
18. Net Elect. Energy Gen. (MWH) 818582.0 1997487.8 136750227.1
19. Unit Service Factor 100.0 85.6 63.6
20. Unit Availability Factor 100.0 85.6 63.6
21. Unit Capacity Factor (MDC Net) 103.8 87.2 59.3
22. Unit Capacity Factor (DER Net) 100.9 84.8 57.7
23. Unit Forced Outage Rate 0.0 14.4 23.7
24. Shutdowns Scheduled over Next Six Months (Type,Date,and Duration):

Rpfeplinn tiAenp achpduiedd fnr Mavn 2003.

25. If Shut Down At End of Report Period, Est'ed Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

v AVERAGE DAILY POWER LEVEL (MWeNet)

DOCKET NO. 50-316 UNIT TWO DATE 2-Apr-03 COMPLETED BY T Pham TELEPHONE 269-465-5901 MONTH Mar-03 AVERAGE DAILY AVERAGE DAILY DAY POWER LEVEL DAY POWER LEVEL 311/03 1102 3/17/03 1102 312/03 1101 3118/03 1095 3/3/03 1101 3119/03 1101 314/03 1104 3/20/03 1102 3/5/03 1102 3/21/03 1102 3/6103 1111 3/22/03 1098 317/03 1103 3/23/03 1094 3/8/03 1097 3/24/03 1102 3/9103 1100 3/25/03 1097 3/10/03 1093 3/26/03 1106 3111/03 1095 3/27/03 1101 3112103 1101 3/28/03 1094 3113103 1102 3/29/03 1097 3114/03 1097 3/30/03 1099 3115103 1101 3/31/03 1103 3116/03 1106

DOCKET NO. 50 - 316 UNIT NAME D.C. Cook Unit 2 DATE April 2, 2003 COMPLETED BY B. O'Rourke TELEPHONE 269-465-5901 PAGE 1 of I UNIT SHUTDOWNS AND POWER REDUCTIONS - March 2003 METHOD OF SHUTTING LICENSEE DURATION DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION NO. DATE TYPE 1 HOURS REASON 2 REACTOR 3 REPORT NO. CODE 4 CODE 5 TO PREVENT RECURRENCE None 1 TYPE: 2 REASON: 3 METHOD: 4 SYSTEM: 5 COMPONENT:

A: Equipment Failure (Explain) 1: Manual Exhibit G - Instructions Exhibit l: Same Source F: Forced S: Scheduled B: Maintenance or Test 2: Manual Scram for preparation of data C: Refueling 3: Automatic Scram entry sheets for Licensee D: Regulatory Restriction 4: Other (Explain) Event Report (LER) File E: Operator Training and (NUREG 0161)

License Examination F: Administrative G: Operational Error (Explain)

H: Other (Explain)