Text
Peter E. Katz Vice President Calvert Cliffs Nuclear Power Plant Constellation Generation Group, LLC 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 410 495-4455 410 495-3500 Fax Constellation Energy Group March 13, 2003 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:
SUBJECT:
Document Control Desk Calvert Cliffs Nuclear Power Plant Unit Nos. 1 & 2; Docket Nos. 50-317 & 50-318 Response to Request for Additional Information Regarding Interim Inspection Requirements for Reactor Pressure Vessel Head (TAC NOS. MB7752 and MB7753)
REFERENCES:
(a)
Letter from Mr. P. E. Katz (CCNPP) to Document Control Desk (NRC),
dated February 18, 2003, Response to Issuance of Order Establishing Interim Inspection Requirements for Reactor Pressure Vessel Heads at Pressurized Water Reactors (b)
Letter from Mr. S. J. Collins (NRC) to Holders of Licenses for Operating Pressurized Water Reactors, dated February 11, 2003, Issuance of Order Establishing Interim Inspection Requirements for Reactor Pressure Vessel Heads at Pressurized Water Reactors (EA-03-009)
(c)
Letter from Mr. P. S. Tam (NRC) to Mr. P. E. Katz (CCNPP), dated February 28, 2003, Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 Request for Additional Information Regarding Interim Inspection Requirements for Reactor Pressure Vessel Head (TAC Nos. MB7752 and MB7753)
By letter dated February 18, 2003 (Reference a), Calvert Cliffs Nuclear Power Plant, Inc. submitted a request for relaxation from the inspection requirements of Section IV.C(1)(b)(1) of Reference (b). This letter provides Calvert Cliffs Nuclear Power Plant's response to the February 28, 2003, letter (Reference c) request from the Nuclear Regulatory Commission for additional information regarding that relaxation request. The requested information and our responses are contained in Attachment (1) to this letter.
Document Control Desk March 13, 2003 Page 2 Should you have questions regarding this matter, we will be pleased to discuss them with you.
Very trujy yours, STATE OF MARYLAND COUNTY OF CALVERT
- TO WIT:
I, Peter E. Katz, being duly sworn, state that I am Vice President - Calvert Cliffs Nuclear Power Plant, Inc. (CCNPP), and that I am duly authorized to execute and file this response on behalf of CCNPP. To the best of my knowledge and belief, the statements contained in this document are true and correct. To the extent that these statements are not based on my personal knowledge, they are based upon information provided by other CCNPP employees and/or consultants.
Such information has been reviewed in accordance with company practice and I believe it to be reliable.
SubscrIbed and sworn before mne, a Notary Public in and for the State of Maryland and County of jf4
, this /..tKday of 7h
.VA*, 2003.
WITNESS my Hand and Notarial Seal:
My Commission Expires:
Notary Public
\\D/i /ate Date PEK/JKK/bjd Response to NRC Request for Additional Information cc:
J. Petro, Esquire J. E. Silberg, Esquire Director, Project Directorate 1-1, NRC G. S. Vissing, NRC H. J. Miller, NRC Resident Inspector, NRC R. I. McLean, DNR
Attachment:
(1)
ATTACHMENT (1)
RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION Calvert Cliffs Nuclear Power Plant, Inc.
March 13, 2003
ATTACHMENT (1)
RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION NRC Request:
What is the justification that coverage up to 0. 75 inches above the weld will provide an adequate level of quality and safety? In other words, provide justification that increasing the scope of inspection to 2 inches above the J-groove will not provide an increase in quality and safety. Are there residual stress data that indicates that 0. 75 inches is a sufficient level above the weld, or is there any other basis that demonstrates an acceptable level of quality and safety for the restricted inspections?
CCNPP Response:
Calvert Cliffs requested relaxation of the requirement of Section IV.C(1)(b)(i) of Reference 1, to perform Ultrasonic Testing (UT) of each reactor pressure vessel (RPV) head penetration nozzle (i.e., nozzle base material) from 2 inches above the J-groove weld, to the bottom of the nozzle. Calvert Cliffs proposes, as an alternative, a minimum of 0.75 inches above the J-groove weld.
This relaxation request would typically be applied to a limited portion of most of the nozzles, for a minimal azimuthal extent around the nozzle. Coverage for the full 2 inches above the J-groove weld is anticipated for most of the azimuthal extent of most penetrations. Additional coverage can only be achieved by removal of thermal sleeves.
The geometry of the nozzle and thermal sleeve creates a gap that will accept a blade UT probe for a certain distance above the bottom of the nozzle. The hillside J-groove weld configuration does not place the weld a full 2 inches above this point for the full 360 degrees around the nozzle. The limitations are predominantly on the uphill sides of the nozzles.
Increasing the minimum required inspection coverage from 0.75 inches above the J-groove weld to 2 inches above the J-groove weld would not provide additional safety or quality.
The ultrasonic examination provides assurance that the Alloy 600 nozzle base material does not have axial or circumferential cracks. Cracking, if present, would be attributable to primary water stress corrosion cracking (PWSCC), which has been observed in a number of other pressurized water reactor RPV heads in the U.S. as well as several pressurized water reactors in other countries.
Primary water stress corrosion cracking in RPV heads is caused by susceptible materials under high residual stresses usually caused by mechanical working and/or shrinkage stresses associated with welding. A diagram of the Calvert Cliffs RPV head configuration is presented in Figure 1. A Finite Element Analysis was used to calculate the distribution of residual stresses in the Calvert Cliffs RPV head nozzles (Reference 2). Representative results are provided in Figures 2 through 7, with the proposed 0.75-inch minimum coverage superimposed. The residual hoop stress declines along a steep gradient above the weld. Within the first 0.75 inches above the weld, the maximum residual (plus operating) hoop stress decreases to below approximately 40 ksi in all cases. Therefore, the residual plus operating stress existing 0.75 inches above the J-groove weld is less than, or equal to, the minimum stress that would make crack initiation possible. Both crack growth rate and time-to-initiation have been shown to be strongly dependent on applied stress, with damage rate proportional to
'm, where m ranges between 4 and 5.5 (References 3 and 4). This correlation indicates that a 50% reduction in stress will result in a 16-fold reduction in damage rate (or a 16-fold increase in PWSCC initiation time.) Both a threshold stress, or stress-based, time-to initiation model indicate a very low likelihood of the initiation of cracks above 0.75 inches above the top of the uphill side of the nozzle penetration.
Considering the reduced level of stress 0.75 inches above the J-groove weld, it is very unlikely that PWSCC would initiate in the region for which the relaxation is being requested. It is extremely likely that if PWSCC does initiate in the RPV head material, it will initiate in the area that we will be able to inspect. We intend to inspect the region of the penetrations where cracking has the highest driving force for initiation. The additional 1.25 inches of coverage (up to 2 inches above the J-groove weld) would be in a region where crack initiation is not expected. The inspection contractor has evaluated approximately 260 cracks in RPV heads at other nuclear power plants; all of the cracks had a bottom end lower than I
ATTACHMENT (1)
RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION 0.75 inches above the top of the high hillside portion of the J-groove weld (Figure 8). Analytical residual stress analysis and field experience both indicate that all PWSCC cracks, in RPV heads, have a bottom end at or below the elevation of the top of the high hillside portion of the J-groove weld. We expect to achieve examination coverage at least 0.75 inches above this location. Inspection to higher elevations provides no additional safety or quality.
It is possible that cracking could initiate in the highly stressed area adjacent to the J-groove weld, and that the cracks could subsequently propagate upward into the lower stressed region above the J-groove weld.
In this case, the UT, in accordance with this relaxation request, would still identify the lower end of the crack. If the lower end of a crack is detected during the UT examination, our inspection plans include provisions to fully characterize the extent of the indication.
REFERENCES:
- 1.
Letter from Mr. S. J. Collins (NRC) to Holders of Licenses for Operating Pressurized Water Reactors, dated February 11, 2003, Issuance of Order Establishing Interim Inspection Requirements for Reactor Pressure Vessel Heads at Pressurized Water Reactors (EA-03-009)
- 2.
Fleming, M. R. and J. E. Broussard, "Calvert Cliffs Units 1 and 2 CEDM and ICI Stress Analysis,"
Dominion Engineering, Inc. (DEI) Calculation C-3655-00-01, Revision 0, December 21, 2001
- 3.
P. Scott, "Prediction of Alloy 600 Component Failures in RWP System," Research Topical Symposia Part 1 - Life Prediction of Structures Subject to Environmental Degradation, NACE, Houston, pp 135-160 (1997)
- 4.
R. Bandy and D. van Rooyen, "Quantitative Examination of Stress Corrosion Cracking of Alloy 600 in High Temperature Water," Nuclear Engineering and Design, Vol. 86, No. 1 pp. 49-56 (Apr 1982) 2
ATTACHMENT (1)
RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION Schematic of penetratio thermal sleeve s]
dimensional transitions 21.031 in and howing 3
Figure 1: Schematic of a nozzle with thermal sleeve installed. For peripheral nozzles the weld beads are oblique to the axis of the nozzle. The lID of the nozzle changes along the length of the nozzle. For peripheral nozzles the higher side J-groove weld is located closer to the ID step change, limiting the maximum possible length for blade probe insertion.
ATTACHMENT (1)
RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION 4
ATTACHMENT (1)
RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION ANSYS 5.7 DEC 19 2001 16:34 :07 PLOT NO.
3 0.75 inches ELEMENTS PowerGraphics above weld root EFAcET~j MAT NUM NODAL SOLUTION TIME=4004 SY (AVGý RSYS=11 PowerGraphics EFACET=1 AVRES=Mat DMX =.410029 SMN =-27214 SMX =68978
-27214 i
-10000 0
10000 20000 30000 40000 50000 100000 Figure 4:
Stress contour for CEDM nozzle. Plot shows hoop stresses for a 42 ksi yield strength nozzle at a 29 degree angle
,CC CRDM(29.13d,42k,3.85/2.718,3.5E-O3,A)
- Operating 0.75 inches ANYs 5.7 DEC 19 2001 above weld root 19:o01:o00 PLOT NO.
PowerGraphics EFACRT=I MAT NUM NODAL SOLUTION TIME=4004 SY (AVG)
RSYS=II PowerGraphics EFACET=1 AVRES=Mat DMX =.411895 SMN.- 32908 SMX =76770
-32908
--10000 0
10000 20000 S30000 7140000 I
50000 100000 Figure 5:
Stress contour for CEDM nozzle. Plot shows hoop stresses for a 42 ksi yield strength nozzle in the peripheral configuration (42.5 degrees)
CC CEDM(42.5d,42k,3.85/2.718,3.SE-03,A)
-Operating C,017
ATTACHMENT (1)
RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION ANSYS 5.7 DEC 19 2001 14:10:58 PLOT NO.
ELEMENTS MAT NUM NODAL SOLUTION TIME=4004 SZ (AVG)
RSYS=11 PowerGraphics EFACET=1 AVRES-Mat DMX =.405035 SMN -- 39367 SMX =3963C
-39367
-10000 0
10000 20000 30000 40000 m
50000 100000 CC CEDM(42.5d,42k,3.85/2.718,3.5E-03,A)
- Operating NODAL SOLUTION TIME=4004 SZ (AVG)
RSYS=11 Powe rGraphics EFACET=1 AVRES Mat DMX =.411895 SMM =-38712 SMX =51124
-38712
-10000
~0 10000 20000 30000 40000 50000 100000 6
Figure 6:
Stress contour for CEDM nozzle. Plot show axial stresses for a 42 ksi yield strength nozzle at an 11 degree angle Figure 7:
Stress contour for CEDM nozzle. Plot shows axial stresses for a 42 ksi yield strength nozzle at a peripheral location (42.5 degrees) 4
ATTACHMENT (1)
RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION Vertical Distance from Weld Root to Lower End of Flaw 8
7 6
.5 03 2
1 0
0 60 120 180 240 300 Nozzle Circumference (Degrees)
Figure 8: Illustration of the elevation of the lower end of every CEDM crack indication ever identified by inspection contractor.
7 Ccoq-360