Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.1 Offsite Dose Calculation Manual (ODCM)

(continued)

Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (i.e.,

month and year) the change was implemented.

5.5.2 Primary Coolant Sources Outside Containmeant This program provides controls to minimize leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to levels as low as practicable.

The systems include the Low Pressure Core Spray, High Pressure Core Spray, Residual Heat Removal/Low Pressure Coolant Injection, Reactor Core Isolation Cooling, hydrogen recombiner, process sampling (until such time as a modification eliminates the PASS penetration as a potential leakage path), containment monitoring and Standby Gas Treatment.

The program shall include the following:

a.

Preventive maintenance and periodic visual inspection requirements; and

b.

Integrated leak test requirements for each system at 24 month intervals.

The provisions of SR 3.0.2 are applicable to the 24 month Frequency for performing integrated system leak test activities.

5.5.3 Deleted.

(continued)

LaSalle I and 2 Amendment No. 158 and 144 5.5-2