March 18, 2003 MEMORANDUM TO: Richard J. Laufer, Chief, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM: Timothy G. Colburn, Senior Project Manager, Section 1 /RA/

Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

QUESTIONS FAXED TO THE LICENSEE RE: BEAVER VALLEY POWER STATION, UNIT 1 (BVPS 1) PRE-OUTAGE STEAM GENERATOR CONFERENCE CALL (TAC NO. MB7271)

The attached questions have been faxed to the BVPS 1 licensee regarding the NRC staffs requested steam generator pre-outage telephone call. These questions were discussed with the licensee during a conference call held on March 5, 2003.

Docket No. 50-334

Attachment:

As stated

March 18, 2003 MEMORANDUM TO: Richard J. Laufer, Chief, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM: Timothy G. Colburn, Senior Project Manager, Section 1 /RA/

Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

QUESTIONS FAXED TO THE LICENSEE RE: BEAVER VALLEY POWER STATION, UNIT 1 (BVPS 1) PRE-OUTAGE STEAM GENERATOR CONFERENCE CALL (TAC NO. MB7271)

The attached questions have been faxed to the BVPS 1 licensee regarding the NRC staffs requested steam generator pre-outage telephone call. These questions were discussed with the licensee during a conference call held on March 5, 2003.

Docket No. 50-334

Attachment:

As stated DISTRIBUTION:

PUBLIC PDI-1 Reading RLaufer MOBrien TColburn Accession Number: ML030770052 OFFICE PDI-1/PM PDI-1/LA PDI-1/SC NAME TColburn MOBrien RLaufer DATE 3/5/03 3/6/03 3/11/03 OFFICIAL RECORD COPY

QUESTIONS FOR BEAVER VALLEY POWER STATION, UNIT 1 PRE-OUTAGE STEAM GENERATOR CALL (TAC NO. MB7271)

Based on the recent findings at Diablo Canyon (circumferential cracking in the U-bend areas of higher row tubes; i.e., rows >4), the NRC staff would like to have a pre-outage call with the Beaver Valley Power Station (BVPS) licensee to:

1. Make sure the licensee is aware of the findings at Diablo Canyon.
2. Discuss the licensees plans to address this concern for the upcoming BVPS, Unit 1 outage early next month.
3. Discuss the implications of the Diablo Canyon findings on BVPS and, if there are none, to discuss why not.

It would also be helpful to know if BVPS, Unit 1 or BVPS Unit 2 has any operational primary-to-secondary leakage - and if so, how much.

Attachment