FSBEVS Action Instrumentation 3.3.8 3.3 INSTRUMENTATION 3.3.8 Fuel Storage Building Emergency Ventilation System (FSBEVS) Actuation Instrumentation LCO 3.3.8 APPLICABILITY:

FSBEVS manual and automatic actuation instrumentation shall be OPERABLE.

During movement of recently irradiated fuel in the fuel storage building.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Manual or automatic A.1 Place FSBEVS in Immediately FSBEVS actuation operation.

instrumentation inoperable.

OR A.2 Suspend movement of Immediately recently irradiated fuel in the fuel storage building.

Amendment 215 I

3.3.8-1 INDIAN POINT 3

FSBEVS 3.7.13 3.7 PLANT SYSTEMS 3.7.13 Fuel Storage Building Emergency Ventilation System (FSBEVS)

LCO 3.7.13 APPLICABILITY:

FSBEVS shall be OPERABLE.

During movement of recently irradiated fuel assemblies in the fuel storage building.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

FSBEVS inoperable.

A.1 Suspend movement of Immediately recently irradiated fuel assemblies in the fuel storage building.

Amendment 215 I

INDIAN POINT 3 3.7.13-1

Containment Penetrations 3.9.3 3.9 REFUELING OPERATIONS 3.9.3 Containment Penetrations The containment penetrations shall be in the following status:

a.

The equipment hatch closed and held in place by at least four bolts or the equipment hatch opening is closed using an equipment hatch closure plate that may include a personnel access door that is capable of being closed;

b.

One door in each air lock is capable of being closed;

c.

Each penetration providing direct access from the containment atmosphere to the outside atmosphere either:

1.

closed by a manual or automatic isolation valve, a blind flange, or equivalent, or

2.

capable of being closed by OPERABLE Containment Purge Isolation System.

NOTE-Penetration flow path(s) providing direct access from the containment atmosphere to the outside atmosphere may be unisolated under administrative controls.

APPLICABILITY:

During movement of recently irradiated fuel assemblies within containment.

INDIAN POINT 3 LCO 3.9.3 3.9.3-1 Amendment 215

Containment Penetrations 3.9.3 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more containment A.1 Suspend movement of Immediately penetrations not in recently irradiated fuel required status.

assemblies within containment INDIAN POINT 3 3.9.3-2 Amendment 2135

Containment Penetrations 3.9.3 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.9.3.1 Verify each required containment penetration is in the 7 days required status.

SR 3.9.3.2 Verify each required containment purge system valve 92 days actuates to the isolation position on an actual or simulated actuation signal.

Amendment 215 INDIAN POINT 3 3.9.3-3