POINT BEACH NUCLEAR PLANT AOP-10 ABNORMAL OPERATING PROCEDURE SAFETY RELATED Revision 0 2/18/2002 CONTROL ROOM INACCESSIBILITY Page 6 of 18 ACTION/EXPECTED RESPONSE I I RESPONSE NOT OBTAINED ATTACHMENT A (Page 2 of 2)

Unit 1 AFW PUMP OPERATOR A4 Maintain S/G Levels Between 300 Inches And 330 Inches Using Turbine-Driven AFW Pump IF level can NOT be maintained using turbine-driven AFW pump.

THEN maintain A S/G level using motor-driven AFW pump as follows:

a. At N-01. place P-38A in

- LOCAL.

b. At N-01, depress start pushbutton.
c. Open AF-4023.
d. Throttle 1AF-31 to maintain A S/G level -

BETWEEN 300 INCHES AND 330 INCHES.

1 ILI-460-AA on 1RK-38 1

ILI-460-BA on 1RK-38

e. Inform DOS that B S/G atmospheric steam dump should be isolated.

a IMS-2015 A5 Inform DOS That S/G Levels Are BETWEEN 300 INCHES AND 330 INCHES

- END-AY

)§ý3 L~I[

CAUTION To prevent AFW pump damage, monitor and maintain minimum AFW discharge flow or stop the affected AFW pump as necessary to control SIG levels.

"o P-38A minimum flow - GREATER THAN 50 GPM "o P-29 minimum flow - GREATER THAN 75 GPM 1

POINT BEACH NUCLEAR PLANT AOP-10 ABNORMAL OPERATING PROCEDURE SAFETY RELATED Revision 0 2/18/2002 CONTROL ROOM INACCESSIBILITY Page 8 of 18 ACTION/EXPECTED RESPONSE I I RESPONSE NOT OBTAINED ATTACHMENT B (Page 2 of 2)

Unit 2 AFW PUMP OPERATOR B4 Maintain S/G Levels Between 300 Inches And 330 Inches Using Turbine-Driven AFW Pump IF level can NOT be maintained using turbine-driven AFW pump, THEN maintain B S/G level using motor-driven AFW pump as follows:

a. At N-02, place P-38B in - LOCAL.
b.

At N-02. depress start pushbutton.

c. Open AF-4020.
d. Throttle AF-45 to maintain B S/G level -

BETWEEN 300 INCHES AND 330 INCHES.

e.

Inform DOS that A S/G atmospheric steam dump should be isolated.

  • 2MS-2016 B5 Inform DOS That S/G Levels Are BETWEEN 300 INCHES AND 330 INCHES

-END-L~II CAUTION To prevent AFW pump damage, monitor and maintain minimum AFW discharge flow or stop the affected AFW pump as necessary to control S/G levels.

"o P-38B minimum flow -

GREATER THAN 50 GPM "o P-29 minimum flow -

GREATER THAN 75 GPM K