ML030720353

From kanterella
Jump to navigation Jump to search
FEMA Final Exercise Report, Enrico Fermi 2 Nuclear Power Plant
ML030720353
Person / Time
Site: Fermi 
Issue date: 12/11/2002
From: Buikema E
Federal Emergency Management Agency
To: Dyer J
NRC/RGN-III
References
Download: ML030720353 (49)


Text

Federal Emergency Management Agency Region V 536 South Clark Street, 6th Floor Chicago, IL 60605-1521 Mr. James Dyer, Regional Admini Ltor DEC 1 1 2002 U.S. Nuclear Regulatory Commiss Region III 801 Wanrenville Road Lisle, Illinois 60532-4351

Dear Mr. Dyer:

Enclosed is the Final Report forth4 Radiological Emergency Preparedness Plume Pathway Exercise conducted on September 24,2002, for the Enrico Fermi 2 Nuclear Power Plant.

No Deficiencies were identified duijng this exercise. Two Areas Requiring Corrective Action (ARCA) were identified during thiý exercise. The first ARCA was identified in Monroe County under Criterion 5.b. 1 wherein staff at the Public Inquiry Hotline (Emergency Information/Rumor Control Center) provided inaccurate or improper information to the public, The second ARCA was identified in Wayne County under Criteria 5.a. 1 wherein Emergency Alert System messages included a Livestock Advisory, which was in conflict with the State of Michigan Department of Agriculture's decision not to issue this advisory. There was one prior ARCA for the State of Michigan identified under Criterion 2.b.2, Protective Action Decision Making, which was resolved during this exercise. A detailed description of each issue can be found in Part IV of the final report.

Based on the results of the September 24, 2002, exercise, the offsite radiological emergency response plans and preparedness foir the State of Michigan, and the Counties of Monroe and Wayne, site-specific to the Enrico Fermi 2 Nuclear Power Plant, can be implemented. These plans are adequate to provide reasonable assurance that appropriate measures can be taken offsite to protect the health and safety of the public. Therefore, Title 44 CFR,, Part 350, approval of the offsite radiological emergency response plans and preparedness for the State of Michigan and the Counties of Monroe and Wayne granted on March 9, 1987, remains in effect.

Copies of this report were transmitted to the Nuclear Regulatory Commission National Office, the Federal Emergency Management Agency National Office, and the State of Michigan. If you have any questions, please let me know or have a member of your staff contact Woodie Curtis at (312) 408-5528.

Sincerely, Edward G. Buikema Regional Director Enclosure





Final Exercise Report Enrico Fermi 2 Nuclear Power Plant Licensee:

Exercise Date:

Report Date:

Detroit Edison Company September 24, 2002 December 11, 2002 FEDERAL EMERGENCY MANAGEMENT AGENCY REGION V 536 South Clark Street, 6th Floor Chicago, IL 60605

TABLE OF CONTENTS Page

1.

EX ECU TIV E SU M M A R Y................................................................................................

1 II.

IN TR O D U C TIO N..............................................................................................................

2 III.

EXERCISE OVERVIEW..............................................................................................

4 A.

Plume Emergency Planning Zone Description..................................................

4 B.

Exercise Participants..........................................................................................

5 C.

Exercise Tim eline..............................................................................................

7 IV.

EXERCISE EVALUATION AND RESULTS..............................................................

9 A.

Summary Results of Exercise Evaluation..........................................................

9 B.

Status of Jurisdictions Evaluated.....................................................................

12

1.

STATE OF MICHIGAN.....................................................................

14 1.1 Initial Notification Point.........................................................

14 1.2 Emergency Operations Center................................................

14 1.3 Technical Support Group..........................................................

15 1.4 Dosimetry/KI Distribution.......................................................

15 1.5 Joint Public Information Center..............................................

15 1.6 Michigan State Police Traffic and Access Control Point.........................................

16 1.7 Department of Environmental Quality (DEQ) - Monroe County Evacuee/Vehicle Monitoring and Decontamination............. 16 1.8 DEQ - Wayne County Evacuee/Vehicle Monitoring and Decontamination............. 16 1.9 DEQ - Monroe County Emergency Worker/Vehicle Monitoring and Decontamination 17 1.10 DEQ - Wayne County Emergency Worker/Vehicle Monitoring and Decontamination 17

2.

RISK JURISDICTIONS.......................................................................

17 2.1 M onroe County.......................................................................

17 2.1.1 Initial Notification Point..............................................

17 2.1.2 Emergency Operations Center.....................................

18 i

2.1.3 Traffic and Access Control Point...................................

18 2.1.4 Joint Public Information Center, County PIO............. 18 2.1.5 Public Inquiry Hotline..................................................

19 2.1.6 Protective Actions for School Children - EV2........

20 2.1.7 Dosimetry/KI Distribution............................................

20 2.1.8 Evacuee Monitoring and Decontamination................. 20 2.1.9 Evacuee Vehicle Monitoring and Decontamination......... 21 2.1.10 Public Reception.........................................................

21 2.1.11 Congregate Care.........................................................

21 2.1.12 Emergency Worker/Vehicle Monitoring and Decontamination.............................

22 2.2 W ayne County.........................................................................

22 2.2.1 Initial Notification Point..............................................

22 2.2.2 Emergency Operations Center.....................................

22 2.2.3 Traffic and Access Control Point................................ 23 2.2.4 Joint Public Information Center, County PIO...............

24 2.2.5 Emergency Alert System Radio Station....................... 24 2.2.6 Protective Actions for School Children - EV2........

24 2.2.7 Dosimetry/KI Distribution............................................

25 2.2.8 Emergency Worker/Vehicle Monitoring and Decontamination.............................

25 2.2.9 Evacuee Monitoring and Decontamination................. 25 2.2.10 Evacuee Vehicle Monitoring and Decontamination......... 26 2.2.11 Public Reception.........................................................

26 2.2.12 Congregate Care.........................................................

26 List of Appendices APPENDIX 1 - ACRONYMS AND ABBREVIATIONS.......................................................

27 APPENDIX 2 - EXERCISE EVALUATORS AND TEAM LEADERS................................ 29 APPENDIX 3 - EXERCISE CRITERIA AND EXTENT-OF-PLAY AGREEMENT........

32 APPENDIX 4 - EXERCISE SCENARIO................................................................................

42 List of Tables Table I - Exercise Tim eline.......................................................................................................

8 Table 2 - Summary Results of Exercise Evaluation................................................................

10 ii

1.

EXECUTIVE

SUMMARY

On September 24, 2002, an exercise was conducted in the plume exposure pathway emergency planning zone (EPZ) around the Enrico Fermi 2 Nuclear Power Plant by the Federal Emergency Management Agency (FEMA), Region V. The purpose of this exercise waspc-assess the level of State and local preparedness in responding to a radiological emergency. This exercise was held in accordance with FEMA's policies and guidance concerning the exercise of State and local Radiological Emergency Response Plans (RERPs) and procedures.

The most recent exercise at this site was conducted on October 25, 2000. The qualifying emergency preparedness exercise was conducted on February 2, 1982.

FEMA wishes to acknowledge the efforts of the many individuals who participated in this exercise. In the State of Michigan the risk counties of Monroe and Wayne participated along with the State government.

Protecting the public health and safety is the full-time job of some of the exercise participants and an additional assigned responsibility for others. Still others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities. Cooperation and teamwork on the part of all the participants was evident during this exercise.

This report contains the evaluation of the biennial exercise.

The State and local organizations, except where noted in this report, demonstrated knowledge of their emergency response plans and procedures, and adequately implemented them. No Deficiencies were identified during this exercise. Two Areas Requiring Corrective Action (ARCA) were identified during this exercise. The first ARCA was identified in Monroe County under Criterion 5.b. 1 wherein staff at the Public Inquiry Hotline (Emergency Information/Rumor Control Center) provided inaccurate or improper information to the public. The second ARCA was identified in Wayne County under Criteria 5.a. 1 wherein Emergency Alert System messages included a Livestock Advisory, which was in conflict with the State of Michigan Department of Agriculture's decision not to issue this advisory. There was one prior ARCA for the State of Michigan identified under Criterion 2.b.2, Protective Action Decision Making, which was resolved during this exercise.

I

II.

INTRODUCTION On December 7, 1979, the President directed FEMA to assume the lead responsibility for all off-site nuclear planning and response. FEMA's activities are conducted pursuant to 44 Code of Federal Regulations (CFR) Parts 350, 351, and 352. These regulations are a key element-in the Radiological Emergency Preparedness (REP) Program that was established following the Three Mile Island Nuclear Station accident in March 1979.

FEMA Rule 44 CFR 350 establishes the policies and procedures for FEMA's initial and continued approval of State and local governments' radiological emergency planning and preparedness for commercial nuclear power plants. This approval is contingent, in part, on State and local governments' participation in joint exercises with licensees.

FEMA's responsibilities in radiological emergency planning for fixed nuclear facilities include the following:

Taking the lead in off-site emergency planning and in the review and evaluation of RERPs and procedures developed by State and local governments; Determining whether such plans and procedures can be implemented on the basis of observation and evaluation of exercises of the plans and procedures conducted by State and local governments; Responding to requests by the U.S. Nuclear Regulatory Commission (NRC) pursuant to the Memorandum of Understanding between the NRC and FEMA dated June 17, 1993 (Federal Register, Vol. 58, No. 176, September 14, 1993); and Coordinating the activities of Federal agencies with responsibilities in the radiological emergency planning process:

U.S. Department of Agriculture; U.S. Department of Commerce; U.S. Department of Energy; U.S. Department of Health and Human Services; U.S. Department of the Interior; U.S. Department of Transportation; U.S. Environmental Protection Agency; U.S. Food and Drug Administration; and U.S. Nuclear Regulatory Commission.

Representatives of these agencies serve on the FEMA Region V Regional Assistance Committee (RAC), which is chaired by FEMA.

Formal submission of the RERPs for the Enrico Fermi 2 Nuclear Power Plant to FEMA Region V by the State of Michigan and involved local jurisdictions occurred on 2

March 22, 1982. Formal approval of these RERPs was granted by FEMA on March 9, 1987, under 44 CFR 350.

A REP exercise was conducted on September 24, 2002, and evaluated by FEMA Region V, to assess the capabilities of State and local emergency preparedness organizations in impementing their RERPs and procedures to protect the public health and safety during a radiological emergency involving the Enrico Fermi 2 Nuclear Power Plant. The purpose of this exercise report is to present the exercise results and findings on the performance of the off-site response organizations (ORO) during a simulated radiological emergency.

The findings presented in this report are based on the evaluations of the Federal evaluation team, with final determinations made by the FEMA Region V RAC Chairperson, and approved by the Regional Director.

The criteria utilized in the FEMA evaluation process are contained in:

NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980; FEMA-REP-14, "Radiological Emergency Preparedness Exercise Manual,"

September 1991; and FEMA "Radiological Emergency Preparedness: Exercise Evaluation Methodology" as published in the Federal Register Notice/Vol. 67, No. 80, dated April 25, 2002.

Section III of this report, entitled "Exercise Overview," presents basic information and data relevant to the exercise. This section of the report contains a description of the plume pathway EPZ, a listing of all participating jurisdictions and functional entities, which were evaluated, and a tabular presentation of the time of actual occurrence of key exercise events and activities.

Section IV of this report, entitled "Exercise Evaluation and Results," presents detailed information on the demonstration of applicable exercise criteria at each jurisdiction or functional entity evaluated in a jurisdiction-based, issues-only format. This section also contains: (1) descriptions of all Deficiencies and ARCAs assessed during this exercise, recommended corrective actions, and the State and local governments' schedule of corrective actions, if applicable, for each identified exercise issue; and (2) descriptions of unresolved ARCAs assessed during previous exercises and the status of the OROs' efforts to resolve them.

3 iiiiiiiiiiiiiiiiiiiiiillillillillillillilliillillillillillillilliillillillillilillillillillillillilliillillillillillillilliillillillillillillm---

It.-

III. EXERCISE OVERVIEW Contained in this section are data and basic information relevant to the September 24, 2002, exercise to test the off-site emergency response capabilities in the area surrounding the Enrico Fermi 2 Nuclear Power Plant. This section of the exercise report includes a description of the 10-mile plume pathway EPZ, a listing of all participating jurisdictions and functional entities that were evaluated, and a tabular presentation of the time of the actual occurrence of key exercise events and activities.

A.

Plume Emergency Planning Zone Description The Enrico Fermi 2 Nuclear Power Plant is comprised of approximately 1,120 acres of land owned by DTE Energy. The site is bounded on the north by Swan Creek, on the east by Lake Erie, on the south by Pointe Aux Peaux Road, and on the west by Toll Road. Entrance to the site is from Enrico Fermi Drive (a private road owned by utility) to the west, and from Pointe Aux Peaux Road to another private road owned by utility to the south.

The plant is approximately six miles northeast of Monroe, Michigan; 30 miles southwest of downtown Detroit, Michigan; and 25 miles northeast of downtown Toledo, Ohio. The latitude of the site is 410 57' 48" north and the longitude is 830 15' 31" west. Site elevations range from the level of Lake Erie, on the eastern edge of the site, to approximately 25 feet above the lake level, on the western edge of the site.

The 10-mile EPZ includes parts of Monroe and Wayne Counties in Michigan; parts of Lake Erie; and the southern tip of Essex County, (Bay Point) Canada. Most of the 10-mile EPZ lies within Monroe County. Coordinated efforts occur between the two counties, which are divided into five Protective Action Areas. The following jurisdictions are located within the 10-mile EPZ: Ash Township, Carleton Village, Berlin Township, Estral Beach Village, Exeter Township, South Rockwood Village, Frenchtown Township, Monroe City, Monroe Township, Raisinville Township, Brownstown Township, Gibraltar City, Flat Rock City, and Rockwood City. The population in the 10-mile EPZ, based on the 2000 census, is 88,897.

Land use within the EPZ is diverse. About 55 percent of the land is farmland; the majority of agricultural land is located in Monroe County. The portion of Wayne County nearest to Detroit is a growing residential suburb. Twelve state parks and recreational areas, and several light industries are located within the 10-mile EPZ.

There are three major roads within 10 miles of the plant, Interstates 75 and 275, and U.S. Route 24. Their closest approach to the plant is 4.1 miles, 4.2 miles and 5.8 miles, respectively. Five railroad lines operate within 10 miles of the plant. These include the Canadian National Railroad, the Norfolk Southern Railroad, the Chesapeake and Ohio Railroad, the Detroit Toledo and Ironton Railroad, and the 4

Detroit and Toledo Shore Line Railroad. There are no major airports within 15 miles of the site.

B.

Exercise Participants

- The following agencies, organizations, and units of government participated in the Enrico Fermi 2 Nuclear Power Plant exercise on September 24, 2002:

STATE OF MICHIGAN Department of Agriculture Department of Community Health Department of Environmental Quality Department of Natural Resources Department of State Police Department of Transportation Emergency Management Division Family Independence Agency Michigan Disaster Medical Assistance Team Office of the Governor - Executive Office Office of Services to the Aging Special Operation Division Detroit Edison Liaison Province of Ontario, Canada RISK JURISDICTIONS MONROE COUNTY Agricultural Services County Board of Commissioners Emergency Management Division Emergency Medical Services Family Independence Agency Fire Services Frenchtown Township Health Services Human Services Intermediate School District Michigan State Liaison Monroe City Police Services Public Affairs Public Works Road Commission Sheriff s Office Social Services Detroit Edison Liaison 5

WAYNE COUNTY Emergency Management Division Brownstone Police Department Brownstown Township City of Gibraltar City of Flat Rock City of Rockwood County Board of Commissioners Family Independence Agency Fire Services Health Services Human Services Intermediate School District Michigan State Liaison Michigan State Police Monroe County Liaison Public Affairs Police Services Road Commission Sheriffs Department Social Services Detroit Edison Liaison RISK SCHOOL DISTRICTS Monroe Public Schools Gibraltar School District Hunter Elementary School Carlson High School PRIVATE/VOLUNTEER ORGANIZATIONS American Red Cross Bedford Fire Department Bedford High School Brownstone Fire Station #4 Monroe Community College Radio Amateur Civil Emergency Services Salvation Army Emergency Services Taylor Center High School WJR Radio Station 6

iiiiiiiiiiiiiiiiiiiiiillillillillillillilliillillillillillillilliillillillillilillillillillillillilliillillillillillillilliillillillillill--

isv-C.

Exercise Timeline Table 1, on the following page, presents the times at which key events and activities occurred during the Enrico Fermi 2 Nuclear Power Plant plume pathway exposure exercise on September 24, 2002. Also included are times that notifications were

- made to the participating jurisdictions/fimctional entities.

7

DATE AND SITE: September 24,2002-Enrico Ft Emergency Classification Time Level or Event Utility Declared Unusual Event N/A Alert 0846 Site Area Emergency 0948 General Emergency 1024 Simulated Radiation Release Started 1040 Simulated Radiation Release Terminated N/A Facility Declared Operational Declaration of State of Emergency (Local / State)

Exercise Terminated Facility Operators Food & Feed Facility Advisory 1 " Protective Action Order:

Evacuate Protective Action Areas 1 & 2, and Clear Marine Traffic and Lake Activities within 5 Miles of the plant 1V Siren Activation 1" EAS Message 2 nd Protective Action Order:

Evacuate Protective Action Areas 1, 2, 3, & 4, and Clear Marine Traffic and Lake.Activities within 10 Miles of the plant 2"d Siren Activation 2"d EAS Message KI Administration Decision:

EWs to Ingest KI in Protective Action Areas I & 2 KI Administration Decision:

EWs to Ingest KI in Protective Action Areas 1, 2, 3, & 4 Table 1. Exercise Timeline ermi 2 Nuclear Power Plant Time Notification Was Received or Action Was Taken State of Michigan Monroe County Wayne County

  • Joint Public EOC E

F OC Information Center N/A 0856 1000 1030 1045 N/A 1000 1006 1333 1035 1030 1036 1039 1256 1258 1305 1105 1258 N/A 0859 1005 N/A 0859 1000 1030 1122 N/A 0930 0928 / 1008 1352 1056 1032 1036 1039 1256 1258 1305 1110 1303 N/A N/A 1035 1055 N/A 1030 1037 (State) 1345 1058 1037 N/A N/A I1256 1036 1113 N/A 1000 0929/1010 1340 1055 1035 1036 1039 1256 1258 1305 1106 1305 1305 N/A N/A 1116 N/A

IV. EXERCISE EVALUATION AND RESULTS Contained in this section are the results and findings of the evaluation of all jurisdictions and functional entities that participated in the September 24, 2002, exercise to test the off site emergency response capabilities of State and local governments in the 10-mile EPZ surrgunding the Enrico Fermi 2 Nuclear Power Plant.

Each jurisdiction and functional entity was evaluated based on its demonstration of exercise criteria delineated in Federal Register Notice/Vol. 67, No. 80, dated April 25, 2002. Detailed information on the exercise criteria and the extent-of-play agreement used in this exercise are found in Appendix 3 of this report.

A.

Summary Results of Exercise Evaluation The matrix presented in Table 2, on the following page(s), presents the status of all exercise criteria from Federal Register Notice/Vol. 67, No. 80, dated April 25, 2002, that were scheduled for demonstration during this exercise by all participating jurisdictions and fimctional entities. Exercise criteria are listed by number and the demonstration status of those criteria are indicated by the use of the following letters:

M Met (No Deficiency or ARCA assessed and no unresolved ARCAs from prior exercises)

D Deficiency assessed A

ARCA(s) assessed or unresolved ARCA(s) from prior exercise(s)

N Not Demonstrated (Reason explained in Section IV.B.)

Blank Not scheduled for demonstration 9

Table 2. Summary Results of Exercise Evaluation DATE AND SITE: September 24, 2002 - Enrico Fermi 2 Nuclear Power Plant (Sheet I of 2)

JURISDICTIONS/

FUNCTIONAL ENTITY STATI* OF MICHWIAN Initial Notification Point Emergency Operations Center Technical Support Group Dosimetry/Ki Distribution Joint Public Information Center/PLC Michigan State Police TCP/ACP DEQ - Evacuee & Vehicle M&D (Monroe County)

DEQ - Evacuee & Vehicle M&D (Wayne County)

DEQ - EW/Vehicle M&D (Monroe County)

DEQ - EW/Vehicle M&D (Wayne County)

RISK JURISDICTIONS I.

M M

M M

M MM MM M

M M

M M

M M

1.
h.

I

1.

C.

1.
d.

I M

1.

e.

2.

a.

2.
h.

I

2.
b.

2 I

I I

2.

c.

2.
d.

I 2e e.

3.

a.

3.

b.

3.

C.

3.

C.

3.

d.

3.

d.

3.

e.

3.

e.

3.

f.

4.

a.

4.

a.

4.

a.

4.

b.

4.

C.

5.

a.

a.

5.

a.

5.

b.

6.

a.

6.

b.

6.

C.

6.

d.

IM M

MONROf C*tuNTV Initial Notification Point M

M Emergency Operations Center M MM MM M

M M

M M

M M

M M

Traffic & Access Control Point M

M M M

Joint Public Information Center PlO M

Public Inquiry Hotline A

Protective Actions for School Children - EV 2 tM LEGEND:

M - Met (No Deficiency or ARCA(s) assessed)

D = Deficiency assessed A = ARCA(s) assessed (Not affecting health and safety of public)

U = Unresolved ARCA(s) from prior exercises Blank = Not scheduled for demonstration N = Not demonstrated as scheduled (Reason explained in Section IV.B.

0 MM M

M M

M M

M M

M M

DATE AND SITE: September 24, 2002 Enrico Table 2. Summary Results of Exercise Evaluation Fermi 2 Nuclear Power Plant (Sheet 2 of 2)

JURISDICTIONS/

1.
1.
1.
l.
1.
2. 2.
2. 2. 2. 2.
3.
3.
3.
3.
3.
3.
3.
3.
3. I
4.
4.
4.
4.
5.
5.

5.5.

6.1 6.

6.
6.

FUNCTIONAL ENTITY

a.
b.
c.
d.
e.
a.
b. b. c.
d.
e.
a.
b.
c.
c.
d.
d.

c c

r

a.
a.

b.a.

a

b.
c. 1 d.

1 1

1 12 1

1 1

1 I

2 1

2 3

1 1II2 321 1

I Dosimetry/Kl Distribution M

M M Evacuee M&D M

M Evacuee Vehicle M&D M

Public Reception M

Congregate Care M

EWNehicle M&D M

M M WAYNE C**INTy Initial Notification Point M

M Emergency Operations Center M

M M

M M

M M. M.

M M

A M

Traffic & Access Control Point M

Joint Public Information Center, PlO Emergency Alert System Radio Protective Actions for School Children EV 2 M

Dosimetry/Kl Distribution M

M M EW/Vehicle M&D M

MM Evacuee M&D M

M Evacuee Vehicle M&D M

Public Reception M

Congregate Care I

=

M LEGEND:

M - Met (No Deficiency or ARCA(s) assessed D - Deficiency assessed A = ARCA(s) assessed (Not affecting health and safety of public)

U = Unresolved ARCA(s) from prior exercises Blank = Not scheduled for demonstration N = Not demonstrated as scheduled (Reason explained in Section V.B.)

B.

Status of Jurisdictions Evaluated This subsection provides information on the evaluation of each participating

.juisdiction and functional entity in a jurisdiction-based, issues-only format.

Presented below are definitions of the terms used in this subsection relative to criteria demonstration status.

Met - Listing of the demonstrated exercise criteria under which no Deficiencies or ARCAs were assessed during this exercise and under which no ARCAs assessed during prior exercises remain unresolved.

Deficiency - Listing of the demonstrated exercise criteria under which one or more Deficiencies was assessed during this exercise. Included is a description of each Deficiency and recommended corrective actions.

Area Requiring Corrective Action - Listing of the demonstrated exercise criteria under which one or more ARCAs were assessed during the current exercise or ARCAs assessed during prior exercises remain unresolved. Included is a description of the ARCAs assessed during this exercise and the recommended corrective action to be demonstrated before or during the next biennial exercise.

Not Demonstrated - Listing of the exercise criteria that were not demonstrated as scheduled during this exercise and the reason(s) they were not demonstrated.

Prior ARCAs - Resolved - Descriptions of ARCAs assessed during previous exercises that were resolved in this exercise and the corrective actions demonstrated.

Prior ARCAs - Unresolved - Descriptions of ARCAs assessed during prior exercises that were not resolved in this exercise. Included is the reason the ARCA remains unresolved and recommended corrective actions to be demonstrated before or during the next biennial exercise.

12

The following are definitions of the two types of exercise issues that may be discussed in this report.

A Deficiency is defined in FEMA-REP-14 as "...an observed or identified inadequacy of organizational performance in an exercise that could cause a finding that offsite emergency preparedness is not adequate to provide reasonable assurance that appropriate protective measures can be taken in the event of a radiological emergency to protect the health and safety of the public living in the vicinity of a nuclear power plant."

An ARCA is defined in FEMA-REP-14 as "...an observed or identified inadequacy of organizational performance in an exercise that is not considered, by itself, to adversely impact public health and safety."

FEMA has developed a standardized system for numbering exercise issues (Deficiencies and ARCAs). This system is used to achieve consistency in numbering exercise issues among FEMA Regions and site-specific exercise reports within each Region. It also is used to expedite tracking of exercise issues on a nationwide basis.

The identifying number of Deficiencies and ARCAs includes the following elements, with each element separated by a hyphen (-).

Plant Site Identifier - A two-digit number, corresponding to the Utility Billable Plant Site Code.

Exercise Year - The last two digits of the year the exercise was conducted.

Criterion Number - An alpha and two-digit number corresponding to the criteria numbers in the six Exercise Evaluation Areas described in Federal Register Notice/Vol. 67, No. 80 dated April 25, 2002, which amends FEMA-REP 14, Radiological Emergency Preparedness Exercise Manual.

Issue Classification Identifier - (D = Deficiency, A = ARCA). Only Deficiencies and ARCAs are included in exercise reports. Planning Issues are reported to the State(s) via a letter from the Regional Director.

Therefore, standardized issue numbers are not assigned to Planning Issues.

Exercise Identification Number - A separate two- (or three-) digit indexing number assigned to each issue identified in the exercise.

13

1.

STATE OF MICHIGAN 1.1 Initial Notification Point

a.

MET: Criteria 1.a.1 and l.d.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 1.2 Emergency Operations Center

a.

MET: Criteria L.a.1; L.c.1; 1.d.1; L.e.1; 2.a.1; 2.b.2; 2.c.1; 3.d.1; 5.a.1; and 5.b.l

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED:

Issue No: 44-02-2.b.2-A-01 Condition: The first Livestock Advisory was broadcast to the EPZ population immediately prior to the first Protective Action Order (PAO) to evacuate, while the second Livestock Advisory was issued in conjunction with the second PAO to extend the evacuated area.

Corrective Action Demonstrated: State Emergency Operations Procedures and the Michigan Department of Agriculture Procedures were modified to include a caution not to issue the Livestock Agricultural Advisory if an evacuation has been ordered or is imminent. The Livestock Agricultural Advisory was not made based upon the revised procedures.

f.

PRIOR ISSUES - UNRESOLVED: NONE 14

1.3 Technical Support Group

a.

MET: Criteria 1.e.1; 2.a.1; 2.b.1; and 2.b.2

b. "*"DEFICIENCY: NONE
c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 1.4 Dosimetry/Potassium (KI) Distribution, Michigan State Police Emergency Management Division

a.

MET: Criterion Le.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 1.5 Joint Public Information Center

a.

MET: Criteria 1.b.1 and 5.b.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 15

1.6 Michigan State Police Traffic Control Point/Access Control Point

a.

MET: Criteria 1.d.1; 3.a.1; 3.b.1; and 3.d.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 1.7 DEQ - Evacuee and Vehicle Monitoring and Decontamination, Bedford High School - Monroe County

a.

MET: Criteria 3.a.1 and 6.a.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 1.8 DEQ - Evacuee and Vehicle Monitoring and Decontamination, Taylor Center High School - Wayne County

a.

MET: Criteria 3.a.1 and 6.a.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 16

1.9 DEQ - Emergency Worker (EW)/Vehicle Monitoring and Decontamination, County Fair Grounds - Monroe County

a.

MET: Criteria 3.a.1; 6.a.1; and 6.b.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 1.10 DEQ -EW/Vehicle Monitoring and Decontamination, Brownstone Fire Station #4 - Wayne County

a.

MET: Criteria 3.a.1; 6.a.1; and 6.b.I

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE

2.

RISK JURISDICTIONS 2.1 MONROE COUNTY 2.1.1 Initial Notification Point

a.

MET: Criteria 1.a.1 and 1.d.1

b.

DEFICIENCY: NONE C.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE 17

ýM_

e PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.1.2 Emftgency Operations Center

a.

MET: Criteria 1.a.1; 1.b.1; 1.c.1; 1.d.1; 1.e.1; 2.c.1; 3.a.1; 3.b.1; 3.c.1; 3.c.2; 3.d.1; 3.d.2; 5.a.1; and 5.b.1

b.

DEFICIENCY: NONE

  • c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.1.3 Traffic and Access Control Point

a.

MET: Criteria 1.d.1; 3.a.1; 3.b.1; and 3.d.T

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.1.4 Joint Public Information Center, County Public Information Officer

a.

MET: Criterion 5.b. 1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE 18

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.1.5 Public Inquiry Hotline, Monroe Community College

a.

MET: None

b.

DEFICIENCY: NONE C.

AREAS REQUIRING CORRECTIVE ACTION: Criterion 5.b. 1 Issue No.: 23-02-5.b. 1-A-01 Condition: The Public Inquiry Hotline (Emergency Information/Rumor Control Center) staff provided inaccurate or improper information to the public after confusing a Utility Protective Action Recommendation (PAR) with a State Protective Action Order (PAO). In addition, they advised people that they could enter an area that had been evacuated, under a PAO, to retrieve personnel goods and relatives, but that the police probably would stop them.

Possible Cause: Some of the members of the Public Inquiry Hotline staff do not understand the difference between a Utility PAR and a State PAO. Nor do they understand the implications of a PAO, and the need not to enter an evacuation area in the context of a radiological emergency.

Reference:

NUREG-0654, G.4.c Effect: Members of the public were instructed that they could enter an area that had been designated for evacuation.

Recommendation: The Public Inquiry Hotline staff should receive training that adequately addresses the difference between a Utility PAR and State PAO in the context of a radiological emergency.

Schedule of Corrective Actions: Public Inquiry Hotline staff will be trained on the difference between a protective action order from the Governor and recommendations issued by the utility. Training will also include proper instructions to provide to members of the public seeking to retrieve personal goods and relatives. This criterion will be demonstrated during the next biennial exercise.

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 19

2.1.6 Protective Actions for School Children - EV-2, Monroe Public Schools

a.

MET: Criterion 3.c.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.1.7 Dosimetry/KI Distribution, Monroe County Health Department

a.

MET: Criteria L.e.1; 3.a.1; and 3.b.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.1.8 Evacuee Monitoring and Decontamination, Bedford High School

a.

MET: Criteria 3.a.1 and 6.a.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 20

a.,.-MET: Criterion 6.a.1
b.

DEFICIENCY: NONE C.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES UNRESOLVED: NONE Public Reception, Bedford High School

a.

MET: Criterion 6.a. 1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.1.11 C

a.
b.

C.

d.
e.

f.

ongregate Care, Bedford High School MET: Criterion 6.c.1 DEFICIENCY: NONE AREAS REQUIRING CORRECTIVE ACTION: NONE NOT DEMONSTRATED: NONE PRIOR ISSUES - RESOLVED: NONE PRIOR ISSUES - UNRESOLVED: NONE 21 2.1.10 2.1.9 Evacuee Vehicle Monitoring and Decontamination, Bedford High School

2.1.12 Emergency Worker/Vehicle Monitoring and Decontamination, County Fair Grounds

a.

MET: Criteria 3.a.1; 6.a.1; and 6.b.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2 WAYNE COUNTY 2.2.1 Initial Notification Point

a.

MET: Criteria I.a.1 and 1.d.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2.2 Emergency Operations Center

a.

MET: Criteria L.a.1; 1.b.1; 1.c.1; 1.d.1; 1.e.1; 2.c.1; 3.a.1; 3.b.1; 3.c.1; 3.c.2; 3.d.1; 3.d.2; and 5.b.1

b.

DEFICIENCY: NONE C.

AREAS REQUIRING CORRECTIVE ACTION: Criterion 5.a. 1 Issue No: 23-02-5.a.1-A-02 Condition: The Emergency Alert System (EAS) messages, simulated broadcast at 1039 hours0.012 days <br />0.289 hours <br />0.00172 weeks <br />3.953395e-4 months <br /> and 1305 hours0.0151 days <br />0.363 hours <br />0.00216 weeks <br />4.965525e-4 months <br /> by Wayne County, were in conflict with the 22

Governor's PAOs. The EAS messages instructed the general public to "evacuate immediately", and at the same time instructed farmers to stay behind and "shelter their animals and provide stored feed and water". The State of Michigan Department of Agriculture had decided not to issue a Livestock Agriculture

- Advisory because the Governor had issued a PAO to evacuate persons from the affected areas.

Possible Cause: The Michigan Department of Agriculture procedures were modified to indicate that if an evacuation PAO was imminent or issued by the State, a Livestock Agriculture Advisory would not be issued. When the Department of Agriculture procedures changed, the EAS Evacuation Orders within the Wayne County procedures were not updated to reflect the changes.

Reference:

NUREG-0654, J.9, 10.m Effect: The EAS Evacuation Orders conflicted with the State's PAOs. They instructed the general public to evacuate, but instructed farmers to stay behind and tend to their animals.

Recommendation: The animal advisory, contained within Wayne County's EAS Evacuation Orders, should be removed. Consideration should be given to drafting a separate, stand alone, Livestock Agriculture Advisory that could be disseminated as a news release.

Schedule of Corrective Actions: Wayne County and the State of Michigan agree with the logic of the issue cited. Generic EAS language on placing milk animals within 10 miles on stored feed and water will be deleted. Future agricultural advisories will be issues separate and apart from Governor's PAOs. This criterion will be demonstrated during the next biennial exercise.

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: None f,

PRIOR ISSUES - UNRESOLVED: NONE 2.2.3 Traffic and Access Control Point

a.

MET: Criteria L.d.1; 3.a.1; 3.b.1; and 3.d.1

b.

DEFICIENCY: NONE C.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE 23

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2.4 JoiMti Public Information Center, County Public Information Officer

a.

MET: Criterion 5.b.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2.5 Emergency Alert System Radio Station, WJR

a.

MET: Criterion 5.a.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2.6 Protective Actions for School Children - EV-2, Gibraltar Schools

a.

MET: Criterion 3.c.2

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE 24

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2.7 Dosimetry/KI Distribution, Brownstone Fire Station #4

a.

MET: Criteria 1.e. 1; 3.a.1; and 3.b.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2.8 Emergency Worker/Vehicle Monitoring and Decontamination, Brownstone Fire Station #4

a.

MET: Criteria 3.a.1; 6.a.1; and 6.b.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2.9 Evacuee Monitoring and Decontamination, Taylor Center High School

a.

MET: Criteria 3.a. 1; and 6.a. I

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE 25

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2.10 Evacuee Vehicle Monitoring and Decontamination, Taylor-Center High School

a.

MET: Criterion 6.a.1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2.11 Public Reception, Taylor Center High School

a.

MET: Criterion 6.a. 1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 2.2.12 Congregate Care, Taylor Center Middle School

a.

MET: Criterion 6.c. 1

b.

DEFICIENCY: NONE

c.

AREAS REQUIRING CORRECTIVE ACTION: NONE

d.

NOT DEMONSTRATED: NONE

e.

PRIOR ISSUES - RESOLVED: NONE

f.

PRIOR ISSUES - UNRESOLVED: NONE 26

Emergency Emergency Emergency Emergency Emergency Emergency Alert System Management Division Operations Center Operations Facility Planning Zone Worker Federal Emergency Management Agency Family Independence Agency Field Team Center Health Physics or Health Physicist High School ICF Consulting Joint Public Information Center Potassium Iodide Monitoring and Decontamination milliroentgen milliroentgen per Hour Medical Services Drill Michigan State Police Not Applicable U.S. Nuclear Regulatory Commission 27 EAS EMD EOC EOF EPZ EW FEMA FIA FTC HP HS ICF JPIC KI M&D mR mR/hr MS-1 MSP N/A NRC APPENDIX 1 ACRONYMS AND ABBREVIATIONS The following is a list of the acronyms and abbreviations that were used in this report and the REP Program.

ACP Access Control Point ALARA As Low As Reasonable Achievable ARCA Area Requiring Corrective Action CFR Code of Federal Regulations cpm counts per minute DEQ Department of Environmental Quality

NUREG-0654 NUREG-0654/FEMA-REP-1, Rev. 1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, November 1980.

ORO Off-site Response Organization OSC Operational Support Center PAO Protective Action Order PAR Protective Action Recommendation R

Roentgen R/hr Roentgen per hour RAC Regional Assistance Committee RACES Radio Amateur Civil Emergency Services RASCAL Radiological Assessment System for Consequence Analysis RCP Reactor Coolant Pump RCS Reactor Coolant System REA Radiation Emergency Area rem Roentgen Equivalent Man REP Radiological Emergency Preparedness RERP Radiological Emergency Response Plan SEOC State Emergency Operations Center SGTS Standby Gas Treatment System T/L Team Leader TCP/ACP Traffic and Access Control Point TSC Technical Support Center 28

FEMA ICF Federal Emergency Management Agency ICF Consulting NAME ORGANI7ATION RAC Chairperson Exercise Director Woodie Curtis Gary Naskrent Initial Notification Point Emergency Operations Center Technical Support Dosimetry/KI Distribution Joint Public Information Center Michigan State Police, TCP/ACP DEQ - Evacuee & Vehicle Monitoring and Decontamination, Bedford HS - Monroe County DEQ - Evacuee & Vehicle Monitoring and Decontamination, Taylor Center HS - Wayne County DEQ - Emergency Worker &

Vehicles Monitoring and Decontamination, County Fair Grounds Monroe County Terry Connors-Murphy T. Connors-Murphy (TL)

Gary Naskrent Richard Grundstrom Richard Grundstrom George MacDonald Alejandro Fernandez Eddie Fuente Edward Wojnas William Neidermeyer 29 EVATfTTATTON NrTW STATE OF MICHIGAN FEMA FEMA FEMA FEMA FEMA ICF ICF ICF ICF ICF ICF ICF APPENDIX 2 EXERCISE EVALUATORS AND TEAM LEADERS The following is a list of the personnel who evaluated the Enrico Fermi 2 Nuclear Power Plant exercise on September 24, 2002. Evaluator Team Leaders are indicated by the letters "(TL)" after their names. The organization which each evaluator represents is indicated by the following abbreviations:

Traffic & Access Control Point Joint Public Information Center, County Public Information Officer Public Inquiry Hotline Protective Actions for School Children - EV 2, Monroe Public Schools Dosimetry/KI Distribution Evacuee Monitoring and Decontamination, Bedford HS Evacuee Vehicle Monitoring and Decontamination, Bedford HS Public Reception, Bedford HS Congregate Care, Bedford HS Emergency Worker & Vehicle Monitoring and Decontamination, County Fair Grounds Joseph Lischinsky DEQ - Emergency Worker &

Vehicles Monitoring and Decontamination, Brownstone Fire Station #4 Wayfi& County MONROE COUNTY Initial Notification Point Emergency Operations Center John Turley Carol Herzenberg Eddie Fuente Edward Wojnas Sandra Bailey Sandra Bailey William Neidermeyer Joseph Lischinsky 30 ICF ICF FEMA ICF ICF ICF ICF ICF ICF ICF ICF ICF ICF FEMA FEMA ICF ICF David Goldbloom Helzner Sandra Bailey (TL)

David Goldbloom Helzner Harold Spedding Harold Spedding George Mac Donald Alejandro Fernandez John Turley

Initial Notification Point Emergefncy Operations Center Traffic & Access Control Point Joint Public Information Center, County Public Information Officer Emergency Alert System Radio Station - WJR Protective Actions for School Children - EV2, Gibraltar Schools Dosimetry Distribution Emergency Worker & Vehicle Monitoring and Decontamination, Brownstone Fire Station #4 Evacuee Monitoring and Decontamination, Taylor Center HS Evacuee Vehicle Monitoring and Decontamination, Taylor Center HS Public Reception, Taylor Center HS Congregate Care, Bedford HS Clint Crackel Clint Crackel (TL)

Carolyn Sturghill Nancy Johnson Nancy Johnson George Mac Donald John Turley Carol Herzenberg William Neidermeyer William Neidermeyer Joseph Lischinsky Carol Herzenberg Eddie Fuente Edward Wojnas Carol Herzenberg Alejandro Fernandez 31 FEMA FEMA FEMA ICF ICF ICF ICF ICF ICF ICF ICF ICF ICF ICF ICF ICF WAYNE COUNTY

APPENDIX 3 EXERCISE CRITERIA AND EXTENT-OF-PLAY AGREEMENT This appendix lists the exercise criteria that were scheduled for demonstration in the Enrico Fermi 2 Nuclear Power Plant exercise on September 24, 2002, and the off-site extent-of-play agreement approved by FEMA Region V on August 15, 2002.

The exercise criteria, contained in FEMA "Radiological Emergency Preparedness Exercise Evaluation Methodology" as published in the Federal Register Notice/Vol. 67, No 80, dated April 25, 2002, represent a functional translation of the planning standards and evaluation criteria of NUREG-0654/FEMA-REP-1, Rev. 1, Criteria for the Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, November 1980.

Because the exercise criteria are intended for use at all nuclear power plant sites, and because of variations among off-site plans and procedures, an extent-of-play agreement is prepared by the State and approved by FEMA to provide evaluators with guidance on expected actual demonstration of the criteria.

A.

Exercise Criteria and Extent-of-Play Listed below are the specific REP criteria scheduled for demonstration during this exercise.

32

ENRICO FERMI 2 NUCLEAR POWER PLANT EXERCISE September 24, 2002 Extent Of Play Agreements for Monroe County, Wayne County, and the State of Michigan Evaluation Area 1 - Emergency Operations Managemen; Criterion 1.a.1: OROs use effective procedures to alert, notify and mobilize emergency personnel and activate facilities in a timely manner.

The State Emergency Operations Center (SEOC) will be fully activated. State personnel will be mobilized in accordance with procedures with the exception of personnel reporting to local government EOCs and the JPIC, who will be pre-positioned. Pre positioned personnel will begin participation following the Alert classification as directed by the State Controller in each facility. The Field Team Center and associated personnel will not be demonstrated for this exercise. A cell will be established to initiate exercise data inputs for SEOC players. Personnel involved in out-of-sequence demonstrations will be prestaged. A roster will be provided to demonstrate 24-hour staffing.

The Monroe and Wayne County EOCs will be fully activated. Personnel will be mobilized in accordance with procedures with the exception of those from Wayne County reporting to the JPIC, who will be pre-positioned. Pre-positioned personnel will begin participation no earlier than the Alert classification. Personnel involved in out-of sequence demonstrations will be pre-positioned. Rosters will be provided to demonstrate 24-hour staffing.

Criterion 1.b.1: Facilities are sufficient to support the emergency response.

This criterion will be demonstrated by Monroe County and Wayne County. The SEOC was demonstrated during the Palisades exercise on June 4, 2002. The State, Monroe County, and Wayne County EOCs are all set-up permanently. The JPIC will be set-up in advance of the exercise.

Criterion 1.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.

This criterion will be demonstrated at the SEOC, Monroe County EOC, and the Wayne County EOC.

33

Criterion 1.d.i: At least two communication systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations.

Communications capabilities are managed in support of emergency operations.

Thiscriterion will be demonstrated at the SEOC, Monroe County EOC, the Wayne County EOC, and the JPIC.

Criterion i.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI) and other supplies are sufficient to support emergency operations.

Equipment, maps, displays, and other supplies will be demonstrated to support emergency operations at the SEOC, JPIC, Monroe County EOC, and the Wayne County EOC. The FTC will not be demonstrated. Potassium iodide and dosimetry are stored at the Health Department in Monroe County; at the Emergency Management Office and Brownstown Fire Station #4 in Wayne County; and at the MSP/EMD office in Lansing.

The Michigan Department of Environmental Quality also maintains supplies of potassium iodide and dosimetry for use by its personnel.

Evahlution Area 2 - Protective Action Dpecision Makinu Criterion 2.a.1: OROs use a decision-making process, considering relevant factors and appropriate coordination, to ensure that an exposure control system, including the use of KI, is in place for emergency workers including provisions to authorize radiation exposure in excess of administrative limits or protective action guides.

The ability to make the decision to recommend the use of KI to emergency workers will be demonstrated by the SEOC. Authorization to exceed state exposure limits will be demonstrated as driven by the scenario.

This criterion may be re-demonstrated as approved on a case-by-case basis by the Chair of the Regional Assistance Committee.

Criterion 2.b.1: Appropriate protective action recommendations are based on available information on plant conditions, field monitoring data and licensee and ORO dose projections, as well as knowledge of on-site and off-site environmental conditions.

The Technical Support Group in the SEOC will evaluate licensee and FTC Cell provided information and complete an independent analysis of scenario data. Dose assessment evaluation will be conducted via interview with the individual performing the FTC Cell role at the MSP/EMD office in Lansing.

This criterion may be re-demonstrated as approved on a case-by-case basis by the Chair of the Regional Assistance Committee.

This criterion does not apply to Monroe and Wayne Counties.

34

Criterion 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PADs) for the general public (including the recommendation for the use of KI, if ORO policy).

This,,cFiterion will be demonstrated by the Executive Group in the SEOC in conjunction with applicable support staff.

This criterion may be re-demonstrated as approved on a case-by-case basis by the Chair of the Regional Assistance Committee.

This criterion does not apply to Monroe and Wayne Counties.

Criterion 2.c.i: Protective action decisions are made, as appropriate, for special population groups.

This criterion will be demonstrated by the Executive Group in the SEOC in conjunction with applicable support staff through the decision to recommend the use of KI to institutionalized persons, if applicable.

Lists of transportation dependent and special needs populations are kept by each county. No personnel will be moved. Equipment lists and rosters will be available in the Wayne and Monroe County EOCs. No phone calls to transportation dependent persons will be made.

Criterion 2.d.1: Radiological consequences for the ingestion pathway are assessed and appropriate protective action decisions are made based on the ORO's planning criteria.

This criterion will not be demonstrated during this exercise.

Criterion 2.e.1: Timely re-location, re-entry and return decisions are made and coordinated as appropriate, based on assessments of the radiological conditions and criteria in the OROs plan and/or procedures.

This criterion will not be demonstrated during this exercise.

35

Evaluation Area 3 - Protective Action Implementation Criterion 3.a.1: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plan and procedures.

Emergency*workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart.

Issuance of dosimetry will be discussed during scheduled interviews, which may occur during the exercise. Refer to the Table of Exercise Demonstrations for specific times and locations.

This criterion will be demonstrated by the State of Michigan, Monroe County, and Wayne County during out-of-sequence reception and decontamination center demonstrations.

This criterion will be demonstrated during the traffic and access control demonstrations for Wayne County, Monroe County, and the State of Michigan. The briefing on dosimetry and KI use for the State of Michigan demonstration will be provided by the State Controller.

This criterion may be re-demonstrated immediately for credit, at the discretion of the evaluator.

Criterion 3.b.1: KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals (not the general public) is maintained.

This criterion will be demonstrated during the traffic and access control demonstrations for Monroe County, Wayne County, and the State of Michigan.

Dosimetry and KI for the State demonstration will be pre-staged since the Field Team Center is not being demonstrated for this exercise.

Simulated KI will be distributed to emergency workers in Wayne and Monroe Counties along with their dosimetry if driven by the scenario. The State will demonstrate this criterion through decision-making and orders to the counties to implement appropriate Protective Action Orders.

Criterion 3.c.1: Protective action decisions are implemented for special population groups within areas subject to protective actions.

This criterion will be demonstrated in the Monroe and Wayne County EOCs via EOC staff discussions, which may include evacuation of hospitals, nursing homes, correctional facilities, mobility impaired individuals, and transportation dependent.

These discussions will be documented in situation logs. Actual contacts to special population groups will not be made. Each county will contact a minimum of four providers of transportation services, which may include a public transit authorities, school systems for buses, ambulance services, or a fire/rescue services. There will be no discussion of scenario information during these calls.

36

Criterion 3.c.2: OROs/School officials decide upon and implement protective actions for schools.

ThisGriterion will be demonstrated in the Monroe and Wayne County EOCs as driven by the scenario.

EV-2 interviews will be conducted in Monroe and Wayne Counties. Refer to the Table of Exercise Demonstrations for specific times and locations.

Criterion 3.d.1: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel.

Decisions related to traffic and access control will be demonstrated in the Monroe and Wayne County EOCs. Monroe County, Wayne County, and the State of Michigan will demonstrate one traffic and access control point. Monroe and Wayne County demonstration locations will be determined during the exercise at a time agreed upon by the FEMA evaluator, the State Controller, and the county emergency management coordinator. The State of Michigan demonstration will be initiated by a briefing from a State Controller and may be conducted out-of-sequence from the exercise. Staffing of the all other access and traffic control points will be simulated.

This criterion may be re-demonstrated immediately for credit, at the discretion of the evaluator.

Criterion 3.d.2: Impediments to evacuation are identified and resolved.

This criterion will be demonstrated through discussions at the Monroe and Wayne County EOCs. Messages will be injected by the State Controller to drive this demonstration. Personnel will deal with the impediment by discussing the need for equipment, discussing its estimated time of arrival, etc. The State of Michigan will not demonstrate this criterion. If the impediment posed involves road closures that would have been known to exercise participants during the course of normal operations, this information will be provided to the players as part of the initial conditions for the exercise.

This criterion may be re-demonstrated immediately for credit, at the discretion of the evaluator.

Criterion 3.e.1: The ORO demonstrates the availability and appropriate use of adequate information regarding water, food supplies, milk and agricultural production within the ingestion exposure pathway emergency-planning zone for implementation of protective actions.

This criterion will not be demonstrated during this exercise.

37

ru-v Criterion 3.e.2: Appropriate measures, strategies and pre-printed instructional material are developed for implementing protective action decisions for contaminated water, food products, milk and agricultural production.

This, eriterion will not be demonstrated during this exercise.

Criterion 3.f.1: Decisions regarding controlled re-entry of emergency workers and relocation and return of the public are coordinated with appropriate organizations and implemented.

This criterion will not be demonstrated during this exercise.

Evaluation Area 4 - Field Measurement and Analysis Criterion 4.a.1: The field teams are equipped to perform field measurements of direct radiation exposure (cloud and ground shine) and to sample airborne radioiodine and particulates.

This criterion will not be demonstrated during this exercise.

Criterion 4.a.2: Field teams are managed to obtain sufficient information to help characterize the release and to control radiation exposure.

This criterion will not be demonstrated during this exercise.

Criterion 4.a.3: Ambient radiation measurements are made and recorded at appropriate locations, and radioiodine and particulate samples are collected. Teams will move to an appropriate low background location to determine whether any significant (as specified in the plan and/or procedures) amount of radioactivity has been collected on the sampling media.

This criterion will not be demonstrated during this exercise.

Criterion 4.b.1: The field teams demonstrate the capability to make appropriate measurements and to collect appropriate samples (e.g., food crops, milk, water, vegetation, and soil) to support adequate assessments and protective action decision-making.

This criterion will not be demonstrated during this exercise.

Criterion 4.c.1: The laboratory is capable of performing required radiological analyses to support protective action decisions.

This criterion will not be demonstrated during this exercise.

38

Evaluation Area 5-Emeraency Notification and Public Informatio, Criterion 5.a.1: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to nt-ifythe public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current FEMA REP guidance.

The Wayne County Sheriffs Department and Monroe County Sheriff's Department are the primary activation points for the public warning siren systems. The Emergency Alert System is activated by the Wayne County Sheriff Department for both counties. To demonstrate this criterion, the State will provide information to Monroe and Wayne Counties for release in the Emergency Alert System messages.

This criterion may be re-demonstrated as approved on a case-by-case basis by the Chair of the Regional Assistance Committee.

Criterion 5.a.2: [RESERVED]

Criterion 5.a.3: Activities associated with FEMA approved exception areas (where applicable) are completed within 45 minutes following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. Backup alert and notification of the public is completed within 45 minutes following the detection by the ORO of a failure of the primary alert and notification system.

This criterion does not apply to the State of Michigan, Monroe County, or Wayne County.

Criterion 5.b.1: OROs provide accurate emergency information and instructions to the public and the news media in a timely manner.

This will be demonstrated at the JPIC via dissemination of Emergency Alert System announcements in coordination with the SEOC, Monroe County EOC, and Wayne County EOC. All media briefings will be conducted at the JPIC.

A public inquiry hotline will be operated by Monroe County during the exercise at the JPIC.

This criterion may be re-demonstrated as approved on a case-by-case basis by the Chair of the Regional Assistance Committee.

39

I.

Evaluation Area 6 - Support Operation/Facilitie.*

Criterion 6.a.1: The reception center/emergency worker facility has appropriate space, adequate resources, and trained personnel to provide monitoring, decontamination, and registration.of eVacuees and/or emergency workers.

Wayne and Monroe Counties will each fully demonstrate separate emergency worker and public reception/decontamination centers during out-of-sequence demonstrations.

Personnel will not go through alert, mobilization, activation, or shift changes. State DEQ HP personnel will provide assistance as requested during Monroe and Wayne County demonstrations. Public reception centers will demonstrate the ability to screen 1/3 of the monitoring teams required to monitor 20% of the population allocated to that facility within a 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> time period. The State of Michigan Field Team Center is not being demonstrated.

This criterion may be re-demonstrated immediately for credit, at the discretion of the evaluator.

Criterion 6.b.1: The facility/ORO has adequate procedures and resources for the accomplishment of monitoring and decontamination of emergency worker equipment including vehicles.

Wayne and Monroe Counties will each fully demonstrate an emergency worker decontamination center out-of-sequence with the exercise. Emergency vehicles will be monitored and decontaminated as appropriate. State DEQ HP personnel will provide assistance as requested during Monroe and Wayne County demonstrations. The State of Michigan Field Team Center is not being demonstrated.

This criterion may be re-demonstrated immediately for credit, at the discretion of the evaluator.

Criterion 6.c.i: Managers of congregate care facilities demonstrate that the centers have resources to provide services and accommodations consistent with American Red Cross planning guidelines. Managers demonstrate the procedures to assure that evacuees have been monitored for contamination and have been decontaminated as appropriate prior to entering congregate care facilities.

Wayne and Monroe Counties will each fully demonstrate a congregate care center out of-sequence with the exercise. Personnel manning the centers will not go through alert, mobilization, activation, or shift changes.

This criterion may be re-demonstrated immediately for credit, at the discretion of the evaluator.

40

Criterion 6.d.1: The facility/ORO has the appropriate space, adequate resources, and trained personnel to provide transport, monitoring, decontamination, and medical services to contaminated injured individuals.

Thiscriterion was demonstrated during the Medical Services (MS-i) Drill on March 6, 2002.

This criterion may be re-demonstrated immediately for credit, at the discretion of the "evaluator.

41

APPENDIX 4 EXERCISE SCENARIO This appendix contains a summary of the simulated sequences of events that were used as the basis for invoking emergency response actions by OROs in the Enrico Fermi 2 Nuclear Power Plant exercise on September 24, 2002.

The plume exercise scenario was submitted by the State of Michigan and Detroit Edison Company, and approved by FEMA Region V on August 15, 2002.

During the exercise, controllers from the State of Michigan either gave or telephoned "inject messages", containing scenario events and/or relevant data, to those persons or locations who would normally receive notification of such events. These inject messages were the method used for invoking response actions by OROs.

SCENARIO STIMMARV FERMEX 2002 - EXERCISE DESCRIPTION Initial Conditions The Reactor is operating at 100% power. LLRT on T4803-F601, D/W supply air purge inlet is underway. RHR pump 'C' is out of service for maintenance to E1150-F047A. The Operational Support Center (OSC)/Ops break room is out of service due to remodeling and "cannot be used.

Active Malfunctions Failure of test connection T4802-F018 Fire in Division I Switchgear Room Loss of 64 B (due to fire)

RWCU Effluent High Conductivity Alarm RWCU Effluent High Dissolved Oxygen Alarm Jet Pump #10 failure Three stuck control rods Reactor Recirc 'B' motor impeller failure due to debris RR Loop B failure Standby Gas Treatment System (SGTS) Division I fan failure Release Paths After the primary containment break, there is a release through the test connection to T4803 F601 D/W Supply Air Purge Inlet valve upstream of T4802-F018 valve. The release to the 42

environment will be through the SGTS.

Emergency Response Organization Activation The fire-diat occurs at 0835 in the Division 1 Switchgear room will last greater than 15 minutes. This requires an Alert declaration, resulting in activation of the Alternate Operations Support Center and the Technical Support Center (TSC). A Site Area Emergency should be declared at approximately 0945 when the Emergency Director determines that the Reactor Coolant System and Primary Containment barriers have failed. This declaration will activate the Emergency Operations Facility and the Joint Public Information Center.

Emergency Response Facility Activities

1. Control Room After initial accident response and emergency classification, Control Room makes offsite notifications, activates the emergency response organization, and monitors and controls reactor, primary containment, and secondary containment parameters in accordance with the Emergency Operating Procedures.
2. Operational Support Center The OSC assists the Control Room in monitoring in-plant and onsite radiological conditions and operating, investigating or repairing any plant equipment at the direction of the Emergency Director.
3. Technical Support Center Once declared functional, The TSC assumes responsibility from the Control Room for overall emergency management, offsite notifications, emergency classification, offsite dose assessment, protective action recommendations, and implementing the severe accident management guidelines. Engineering staff provides Emergency Director with technical input to attempt accident mitigation.
4. Emergency Operations Facility Once declared functional, Emergency Operations Facility (EOF) assumes responsibility from Technical Support Center for offsite notifications and protective action recommendations. EOF also performs offsite dose assessment and coordinates activities of offsite Radiological Emergency 43

SEQUENCE OF EVENTS TIME KEY EVENTS 0730 Commence turnover. Initial Conditions: Reactor operating at 100% power. LLRT on T4803-F601, D/W supply air purge inlet is underway. RHR pump 'C' is out of service for maintenance. The OSC/Ops break room is out of service due to remodeling and cannot be used.

0800 Announcement for the start of the exercise.

0802 Upon completion of leak test personnel attempt to re-install the cap, in doing so the test connection is sheared off creating a pathway out of containment 0817*

Expected Action: Shift Manager declares an Unusual Event due to (FU1) loss of Primary Containment.

0835 Fire in Division 1 Switchgear Room, which results in damage to 64B.

0850*

Expected Action: Shift Manager declares an Alert due to fire or explosion affecting the operability of plant safety systems required to establish or maintain safe shutdown.

On-Site Protective Action: Assembly and Accountability ordered.

0900 RWCU Effluent High Conductivity Alarm (Note: local indications as read) 0902 RWCU Effluent High Dissolved Oxygen Alarm (Note: local indications as read) 0920*

Alternate OSC/TSC fiunctional, Assembly and Accountability.

0930 Failure of Jet Pump #10, debris jams the 'B' Recirc Motor Impeller. Reactor Scram with 3 rods stuck. Small break LOCA from the 'B' loop inside containment SGTS Division 1 fan fails.

0945*

Expected Actions: Emergency Director declares a Site Area Emergency due to (FS1) Loss of RCS and Primary Containment.

Loss of 64C bus breakers RHR pump "C" & CS pump "C".

On-Site Protective Action: Evacuate all non-ERO from the site to home or Monroe Power Plant.

The EOF and Joint Public Information Center (JPIC) are activated.

44

1020*

Reactor water level drops to < 0" and Containment High Range Radiation Monitor (CHRRMs) reading is greater than 10,000 R/hr.

1035*

Expected Actions: Emergency Director declares a General Emergency due to loss 6f"3 fission product barriers. (FG1).

Expected PAR: Evacuate Areas I and 2, shelter 3, 4, and 5 based on plant status.

If dose assessment is running, there is no impact on PARs.

1045 The EOF is functional 1115 The JPIC is functional 1145*

Dose Assessment calculations based on effluent radiation monitors indicates exceeding PAGs at five (5) miles forcing a change in PAR.

1200*

Expected PAR: Evacuate Areas 1, 2, 3, and 4, Shelter Area 5.

1215 The ERO takes actions to:

to end

1. Isolate the primary containment leak through the test connection. Personnel will evaluate emergency dose limits for piping repairs. Consideration may be given to drive attempting to close T4803-F601, which will be successful once all other avenues have been evaluated and all other criteria's have been demonstrated.
2. Restore reactor water level and stabilize the plant.
3. Walk down affected areas, and take actions to ensure no further damage occurs.

The exercise will be terminated when the following actions have been completed and all other criteria are demonstrated:

1330*

Provide exercise termination announcement.

Note:

  • Indicated times are based on Emergency Response Organization actions and are approximate.

45