ML030980627
| ML030980627 | |
| Person / Time | |
|---|---|
| Site: | McGuire, Mcguire (NPF-009, NPF-017) |
| Issue date: | 04/04/2003 |
| From: | NRC/RGN-II |
| To: | |
| References | |
| Download: ML030980627 (20) | |
Text
Annual Assessment Meeting McGuire Nuclear Station I
.?t Nuclear Regulatory Commission April 4, 2003
Annual Licensee Assessment Meeting mA public forum for discussion of the Iicensee's performance as outlined jn the NRC' S Annual Assessment Letter
- Provide licensee with an opportunity to respond to the information in the Assessment Letter
NRC Performance Goals
- Maintain safety and protect the environment
- Enhance public confidence
- Improve effectiveness, efficiency, and realism of processes and decision making
- Reduce unnecessary regulatory burden
Exhibit 1: REGULATORY FRAMEWORK Strategic Perfotmance Areas Comerstones
HUMLAN ------------------ SAFETY CONSCIOUS WORK -------------------- PROBLEM ------------------
PERFORMANCE ENVIRONMENT IDENTIFICATION AND
\\-
I RESOLUTION Cross-Cutting Areas
Reactor Oversight Process Strategic Performance Areas Safety Cornerstones Inspection Results 4
I=
'T Regulatory Response
Key Aspects of the Assessment Program
- Objective review of licensee performance
- "Action Matrix" identifies agency response commensurate with safety significance
- Increasing safety significance results in:
- Increased levels of inspection
- Involvement of higher levels of NRC and Licensee management
- Increased regulatory action
- Plant specific assessment information on NRC public web site:
- http:llwww.nrc.gov/NRR/ OVERSIGHT/ASSESS/
actionmatrixsummary.html
NRC Inspection Activities in 2002
- Base Line
- Reactor Pressure Vessel Head and Penetration Nozzles
- Security Interim Compensatory Measures (partial)
- Problem Identification & Resolution
- Safety System Design and Performance Capability
- Independent Spent Fuel Storage Installation
Fourth Quarter 2002 Performance Summary Performance Indicators UNIT 1 Performance Indicators
YEAR 2002 Performance Summary Most Significant Inspection Findings UNIT 1 Most Significant Inspection Findings 4Qr2002 3Q02002 20/2002 1012002
Fourth Quarter 2002 Performance Summary Performance Indicators UNIT 2 Performance Indicators
_I
YEAR 2002 Performance Summary Most Significant Inspection Findings UNIT 2 Most Significant Inspection Findings 4Q02002 302002 2Q12002 1Q12002
Greater than GREEN Findings and PIs (Details)
- All Findings and Pis Were Green
ROP Action Matrix Summary for 2002
- Column 1-Licensee Response
- Column 2 - Regulatory Response
- Column 3 - Degraded Cornerstone
- Column 4 - Multiple/ Repetitive Degraded Cornerstone
- Column 5 - Unacceptable Performance (Nationwide number does not contain Davis Besse)
Column 1 Column 2 Column 3 Column 4 Column 5 Nationwide 59 33 7
3 0
Region l 9
14 2
1 0
Region II 26 4
1 1
0 Region lll 11 10 2
0 0
Region IV 13 5
2 1
0
Security & Safeguards Update
- Creation of Office of Nuclear Sec urity and Incident Response
- Top-to-Bottom Review of Security Program Initiated
- issuance Measures of Orders/ Interim Compensatory (ICM)
- Verification of Licensee Actions on 1CM
Security & Safeguards Update
- Proposed Revisions to Design Basis Threat
- Pending Orders on Fatigue/Guard Training
- Initiation of Pilot Force-on-Force Exercise Program
Contacts for additional information for:
McGuire Nuclear Station
- Regional Public Affairs Officer:
- Name: Kenneth Clark
- Phone: (404) 562 - 4416
- State Liaison Officer:
- Name: Robert Trojanowski
- Phone: (404) 562 - 4427
- Branch Chief:
- Name: Robert Haag
- Phone: (404) 562 - 4550
- Senior Resident Inspector:
- Name: Scott Shaeffer (Joe Brady as of 6/2003)
- Phone: (704) 875 - 1681
Contacting the NRC
- Report an emergency
- (301) 816-5 100 (call collect)
- Report a safety concern:
- (800) 695-7403
- Allegation@ nrc.gov
- General information or questions
- www.nrc.gov
- Select 'What We Do" for Public Affairs
Regional Organization
Regional Organization